Loading...
2002, 05-14 Permit App: 02003673 ResidenceProject Number: 02003673 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 5/14/02 Page 1 of 3 Project Information: Permit Use: RESIDENCE W/GARAGE - GAS Setbacks: Front 20 Left: 7 Right: 7 Rear: 35 Site Information: Plat Key: 005862 Name: SHELLEY LAKE Parcel Number: 45242.1605 Block: 6 Lot: 5 Contact: LANZCE DOUGLASS INC Address: 8510 N CRESTLINE C - S - Z: SPOKANE WA 99217-7718 Phone: (509) 483-6532 Group Name: Project Name: SiteAddress: 16017 E 5TH LN VERADALE, WA USA 99037 Location:: VER Zoning: UR -3.5 Urban Residential 3.5 Water District: 010 VERA District: F Owner: Name: DOUGLASS, LANZCE Address: 815 E ROSEWOOD AVE SPOKANE, WA 99208-5507 Hold: ❑ Area: 7,757 Sq Ft Width: 67 Depth: 115 Right Of Way (ft): 30 Nbr of Bldgs: 1 Nbr of Dwellings: 1 Review Information: Review Site Plan Review Plan Review Approach / Drainage Sewer Review a,Qj d(J eij Permits: Operator: JAS Printed By: JAS Release 4441111 Released By: Released By: Released By: 12•0` Print Date: 5/14/02 Project Number: 02003673 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 5/14/02 Page 2 of 3 Contractor: LANZCE G DOUGLASS, INC Address: 8510 N CRESTLINE SPOKANE, WA 99217 Const Category: New Nbr Of Dwellings: Bldg W x D: 56 x Req Parking: Building Permit Firm: LANCZE G DOUGLASS, INC Phone: (509) 483-6532 Building Characteristics Group: R-3 Type: VN 1 Occupant Load: 24 Building Sq Ft: Handicap Parking: Description Grp BASEMENT U R-3 DECK R-3 GARAGE U-1 RESIDENCE R-3 Im Notes VN VN VN VN Item Description RESIDENTIAL VALUATION STATE SURCHARGE RESIDENTIAL SURCHARGE Building Height: 1872 Sprinklers: LI Critical Materials: ❑ This Application: Stories: 1 Total Project: Sq Ft Valuation Sq Ft Valuation 936 $11,512.80 936 $11,512.80 120 $939.60 120 $939.60 480 $5,760.00 480 $5,760.00 936 $61,776.00 936 $61,776.00 Totals: 2,472 $79,988.40 2,472 $79,988.40 Units Unit Desc 1 Y OR BLANK 1 Y OR BLANK 1 Y OR BLANK Contractor: DANCAR MECHANICAL INC. Address: 311 N HODGES RD GREENACRES, WA 99016 Item Description GAS WATER HEATER GAS APPLIANCE<=100,000BTU GAS PIPING VENTILATING FANS CLOTHES DRYER GAS LOG OR GAS INSERT Fee Amount $767.50 $4.50 $168.85 Permit Total Fees: $940.85 Mechanical Permit Firm: DANCAR MECHANICAL INC. Phone: (509) 924-9921 Units Unit Desc 1 NUMBER OF 1 NUMBER OF 3 # OF UNITS 4 NUMBER OF 1 NUMBER OF 1 NUMBER OF Permit Total Fees: Fee Amount $10.00 $12.00 $3.00 $40.00 $10.00 $10.00 $ 85.00 Operator: JAS Printed By: JAS Print Date: 5/14/02 Project Number: 02003673 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 5/14/02 Page 3 of 3 Contractor: GOLD SEAL MECHANICAL INC Address: 5524 E BOONE AVE SPOKANE, WA 99212 Item Description TOILETS/BIDETS SINKS TUBS DISH WASHERS GARBAGE DISPOSAL CLOTHES WASHER CROSS CONNECTION DEVICES WATER USING DEVICES Plumbing Permit Firm: GOLD SEAL MECHANICAL INC Phone: (509) 535-5944 Units Unit Desc 2 NUMBER OF 3 NUMBER OF 1 NUMBER OF 1 NUMBER OF 1 NUMBER OF 1 NUMBER OF 1 NUMBER OF 3 NUMBER OF Fee Amount $12.00 $18.00 $6.00 $6.00 $6.00 $6.00 $6.00 $18.00 Permit Total Fees: $78.00 Notes: OCCUPANCY IS DENIED ON ALL LOTS UNTIL FURTHER NOTICE FROM DIV. OF UTILITIES PER GENE REPP 3/26/97 CKF OK TO ISSUE SEWER PERMITS FOR: BLOCK 2 - LOTS 3 THROUGH 10 & 1, 2 BLOCK 3 - LOTS 1 THROUGH 7 BLOCK 4 - LOTS 1 THROUGH 4 BLOCK 5 - LOTS 2 THROUGH 6 & 19 BLOCK 6 - LOTS 1 THROUGH 10 Payment Summary: Permit Type Building Permit Mechanical Permit Plumbing Permit Fee Amount $940.85 $85.00 $78.00 $1,103.85 Invoice Amount $940.85 $85.00 $78.00 $1,103.85 Amount Paid $0.00 $0.00 $0.00 $0.00 Amount Ovvinw $940.85 $85.00 $78.00 $1,103.85 Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be contrued to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: JAS Printed By: JAS Print Date: 5/14/02 FILE: C:\\WATTDATA\\LDOUGDLD.WS HOUSE ID: L.DOUGLAS SPLIT site, 3c3 Spokane. WA ( ) -omeowner: Builder: Lanzce Douglas (509)483-6532 Analyst: TAS Jurisdiction: Utility: WWP House Type: Single Family Weather Data: Spokane. WA Climate Zone: 2 Th1 e:PROPOSEDd signCOMPL EStw tiiY193yWA State ergy�Code., .• 'COMFQNENTIPERFORMANC 1=STER Y ABUDGET�� REFERENCE 82 t99rJ PROPOSED 807 Btu/hr-F 10.03 kWh/ft2-yr REFERENCE DESIGN Component BG Wall 3.5' BG Slab 3.5' Floor Glazing @15% Doors AG Wall Ceiling, Attic Infiltration Reference Value X Area = UA U-0.041 F-0.640 U-0.029 U-0.600 U-0.400 U-0.062 U-0.031 ACH-0.350 420 120ft 86 272.1 21.0 1378 950 12352ft3( 17.2 76.8 2.5 163.3 8.4 85.4 29.4 74.8) Reference UA 383 PROPOSED DESIGN COMPONENTS Component Description Value X Area = UA BG Wall BG Slab BG Wall BG Slab Floor Glazing Q11% aRO U ^s '1'atet}r3,F5�'yyfrdepf_t, W't d:d�SL4M���MYNit.r'si�:le..1':.�.+� R30 vented Joist 1.69,c„,.„ "gIa�e Vi y23 4 aispace U-0.271 F-0.511 U-0.058 F-0.615 U-0.029 Sr` 322 izgal9 gaiftr 157.8 87.3 47.0 5.7 17.2 2.5 80.5 Items in parentheses not included in COMPONENT PERFORMANCE totals. ** Denotes non-standard values - check calculation of thermal value. Page 1 -- FILE: C:\\WATTDATA\\LDOUGDLD.WS HOUSE ID: L.DOUGLAS SPLIT **2 -glaze vinyl patio 3/4" U-0.510 35.0 17.9 Doors **Metal 1-3/4"urethane'raised panel U-0.170 21.0 3.6 AG Wall R19 INT T1-11 U-0.061 1457 88.9 Ceiling R38 blown Attic STD baffled U-0.031 950 29.4 Infiltration Standard Air Sealing ACH-0.350 12352ft3 ( 74.8) Proposed UA 380 Struc Mass Light Frame. Sheetrock walls M- 3.000 950 2850 Slab w/carpet w/pad, Sheetrock wall M- 5.000 864 4320 HEATING/COOLING/VENTILATING SYSTEMS Heating System Type: Make: Model: PROPOSED Gas Furnace unknown/ unknown/ System Efficiency: -80 % Modified Efficiency: 76 % Design ACH: Design Load(at 66F dt): Duct Losses(% Dsn Load): Total Load: System Size: 0.60 34382 Btu/hr 0 Btu/hr( 0%) 34382 Btu/hr 51500 Btu/hr (150%) Average Annual Heat: 81 MBtu Annual Cost: g 452 Ventilation System: Integrated w/Forced Air Furnace Cooling System: SEER: Cooling Load(at 12F dt): System Size( %Over ): Annual Cool Requirement: 0.0 (Unducted) 23612 Btu/hr 2.7 tons(@125%) *** kWh/yr Solar Access: Partially Shaded PROPOSED DUCT SYSTEM SUPPLY RETURN Location Avg Rvalue Surface Area All in heated space All in heated space Page 2 FILE: C.\\WATTDATA\\LDOUGDLD.WS HOUSE ID: L.DOUGLAS SPLIT GLAZING ORIENTATION PROPOSED PROPOSED South ft2 North ft2 Southeast : Northwest : East 109.8 West 83.0 Northeast : Southwest . Economic and energy consumption estimates are designed for comparative purposes only. Actual cost for heating will vary depending on weather conditions, occupant lifestyle and other factors. Page 3 -- d 7 0. d 0 APPLICATION INFORMATION What is the JOB SITE address? ASSESSORS tax parcel number? Legal description as it appears on the, property deed• sh,�,liey�/-1-12-e--2---- 1 � OS 'LOT 5—BLOCK OWNER or OCCUPANT `Lanzce G. Douglass, Inc. Mailing address '815 E. Rosewood Ave. Phone '509-483-6532 City, state Spokane; WA Zip 99208-5507 Who should we contact regarding this project? 'Lanzce'G. Douglass, Phone ' 509-483-6532 What work is being done under this permit? Single Family Tnspecior district Property size p... Building(..,, Contractor Lanzce G. Douglass, Inc. WA State Contractor Ilcense # LANZCGD072P5 OE ENitGY , E?CULAtQ1S Building height Dimensions # of stories 56x24 TOTAL SQUARE FOOTAGE 1872 Main floor area 936 Unfinished basement area 936 Mailing address 815 E. Rosewood Ave. 2nd floor area 0 Architect/Engineer Independent' Home Designs What is the heat source? 1 forreil air Garage area 480 Finished basement area 0 at a 7 Y 0. d 3 Size of decks, etc. • 120 Oover3brr What is the cost of your project? , Manufactured Home: Sign Width: Year: RECERgh. SPOKANF COUNTY Make: MAY 13 What is the square footage of the sign face? How high is the sign? 2002 BUILDING ANDCODEENFORCtMENT Wa State Conti -era license Installer Contractor Wa State Contractor license # Mailing address Mailing address Relocation.:::;; Fire Safety Previous address Fire Sprinkler Paint booth _ Fire Alarm _ Fireworks display Tent VALUE Contractor Contractor WA State Contractor license # WA Stale Contractor Ilcense # Mailingaddress ' Mailing address Full `StoPage`Tanks Swirtinling' Pool (Circle one') Above=ground -Underground s Size / gallons Contents of tank() Size / gallons Private Public/semi-private Contractor Contractor Wa State Contractor license # WA State Contractor license # Mailing address Mailing address COMPLETE ALL APPLICABLE INFORMATION Spokane County does not discriminate on the basis of disability in the admission to, or treatment or employment in, its programs or activities. MECHANICAL PERMIT APPLICATION PROJECT ADDRESS: er OWNER: Lanzce G. Douglass. Inc. MAILING ADDRESS: 815 E. Ro s ewoo d •• (street) CONTRACTOR: Dancer Mechanical Inc. Spokane. IPHONE1DAV-rIMECONTACr 509-483-6532 WA 99208-5507 (city/state) (0-P) LICENSE:DANCAMIO22C7 PHONE: 924-9921 tq&ILD\tS AUL1lE.00 U11 =s. uv LL ,co ..•-••.+••�•-�, ••-- (street) (city/state) (0-P) DESCRIPTION OF WORK i/ OF UNITS .--n LBW . COST /UNIT I sou+W AMOUNT Bali FUEL BURNING APPLIANCE = or <100.000 1 s 512 - r Bob$ FUEL BURNING APPLIANCE >100,000 515 - s Rot UNLISTED APPLIANCE (ADDITIONAL CHARGE) = or <400,000 - . 550 - s BS UNLISTED APPLIANCE (ADDITIONAL CHARGE) >400,000 5100 - s Bd& USED APPLIANCE (Must meet WSEC's min. AFUE rating) = or <400,000 550 - s Bat USED APPLIANCE (Must meet WSEC's min. AFUE rating) >400,000 5100 - s BOt BOILER/REFRIGERATION 1-100M BTU 512 . s BO! s BOILER/REFRIGERATION 101-500M BTU 520 . Witil BOILER/REFRIGERATION 501-1.000M BTU s 525 - s tit BOILER/REFRIGERATION 1,001-1,750M BTU 535 - $ hitt BOILER/REFRIGERATION +1.750M BTU 560 - Bit GAS LOG, GAS INSERT, AND/OR GAS FIREPLACE - 1 . 510 - 131 Z RANGE - 1 510 - Bid: DRYER - 1 510 - Bra= FUEL BURNING WATER HEATER - 1 = 510 - s Etk MISCELLANEOUS FUEL BURNING APPLIANCE - . 510 - s Wit GAS PIPING (ea. outlet) - * 3 s $1 - s I#I DUCT SYSTEMS - 510 - s B2ofi VENTILATING FANS - * 4 510 - s B2'i. AIR HANDLER (DOES NOT include duct systems) = or <10,000 CFM 512 - s tit AIR HANDLER (DOES NOT include duct systems) >10,000 CFM = 515 - s .9 EVAPORATIVE COOLERS - 510 - s TYPE I HOOD - 550 - s BS TYPE II HOOD - . 510 - s kit: HEAT PUMP/AIR CONDITIONER 0-3 TONS 512 - s lifit AIR CONDMONER 3-15 TONS . 520 - s titi AIR CONDITIONER 15-30 TONS . 525 - $ B247. AIR CONDITIONER 30-50 TONS 535 . .$34 AIR CONDITIONER +50 TONS . 560 - s B3 LPG STORAGE TANK - 510 - s B32:; WOOD OR PELLET STOVE/INSERT - . 525 - s NOTE: MINIMUM PERMIT FEE IS $35.00 IGN ATURE• .��.,.> . Subtotal PLUS: PROCESSING FEE $2$.00 TOTAL PERMIT FEE DUE $ S . Spokane County Division of Building & Planning 1026 W. Broadway • Spokane, WA 99260 Tel. No. (509) 456-3675 • Fax No. (509) 324-3198 • TOD No. (509) 324-3166 Spokane County does not discriminate on the basis of disability in the admission to, or treatment or employment in, its programs or activities. 11I14491W4sl..- PLUMBING PERMIT APPLICATION PROJECT ADDRESS: OWNER: Lanzce G. Dou_lass Inc. MAILING ADDRESS: E o ewood Ave. (street) CONTRACTOR: Gold Seal Mechanical Inc. MAILING ADDRESS: 5524 E . Boone TOILETS SHOWERS (per trap) DISHWASHER CLOTHES WASHER GARBAGE DISPOSAL/GRINDER WATER SOFTENER. ELECTRIC HOT WATER TANKS FLOOR DRAINS ROOF DRAINS/OVERFLOW DRAINS FOUNTAINS, DRINKING WATER PIPING/DRAIN-WASTE-VEN PLUMBING REVERSALS SEWAGE EJECTORS WATER USING DEVICES CROSS -CONNECTION DEVICES INTERCEPTORS MEDICAL GAS (per outlet/bottle station) MISCELLANEOUS FIXTURES NOTE.• MINIMUM PERMIT FEE IS $35.00 ® RESIDENTIAL 0 COMMERCIAL SIGNATURE; (street) BASE, STALL. ON -SHE BUILD LAVS/BASmS, BAR. FLOOR KITCHEN, LAUNDRY, UTILITY, JANITOR, PHOTO. X-RAY, FOOD (PREY/CULINARY/MEAT) (NOTE if gas water tanksee mechanical) AREA, CASE, COIL, TRENCH, CONDENSATE GRINDER, SUMP PUMP ICE AND/OR COFFEE MAKER, HOSE BIB, STEAMER, PROOF CARBONATOR, SWAMP COOLERS VACUUM BREAKER, CHECK VALVE, AND RP.B.P.D. FOR VATS, SUMPS, TANKS, BOILERS, 4 SPRINKLER SYSTEMS NITROUS. OXYGEN Spokane County Division of Building & Planning 1026 W, Broadway Avenue * Spokane, WA 99260 Tel. No. (509) 456-3675 • Fax No. (509) 324-3198 " TDD No. (509) 324-3166 Spokane Count • does not discriminate on the basis of disability in the admission to, or. , or ac treatment or employment oyment in, its programss or activities. tdtuxa.,..41..,.o=. nm PRONE: DAY'l7ME CONTACTS O 9- 4 8 3- (5 3 2 Saokane WA 99208-5507 (city/state) (zip) LICENSE: GOLDSM*290C4 PRONE: • Saokane, WA 99212 (city/state) # OF UNITS MULTI. PLIED BY COST /UNIT AMOUNT 00 O (`I rn rn c1 a V) -rs 0 0 a) • 0 o: 00 Lanzce G. Douglass, Inc. ° 6 Qac eat� Ga �` 1,t° 'e'®rG<t co - se G e •Jaa °4°'ae(' aor ar a �`k.y`te, . �y a ..„4` ..„s. NrsJ�eyo yy1'a g, .44 IV J 3 �a Zzw �w2Lij >_ 000 0Cu < CC U CC