2014, 11-14 Permit: BLD-2014-1738 Energy Compliance Cert=
348
Propetty Address: 14921 E 1st Spokane Valley, WA
Conditioned Floor Area: 2360 Date: 11 / 14 / 2014
Builder or registered design professional :
Viking Builders
Home Energy Audit Tech
Signature:
Ole fitown. 509 280 0381
Ceiling: Vaulted R-
R -Values
Floors: Over unconditioned space R-
30
Attic R- 49 Slab on grade floor R- 10
Walls: Above grade R- 21 Doors: Metal
Below, int. R -
Below, ext. R -
Glazed
Fiberglas
R- 6.25
R-
R -
U -Factors and SHGC
NFRC rating (or) Windows U- .30 SHGC- N/A
Default rating (Appendix A wsrc 2012) Skylights U- SHGC- N/A
Table 406.2 Oplion(sj
5B
Total 406.2 Credits 1.5'
eating, Cooling de Domestic Hot Water
System
Type
Efficiency
Heating
Cooling
Gas forced air
Electric central
95.2%
�-s StcQ-
DHW
50 Heat pump
2.4 EF
Duct & Building Air Leakage
All ducts & HVAC in conditioned space ()(0G / no) Insulation R- 8
Air handler present ( yes ) )
Test Target 95 CFM@25Pa Test Result 93 CFM@25Pa
Building air leakage target: ACHsO < 5.0 - Tested leakage: ACH50 =
Onsite Renewable Energy Electric Power System
System type: Rated annual generation Kwh
4
•
LOOSE-FILL
INSULATION CERTIFICATE
Part 1 Weatherizatlon Division Eagle Insulation Inc.
Contractor IEEL Form No. 8403 Reg#RCE 2647
Viking Builders 11017 N Government Way
Job#348 Hayden,ID 83835
19421 E 1st Ave 208-762-1189
Part 2
Ceiling areas Insulated with fiberglass or loose fill
Square Added Number LBS Per Total Insulation Manufactures
Feet R-Value of baps Bag Deoth Tyoe Name
O 38 0 25 10.3" Cellulose Thermoguard
24 49 Fiberglass Knauff
0 Foam Brd R Max
0 19 0 25 5.15" Cellulose Thermoguard
1394 49 90 25 13.3" Cellulose Thermoguard
0 60 0 25 16.1" Cellulose Thermoguard
Part 3 Wall areas insukiated with fiberglass or loose fill
Square Added Number LBS Per Total Insulation Manufactures
Feet R-Value of bags Bag Depth Type Name
8 2" Fiberglass Knauff
0 11 3" Fiberglass Knauff
0 13 3.5" Fiberglass Knauff
0 15 3,5" Fiberglass Knauff
274 19 6.5" Fiberglass Knauff
1906 21 5.5" Fiberglass Knauff
O 13 0 25 3.5" Cellulose Thermoguard
0 21 0 25 5.5" Cellulose Thermoguard
Part 4 Floor or rim Net areas lncidatad with fiberglass or loose fill
Square Added Number LBS Per Total Insulation Manufactures
Feet R-Vaiue nf hags Rag Depth Type Name
0 11 3.5" Fiberglass Knauff
0 13 3.5" Fiberglass Knauff
0 15 3.5" Fiberglass Knauff
0 19 6.5" Fiberglass Knauff
123 21 5.5° Fiberglass Knauff
O 25 8" Fiberglass Knauff
421 30 9" Fiberglass Knauff
0 38 12" Fiberglass Knauff
O 30 0 25 10" Cellulose Thermoguard
Part 5 Foundatio walls insulated with fillerglass or loose fill
Square Added Number LBS Per Total Insulation Manufactures
Feet R-Value nf hags Rag Depth Type Name
0 8 2" Fiberglass Knauff
O 11 3.5° Fiberglass Knauff
O 19 6.5" Fiberglass Knauff
Part 6
SQ FT 0 Installed 6 mil vapor barrier in crawler
Yes 2 Meets Washington State work Compliance Sheet
SQ FT 3050 Installed poly vapor barrier on all exterior warm side walls
SQ FT 0 Insulated water pipes R-8
SQ FT 150 Insulated heater plenum and hard ducts with 11-8 insulation
40"Baffles 0 Installed cardboard or foam vents at trus heals
60"Baffles 33 Installed cardboard or foam vents at trus heals
Foam Vents 0 Installed cardboard or foam vents at trus heals
Eagle Insulation Inc.certifies that the above residence Identifies in part 1 was insulated,
Inspected by local Building Depts.As specified in part 2,3,4,5 and 6 and the Installation was
conducted in performance to applicable codes,standards and regulations at time of
Installation WI-5
Authorized Signature Date Installed: 10/23/14