1992, 02-07 Permit App: 92000695 Garage SPOKANE COUNTY DEPARTMENT OF BUILDINGS
W. 1303 BROADWAY AVENUE
SPOKANE,WASHINGTON 99260
(509)456-3675
I certify that I have examined this permit/application,state that the information contained in it and submitted by me or my agent to compile said permit/application is true
and correct, and authorize Spokane County to proceed with processing. In addition, I have read and understand the INSPECTION REQUIREMENTS/NOTICE
provisions included herein and agree to comply with same.All provisions of laws and ordinances governing this type of work will be complied with whether specified
herein or not.I understand that the issuance of this permit/application and any subsequent inspection approvals or Certificates of Occupancy shall not be construed to
give authority to violate or cancel the provisions of any state or local law regulating construction,or as a warranty of conformance with the provisions of any state or local
laws regulating construction.
SIGNATURE OF APPLICATION
OWNER OR AGENT DATE
PROJECT NUMBER= 920 0695 APPLICATION DATE=-• 02 '07'92 PAGE= 01
C 3�•3r• •*** THIS IS NOT A PERMIT *****3i:
PENALTIES WILL. BE ASSESSED FOR COMMENCING WORK WITHOUT A PERMIT
SITE STREET= 2507 5 WHIPPLE RD PARC EL..0=
28544-0207—
ADDRESS= SPOKANE WA 99206
PERMIT USE:.-: DETACHED GARAGE
PLATO= 002392 PLAT NAME= SKYVIEW ACRES ADD?
BLOCK=
"y LOT= 7 ZONE= UR-3.5 DI: T4 F.
AREA== I: /t- F WIDTH:: '1 0 DEPTH::. PO Fit W.. r'}!?
w OF E:+L..DGS= 'i 0 DWELLINGS= I WATER DIST
OWNER= AZZ:INNARO, MICHAEL & T PHONE= 509 928 5507
STREET= 2507 S WHIPPLE RD
ADDRESS":: SPOKANE WA 99206
CONTACT NAME= STAN PHONE NUMBER= 509 927 0655
BUILDING SETBACKS : FRONT= 32 LEFT= 12.0 RIGHT= 10 REAR= 12
:,t.:,;.*•3r3i3ti3k3i3k3E3i3t*3<3e3k3ir 3k3f3t3t•**3r3i••r:**• • REVIEW INFORMATION ****:*•**********x.3i*. * *
DEPARTMENT REVIEW COMMENTS APPROVAL. COMMENTS
BUILDING ; ; ' ' "
F•►t.:K REVIEW ;; ' ; "
III•.I '
P-124.....0 ._.�x�
*. N:3i**•ri***.*.•.3k*3(..**3e3+kR•3t****3I3e BUILDING PERMIT *3E•x.•3i•3d•*3i•* 3{•**3i•3k*;r •***3e. if3
CONTRACTOR= SPOKANE STRUCTURES PHONE= 509 927
0655
S
r-r-
ST REET= 502 N MLtL..L..AN RD '
ADDRESS::: SPOKANE WA 99206
NEW:: X REMODEL= ADDITION= CHANGE OF USE=DWELLt.1NITS : OCC:UF R I..D= BLDG HGT= 10 STORIES=
BLD'C;PARKING=
W X (Di = 20 :'( :3;6p(SQ FT= 120 SPRINKLER=MAT=
REQ PARK ING= 'HANDICAP= SQ CRITICAL t MATS' N(y
DESCRIPTION GROUP TYPE PE FT VALUATION
GARA�';F'Y«.... ........ M-._'...« 4N....«.. 7
0 r776�`i' 00
ITEM DESCRIPTION QUANTITY FEE AMOUNT
----------
RESIDENTIAL VALUATION Y 61 ,00
STATE SURCHARGE 4.50
COUNTY SURCHARGE:: ti 14,58
PERMIT TYPE FEE AMOUNT AMOUNT PAID AMOUNT OWING
BUILDING PERMIT 100,08 0 ? 100.08
q c �l�+ GLORIA
100.08 .00 100.08
PROCESSED I:t BY : WEN'DEL.., GLORIA
PRINTED BY : WENDE I._, GLORIA
*R•**3i*3{N:**i0.3{******3t******A•3ff **** THANK YOU 'R'**3f'*a:**M**•*******r **rti34*•***** •*r;*
s S
NOTICE
It is the responsibility of the permittee, not Spokane County, to see to it that the use described on the front of this permit
complies with applicable codes and requirements and that required inspections are requested. Failure to request required
inspections and obtain the necessary approvals prior to progressing beyond the point where inspections are required may
necessitate removal of certain parts of the construction at the owner's/permittee's expense. At a minimum, the following
inspections ARE REQUIRED by County Code:
1. FOOTING—when forms and reinforcement are in place and prior to placement of concrete.
NOTE:This inspection includes review of the structure's setbacks from property lines.Minimum setbacks are
established by County zoning regulations.Typically,side and rear yard setbacks are measured from property
lines, while setbacks for yards abutting streets are measured from the property line or the center line of the
roadway right-of-way,whichever provides the greater setback from the center line of the roadway right-of-way.
Curb lines and fence lines are not necessarily indicative of property lines.In some residential areas,the County
can own as much as 20 feet of right-of-way between your property and the actual improved street/curb.The
responsibility to comply with applicable setback provisions lies solely with the permittee—neither Spokane
County nor its authorized representatives assume any responsibility for the verification or location of your
property lines.Please verify their location prior to locating your structure.Failure to properly locate the structure
may require its relocation at the owner's/permittee's expense.
2. FOUNDATION—when forms and reinforcement are in place and prior to placement of concrete.(Blocking fora
manufactured home is required to be inspected prior to the installation of skirting.)
3. FRAMING—after all framing, bracing and blocking is in place,and prior to concealing.
4. INSULATION—prior to the installation of drywall.
5. PLUMBING--after rough-in, before covering, and final.
6. MECHANICAL— rough-in of piping, before covering, metal chimneys before concealment, and final.
7. FINAL—when complete and prior to occupancy and/or use. Please provide 24 hours notice.
NOTE:In addition to inspection of the structure,this inspection includes review of site improvements(typically
depicted on the approved site plan)required by ordinance or as a condition of approval of this permit.Items such
as the installation of fire hydrants,fire department access,on-site drainage("208 swales"),road improvements,
parking,and landscaping are common requirements of a permit/site plan which must be completed prior to final
approval of a building or issurance of a Certificate of Occupancy.
In addition to the above any plumbing or mechanical systems or materials which would be concealed by framing, drywall,
concrete, etc., must be inspected prior to cover. Check with the department for"special inspections" in conjunction with
commercial projects.
CALL 456-3675 FOR INSPECTIONS.
TO INSURE PROMPT SERVICE, PLEASE GIVE 24 HOUR NOTICE.
YOUR INSPECTOR IS
UNDER CERTAIN CIRCUMSTANCES, PARTS OF YOUR PROJECT MAY REQUIRE INSPECTIONS FROM OTHER
AGENCIES:
• road cuts for utilities or drives,State or County Engineer's Office
456-3600
• on-site waste disposal system, Environmental Health District
456-6040
• construction in a flood plain, County Engineer's Office
456-3600
• electrical wiring, State Department of Labor and Industries
456-2792
• sewer connection, County or City Utilities Department
456-3604
EXPIRATION
Unless otherwise noted, this permit will be considered null and void by limitation of the work authorized by the permit is not
commenced or is stopped for a period of 180 days, unless a written request for an extension of the permit is received and
approved by the Building Official prior to expiration.At a minimum an inspection should be requested at least once every 180
days to assure the validity of the permit.A permit may be renewed within one year of the date of expiration for one-half the
original fee, subject to certain limitations—please call us if you have any questions.
MISTAKES?
If you think we've made an error in processing this permit or in conducting inspections pertaining to it, or find erroneous
information in the permit,please bring it to our attention immediately by filing a written request for correction within 10 working
days of discovery.All such requests should be directed to the Department of Buildings at the address found on the face of this
permit.
•
Spokane County
DEPARTMENT •OF BUILDING & SAFETY
A Division of Public Works
INFORMATION WORKSHEET
PARCEL NUMBER: ` • 0 7
STREET ADDRESS: S• a-S0 7 a.A.i��� e.6(
CITY/STATE/SIP: clis O - L/ ( c)--Q
SUBDIVISION: Sky(J,-,c.c� /-�,GG es
BLOCK: LOT:` ;7 ZONE: DISTRICT:
, �
LOT AREA:/?, ( 7A: WIDTH: / SO'
fibDEPTH: 80 R/W:
4 OF BUILDINGS: / # OF DWELLINGS:_ / WATER DISTRICT:
OWNER: (2, W`a A PHONE: 5 0 9 - - SSD
MAILING ADDRESS: S• 0--S07 (AA i�p L go •
CITY/STATE/ZIP: 3V C ' ?9C7110ic
CONTACT: ST, PHONE: �/ - - d(S
SETBACKS: - FRONT: c5'2 LEFT: IX) RIGHT: 10 / REAR: /Z
/
PERMIT USE: Dd,(64s2-ee
it*it*****************#r*******eig**#****+k#r*************************,kir********fir*
BUILDING INFORMATION�� �' 1 /
CONTRACTOR LICENSE NUMBER: Nea l`--� �--' l b
0
CONTRACTOR: Occ- Cf -C(CLi-C// 11 . PHONE: S, - z? -
MAILING ADDRESS: ,° S Uv /A1)(0.� a((7/--e3 ' 5100, Laiqv°6
ARCHITECT/ENGINEER: PHONE: - -
MAILING ADDRESS:
NEW: / REMODEL: ADDITION: CHANGE OF USE:
DWELL UNITS: /
OCCUPANT LOAD: BIIILDING HGT. /0STORIES.•
/
BUILDING DIMENSIONS: ,R_.6 X 3 6) (WIDTH X DEPTH) SQ. FT. : k)
REQUIRED PARKING: I HANDICAP: SEWER N) : HYDRANT:
JOB NAME M1cNREL AZE I iUuwk0
PHONEf 27"- .sv•s-6'T
POKRME ADDRESS s. z.S.01 LU N t a is L.e.
TRUCTURES , IMC. LEGAL DESCRIPTION
N. 502 Mullan Rd. SuiteB 4,Sz - 402O7
Spokane, Washington 99206
(509) 927-0655 `0Dit, IkJE
•
'ISPOKAS 112606
ro'
Site Plan 36'
s'Ew£R
_4: 1
Show 4 0 1 �0
NORTHsk
kn 2.6 24
Z p r,
— — 6 - ,
0
Show streets/alley
Show septic/sewer/drainfield
Show existing buildings
Show proposed building v r
Show setbacks-front.sides.rear r 3I
Show lot size Z s
ZONING CRITERIA - SPOKANE
CITY Fe.rt,
If closer than 3'to property line -need firewall / / ,
Out of rear 30' and closer than 5'- need waiver from neighbor ( S Q l —O. CV RS
Can'tcover more than 50n of rear 25'
Corner lot -building must be 20'from side property line (,(J 1j4 L f'P ZS
60'minimum setback from front property line
Less than 6'from residence - need firewall
Maximum square footage - 1000
COUNTY
If closer than5 to property line - need firewall
10' from septic / drainfield
Less than 6'from residence - need firewall
GENERAL SETBACKS ARE SHOWN BELOW. WILL NEED TO CHECK CODE BOOK AND KNOW WHAT ZONING
YOU RE IN TO BE SURE, MAXIMUM BUILDING SIZE ALSO CHANGES WITH DIFFERENT ZONING.
5'minimum side yard setback
5'minimum rear yard setback
Minimum front and side street setback - 25'from property line or 55'from center of road -whichever
is greater