2014, 12-17 Permit: BLD-2014-2074 Energy Code Compliance . - VB 356
Property Address: 19417 E 1st Spokane Valley, WA
Conditioned Floor Area: 1152 Date: 12/ 17/ 2014
Builder or registered design professional:
Viking Builders Home Energy Audit Tech
Signature: Ale cptown 509 280 0381
K.Values
Ceiling: Vaulted R- Floors: Over unconditioned space R-
Attic R- 49 Slab on grade floor R- 10
Walls: Above grade R- 21 Doors: Metal R- 6.25
Below,int. R- Glazed R- 3.3
Below,ext. R- Fiberglas R-
U-Factors and SHGC
NFRC rating(or) Windows U- •30 SHGC- N/A
a, ,i, ..> Default rating(Appendix A Vv SFC 2012) Skylights U- SHGC- N/A
Table 406.2 Option(s) 3A <1500 Total 406.2 Credits 5
Heating,Cooling&Domestic Hot Water
System Type Efficiency
Heating Gas forced air 95.2%
Cooling Electric central
DHW - -Gas 50 gal ,,5-6 Cr
Duct&Building Air Leakage
All ducts&HVAC in conditioned space (X/no) Insulation R- 8
Air handler present (yes AN)
Test Target 46 CFM@25Pa Test Result 46 CFM@25Pa
Building air leakage target:ACl150<5.0-Tested leakage:ACH50= 5',D
Onsite Renewable Energy Electric Power System
System type: Rated annual generation Kwh
LOOSE-FILL
INSULATION CERTIFICATE
Part 1. Weatherization Division Eagle Insulation Inc.
Contractor IEEL Form No.8403 Reg# RCE 2647
Viking Builders 11017 N Government Way
Job#356 Hayden, ID 83835
19417 E 1st 208-762-1189
Part 2
Ceiling areas Insulated with fiberglass or loose fill
Square Added Number LBS Per Total Insulation Manufactures
Feet R-Value of bags Bag Depth Type Name
0 38 0 25 10.3" Cellulose Thermoguard
136 49 Fiberglass Knauff
0 Foam Brd R Max
0 19 0 25 5.15" Cellulose Thermoguard
1044 49 67 25 13.3" Cellulose Thermoguard
0 60 0 25 16.1" Cellulose Thermoguard
Part 3 Wall areas insuklated with fiberglass or loose fill
Square Added Number LBS Per Total Insulation Manufactures
Feet R-Value of bags Bag Depth Type Name
8 2" Fiberglass Knauff
100 11 3" Fiberglass Knauff
0 13 3.5" Fiberglass Knauff
O 15 3.5" Fiberglass Knauff
50 19 6.5" Fiberglass Knauff
1048 21 5.5" Fiberglass Knauff
0 13 0 25 3.5" Cellulose Thermoguard
0 21 0 25 5.5" Cellulose Thermoguard
Part 4 Floor ar rim plc'areas!inc.ilatnd with flherglacc or Immo fill
Square Added Number LBS Per Total Insulation Manufactures
Feet R-Value of bags Bag Depth Type Name
O 11 3.5" Fiberglass Knauff
O 13 3.5" Fiberglass Knauff
0 15 3.5" Fiberglass Knauff
O 19 6.5" Fiberglass Knauff
0 21 5.5" Fiberglass Knauff
O 25 8" Fiberglass Knauff
0 30 9" Fiberglass Knauff
O 38 12" Fiberglass Knauff
O 30 0 25 10" Cellulose Thermoguard
Part 5 Foundatio walls insulated with fiberglass or loose fill
Square Added Number LBS Per Total Insulation Manufactures
Feet R-Value of bags Bag Depth Type Name
0 8 2" Fiberglass Knauff
O 11 3.5" Fiberglass Knauff
0 19 6.5" Fiberglass Knauff
Part 6
SQ FT 0 Installed 6 mil vapor barrier in crawler
Yes 1 Meets Washington State work Compliance Sheet
SQ FT 1600 Installed poly vapor barrier on all exterior warm side walls
SQ FT 0 Insulated water pipes R-8
SQ FT 400 Insulated heater plenum and hard ducts with R-8 insulation
40" Baffles 0 Installed cardboard or foam vents at trus heals
60" Baffles 44 Installed cardboard or foam vents at trus heals
Foam Vents 0 Installed cardboard or foam vents at trus heals
Eagle Insulation Inc. certifies that the above residence identifies in part 1 was Insulated,
Inspected by local Building Depts.As specified in part 2,3,4,5 and 6 and the installation was
conducted in performance to applicable codes,standards and regulations at time of
Installation
Authorized Signature Date Installed: 12/8/14