1992, 03-12 Permit App: 92001495 Residence SPOKANE COUNTY DEPARTMENT (JF?3UILDINGS
W. 130:#BROADWAY AVENUE
SPOKANE,WASHINGTON 99260
(509)456-3675
I certify that 1 have examined this permit/application,state that the information contained in it and submitted by me or my agent to compile said permit/application is true
and correct, and authorize Spokane County to proceed with processing. In addition, I have read and understand the INSPECTION REQUIREMENTS/NOTICE
provisions included herein and agree to comply with same.All provisions of laws and ordinances governing this type of work will be complied with whether specified
herein or not.I understand that the issuance of this permit/application and any subsequent inspection approvals or Certificates of Occupancy shall not be construed to
give authority to violate or cancel the provisions of any state or local law regulating construction,or as a warranty of conformance with the provisions of any state or local
laws regulating construction.
SIGNATURE OF APPLICATION
'OWNER OR AGENT DATE`
44
.3 -?d-
PROJECT NUMBER-- 92001495 APPLICATION DATE= 03/12/92 PAGE= 01
***** THI:S I:S NOT A PERMIT ***** i•
- FIN1LTrtS WILL BEASSESSED FOR COMMENCING--WO»F ... WITHOUT 14 PERMIT
SITE F �` '' 1 1 9�'
E" rr E 6 1 H Aa`E::
PARCEL4= 21541 -2208
ADDRFTT SPOKANE WA 99206
PERMIT USE== RESIDENCE '-• NATURAL. GAS
PLAT: =:: 001845 PLAT NAME== OPPORTUNITY HEIGHTS ADD
BLOCK= LOT= ZC?NE= UR-•3.,5 DIST4= F"
AREA= F'/A= F WIDTH= 85DEPTH= 27' R,W= 400
„: OF BLDGS= :n DWELLINGS= 1 WATER DIST = MODERN
OWNER-: HOMESTEAD CONSTRUCTION PHONE= 509 926 075.5
STREET= 12018 E 1St' AVE" A
ADDRESS= SPOKANE WA 99206
CONTACT NAME:::: CHRIS SWANS ON PHONE NUMBER= 509 926 0755
BUILDING SETBACKS : FRONT= 30 LEFT= 10 RIGHT= is REAR= 215
x•****et**** ••x************* REVIEW INFORMATION ***** ******** ***xx•x:*****
DEPARTMENT REVIEW COMMENTS APPROVAL.. COMMENTS
BUILDING P L..A N REVIEW R E Q U I R E`D i�3 I�-
BUILDING SETBACK REVIEW R E Q U I R E Dr r , 04,4
6 ,/
..
ENGINEER APPROACH/FLOOD PLAIN/DRAINAGE: ..._._..�..... .._ ..
• .*.'**'***x•*****x•**•x•*3***3R••;{iiii•x•* BUILDING PERMIT a • : •*•x*•ur:**•x• •*•* x• **• ***
CONTRACTOR= HOMESTEAD CONSTRUCTION PI•1fi-NE:= 509 926 0755
STREET= 1 '01 B E 1ST AVE"
ADDRESS= SPOKANE WA 99206
NEW= X REMODEL= ADDITION== CHANGE OF USES=
DWEI._i... UNITS= 1 O(:;(:;UF', E_O== BLDG HGT--• STORIES==
BLDG W X D = :t SQ F"T m: 1992 SPRINKLER= N
REQ PARKING= 4HANDICAP:-• CRITI.CAL.. MAT= N
*******************x••ii•********* MECHANICAL. PERMIT *dux•x•***x• #*** :** ***x*•><• :
CONTRACTOR= MARTIN HEET METAS... INC PHONE= 509 924 8080
STREET= '908 N 'SULLIVAN RD 103
ADDRESS:::: SPOKANE. WA 9921 6
*•?ix**•>tix•**xx:*x•***•ri* :*x•ri3t***x•*x PI...iImDI:NG PERMIT ::x•x•xri it******•*•*•ie*ih*•ri. *k*•* ••k:•*•t:*
CONTRACTOR= GOLD SE =iL.. MECHANICAL. INC PHONE= 509 535 5944
STREET= 5524 E" ,:OONE AVE
ADDRESS= SPOKANE WA 99212
PROCESSED BY : WENDEL, GLORIA
PRINTED BY : WENDEL_, GLORIA
x**a:.#*x*x.:**x•*• #xx*xx x*:u* ri.H..A*** THANK YOU .n.**it kx•x :*•a k'•x•x• :*•k** x•*xx•*****.m.. **
e7/. Pu
• .
NOTICE
It is the responsibility of the permittee, not Spokane County, to see to it that the use described on the front of this permit
complies with applicable codes and requirements and that required inspections are requested. Failure to request required
inspections and obtain the necessary approvals prior to progressing beyond the point where inspections are required may
necessitate removal of certain parts of the construction at the ownensipermittee's expense. At a minimum, the following
inspections ARE REQUIRED by County Code
1. FOOTING a-when forms and reinforcement are in place and prior to placement of concrete.
NOTE: Tins inspection inclucJes review of the structure's setbacks from property lines.Mini MU rn setbacks are
established by County zoning regulations. Typically,side and rear yard setbacks are measured from property
lines, tatilie, setbacks for yards abutting streets are measured from the property line or the center line of the
roadway right-of-way,whichever provides the greater setback from the center line of the roadway right-of-way.
Curb lines coo Pence ices are not necessarily indicative of property lines.In some residential areas,the County
•
can own as mutitm as 20 feet of right-of--way between your property and the actual improved street/curb. The
responsibility to comply with applicable setback provisions lies solely with the permittee— neither Spokane
Coni, nor its authorized representatives assume any responsibility tor the verification or location of our
property lines.Please verify their Iocation prior to locating your structure.Failure to properly iocatethe structure
may renuil e its relocation at the owner's/permittee's expense.
2. FOUNDATION--when forms and reinforcement are in place and prior to placement of concrete.(Blocking bra
manufactured home is required to be inspected prior to the installation of skirting.)
3. FRAMING --after ail framing, bracing and blocking is in place, and prior to concealing.
4. INSULATION prior to the installation of drywall.
5. PLUMBING--- after rough-in, before covering, and final.
6. MECHANICAL rough-in of piping, before covering, meta; chimneys before concealment, and final.
7. FINAL---when complete and prior to occupancy and/or use. Please provide 24 hours notice.
NOTE:In addition to inspection of the structure,this inspection includes review of site improvements(typically
depicted on the approved site plan)required by ordinance or as a condition of approval of this permit.items such
as the installation of fire hydrants,fire department access,on-site drainage("208 swales"),road improvements,
parking,and landscaping are common requirements of a permit/site plan which must be compieted prior to final
approval of a building or issurance of a Certificate of Occupancy.
In addition to the above any plumbing or mechanical systems or materials which would be concealed by framing, drywall,
concrete, etc., must be inspected prior to cover. Check with the department for "special inspections" in conjunction with
commercial projects.
CALL 456-3675 FOR INSPECTIONS.
TO INSURE PROMPT SERVICE, PLEASE GIVE 24 HOUR NOTICE.
YOUR INSPECTOR IS
UNDER CERTAIN CIRCUMSTANCES, PARTS OF YOUR PROJECT MAY REQUIRE INSPECTIONS FROM OTHER
AGENCIES:
• road cuts for utilities or drives, State or County Engineer's Office
456-31300
• on-site waste disposal system, Environmental Health District
456-6040
• construction in a flood plain, County Engineer's Office
456-3600
• electrical wiring, State Department of Labor and Industries
456-2792
• sewer connection, County or City Utilities Department
456-3604
EXPIRATION
Unless otherwise noted, this permit will be considered null and void by limitation of the work authorized by the permit is not
commenced or is stopped for a period of 180 days, unless a written request for an extension of the permit is received and
approved by the Building Official prior to expiration.At a minimum an inspection should be requested at least once every 180
days to assure,the validity of the permit. A permit may be renewed within one year of the date of expiration for one-halt the
original fee, subject to certain limitations--- please call us if you have any questions.
MISTAKES?
If you think we've made an error in processing this permit or in conducting inspections pertaining to it or find erroneous
information in the permit,please bring it to our attention immediately by filing a written request for correction within 10 working
days of discovery.Ali such requests should be directed to the Department of Buildings at the address found on the face of this
permit.
- - --- - -
i ellitik
C VP (gUinliter engineertng
.
E . 6620 44th Spokane , Wa_ 99206 - -
Phone 509 926 6217 Fax 509 928 B689
Legend for Radon mitigation system
_ _ __perforated pipe beneath slab
0 solid 4 ABS stack vent pipe
THESE PLANS VE BEEN REVIEWED RADON SYSTEM SPECIFICq TIONS ATT .
BY- kV€k,A,........,.. . ______ 2 - /15---
eN 3-2.7- 92.. RADON MITIGATION SYSTEM
This radon mitigation system is
designed only For the specific Job
�y _ " + - _� sits .ddress dseignstsd . The system
is not guaranteed unless installed
•+ „--,^..._ ____ .....�� by Cavalier Corporation
r RADON VENT Job site address 1) 91'16 . .
eek..
abasement ,F
i _.' builds 0 B Builder s
.�� 1 5O O Sq Ft + J ,. c.,
1��;� i'--.-9 n
...�I . IIS � t: t'v�r` �y
k 411.0,1 if
ti X
War r e i J . i d"',4'e.......;:1.
Environmental Protection Rgencyr�f a,' 44
'1"1 QIatnttir Qitctneertng 4
radon services
•
E. 6620 44th * Spokane, WA 99206
Phone (509) 1 -6217 FAX (509) 928-8689
RADON SYSTEM SPECIFICATIONS, SPOKANE COUNTY:
1 . Perforated pipe shalbe installed within the native soil
or fill (sand, gravel or soil ) at a minimum depth of 1"
below the intended *Nib.
2. The pipe shall be a Siinimum diameter of 4" . meet AASHTO
M252, have perforatisms no wider than 1/16" and have a
minimum of 2.5 square inches of total perforations per
linear foot of pipe.
3. There shall be a min hpum of 10 linear feet of perforated
pipe per hundred square feet of slab floor space.
4 . The pipe shall be laid in a continuous loop. connected at
both ends to the solid stack vent pipe.
5. Any slab area, which is larger than 10 square feet , which
is isolated from othsf slab areas by footings or other
barriers, shall have a perforated pipe installed to the
above specifications. (The pipe can be a single length
rather than a connected loop if the area is too small or
narrow to accomodate a connected loop. )
6. A stack vent of ABS, schedule 40 , minimum size 4" , shall
be connected to the sub-slab piping and proceed upwards
to an exit location es the roof , and extending 14" above
the roof . The pipe shall be labeled "radon vent" every
16" or less for its tell length. The pipe ' s attic
location shall allow a minimum of 4 ' of head room. When-
ever possible this exit location shall be on the backside
of the roof .
7 . Any elbows in the stack vent piping shall have a
centerline radius milimum of 1 . 5 by pipe width.
8. An inline centrifugal fan, minimum 114 cfm C 3/8" W.C. ,
UL listed, manufactured specifically for radon mitigation,
maximum sone level 2.11, shall be installed in the exhaust
line, in the attic.
9 . Couplings to connect the vent piping to the fan shall be
elastomeric PVC, Fero series 1056 or equal .
10. The fan shall be hard-wired and the breaker labeled " radon
fan" .
11 . All penetrations and joints in the concrete floor slab
below grade shall be sealed with caulk or grout .
12. A notice shall be permanently attached to the electrical
panel advising the oseser or occupant about the radon
system and that he/s111 shall test the home for radon
annually. The notioat; shall include Cavalier ' s name and ,
phone number .
13 . All craftsmanship shall be of high quality.