Loading...
2015, 04-03 Permit: BLS-2014-2960 Energy Compliance Cert vb 38': Property Address: 19422 E 1St Spokane Valley Conditioned Floor Area: 1662 Date: y / / 15 Builder or registered design professional: Viking Builders Home Energy Audit Tech Signature: le0Btown 509 280 0381 R-Values tzt Ceiling: Vaulted R- Floors: Over unconditioned space R- •r y Attic R- 49 Slab on grade floor R- l C) walls: Above grade R- 21 Doors: Metal R. 6.25 Below,int. R- Glazed R- 3.3 Below,ext. R_ Fiberglas R- U-Factors and SHGC NFRC rating(or) Windows U- .30 SHGC- N/A Default rating(Appendix A WSEC 2012) Skylights U- SHGC- N/A Table 406.2 Option(s) 5B Total 406.2 Credits 1.5 Heating,Cooling&Domestic Hot{hater System Type Efficiency Heating Gas forced air 95% Cooling Electric central 3 sur DHW Electric hybrid 50 gal 2.4 EF Duct&Building Air Leakage ry 8 All ducts&HVAC in conditioned space (x /no) Insulation R- Air handler present (yes/Dtx) Test Target 67 CFM( 25Pa Test Result 54 CFM@25Pa Building air leakage target:ACRS„<5.0-Tested leakage:AChIS„= 2,-7 Onsite Renewable Energy Electric Power System System type: Rated annual generation Kwh LOOSE- FILL INSULATION CERTIFICATE Part 1 Weatherization Division Eagle Insulation Inc. Contractor IEEL Form No. 8403 Reg# RCE 2647 Viking Builders 11017 N Government Way Job# 389 Hayden, ID 83835 19422 E 1st Ave 208-762-1189 Part 2 Ceiling areas Insulated with fiberglass or loose fill Square Added Number LBS Per Total Insulation Manufactures Feet R-Value of bags Bag Depth Type Name 0 38 0 25 10.3" Cellulose Thermoguard 280 38 Fiberglass Knauff 0 Foam Brd R Max 0 19 0 25 5.15" Cellulose Thermoguard 1398 49 90 25 13.3" Cellulose Thermoguard 0 60 0 25 16.1" Cellulose Thermoguard Part 3 Wall areas insuklated with fiberglass or loose fill Square Added Number LBS Per Total Insulation Manufactures Feet R-Value of bans Ban Depth Type Name 8 2" Fiberglass Knauff 0 11 3" Fiberglass Knauff 0 13 3.5" Fiberglass Knauff 0 15 3.5" Fiberglass Knauff 90 19 6.5" Fiberglass Knauff 1196 21 5.5" Fiberglass Knauff 0 13 0 25 3.5" Cellulose Thermoguard 0 21 0 25 5.5" Cellulose Thermoguard Part 4 Floor or rim joist areas insulated With fiberglass or loose fill Square Added Number LBS Per Total Insulation Manufactures Feet R-Value of hags Rag Depth Type Name 0 11 3.5" Fiberglass Knauff 0 13 3.5" Fiberglass Knauff 0 15 3.5" Fiberglass Knauff 0 19 6.5" Fiberglass Knauff 0 21 5.5" Fiberglass Knauff 0 25 8" Fiberglass Knauff 0 30 9" Fiberglass Knauff 0 38 12" Fiberglass Knauff 0 30 0 25 10" Cellulose Thermoguard Part 5 Foundatio walls insulated with fiberglass or loose fill Square Added Number LBS Per Total Insulation Manufactures Feet R-Value of hags Rag Depth Type Name 0 8 2" Fiberglass Knauff 0 11 3.5" Fiberglass Knauff 0 19 6.5" Fiberglass Knauff Part 6 SQ FT 0 Installed 6 mil vapor barrier in crawler Yes 1 Meets Washington State work Compliance Sheet SQ FT 1760 Installed poly vapor barrier on all exterior warm side walls SQ FT 0 Insulated water pipes R-8 SQ FT 420 Insulated heater plenum and hard ducts with R-8 insulation 40" Baffles 0 Installed cardboard or foam vents at trus heals 60" Baffles 51 Installed cardboard or foam vents at trus heals Foam Vents 0 Installed cardboard or foam vents at trus heals Eagle Insulation Inc. certifies that the above residence identifies in part 1 was insulated, inspected by local Building Depts. As specified in part 2,3,4,5 and 6 and the installation was conducted in performance to applicable codes, standards and regulations at time of Installation Authorized Signature Date Installed: 3/9/15