Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
2008, 05-20 Permit App: 08001870 Remodel, Addition
Project Number: 08001870 Inv: 1 Application Date: 5/20/2008 Page 1 of 2 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Project Information: Permit Use: CONVERT GARAGE TO LIVING SPACE/ADD 1 Contact: POHLE,SHERRY LYNN CAR GARAGE Address: 13515 E 7TH AVE C-S-Z: SPOKANE VALLEY,WA 99216 Setbacks:Front Left: Right: Rear: Phone: (509)924-6448 Group Name: Project Name: Site Information Plat Key: 001669 Name: MOORES SURBURBAN HOMES ADD District: Sout Parcel Number: 45221.0720 Block: Lot: SiteAddress: 13515 E 7TH AVE Owner:Name: POHLE,SHERRY LYNN Address: 13515 E 7TH AVE Location::CSV SPOKANE VALLEY,WA 99216 Zoning: R-3 SF Res District Water District: 010 VERA Hold: ❑ Area: 13,001 Sq Ft Width: 0 Depth: 0 Right Of Way(ft): 50 Nbr of Bldgs: 1 Nbr of Dwellings: I Review Information: ,n... r. .. Review Building Plan Review Released By: Originally Released: 5/19/2008 By: tmelbourn Landuse/Zoning/HE Conditions Released By: Originally Released: 5/19/2008 By: mharnois Operator: JD Printed By: JD Print Date: 5/20/2008 Project Number: 08001870 Inv: 1 Application Date: 5/20/2008 Page 2 of 2 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Building Permit Contractor: OWNER Firm: OWNER Phone: (000)000-0000 This Application: Total Project: Description Grp Type Notes Sq Ft Valuation Sq Ft Valuation 1&2 FAMILY R-3 VB 287 $27,262.13 287 $27,262.13 GARAGE U-1 VB 276 $5,244.00 276 $5,244.00 Totals: 563 $32,506.13 563 $32,506.13 Item Description Units Unit Desc Fee Amount RESIDENTIAL PERMIT FEE 1 SELECT $472.05 WSBC SURCHARGE 1 SELECT $4.50 SF PLNS RVW<7999 SQ FT 1 SELECT $188.82 Permit Total Fees: $665.37 Payment Summary: ,: Permit Type Fee Amount Invoice Amount Amount Paid Amount Owing Building Permit $665.37 $665.37 $0.00 $665.37 $665.37 $665.37 $0.00 $665.37 Disclaimer: Submittal of this application certifies the owner(or person(s)authorized by the owner)has both examined and finds the information contained within to be true and correct,and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for,or an approval of,any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: JD Printed By: JD Print Date: 5/20/2008 Permit Center S � �� crrr o� 11703 E Sprague Ave, Suite B-3 po ne Spokane Valley,WA 99206 PERMIT FEE: ' Valley. w. (509)688-0036 FAX: (509)688-0037 ww.spokanevalley.org PERMIT NUMBER: Community Development Residential Construction n New Construction n Accessory Bldg Permit Application 17 Addition/Remodel n Deck Other: SITE ADDRESS: �� 5 - 7---7X _ -' / ,,,z /,,/ ASSESSORS PARCEL NO: if-g:v7--/r 0 7,,,7-.0 LEGAL DESCRIPTION: Building Owner: Contractor Name: l ` Name: 5h fldl d///_ o6�s1 �^ // A Address: Address: . /3�/� �� � ��v.�- /351 � �� � C State: Zip: ccyy Ci / � State: i Zip:97:2/z City: l�D.t �, J'/� /pi 7707/ tyc-Ot�� pa%/y �� 9/ z Phone. q l� Fax: Phone p Fax: 1v�7'r� �'� /07�6 �1� Contractor Lic No: Exp Date: Contact Person City Business Lic.No: Name:6h,r 4i', fth76, Phone: 9:;2?‘f , 4 45'' the scope of work in detail: Cost of Project: �9- c'c' Describe p \ ` (�Jl t1 e e S�w�,C GAS. Y�uz-1o+�G +� 1tJ-�� SPALc 1,,..4�. I\cla g�^-.1. e/ o- �v�-Q-r'�-�(- V Proposed Use: 114+1,-,&o --1- L t- ..._.,in-4-4.-1 **************The following MUST be complete: (write N/A if not applicable)********************** HEIGHT T PEAK: DIMENSIONS: , t.," #OF STORIES: TOTAL HABITABLE SPACE: ka, MAIN FLOOR TO SQ ,t 2"" FLOOR SQ. FTG: UNFIN BASEMENT SQ. FTG: IMPERVIOUS SURFACE FTG: �C3"'� 3 _ AREA: --- fi> it FINISHED BASEMENT GARAGE SQ. FTG: DECK/COV. PATIO SQ. FTG: - 30% SLOPES ON SQ. FTG: _ a 7 ° 0 PROP R #OF BEDROOMS: CONSTRUCTION TYPE: jlEAT S,g U CE:— ( WE R SEPTIC? ------ uw o c A `-'s v\ T c A. `6,-1--- The permitee verifies,acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling,the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal,state or local laws,codes or ordinances. 6) Plans or additional information may be required to be submitte ,and subsequently approved before this application can be processed. . / SIGNATURE: r / /� DATE: �S Method of Payment PI C 1 VALLEY 0 Cash nCheck ❑ Mastercard VISA Bankcard#: Expires: VIN#: MAY 1 9 2008 Authorized Signature: -/Q/2-/-9----' � BY; ?I 1 .Y - R REVISED 2/15/07 L f���.f/�� -_. i SingiAane 11703 E Sprague Ave Suite B-3♦ Spokane Valley WA 99206 ♦509.688.0036 ♦ Fax: 509.688.0037• 410 Valley® pCompleted Building and Mechanical Application with: Accurate address, Parcel Number and/or Legal Description, description of work, owner and contractor information, signature and date. EX Three (3) sets of plans including Site Plan, elevations, floor plans, foundation plans with details, roof plan, framing plans and details. © Show the height of any proposed buildings or accessory structures. ❑X Floor plan for each floor: Dimension to scale(minimum 1/8") and label each room (including sq footage of house and garage on plans) show each level of existing house and square footage of any additions. © Egress windows: Provide at least one window or exterior door approved for emergency escape or rescue from basement and in every room for sleeping. © Floor framing details: Joist type, size, spacing and installation details. ❑X Roof framing plan and details ❑X Furnace and hot water heater location ❑X All header locations: type, size and connections ❑X Foundation plan ❑X Insulation information © Decks and Stairway details All braced wall panel types: show locations and details of installation, including engineered design Smoke detector locations 22" x 30" attic access location 18" x 24" crawl space access One-hour separation detail: between house and garage New proje Pro•1. ct" *42 , Previous pre-app meeting El Transmit al flan revisions El .00.0Valley City of Spokane Valley Transmittal Date: Community Development Monday,May 19,2008 Department 11703 E.Sprague Ave,Suite B3 Spokane Valley,\VA 99206 Phone: 509.688.0036 Site Address: 13515 E 7TH AVE Project Number: 08001870 Parcel Number: 45221.0720 Zoning: UNKN Water District: Fire District: FD 01 Applicant: POHLE, SHERRY LYNN Owner: POHLE, SHERRY LYNN 13515 E 7TH AVE 13515 E 7TH AVE SPOKANE VALLEY, WA 99216 SPOKANE VALLEY, WA 99216 (509) 924-6448 e-mail: e-mail: Contact: POHLE, SHERRY LYNN Occupant: 13515 E 7TH AVE e-mail: SPOKANE VALLEY, WA 99216 (509) 924-6448 i - - e-mail: 3 l L (; �., i _Jr Contractor: OWNER Arch/Engineer: MAY 11! 26X D) e-mail: APPLICATION Project CONVERT GARAGE TO LIVING SPACE/ADD 1 CAR GARAGE Description: Building Landuse Engineer Utilities Health Fire Dist Assessor SITE PLAN 1 PLANS Z \ Please send all plan review and project comments via e-mail to the highlighted individuals. WASHINGTON STATE ENERGY CODE • TABLE 6-2 PRESCRIPTIVE REQUIREMENT S°'1 FOR GROUP R OCCUPANCY CLIMATE ZONE 2 Wall" Wall• Wall• Slab6 V Glazin Glazin U-Factor a a Area I': Wall" Door a Ceiling2Vaulted Above int ext Floors on Option % U-Factor Ceiling Grade Below Below Grade of Floor Vertical Overhead" Grade Grade I. 12% 0.35 0.58 0.20 R-38 R-30 R-21 R-21 R-12 R-30 R-10 II.* 15% 0.35 0.58 0.20 R-38 R-30 RR-19s+ R-21 R-12 R-30 R-10 III. 17% 0.32 0.58 0.20 R-38 R-30 8-198+ R-21 R-12 R-30 R-10 IV. 25% 0.35 0.58 0.20 R-38/ R-30/ R-21 R-15 R-12 0 029 R-1F=004 G/ roup R-1 U 0.031 U=0.034 int? / U U=0.054 and R-2 Occupancies Only V. Unlimited 0.35 0.58 0.20 R-38 R-30 R-19+RR-21 R-12 R-30 R-10 Group R-3 -58 and R-4 Occupancies Only VI. Unlimited 0.30 0.58 0.20 R-49 or R-38 R-21 R-21 R-12 R-30 R-10 Group R-3 R-38 Adv int? and R-4 Occupancies Only / VII. Unlimited 0.32 0.58 0.20 R-38/ R-30/ R-21 R-15 R-12 R-30/0 029 F=104 Group R-1 U=0.031 U=0.034 int? / U and R-2 U=0.054 Occupancies Only * Reference Case 0. Nominal R-values are for wood frame assemblies only or assemblies built in accordance with Section 601.1. 1. Minimum requirements for each option listed. For example,if a proposed design has a glazing ratio to the conditioned floor area of 13%,it shall comply with all of the requirements of the 15%glazing option(or higher). Proposed designs which cannot meet the specific requirements of a listed option above may calculate compliance by Chapters 4 or 5 of this Code. 2. Requirement applies to all ceilings except single rafter or joist vaulted ceilings complying with note 3. 'Adv'denotes Advanced Framed Ceiling. 3. Requirement applicable only to single rafter or joist vaulted ceilings where both(a)the distance between the top of the ceiling and the underside of the roof sheathing is less than 12 inches and(b)there is a minimum 1-inch vented airspace above the insulation. Other single rafter or joist vaulted ceilings shall comply with the"ceiling"requirements.This option is limited to 500 square feet of ceiling area for any one dwelling unit. 4. Below grade walls shall be insulated either on the exterior to a minimum level of R-12,or on the interior to the same level as walls above grade. Exterior insulation installed on below grade walls shall be a water resistant material,manufactured for its intended use,and installed according to the manufacturer's specifications. See Section 602.2. 5. Floors over crawl spaces or exposed to ambient air conditions. 6. Required slab perimeter insulation shall be a water resistant material,manufactured for its intended use,and installed according to manufacturer's specifications. See Section 602.4. 7. Int.denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation. 8. This wall insulation requirement denotes R-19 wall cavity insulation plus R-5 foam sheathing. 9. Doors,including all fire doors,shall be assigned default U-factors from Table 10-6C. 10. Where a maximum glazing area is listed,the total glazing area(combined vertical plus overhead)as a percent of gross conditioned floor area shall be less than or equal to that value. Overhead glazing with U-factor of U=0.40 or less is not included in glazing area limitations. 11. Overhead glazing shall have U-factors determined in accordance with NFRC 100 or as specified in Section 502.1.5. 12. Log and solid timber walls with a minimum average thickness of 3.5"are exempt from this insulation requirement. Effective July 1,2007 34 VA/0 l N1101.3.1—Attic insulation certification required as to .1- I<5 —1 t.A,y R—value or coverage. Markers, attached to trusses or . rafters,required for every 300 sf of attic space with 1 inch high numbers for installed thickness of insulation. CEILING: %2"GWB allowed if perpendicular to rafters or trusses 24"oc and no water based texture used—otherwise 5/8"GWB. Sq Ft pK A tiC wrttiiatsd wit��iP� Portion of roof ama. 5096 in the upper Attic Accessible `.. by2 "x3U" z( feD. W�3et, .tJ EwS t to r, Minimum depth for frost protection in the City of Spokane Valley is 24 inches measured from the bottom of the footing to finish grade. Grade slope away from building a minimum 6 inches in first 10 feet. C- CONCRETE TO COMPLYiTO IRC TABLE 404.1.1(1) FOUNDATION WALLS-3000#PSI — SLABS, GARAGES,CARPORTS PORCHES-3500#PSI ALL FOOTINGS MUST BE CONTINUOUS kf•CL � . E`Jwy1o� o G I I I 1 1 pb� � ±ti1ii_.__ LANDING required on both sides of exit doors with min.size of 3 ft.measured in direction of travel by 3 ft.or width of door if greater,and not lower than 1 '/2 in.below threshold.Landing required at other exterior doors is a minimum size of 3 ft travel _ distance by width of door,and not lower than 7 3/4 in.below c..? ��`,�,� e. distance provided the door does not swing over the landing. c ‘ 5 t. 1t, -meg kE1-440-1.Ss E '"'").L c�z r >a0 01 _.-----,_ I 4 1 1 1 1 t 7C 1 I Ip . 14 c i 1 3 i / .. Imo/ S[.`, 5Z n. l kUti ,� �� ,1 1 ` ! i i VIt r � p . , , , Le , _____,_ ! t PLANNING DEPT. APPROVED BY: . s—//'1.61 DATE: A A s ‘Ns Q.z • P'44\ ; S`15 E ') . IlD 4� t % 3..;?,-2 toy i to 0 o 148 ; / +^ r i� c1 1 .. I fit.-� \aos5 w � t. 4-Haze bl 1 i 1 0 i If Di , 1 /:( e i a A, v sR...e., P ` v R802.10.4 Brace Wall Panel min.48 in,-96 in. R602.10.5 Continuous Wood Structural Panel Sheathing I \ ")1 s 1 5 1 f -. R602.10.6.1 Alternate Brace Wall Panel min.28in.-42in. • C i c Z� R602.10.6.2 Alternate Brace Wall Panel min.l6in.-24in. J SHALL BE INTERCON- \ IBC 2305 Engineered Shear Wall Bracing " HARD WIRED IN SUCH A . ,T THE ACTIVATION OF ONE LL ACTIVATE ALL ALARMS. ?C CI:;1S, AREAS APPROACHING ,a4,, -Tie\ ;,,. t00MG , VAULTED CEILING -.iSE OF 24" & ON EACH FLOOR) r WHEN INTERIOR ALTERATIONS,REPAIRS OR ADDITIONS / i ®1)'i- L -. -` 1-i, „ --- YC. REQUIRING A PERMIT OCCUR.OR WHEN ONE 0R MORE --..__.. 4 --.__ SLEEPING ROOMS ARE ADDED OR CREATED IN EXISTING i DWELLINGS. THE DWELLING UNIT SHALL BE PROVIDED WITH SMOKE ALARMS LOCATED AS REQUIRED FOR NEW +9 , 2 - a to h E 4,8,15-4. 1` DWELLINGS. • 111* EXHAUST FANS E,�RR ]QQ i ( OTECTION AND OPENINGS BETWEEN { '~ DWELLING AND PRIVATE GARAGE SHALL HAVE: �'1�'1 50 - batlitto [ 1)MAT RIALS APPROVED FOR ONE HOUR FIRE RESISTIVE & 1ath)dr5 J( �� CONSTRUCTION ON THE GARAGE SIDE: -rj Z�' ' a k_ _ 0 5/8"TYPE"X"GYP BOARD(HABITABLE SPACE AB0VE)OR i + i 0 1/2"GYP BOARD(RESIDENCE;ATTIC.FLOOR/CEILING) j 2;OPENINGS BETWEEN GARAGE AND RESIDENCE SHALL BE F, 0-) t n -_ ,, ( EQUIPPED WITH SOLID W000 DOOR,SOLID OR HONEYCOMB CORE �, p Washington State Ventilation ��Z��-Q)d"'� i STEEL DOORS NOT LESS THAN 1 3/8",OR 20 MINUTE FIRE RATED f DOORS. 6` and Indoor Air Quality Code I -. -. a source specific and I.- le- _ __` _ whole house ventilation system I _ N\ t 4.u55r<3 1/44,t 0.c.. Under Floor Ventilation VIp C\.0.0,a.-sq,S'j%S I 1 Sq Ft per every 150 Sq Ft of under _ floor space area. 1 ventilating opening shall i " 0,C-• t 1 l 1 1 be within 3 feet of each corner.Openings shall be covered with approved material. I p Radon Mitigation System ���N required with 6 mil ! ov" Vapor Barrier . - '-.1x0 V,-,:48.0... .A. A,` L e. .,/ c ea r ✓mva.:-- .. City of .SPOKANE VALLEY BUILDING DEPARTMENT 11707 E.Sprague Avenue u1 D5,Spokane Valley,Washington 99206-Tel 509-635-C103S-Fax 50945S-0037 Following is a typical o oss-sao5on for a residential garage. It rrey not represent the proposed prciect. If you are using this detail as a por'6on of your plan submittal,please complete the requested informalon in the boxes provided on both sides of this sheet This completed sheet,along with any addi5oral informalon needs to be submitted with your apThca5an and be on site of the lime of inspection. PROTECTION AND OPENINGS BETWEEN NOTE DWELLINGS AND PRiVATE GARAGES SHALL HAVE: Diagonal wall bracing required on each corner and every 25 feet of wall. 1)MATERIALS APPROVED FOR ONE HOUR FIRE Walls within 3 feel of a property be or RESISTIVE CONSTRUCTION ON THE GARAGE SIDE: within 8 feet of a dwelling must be 1 hour . 'W TYPE'X'GYP BOARD(HABITABLE SPACE ABOVE) rated. (5f8"type X'gypsum sheathing 1J2•GYP BOARD(RESIDENCE/ATTIC.FLOOR/CEILING) on both sides of waif). Openings are not 2)OPENINGS BETWEEN GARAGE AND RESIDENCE permitted in these walls. Garages over SHALL BE EQUIPPED WRH SOLID WOOD DOOR,SOUD OR 3,000 sq.ft.require proteclon when HONEYCOMB CORE STEEL DOORS NOT LESS THAN 1 318', closer than 20 feet to the propwly 5ne. OR 20 MINUTE FIRE RATED DOORS. Parapets may be rewired._ ALTERNATE FOUNDATION FOR ...... , 1/8" G ACCESSORY BUILDINGS FROMBE i WEEN EATH I c ENGINEERED TRUSS ■ • 400 SQ.FT.TO 3000 SQ.FT. - 4 -_- •• -•.• -ACING 1 . _a___x @ _O.C. t SECTION A-A AN felt for fce As kt,....i t' dam prole Ion tt_ RcoTa MATERIAE, '4 , Z4 � 3 oAC IQ ' >4 . r `,C;dyL yarn,,,,,t` ROOFING PAPER i i ROOF kl is ! 4I 1SHEATHING ! ‘5j DOUBLE TOP PLATE • SOUD BLOCKING WALL HEIGHT �y '.: '• -1111_llw BETWEEN.TR , 4, n isi. j'[-•- lc g 24 MIN. 60 �v4E "� (2) 4 REBAR • •• ' -- • 1 WALL SHEATHING ,r— C___1361t, I1(..., 2. to @ op O.C. SIDING ;., r i'3,' :'; A ��1‘.9 O S PRESSURE TREATED --;,,'("J".*; . , F., -Z �\ S ci SOLE PLATE 1 i �' },-. r3-ill'COIJCRETE SLAB ' •••s 6'MIN. 6'MIN. •k • al, : ..,\ .___„,,,, ....,... ..-4 Z--,1, r,1--------"T-.4., . . --...- L. ... .—;1, r ; Si;: \ '�I i=• ANCHOR BOLTS —i .;s ••' • '1 '' 24"MIN. 6'MIN. 'i 24"MIN. tfL'7c9'MW. • �_ — .� .•I . ' • -. (r INTO CONCRETE) a~• • , 6'O.C.OR APPROVED l • 6"x12' ANCHOR INSTALLED j I-12`-1 REBAR FOOTING PER MANUFACCTUREA� • *.. °.A #.'it 4* `t(10.0.)7(+1r:y ` t,a. PROVIDE DIAGRAMS AND ENGINEERING LAYOUTS FOR ROOF TRUSSES, BEAMS AND FLOOR SYSTEMS PRIOR TO FRAMING INSPECTIONS CITY COPY THIS BUILDING SUBJECT TO FIELD INSPECTION CORRECTIONS Sra „0,00‘ 1.1ey REVIEWED FOR CO3 - COMPLIANCE SPOKANE VALLEY ELM _)ING IVISION