Loading...
2006, 01-23 Permit: 06000172 Wheel Chair RampProject Number: 06000172 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 01/23/2006 Page 1 of 2 Project Information: Permit Use: WHEEL CHAIR RAMP Contact: SESSIONS, ADAM & SHEILA Address: 4030 S WOODRUFF RD C - S - Z: SPOKANE VALLEY, WA 99206 Setbacks: Front Left: 20 Right: Rear: 30 Phone: (509) 891-2290 Group Name: Site Information: Project Name: Plat Key: 002087 Name: PONDEROSA ACRES 05TH ADD District: West Parcel Number: 45324.2101 Block: Lot: SiteAddress: 4030 S WOODRUFF RD Location:: CSV Owner: Name: SESSIONS, ADAM & SHEILA Address: 4030 S WOODRUFF RD SPOKANE VALLEY, WA 99206 Zoning: UR -3.5 Urban Residential 3.5 Water District: Hold: ❑ Area: .00 Acres Width: 0 Depth: 0 Right Of Way (ft): 0 Nbr of Bldgs: 1 Nbr of Dwellings: 1 Review Information: Permits: Building Permit Contractor: OWNER Firm: OWNER Phone: (000) 000-0000 This Application: Total Project: Description Grp Type Notes Sq Ft Valuation So Ft Valuation DECK OPEN R-3 VB WHEELCH 0 $1,500.00 0 $1,500.00 AIR RAMP Item Description RESIDENTIAL PERMIT FEE Totals: 0 $1,500.00 0 $1,500.00 Units Unit Desc 1 SELECT Fee Amount $69.25 Permit Total Fees: $69.25 Operator: CJJ Printed By: CJJ Print Date: 01/23/2006 Project Number: 06000172 Inv: 1 Notes: Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 01/23/2006 Page 2 of 2 Payment Summary: Permit Type Fee Amount Invoice Amount Amount Paid Amount Owing_ Building Permit $69.25 $69.25 $0.00 $69.25 $69.25 $69.25 $0.00 $69.25 Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: CJJ Printed By: CJJ Print Date: 01/23/2006 Spokane 11707 E Sprague Ave, Suite 106 Permit Center �s`�' Spokane Valley . • 99206 • �ey (509)688-0036 \±: rVet� E Community Development www .s.okanev ! ,o .com JAN 192 Residential Construction Permit Application PERMITNUMBER:&I -4 Z PERMIT FEE: ( . 2S ❑ N � 7 ruction ❑ Accessory Bldg l[J1 o ..t' emodel o Deck Other: bt(rten ) _, r Aare SITE ADDRESS LIO7O LUoertrucP. 5,rrrll4>AP ()r,�Ilrvl k74 9Saocc, ASSESSORS PARCEL NO: LEGAL DESCRIPTION: ?uilklmg,owner Name:Adxnn Se��1Ons i Address://yk �j c.)(N)ar)ri/'U City: `-� ornn) 1pnn Uri (e.� Zip: 9�, Q inn Phone: i9 9-0q9 ;.CSntact Pefson4 , Name: 4-/cxi!/! ' ec A-7(7 Phone: cje9_ 9 G✓ '3.€6.7 Contractor Name: TOTAL HABITABLE SPACE: Address: 2"" FLOOR SQ. FTG: City: Zip: Phone: Fax: Lic No: Exp. Date: City Business Lic No: CONSTRUCTION TYPE: Describe the scope of work in detail: Cost of Project: AlAr. /1/t7 rA LA)( -Lo e r r'ar t 41/4)17,�G, z , / / c3r1 t (bon i'UI(i r d'CC& /0 0. /�G�4-f0. **** *********The following MUST be complete: (write N/A if not applicable)********************** HEIGHT TO PEAK: DIMENSIONS: # OF STORIES: TOTAL HABITABLE SPACE: MAIN FLOOR TO SQ. FTG: 2"" FLOOR SQ. FTG: UNFIN BASEMENT SQ. FTG: IMPERVIOUS SURFACE AREA: FINISHED BASEMENT SQ. FTG: GARAGE SQ. FTG: DECK/COV. PATIO SQ. FTG: 30% SLOPES ON FLROPFRTY: # OF BEDROOMS: CONSTRUCTION TYPE: HEAT SOURCE: (SEWEI3)DR SEPTIC? DISCLAIMER The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling, the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or local laws, codes or ordina - . 6) Plans or additional information may be required to be submitted, and subsequently approved before this applicat Signature ion;oces -d. Date 1719 /0 Co Metho of Payment: (Faxed permit applications will o y be accepted with major bankcard) ❑ Cash 0 Check 0 Mastercard 0 VISA Bankcard #: Expires: VIN#: 0 Other Authorized Signature: REVISED 0252005 Sji&cane �,,uFValley 11707 E Sprague Ave Suite 106 ♦ Spokane Valley WA 99206 509.921.1000 ♦ Fax: 509.921.1008 ♦ cityhall@spokanevalley.org Residential Plan Submittal Minimums ❑ Completed Building & Mechanical application with: Accurate address, Parcel Number and/or Legal Description, description of work, owner and contractor information, signature, and date. ❑ Two sets of plans including Site Plan, elevations, floor plans, foundation plans With details, roof plan, framing plans & details. ❑ Show the height of any proposed buildings or accessory structures. ❑ Floor plan for each floor: Dimension to scale (minimum 1/8") and label each Room (including sq. footage of house and garage on plans) Show each level of existing house and square footage of any additions. ❑ All braced wall panel types: show locations and details of installation, including engineered design. ❑ Egress windows: Provide at least one window or exterior door approved for Emergency escape or rescue from a basement and in every room for sleeping. ❑ Smoke detector locations ❑ 22" X 30" attic access location ❑ 18" X 24" crawl space access: ❑ One-hour separation detail: between house and garage ❑ Floor framing details: Joist type, size, spacing and installation details ❑ Roof framing plan and details ❑ Furnace and hot water heater location. ❑ All header locations: type, size, and connections o Foundation plan O Insulation information 9 if? J,f'21PPecv9 • • 6 r Q th fi tP /Pr cijri IS L khei yi pm i (Minimum depth for frost protection in tfie City of Spokane Valley is 24 inches measured from the bottom of the footing to finish grade. Grade slope away from building a minimum 6 inches in first 10 feet. p ke c..-�` oil proQ,Aed. \o(i axia. out 44Ne SbX1 VaMeToDA1/15 ge:` �j�^k d Jo -al ,n ne.. R311.5.6.3 Handrail grip size. All required handrails shall be of one of the following types or provide equiva- lent graspability. 1. Type I. Handrails with a circular cross section shall have an outside diameter of at least 11/, inches (32 mm) and not greater than 2 inches (51 mm). If the handrail is not circular it shall have a perimeter di- mension of at least 4 inches (102 mm) and not greater than 61/4 inches (160 mm) with a maximum cross section of dimension of 21/4inches(57 mm). 2. Type 11. Handrails with a perimeter greater than 61/4 inches (160 mm) shall provide a graspable finger re- cess area on both sides of the profile. The finger re- cess shall begin within a distance of 3/, inch (19 mm) measured vertically from the tallest portion of the profile and achieve a depth of at least 5/16 inch (8 mm) within 78 inch (22 mm) below the widest por- tion of the profile. This required depth shall con- tinue for at least 3/8 inch (10 mm) to a level that is not less than 134 inches (45 mm) below the tallest por- tion of the profile. The minimum width of the hand- rail above the recess shall be 1'4 inches (32 mm) to a maximum of 234 inches (70 mm). Edges shall have a minimum radius of 0.01 inches (0.25 mm). R311.5.7 Illumination. All stairs shall be provided with il- lumination in accordance with Section R303.6. R311.5.8 Special stairways. Circular stairways, spiral stairways, winders and bulkhead enclosure stairways shall comply with all requirements of Section R311.5 except as specified below. R311.5.8.1 Spiral stairways. Spiral stairways are per- mitted, provided the minimum width shall be 26 inches (660 mm) with each tread having a 71/2 -inches (190 mm) minimum tread depth at 12 inches from the narrower edge. All treads shall be identical, and the rise shall be no more than 91/2 inches (241 mm). A minimum headroom of 6 feet 6 inches (1982 mm) shall be provided. R311.5.8.2 Bulkhead enclosure stairways. Stairways serving bulkhead enclosures, not part of the required building egress, providing access from the outside grade level to the basement shall be exempt from the require- ments of Sections R311.4.3 and R311.5 where the maxi- mum height from the basement finished floor level to grade adjacent to the stairway does not exceed 8 feet (2438 mm), and the grade level opening to the stairway is covered by a bulkhead enclosure with hinged doors or other approved means. R311.6 Ramps. R311.6.1 Maximum slope. Ramps shall have a maximum slope of one unit vertical in eight units horizontal (12.5 -per- cent slope). R311.6.2 Landings required. A minimum 3 -foot -by -3 -foot (914 mm by 914 mm) landing shall be provided: 1. At the top and bottom of ramps, 2. Where doors open onto ramps, 3. Where ramps change direction. BUILDING PLANNING R311.6.3 Handrails required. Handrails shall be provided on at least one side of all ramps exceeding a slope of one unit vertical in 12 units horizontal (8.33 -percent slope). R311.6.3.1 Height. Handrail height, measured above the finished surface of the ramp slope, shall be not less than 34 inches (864 mm) and not more than 38 inches (965 mm). R311.6.3.2 Handrail grip size. Handrails on ramps shall comply with Section R311.5.6.3. R311.6.3.3 Continuity. Handrails where required on ramps shall be continuous for the full Length of the ramp. Handrail ends shall be returned or shall terminate in newel posts or safety terminals. Handrails adjacent to a wall shall have a space of not less than 1.5 inches (38 mm) between the wall and the handrails. SECTION R312 GUARDS R312.1 Guards required. Porches, balconies or raised floor surfaces located more than 30 inches (762 mm) above the floor or grade below shall have guards not less than 36 inches (914 mm) in height. Open sides of stairs with a total rise of more than 30 inches (762 mm) above the floor or grade below shall have guards not less than 34 inches (864 mm) in height measured vertically from the nosing of the treads. Porches and decks which are enclosed with insect screening shall be provided with guards where the walking surface is lo- cated more than 30 inches (762 mm) above the floor or grade below. R312.2 Guard opening limitations. Required guards on open sides of stairways, raised floor areas, balconies and porches shall have intermediate rails or ornamental closures which do not allow passage of a sphere 4 inches (102mm) or more in di- ameter. Exceptions: 1. The triangular openings formed by the riser, tread and bottom rail of a guard at the open side of a stairway are permitted to be of such a size that a sphere 6 inches (152 mm) cannot pass through. 2. Openings for required guards on the sides of stair treads shall not allow a sphere 4 3/8 inches (107 mm) to pass through. SECTION R313 SMOKE ALARMS [F] R313.1 Smoke alarms. Smoke alarms shall be installed in the following locations: 1. In each sleeping room. 2. Outside each separate sleeping area in the immediate vi- cinity of the bedrooms. 3. On each additional story of the dwelling, including base- ments but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels, 2003 INTERNATIONAL RESIDENTIAL CODE® 51 R two width between handrails, if provided, shal be 36 inches (914 mm) minimum. 1010.5. Headroom. The minimum he room in all parts of the me s of egress ramp shall not less than 80 inches (2032 mm 1010.5.3 Re rictions. Means of egress ramps shall not re- duce in width 'n the direction of egress travel. Projections into the requi ramp and landing width are prohibited. Doors opening nto a landing shall not reduce the clear width to less than 2 inches (1067 mm). 1010.6 Landings. R s shall 1$ve landings at the bottom and top of each ramp, points f tory g, entrance, exits and at doors. Landings shall compl with Sections 1010.6.1 through 1010.6.5. 1010.6.1 Slope. Landing shall have a slope not steeper than one unit vertical in 48 'units horizontal (2 -percent slope) in any direction. Chan s in level are not permitted. 1010.6.2 Width. a landing shall be at least as wide as the widest ramp run joining landing. 1010.63 Len The landin length shall be 60 inches (1525 min) mum. Exceptio : Landings in non ccessible Group R-2 and R-3 in ' idual dwelling units, as applicable in Section 101.2, permitted to be 36 inces (914 mm) minimum. 1010.6. Change in direction. Where changes in direction of tray occur at landings provided tween ramp runs, the landi g shall be 60 inches by 60 inche (1524 mm by 1524 mm minimum. xcli fdl►g4n V> cc sib Group R-2 and R-3 individual dwelling units, as app able in Section 101.2, are permitted to be 36 inches by 6 inches (914 mm by 914 mm) minimum. 1010.6.5 Doorways. Where doorways are located adjacent to a ramp landing, maneuvering clearances required by ICC A117.1 arepermittedto overlap theemrequired #, landing ►'1r1lt'�/eYlp oN�/ �►�T'I`C fC 1010.7 Ramp constru&tion. All ramps shall be built of materi- als consistent with the types permitted for the type of construc- tion of the building; except that wood handrails shall be permitted for all types of construction. Ramps used as an exit shall conform to the applicable requirements of Sections 1019.1 and 1019.1.1 through 1019.1.3 for vertical exit enclo- sures. 1010.7.1 Ramp surface. The surface of ramps shall be of slip -resistant materials that are securely attached. 1010.7.2 Outdoor conditions. Outdoor ramps and outdoor approaches to ramps shall be designed so that water will not accumulate on walking surfaces. In other than occupancies in Group R-3, and occupancies in Group U that are acces- sory to an occupancy in Group R-3, surfaces and landings which are part of exterior ramps in climates subject to snow or ice shall be designed to minimize the accumulation of same. MEANS OF EGRESS 1010.8 Handrails. Ramps with a rise greater than 6 inches (152 mm) shall have handrails on both sides complying with Section 1009.11. 1010.9 Edge protection. Edge protection complying with Sec- tion 1010.9.1 or 1010.9.2 shall be provided on each side of ramp runs and at each side of ramp landings. Exceptions: 1. Edge protection is not required on ramps not required to have handrails, provided they have flared sides that comply with the ICC A117.1 curb ramp provisions. 2. Edge protection is not required on the sides of ramp landings serving an adjoining ramp run or stairway. 3. Edge protection is not required on the sides of ramp landings having a vertical dropoff of not more than 0.5 inch (13 mm) within 10 inches (254 mm) horizon- tally of the required landing area. 1010.9.1 Railings. A rail shall be mounted below the hand- rail 17 inches to 19 inches (432 mm to 483 mm) above the ramp or landing surface. 1010.9.2 Curb or barrier. A curb or barrier shall be pro- vided that prevents the passage of a 4 -inch -diameter (102 mm) sphere, where any portion of the sphere is within 4 inches (102 mm) of the floor or ground surface. 1010.10 Guards. Guards shall be provided where required by Section 1012 and shall be constructed in accordance with Sec- tion 1012. SECTION 1011 EXIT SIGNS 1011.1 Where required. Exits and exit access doors shall be marked by an approved exit sign readily visible from any direc- tion of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30 480 mm) or the listed viewing dis- tance for the sign, whichever is less, from the nearest visible "-exit sign. Exceptions: 1. Exit signs are not required in rooms or areas which re- quire only one exit or exit access. 2. Main exterior exit doors or gates which obviously and clearly are identifiable as exits need not have exit signs where approved by the building official. 3. Exit signs are not required in occupancies in Group U and individual sleeping units or dwelling units in Group R-1, R-2 or R-3. 4. Exit signs are not required in sleeping areas in occu- pancies in Group I-3. 5. In occupancies in Groups A-4 and A-5, exit signs are not required on the seating side of vomitories or open- ings into seating areas where exit signs are provided in the concourse that are readily apparent from the vomi- tories. Egress lighting is provided to identify each 2003 INTERNATIONAL BUILDING CODE® 207 CITY COPY THIS BUILDING SUBJECT TO FIELD INSPECTION CORRECTIONS REVIEWED FOR CODE COMPLIANCE SPOKANE VALLEY BUILDING DIVISION