Loading...
2008, 04-14 Permit App: 08001378 Egress Windows Pfoject Number: 08001378 Inv: 1 Application Date: 4/14/2008 Page 1 of 2 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Project Information' w;. � �� � � : _ -- mak, V., r atlaW Permit Use: (2)EGRESS WINDOWS Contact: NELSON HANDYMAN CONSTRUCTION Address: 4826 N ALAMEDA BLVD C-S-Z: SPOKANE WA 99205 Setbacks:Front Left: Right: Rear: Phone: (509)768-4438 Group Name: Site Information: Project Name: Plat Key: 001221 Name: HILLCREST PARK 01ST ADD District: Sout Parcel Number: 45281.0319 Block: 3 Lot: 19 SiteAddress: 1908 S WHIPPLE RD Owner:Name: ESTES,VICKIE Address: 1908 S WHIPPLE RD Location::CSV SPOKANE,WA 99206-5725 Zoning: UR-3.5 Urban Residential 3.5 Water District: Hold: ❑ Area: .00 Acres Width: 0 Depth: 0 Right Of Way(ft): 0 Nbr of Bldgs: 0 Nbr of Dwellings: 0 Review Information• Review Building Plan Review Released : Originally Released: 4/14/2008 By: tmelbourn Operator: JD Printed By: jmm Print Date: 4/14/2008 Ptoject Number: 08001378 Inv: 1 Application Date: 4/14/2008 Page 2 of 2 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Building Permit Contractor: NELSON HANDYMAN Firm: NELSON HANDYMAN CONSTRU Address: 4826 N ALAMEDA BLVD Phone: (509)768-4438 SPOKANE WA 99205 Building Characteristics Building Height 0 This Application: Total Project: Description Grp Type Notes SQ Ft Valuation Sci Ft Valuation 1&2 FAMILY R-3 VB 2 EGRESS 0 $3,500.00 0 $3,500.00 WINDOWS Totals: 0 $3,500.00 0 $3,500.00 Item Description Units Unit Desc Fee Amount RESIDENTIAL PERMIT FEE 1 SELECT $97.25 WSBC SURCHARGE 1 SELECT $4.50 SF PLNS RVW<7999 SQ FT 1 SELECT $38.90 Permit Total Fees: $140.65 Notes: Payment Summary: Permit Type Fee Amount Invoice Amount Amount Paid Amount Owing Building Permit $140.65 $140.65 $0.00 $140.65 $140.65 $140.65 $0.00 $140.65 Disclaimer: Submittal of this application certifies the owner(or person(s)authorized by the owner)has both examined and finds the information contained within to be true and correct,and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for,or an approval of,any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: JD Printed By: jmm Print Date: 4/14/2008 Permit Center *Wan11703E Sprague Ave, Suite B-3 PERMIT NUMBER: /31 Spokane Valley,WA 99206 40, JVa11e (509)688-0036 FAX: (509)688-0037 PERMIT FEE: www.spokanevalley.org Community Development Residential Construction New Construction Accessory Bldg Permit Application jAddition/Remodel Deck Other: SITE ADDRESS: I C(C) SQ (_A 1A, p 12 ?A - ASSESSORSc( PARCEL NO: 1 SDs I.o'- \c,‘ LEGAL DESCRIPTION: Building Owner: Contractor: Name: (....\( .C, -)- 5 Name: ,e, AL2J 50� ),3 6, . Address: ���� C ��' Address °I0� ‹c 1-\, 1,� cA ; 11)� 1C Lik2o til qc-, �&0 \vS City: s`Q�JX0\lsZ �Jc\\\ State:�,U Zip: City��IK,���� State l GtS r- Zip ���� Phone: y Fax: Phone: Fax: Contractor Lic No:c,®a X602(04441ii,Date: 2 ,O c) C g a l c Contac Person City Business Lie.No: Aid J son c Name: Contac -�J ))-(,) DY1 �J 1 Phone:-'�.J� 6 7 - 16(S"q t J% 0(c__ Describe the scope of work in detail: Cost of Project: $ _ oO �')1 STG\\ Tk -e(-, W'II' Proposed Use: e a.f, I,r' B a <,),,,;-,--)\-- **************The following MUST be complete: (write N/A if not applicable)********************** HEIGHT TO PEAK: DIMENSIONS: #OF STORIES: TOTAL HABITABLE SPACE: MAIN FLOOR TO SQ. 2Nu FLOOR SQ. FTG: UNFIN BASEMENT SQ. FTG: IMPERVIOUS SURFACE FTG: AREA: FINISHED BASEMENT GARAGE SQ. FTG: DECK/COV. PATIO SQ. FTG: 30% SLOPES ON SQ. FTG: PROPERTY: #OF BEDROOMS: CONSTRUCTION TYPE: HEAT SOURCE: SEWER OR SEPTIC? The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling,the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal,state or local laws, codes or ordinances.6) Plans or additional information may be required to be submitted, and subsequently approved before this application can bocessed. Ett SIGNATURE: 1 ilia O DATE: /0��� RECEIVED AN BY�� i si r`! of SPOKANE VALLE\ Method of Payment: 0 Cash 0 Check Mastercard 0 VISA APR4 200 Bankcard#: Expires: VIN#: 'EFIMI CENTER Authorized Signature: 2i1 E3Y -- REVISED 2/15/07 • Y OF 11703 E Sprague Ave Suite B-34 Spokane Valley WA 99206 pS okane ♦509.688.0036 ♦ Fax: 509.688.0037 • . 0Valley © Completed Building and Mechanical Application with: Accurate address, Parcel Number and/or Legal Description, description of work, owner and contractor information, signature and date. © Three (3) sets of plans including Site Plan, elevations, floor plans, foundation plans with details, roof plan, framing plans and details. Show the height of any proposed buildings or accessory structures. © Floor plan for each floor: Dimension to scale(minimum 1/8") and label each room (including sq footage of house and garage on plans) show each level of existing house and square footage of any additions. © Egress windows: Provide at least one window or exterior door approved for emergency escape or rescue from basement and in every room for sleeping. © Floor framing details: Joist type, size, spacing and installation details. EX Roof framing plan and details © Furnace and hot water heater location EIAll header locations: type, size and connections ❑X Foundation plan ❑X Insulation information © Decks and Stairway details All braced wall panel types: show locations and details of installation, including engineered design Smoke detector locations 22" x 30" attic access location 18" x 24" crawl space access One-hour separation detail: between house and garage Sjoi ? ..„,ogoValley EMERGENCY ESCAPE AND RESCUE EGRESS WINDOW *Minimum 20"wide clear opening *Minimum 24"high clear opening *Minimum 5.7 sq ft openable area **5.0 sq ft minimum @ grade floor *Top of sill maximum of 44" above finished floor 34'CLEAR 20"CLEAR MIN i OPENABLE AREA , �5.7SQFTMIN 41"CLEAR (5.0 SQ FT MIN GRADE FLOOR) OPENABLE AREA 24'CLEAR 5.7 SQ FT MIN MIN •` (5.0 SQ FT MIN CO • GRADE FLOOR) • MINIMUM SIZE • MINIMUM SIZE WINDOW WINDOW FOR 20 IN. FOR 24 IN.CLEAR HEIGHT CLEAR WIDTH SILL HEIGHT 44'MAX FLOOR Grade floor opening is a window or other openings located such that the sill height of the opening is not more than 44" above or below the finished ground level adjacent to the opening. WINDOW WELL LADDER EGRESS *Minimum 36" x 36" *At least 12" in width *Minimum 9 sq ft clear floor area *Rungs not more than 18" on center *Top of wall a maximum of 44" above *Minimum 3" toe space the floor of the well *Permanently fixed *A guardrail is not required unless an *Non-combustible exit way adjoins the well. *Shall extend to top of wall *Provide drainage DEEP WELLS *If the top of the window well wall is more than 44" above the floor of the well, either a permanently fixed ladder or stair egress is required. *The ladder or stair may encroach a maximum of 6" into the required clear floor space. LADDER OR STAIR PERMITTED NET CLEAR DIMENSIONS WHEN TO ENCROACH MAXIMUM OF FULLY OPENED TO PROVIDE 6 INCHES INTO REQUIRED 9 SQUARE FEET OF OPENING DIMENSIONS WINDOW WELL LADDER OR STAIR \\\'///` '/// REQUIRED '/// \\\\ , 36'MIN .'/// '//7 `\\. EJ EMERGENCY ESCAPE ///� OR RESCUE OPENING \\"//\\''/// \\\'/// \\\'///\\\W/"\\\'/// • `\\` WITH FINISHED SILL /// HEIGHT BELOW '///\\\\'/7'\\\'///. ADJACENT GRADE •\\\ 36'MIN '/// \\\\ W/ \\\\\\'///\\\"///\\\\ *Where bars, grills, covers, screens or similar devices are installed over emergency escape and rescue openings, they must be openable from the inside without the need of special knowledge or special tools, and the force to open them may not be greater than that required of the opening itself. GUIDELINES Installation of Smoke Alarms in Existing One- and Two-Family Dwellings The Spokane Regional Code Group smoke alarms according to Section R313.1.1. has determined the need to clarify application of requirements as it applies to DISCUSSION: If a kitchen were being smoke alarms within one-and two-family remodeled on a rancher style house, and the dwellings undergoing repairs, alterations, attic were open such that all other rooms were or additions. accessible via the attic, then hardwired, inter connected smoke alarms would be required Section R313.1.1 Alterations, throughout the house in required locations, repairs, and additions. powered from an existing circuit.Additionally, if When interior alterations, repairs, or the same home contained a basement, and additions requiring permits occur, or wiring could be routed through an open kitchen when one or more sleeping rooms are wall, then the basement smoke alarm would added or created in existing dwellings, also be required to be interconnected with the the individual dwelling unit shall be upstairs alarms. provided with smoke alarms located as required for new dwellings; the smoke 2) REPAIRS: New smoke alarms are NOT required alarms shall be interconnected and hard to be added when repairs are performed such wired. as: replacing water heaters, boilers, gas inserts, electrical service equipment, sprinkler systems or 1) ALTERATIONS: New smoke alarms their interior components, miscellaneous are NOT required to be added if, for plumbing repairs, etc., or minor structural repairs example: a plumbing system is such as replacing a deteriorated structural altered, converting drains to ABS, an support. Major structural repairs occurring from electrical system is altered by fire damage, tree falling through roof, lighting replacing the fuse panel with a circuit strikes etc.,WOULD require the smoke alarms breaker panel, a circuit is altered by to be upgraded according to Section R313.1.1. extending it or converting it from one voltage to another, windows are 3) ADDITIONS: This section seems to be fairly changed from wood frame to vinyl, self-explanatory in that additions which etc. affect the actual structure of the building would require smoke alarms according to Section Major alterations like removing or adding R313.1.1. It may be possible that an attached structural members, remodeling a garage addition with no disturbance to the bathroom, or remodeling a kitchen existing structure would NOT trigger the (finished materials removed and framing smoke alarm requirement. Repairs to exterior is exposed), are examples which surfaces of dwellings are exempt from the WOULD trigger the requirements for requirements of this section. .cue City of �.� "4 SPOKANE c"moi. ` ' In Rheney ., r.r : o �1 4jI Pril ��� Deera_ '''i 1 stirrac-cti CONSENSUS OPINION: Hardwired For more information contact the local code interconnection of smoke detectors enforcement agency: would not be required between floors or areas which would require the boring of • Spokane County — (509) 477-3675 structural members within enclosed wall • City of Spokane — (509) 625-6100 or floor assemblies. If however, an open • City of Spokane Valley — (509) 688-0036 chase exists for ductwork or plumbing, • City of Liberty Lake - (509) 755-6700 and provides a readily accessible means • City of Medical Lake - (509) 565-5000 for fishing wiring (alongside ductwork or • City of Cheney (509) - 498-9237 plumbing) from floor to floor or other • City of Deer Park — (509) 276-8802 areas, the smoke alarms could • City of Fairfield — (509) 477-3675 practicably be installed/ hardwired/ • Town of Spangle — (509) 477-3675 interconnected. The removal or • Town of Millwood — (509) 477-3675 rearrangement of insulation is NOT considered removal of finished material. NOTE: Areas not accessible for hardwiring would still require battery operated smoke alarms. Please note that while every effort is made to assure the accruacy of the information contained in this brochure it is not warranted for accuracy. This document is not intended to address all aspects or regulatory requirements for a project and should serve as a starting point for your investigation. For detailed information on a particular project,permit,or code requirement refer directly to applicable file and/or code/regulatory documents or contact the appropriate division or staff. 2006 IRC Sp b l«+t Ten Things You Must Know!! , 5F C 1. R105.2 "Work Exempt From Permit" —Spokane County will maintain the 200 sq/ft threshold for one-story detached accessory structures used as tool and storage sheds,or similar uses. 2. Table R301.5 "Live Loads"—Attic storage is clarified in the footnotes of this table. An example: If two or more adjacent trusses with the same web configuration contain a rectangle 42 inches or greater in height by 24 inches or greater in width, located within the plane of the truss, a 20 psf live load must be appli d to the design of the bottom chord comp nents affected. 3. R319.L5 "Exposed Glued-laminated Timbers" —Those portions of glu-lam timbers that form structural supporLof buildings/structures and are exposed to the weather, and not protected by a roof, eave, or similar covering shall be pressure treated, or naturally durable wood. 4. WAC AMENDMENT R327 "Protection Against Radon" —State adoption of IRC Appendix F for mitigation measures applicable for buildings constructed in "High Radon Potential Counties" (Spokane county). Appendix F, Section AF101.1 (WAC Amendment) no longer permits un-vented (conditioned) crawl spaces. Appendix F further requires passive radon vents to be installed in vented crawl spaces. WAC Amends R408.2, permitting 1:300 sq/ft ratios for ventilating crawl spaces. 5. R406.1 "Foundation Damp-proofing" —Language change removes "habitable or usable spaces", and replaces with "foundation walls that retain earth and enclose interior spaces and floors below grade..." effectively reqniring damp-proofing of crawl space foundation walls. R406.2 similar for water-proofing. 6. R613.2 "Window Sills"—New section requires protection similar to guardrails (4" dia. sphere) for operable portions of windows less than 24 inches above the finished floor, and greater than 72 inches above the adjacent exterior grade or surface below. 7. R702.4.2 Tile Backer Board—Requires cement, fiber-cement, or glass mat gypsum backers for tile installation in tub and shower areas and wall panels in shower areas. 8. R703.2 and Table R703.4 "Water-resistive Barrier"—Felt, or other approved barriers (house wrap) are now required over all exterior wall studs or sheathing, and there is no longer an exception for not requiring such felt/barriers under panel sidings with shiplap joints. 9. R703.8 "Flashing"—The provisions for self-flashing windows (use if the window's mounting flange) has been eliminated. Approved corrosion-resistive flashings must be applied shingle fashion at all door/window openings. R613.1 requires window manufacturers to provide installation/flashing instructions for each window. 10. Washington State Energy Code Section 505.3 "Outdoor Lighting" — Luminaries providing outdoor lighting and permanently to residential buildings must be high efficiency (compact fluorescent) bulbs with pin style base. Exception allows incandescent fixtures controlled by motion sensors with integral photo sensors. , . ; ---r,? D (..) c CC NINCyz.Z)V-Q.._ ,)oAk q V ..._________—.....--...._ H---- 4:----N — 'S --- -----------k tfk ,. \ L .,)L.5 ir\-ekrZA,Q ( 1 i ,, 3 0'X '- `• 1 fi) I.t Uj : ,4 6,--0 r-/ / t r rri ,,-- r' l ' ------ - -' ' '1 -------------71 -7 a , _ 9, g .Th oc EMERGENCYFROM IDENTS ROOMS 1)NET CLEAR OPENING: 5.7 SQUARE FEET GRADE FLOOR OPENING IMAX 44`) 5.0 SQUARE FEET 2)NET CLEAR OPENING HEIGHT 24 INCHES 3)NET CLEAR OPENING WIDTH 20 INCHES 4)MAX FINISHED SILL HEIGHT 44"ABOVE FLOOR 5)EMERGENCY ESCAPES RESCUE OPENING SHALL BE OPERATIONAL FROM THE INSIDE OF THE ROOM WITHOUT THE USE OF KEYS OR TOOLS WHEN INTERIOR ALTERATIONS,REPAIRS OR ADDITIONS (/- REQUIRING A PERMIT OCCUR,OR WHEN ONE OR MORE �' SLEEPING ROOMS ARE ADDED OR CREATED IN EXISTING DWELLINGS. THE DWELLING UNIT SHALL BE PROVIDED WITH SMOKE ALARMS LOCATED AS REQUIRED FOR NEW /� �� ry '_ DWELLINGS. t- t' pLAc SMOKE ALARMS SHALL BE INTERCON ,��G'J NECTED AND HARD WIRED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL ALARMS. ‘,L94 (1 (BEDROOMS, AREAS APPROACHING BEDROOMS , RISE OF 24" & ON EACH VAULTED CEILING I LOOK) WITH i r\ r - 7 ,,/ - i / 7 ,\ �__ l r 3(p' y5 r I\: . \:\.. \, \ '-', \ . 1 FtUcJ 7 ( 1 F,v,...,a ,L., ,-,',-, ckiz,-,v., \ii.) -LA __. SSS Lio , „-,45-_,A..) ___c__:)., 14-k-- 5 a!`::on C01t4n. it V(SA 4 1. fe° ?a' 1 701;14: D ' . PROVIDE DIAGRAMS AND ENGINEERING LAYOUTS FOR ROOF TRUSSES, BEAMS AND FLOOR SYSTEMS PRIOR TO FRAMING INSPECTIONS CITY COPY THIS BUBJC TO FIELD INSPECTIONILDING CORRECTIONS *wane • REVIEWED FOR CO "PLIANCE SPOKANE VALLEY=` ILDI�G DIVISION • For City Use Only PLUS Project Number C")%02) tt �� CITY OF I pUkane Project Address RD% YV \,( 4000 Val ley ° �eP y 11703 E Sprague Ave Suite B-3 ♦ Spokane Valley WA 99206 509.688.0036 • Fax: 509.688.0037 ♦ permitcenter@spokanevalley.org As part of our on-going commitment to customer service during the review process of your project application, we are providing you with a TARGET DATE for the initial technical application review. If for any reason we cannot meet this date, we will contact you with a revised target date. Your application review TARGET DATE is H 1O7) The TARGET DATE is the date we estimate your project application will have had its initial technical review. It is not the date for approval or permit issuance. Tips for a Smoother Project Application Review ➢ Submit complete, accurate plans and documents. Extra time may be required for re-submittals as project application reviewers work on multiple applications and it may be several days before they can look at your new or revised information. ➢ Designate a specific contact person to communicate with the City. While the person designated as the applicant's contact person with the City can be changed, one individual with the expertise for dealing with reviewer comments would be the best choice for the entire review process. ➢ Call staff regarding the status of your project only after the target date shown at the top of the page. Although you should be contacted on or by the target date,please feel free to contact us if you haven't heard from us by your target date. Staff may contact you before the target date if the initial review is complete. By following this procedure,you will save time and allow the reviewers to complete the work more expeditiously. Steps in the Permit Process 1. Counter Complete. Your application has been accepted as counter complete. This means all of the required documents, as indicated on your Pre-Application Checklist have been submitted or have been approved for deferred submittal. This does not prevent technical staff from requesting additional information as a result of their technical review. 2. Quality Check. The next step in the process is a quality check to make sure that the application is reviewable and free from substantive flaws that would prevent technical staff from completing the technical review once it is started. When this step is complete, your application will be routed to the appropriate staff and remain in their review queue until it comes up for review. 3. Technical Compliance. Once an application is administratively complete, it is routed to technical staff for compliance review. Depending on the type of project, technical staff may include multiple reviewers. You should be contacted by phone,fax, email,or mail by your TARGET DATE once the initial technical compliance review is complete. 4. Permit Issuance. When the technical compliance review of the application is complete, including any subsequent re- submittals, each reviewer will approve their section of the application and route it to the Permit Center. When all sections of the application are received, a Permit Specialist will process the application and contact the person specified on your application for permit pick-up. Information regarding fees and pre-construction meetings (if required) will be provided by the Permit Specialist at that time. WHITE-APPLICANT PINK-BUILDING FILE REV 9/07 Parcel 45281.03 19 Address 1908 South Whipple Rd. ey©« : ... y < . . . ' > . . . , �... y����� -. �����y . \ w, > w= ����y , * �.» § _ : \ > ^ ® ©. �y y� � ��� G . « » , ()v&c ® .. > , , 6 I § � 2 . . �� .. .a. y � , . . .. , �y-w . . � : = � 2« a . . . a« . . . : 14 4i rits- e-gA�&9 e BY O D tt CITY OF SPO�NE VA L Y APR142O PERMIT C NTER BY