2015, 04-03 Permit: BLS-2014-2960 Energy Compliance Cert vb 38':
Property Address: 19422 E 1St Spokane Valley
Conditioned Floor Area: 1662 Date: y / / 15
Builder or registered design professional:
Viking Builders Home Energy Audit Tech
Signature: le0Btown 509 280 0381
R-Values
tzt
Ceiling: Vaulted R- Floors: Over unconditioned space R-
•r
y Attic R- 49 Slab on grade floor R- l C)
walls: Above grade R- 21 Doors: Metal R. 6.25
Below,int. R- Glazed R- 3.3
Below,ext. R_ Fiberglas R-
U-Factors and SHGC
NFRC rating(or) Windows U- .30 SHGC- N/A
Default rating(Appendix A WSEC 2012) Skylights U- SHGC- N/A
Table 406.2 Option(s) 5B Total 406.2 Credits 1.5
Heating,Cooling&Domestic Hot{hater
System Type Efficiency
Heating
Gas forced air 95%
Cooling Electric central
3 sur
DHW Electric hybrid 50 gal 2.4 EF
Duct&Building Air Leakage
ry 8
All ducts&HVAC in conditioned space (x /no) Insulation R-
Air handler present (yes/Dtx)
Test Target 67 CFM( 25Pa Test Result 54 CFM@25Pa
Building air leakage target:ACRS„<5.0-Tested leakage:AChIS„= 2,-7
Onsite Renewable Energy Electric Power System
System type: Rated annual generation Kwh
LOOSE- FILL
INSULATION CERTIFICATE
Part 1 Weatherization Division Eagle Insulation Inc.
Contractor IEEL Form No. 8403 Reg# RCE 2647
Viking Builders 11017 N Government Way
Job# 389 Hayden, ID 83835
19422 E 1st Ave 208-762-1189
Part 2
Ceiling areas Insulated with fiberglass or loose fill
Square Added Number LBS Per Total Insulation Manufactures
Feet R-Value of bags Bag Depth Type Name
0 38 0 25 10.3" Cellulose Thermoguard
280 38 Fiberglass Knauff
0 Foam Brd R Max
0 19 0 25 5.15" Cellulose Thermoguard
1398 49 90 25 13.3" Cellulose Thermoguard
0 60 0 25 16.1" Cellulose Thermoguard
Part 3 Wall areas insuklated with fiberglass or loose fill
Square Added Number LBS Per Total Insulation Manufactures
Feet R-Value of bans Ban Depth Type Name
8 2" Fiberglass Knauff
0 11 3" Fiberglass Knauff
0 13 3.5" Fiberglass Knauff
0 15 3.5" Fiberglass Knauff
90 19 6.5" Fiberglass Knauff
1196 21 5.5" Fiberglass Knauff
0 13 0 25 3.5" Cellulose Thermoguard
0 21 0 25 5.5" Cellulose Thermoguard
Part 4 Floor or rim joist areas insulated With fiberglass or loose fill
Square Added Number LBS Per Total Insulation Manufactures
Feet R-Value of hags Rag Depth Type Name
0 11 3.5" Fiberglass Knauff
0 13 3.5" Fiberglass Knauff
0 15 3.5" Fiberglass Knauff
0 19 6.5" Fiberglass Knauff
0 21 5.5" Fiberglass Knauff
0 25 8" Fiberglass Knauff
0 30 9" Fiberglass Knauff
0 38 12" Fiberglass Knauff
0 30 0 25 10" Cellulose Thermoguard
Part 5 Foundatio walls insulated with fiberglass or loose fill
Square Added Number LBS Per Total Insulation Manufactures
Feet R-Value of hags Rag Depth Type Name
0 8 2" Fiberglass Knauff
0 11 3.5" Fiberglass Knauff
0 19 6.5" Fiberglass Knauff
Part 6
SQ FT 0 Installed 6 mil vapor barrier in crawler
Yes 1 Meets Washington State work Compliance Sheet
SQ FT 1760 Installed poly vapor barrier on all exterior warm side walls
SQ FT 0 Insulated water pipes R-8
SQ FT 420 Insulated heater plenum and hard ducts with R-8 insulation
40" Baffles 0 Installed cardboard or foam vents at trus heals
60" Baffles 51 Installed cardboard or foam vents at trus heals
Foam Vents 0 Installed cardboard or foam vents at trus heals
Eagle Insulation Inc. certifies that the above residence identifies in part 1 was insulated,
inspected by local Building Depts. As specified in part 2,3,4,5 and 6 and the installation was
conducted in performance to applicable codes, standards and regulations at time of
Installation
Authorized Signature Date Installed: 3/9/15