2011, 03-17 Permit App: 11000483 Duplex Project Number: 11000483 Inv: 1 Application Date: 3/17/2011 Page 1 of 3 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Project Information: Permit Use: NEW DUPLEX W/ATT GAR Contact: HITCHCOCK,BRUCE E/VALKENAAR Address: 3305 S BOWDISH RD C-S-Z: SPOKANE,WA 99206-5918 Setbacks:Front Left: Right: Rear: Phone: (509)993-0133 Group Name: Site Information: Project Name: 14004/14006 O N'sir 40 a.a^ .. �..kti�L"!4,L;#3. t"W ,�,x m:::�rw�r,n.�.c�':„ .a•'•a '- „.;"� .. ,.404acs +t^4 r WNW fefi 4i: r,,:r e+r?'M0,4..mu4'4f ... . .. _ -.;.: Plat Key: Name: Range District: East Parcel Number: 45233.0813 Block: Lot: SiteAddress: 14004 E 8TH AVE Owner:Name: HITCHCOCK,BRUCE E/VALKEN Address: 3305 S BOWDISH RD Location::CSV SPOKANE,WA 99206-5918 Zoning: R-4 SF Res Urban District Water District: 010 VERA Hold: ❑ Area: 17,346 Sq Ft Width: 0 Depth: 0 Right Of Way(ft): 0 Nbr of Bldgs: 0 Nbr of Dwellings: 0 Review Information: Review Building Plan Review Released By: Originally Released: 3/11/2011 By: tmelbourn Other Reviews Released By: ADDRESS Originally Released: 3/2/2011 By: jdavis Landuse/Zoning/HE Conditions Released By: Originally Released: 3/1/2011 By: mpalaniuk Operator: JD Printed By: jmm Print Date: 3/17/2011 Project Number: 11000483 Inv: 1 Application Date: 3/17/2011 Page 2 of 3 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Sewer Review Released By: OK PER BILLY URHAUSEN VIA PHONE CALL Originally Released: 3/17/2011 By: JLMain Permits: a.ta : .r..:.... � i ;; _ta r u arr �x Building Permit Contractor: OWNER Firm: OWNER Phone: (000)000-0000 This Application: Total Project: Description Grp Type Notes Sq Ft Valuation Sq Ft Valuation 1&2 FAMILY R-3 VB 2,362 $238,443.90 2,362 $238,443.90 DECK OPEN R-3 VB 150 $2,250.00 150 $2,250.00 GAR WOOD U-1 VB 851 $16,169.00 851 $16,169.00 Totals: 3,363 $256,862.90 3,363 $256,862.90 Item Description Units Unit Desc Fee Amount RESIDENTIAL PERMIT FEE 1 SELECT $1,872.95 WSBCC SURCHARGE 1 SELECT $4.50 SF PLNS RVW<7999 SQ FT 1 SELECT $749.18 SFR/DUP SITE PLN REVIEW 1 SELECT $50.00 Permit Total Fees: $2,676.63 Mechanical Permit Contractor: OWNER Firm: OWNER Phone: (000)000-0000 Item Description Units Unit Desc Fee Amount GAS WATER HEATER 2 NUMBER OF $22.00 VENTILATING FANS 1 DUCT 6 NUMBER OF $66.00 GAS LOG OR GAS INSERT 2 NUMBER OF $22.00 HOOD-TYPE II 2 NUMBER OF $22.00 Permit Total Fees: $132.00 Operator: JD Printed By: jmm Print Date: 3/17/2011 Project Number: 11000483 Inv: 1 Application Date: 3/17/2011 Page 3 of 3 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Plumbing Permit Contractor: OWNER Firm: OWNER Phone: (000)000-0000 Item Description Units Unit Desc Fee Amount TOILETS/BIDETS 4 NUMBER OF $24.00 SINKS 8 NUMBER OF $48.00 SHOWERS 2 NUMBER OF $12.00 TUBS 2 NUMBER OF $12.00 DISH WASHERS 2 NUMBER OF $12.00 GARBAGE DISPOSAL 2 NUMBER OF $12.00 CLOTHES WASHER 2 NUMBER OF $12.00 Permit Total Fees: $132.00 Payment Summary• -WA Permit Type Fee Amount Invoice Amount Amount Paid Amount Owing Building Permit $2,676.63 $2,676.63 $749.18 $1,927.45 Mechanical Permit $132.00 $132.00 $0.00 $132.00 Plumbing Permit $132.00 $132.00 $0.00 $132.00 $2,940.63 $2,940.63 $749.18 $2,191.45 Disclaimer: Submittal of this application certifies the owner(or person(s)authorized by the owner)has both examined and finds the information contained within to be true and correct,and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for,or an approval of,any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: JD Printed By: jmm Print Date: 3/17/2011 • Community Development Department (Staff Use Only) . Permit Center 'I , 11703 East Sprague Avenue, Suite B-3 PERMIT NUMBER: t\-C) 4 3 SCYF ✓ Spokane Valley, WA 99206 pukane .Tel: (509) 688-0036 PERMIT FEE: Valley Fax: 688-0037 w permitcenitcenterOspokanevalley.orq RESIDENTIAL CONSTRUCTION PERMIT APPLICATION NEW CONSTRUCTION ❑ ADDITION/REMODEL 0 ACCESSORY BUILDING 0 DECKd OTHER (��SITE ADDRESS: 04 O— e 'e..:. . - 6. ASSESSORS PARCEL NO.: 46Z33.04) LEGAL DESCRIPTION: 14004 —0C .5 €0 AVE BUILDING OWNER NAME: SRUC.E 141 TC.14 cock NAME: 12'1.zVC.€ to t 'f 44.k Go c t ADDRESS: h „ s0W'p k Si.,t CC 'RD,cm: CITY: " ! O 1(A1.€ VAI�G� Wilt ilt• ZIP: PHONE: 1151110.1 3 O I 3 FAX: 0.....6660 " CELL: 9°127 . o����1111,3 CONTACT NAME: .RUc. 4 \ 1 c+ke.,Q .,K PHONE: itYgl S . 0 ' +B'2 FAX: .....00°' CELL: girl) 6 0133 CONTRACTOR NAME: liklAb ' 13l20c.4 14 1 Tc-4c..4vGIC MAILING ADDRESS: d� 4SAC Ai.e" c. CITY: STATE: ZIP: PHONE: FAX: CELL: CONTRACTOR LICENSE NO.: ©LOW.Sk, EXPIRES: CITY BUSINESS LICENSE NO.: DESCRIBE THE SCOPE OF WORK IN DETAIL AND INDICATE USE & PROPOSED USE: New vurLE X (ZrSt'ps►JGE ****YOU MUST COMPLETE THE FOLLOWING**** MARK N/A IF NOT APPLICABLE Height to eak: Dim souls: I No. of Stories: � TotaloMabit�b `?. �• h? Space: ZZ Main li or S TFT: 4---Upper Floor SQ FT: Unfinished hed ement SQ Finished Ba ement SQ 236 5.� - FT: 14%. FT: N id Garage SQ FT: Deck/Covered Pa io SQ Impervious urface 30%Slope on e51 �� a FT: J�5/1 SArea: iacc) r. Property: ♦ ijA No. of Bedrooms: 4. Construction Type:\/' f J Heat Source: woe, Sewer or Septic:/6 TOTAL COST OF PROJECT: $ DISCLAIMER The permitted verifies, acknowledges and agrees by their signature that: 1) if this permit is for construction or on a dwelling,the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) The City of Spokane Valley permit is not a permit or approval for any violation of federal, state or local laws, codes or ordinances. 6) Plans or additional information may be required to be submitted and subsequently approved before this application can be processed. Signature Date: Updated 1-11-11 Page 1 of 1 http://www.spokanevalley.org/filestorage/124/938/210/948/1496/Building_Permit=_Residential_11-11-11.doc RESIDENTIAL CHECK LIST DIRECTIONS: Place a check mark in box next to each document required for complete submittal. o SITE PLAN o Property lines and dimensions o Setbacks to property lines o Direction arrow pointing North and orientation to streets ❑ Distance between buildings o Proposed/existing buildings (footprint and dimensions) o Right of way/easement location &sizes ❑ Utilities, septic tank/drain field locations and distances o Driveway approach size and location BUILDING PLANS (3 SETS) (minimum 1/8 inch scale or completely dimensioned) ID Elevations (Fron bear/Sides)with roof peak and wall height including basement: ❑ Foundation Plan (crawlspace, basement or slab on grade): o Footing sizes and locations o Supporting wood cripple walls or beams ❑ Perimeter concrete foundation wall sizes o Thickened concrete pads supporting o Crawlspace ventilation beams or girder trusses O Floor Plan of each level (finished or unfinished)with dimensions: o Floor Joist direction, size and spacing o Window and door location and sizes ❑ Header, beam or concrete lintel sizes o Window well locations if applicable o Brace wall •anel locations o Room usage labels o Water heater and furnace locations 0 Smoke detector locations ❑ Exhaust fan locations o Attic and crawl space access locations o Deck or concrete patio sizes and locations o Fire Wall construction loof Plan: o Engineered truss direction and spacing ❑ Ridge, eave and valley lines ❑ Rafter and over frame direction, size and spacing o Beam and girder size and location ❑ Wall Section Detail including: Roof o Slope/roofing material/underlayment/ice dam protection o Truss or rafter size, spacing &connection o Sheathing size and type o Attic insulation/air space baffle/ventilation Ceiling o Joist size and spacing ❑ Size of ceiling gypsum wall board Wall o Height/top plate/stud size and spacing/sole plate o Siding/exterior house wrap/anchor bolts o Exterior sheathing size and type o Insulation, vapor barrier, gypsum wall board Floor o Joist size and spacing o Sheathing or concrete floor size/insulation Foundation Wall o Concrete or Masonry unit width o Footing bottom to finished ground level depth o Earth to wood separation distance o Horizontal &vertical reinforcement if any Footing o Size o Reinforcement if any Radon o Passive system with 6mil vapor barrier o Active system with 6 mil vapor barrier Miscellaneous Construction Details ❑ Deck: o Floor plan/side view/dimensions o Footings/post/and beam size and locations o Floor Joist/decking direction, size and spacing 0 Stairway tread rise & run and nosing 0 Handrail/Guard height &spacing • � /►� Permit Center SYR 11703E Sprague Ave,Suite B-3 ►�j�� Spokane Valley,WA 99206 PERMIT NUMBER: j`�'�qi (509)688-0036 FAX:(509)688-0037 PERMIT FEE: Community Development www.spokanevalley.org Mechanical Permit Application El Commercial CI Residential SITE ADDRESS: (4 oo T -Dc. i , , Building Owner de „V G L 1 TG R G O G K Name: 5RVcos 14 vre_i+edo/+y Phone: 9 2 . 01,32„Fax: ��0 Address: S ` 1)'!,r RD v1`► City: li 1 i the v State: j/� Zip: Contractor ©GO N C Z �l V V W1"'1 Name: J,_ 1 _. Phone: Fax: Address: S room 6 ArcA ow oat. City: State: Zip: License No: t 4./� il _ City Business Lic: Contact b GO Nitelt Name: Phone: DESCRIPTION OF WORK #OF UNITS X COST = TOTAL AMOUNT 1 FUEL BURNING APPLIANCE Equal to or less than 100,000 X $12.00 = 2 FUEL BURNING APPLIANCE More than 100,000 X $15.00 = 3 UNLISTED APPLIANCE(Additional Fee) Equal to or less than 400,000 X $50.00 = 4 UNLISTED APPLIANCE(Additional Fee) More than 400,000 X $100.00 = 5 USED APPLIANCE(WSEC min.AFUE rating) Equal to or less than 400,000 X $50.00 = 6 USED APPLIANCE(WSEC min.AFUE rating) More than 400,000 X $100.00 ,= 7 BOILER/REFRIGERATION 1-100M BTU X $12.00 = 8 BOILER/REFRIGERATION 101-500M BTU X $20.00 = 9 BOILER/REFRIGERATION 501-1,000M BTU X $25.00 = 10 BOILER/REFRIGERATION 1,001 -1,750M BTU X $35.00 = 11 BOILER/REFRIGERATION More than 1,750M BTU X $60.00 = 12 GAS LOG,GAS INSERT,GAS FIREPLACE 2 X $10.00 = eD 13 RANGE ,Y X $10.00 = 8 14 DRYER X $10.00 = 0 15 FUEL BURNING WATER HEATER IN, X $10.00 = 2,0 16 MISC.FUEL BURNING APPLIANCE X $10.00 = 17 GAS PIPING(each outlet) X $1.00 = 18 DUCT SYSTEMS X $10.00 = 19 VENTILATING FANS &I X $10.00 = 6,0 20 AIR HANDLER(DOES NOT include ducting) Equal to or less than 10,000 CFM X $12.00 = 21 AIR HANDLER(DOES NOT include ducting) Greater than 10,000 CFM X $15.00 = 22 EVAPORATIVE COOLERS X $10.00 = 23 TYPE I HOOD X $50.00 = 24 TYPE II HOOD 2. X $10.00 = 25 HEAT PUMP/AIR CONDITIONER 0-3 TON X $12.00 = 26 AIR CONDITIONER 4-15 TON X $20.00 = 27 AIR CONDITIONER 15-30 TON X $25.00 = 28 AIR CONDITIONER 30-50 TON X $35.00 = 29 AIR CONDITIONER More than 50 TON X $60.00 = 30 LPG STORAGE TANK X $10.00 = 31 WOOD OR PELLET STOVE/INSERT X $10.00 = 32 WOOD STOVE-FREE STANDING X $25.00 = 33 REPAIR&ADDITIONS X $15.00 = 34 VENTILATION SYSTEMS X $12.00 = 35 VENTILATION MECHANICAL EXHAUST X $12.00 = 36 INCINERATOR-RESIDENCE X $19.00 = 37 INCINERATOR-COMMERCIAL X $22.00 = METHOD OF PAYMENT: SUBTOTAL 1 60 ❑CASH IDCHECK ElVISA ElMC EXPIRES: PROCESSING FEE /$35.00 CARD#: VIN: TOTAL PERMIT FEE DUE: I+, 5 OQ AUTHORIZED SIGNATURE: REVISED 8/26/05 Permit Center, z `e � 11703 E Sprague Ave,Snite B-3 PERMIT NUMBER: .0•OValley l Spokane Valley,WA 99206 (509)688-0036 FAX:(509)688-0037 PERMIT FEE: Community Development www.spokanevalley.org Plumbing remit Application r ❑ Commercial gResidential SITE ADDRESS: 1400+ ` oat 1 i t i 4.. E- Building Owner Name: `.�Roc* (4 ,•ryt4c Phone: 1' /0013 Fax: Address: $ .s 0�m,S �"'-^' ■■ City:S D �.IVA L ' State: W A . Zip: Contractor Y Name: (44Phone: Fax: Address: City: State: Zip: License No: ©(42)P / .' City Business Lic: Contact Name: Phone: DESCRIPTION OF WORK _ #OF UNITS X COST = TOTAL AMOUNT 1 TOILETS WATER CLOSET,BIDETS 44 X $6.00 = 2t. 2 URINALS /j X $6.00 , = /j 3 TUBS 'AAri X $6.00 = ` 2. 4 SHOWERS(PER TRAP) BATH,STALL ON-SITE BUILT "2 ,X $6.00 = LAVS/BASINS,BAR,FLOOR,KITCHEN, 5 SINKS LAUNDRY,UTILITY,JANITOR,PHOTO, le) X $6.00 = 48 X-RAY,FOOD,PREP/CULINARY MEAT �'f 6 DISHWASHER 2 ,_X $6.00 = i 7 CLOTHES WASHER 2. X $6.00 ^= /22. 8 GARBAGE DISPOSAL Z. X $6.00 I 9 WATER SOFTENER X $6.00 = 10 ELECTRIC WATER HEATER NOTE: IF GAS,SEE MECHANICAL .00.0"... X $6.00 = AREA,CASE,COIL,TRENCH, 11 FLOOR DRAINS CONDENSATE X $6.00 = 12 ROOF DRAINS/OVERFLOW DRAINS _X $6.00 = 13 FOUNTAINS,DRINKING - , X $6.00 = WATER PIPING/DRAIN-IN WASTE, NSTALLATION,ALTERATION,REPAIR, 14 VENT,PLUMBING,REVERSAL REVERSALS X $6.00 = 15 SEWAGE EJECTOR GRINDER,SUMP PUMP X_ $6.00 = ICE AN/OR COFFEE MAKER,HOSE BIB, 16 WATER USING DEVICE STEAMER X $6.00 = PROOFER,CARBONATOR,SWAMP COOLER VACUUM BREAKER,CHECK VALVE, AND R.P.B.P.D.FOR: VATS,TANKS, 17 CROSS CONNECTION DEVICE BOILERS X $6.00 = GREASE TRAP,SAND TRAP, 18 INTERCEPTORS CHEMICAL HOLDING TANK X $6.00 = 19 MEDICAL GAS(per outlet) NITROUS,OXYGEN X $6.00 = 20 MISCELLANEOUS PLUMBING FIXTURE ,X $6.00 = 21 PRIVATE SEWAGE DISPOSAL/SYS X $20.00 = 22 INDUSTRIAL WASTE INTERCEPTOR X $15.00 = SUBTOTAL 132. METHOD OF PAYMENT: PROCESSING FEE ❑CASH 0 CHECK 0 VISA 0 MC EXPIRES: $35.00 Card# VIN: TOTAL PERMIT FEE DUE: E 7CO AUTHORIZED SIGNATURE: REVISED 8/26/05 • For City Use!Only ,` �t.;, PLUS Project Number �_ CITProject Address SjjTökan e 4000 a e ° 11703 E Sprague Ave Suite B-3 ♦ Spokane Valley WA 99206 509.688.0036 ♦ Fax: 509.688.0037 ♦ permitcenter@spokanevalley.org As part of our on-going commitment to customer service during the review process of your project application, we are providing you with a TARGET DATE for the initial technical application review. If for any reason we cannot meet this date, we will contact you with a revised t rget date. Your application review TARGET DATE is lq A The TARGET DATE is the date we estimate your project application will have had its initial technical review. It is not the date for approval or permit issuance. Tips for a Smoother Project Application Review Y Submit complete, accurate plans and documents. Extra time may be required for re-submittals as project application reviewers work on multiple applications and it may be several days before they can look at your new or revised information. ➢ Designate a specific contact person to communicate with the City. While the person designated as the applicant's contact person with the City can be changed, one individual with the expertise for dealing with reviewer comments would be the best choice for the entire review process. ➢ Call staff regarding the status of your project only after the target date shown at the top of the page. Although you should be contacted on or by the target date,please feel free to contact us if you haven't heard from us by your target date. Staff may contact you before the target date if the initial review is complete. By following this procedure,you will save time and allow the reviewers to complete the work more expeditiously. Steps in the Permit Process 1. Counter Complete. Your application has been accepted as counter complete. This means all of the required documents, as indicated on your Pre-Application Checklist have been submitted or have been approved for deferred submittal. This does not prevent technical staff from requesting additional information as a result of their technical review. 2. Quality Check. The next step in the process is a quality check to make sure that the application is reviewable and free from substantive flaws that would prevent technical staff from completing the technical review once it is started. When this step is complete, your application will be routed to the appropriate staff and remain in their review queue until it comes up for review. 3. Technical Compliance. Once an application is administratively complete, it is routed to technical staff for compliance review. Depending on the type of project, technical staff may include multiple reviewers. You should be contacted by phone, fax, email, or mail by your TARGET DATE once the initial technical compliance review is complete. 4. Permit Issuance. When the technical compliance review of the application is complete, including any subsequent re- submittals, each reviewer will approve their section of the application and route it to the Permit Center. When all sections of the application are received, a Permit Specialist will process the application and contact the person specified on your application for permit pick-up. Information regarding fees and pre-construction meetings (if required) will be provided by the Permit Specialist at that time. WHITE-APPLICANT PINK-BUILDING FILE REV 9/07 \ , .. , \ ( \ . F-----7- PLANNING DEPT. APPRO ED . ...." ., ....... ... ...*, i 7 7 cii i' BY: I *) F 474‘ \ DATE: lb /0011 1 ' 1 \- 04z3 p4_ Fife K ' . liI - 0 ' , I 1 "--- .. 'C) . 16 1 1 . C) •. - 1 rr\..2 I 91 , dai , 1 1 Fut lei:14)4 F,,,,0,-1- y3,4 i 1 -I I 40 x 5 hi \ I ,,, . i 1 I . In i i I ' 1 / t , - / // z , . t,,, — _.---------' I --... 1 ,....„, \.\ . 1 i :F.._1 rc3T) V e ci( seq.' 5774-e I ,a ki..., '' / 7..k. I . _——__ — si --__ - --.-- - ,--- i 1 0 0 2. 0# i-J -- . ,- .- - PROJECT DATA PROJECT NAME; A55E55OR5 PARCEL NUMBER; LOT 2 45233.0513 ADDRE55 LOT 3 45233.0514 ADDRE55 LOT 4 45233.0515 ADDRE55 BUILDING OkNNER NAME; OkNNER ADDRE55; CONTACT NAME; CONTACT PHONE; CONTRACTOR NAME; CONTRACTOR ADDRE55; CONTRACTOR PHONE; ARCHITECT NAME; ARCHITECT ADDRE55 ,ARCHITECT PHONE CIVIL ENGINEER NAME CIVIL ENGINEER ADDRE55 GIYIL ENGINEER PHONE; HITCHCOCK DUPLEXES 14004-14006 E. 8TH. AVE. 14008-14010 E. 8TH. AVE. 14012-14014 E. 6TH. AVE. BRUCE HITCHCOCK 3300 5. BON015H RD. BRUCE HITCHCOCK qq3-0133 SAME A5 OV4NER SAME A5 ONNER 5AME A5 ONNER DON A. HENRICH5 2816 N. ,ARGONNE RD. q3q-g887 5TORHAUG ENGINEERS 510 E. THIRD AVENUE 242-1000 BUILDING DATA LIVING AREA 2362 5F UNITAREA (x2) 11815F CONCRETE PATIO AREA 150 5F GARAGE SPACE 851 5F TOTAL FLOOR AREA (PER BUILDING) 3306 5F PROJECT SHEETS ArRCHITEGTURAL A-1 SITE AND DATA A-2 FOUNDATION PLAN A-3 FLOOR PLAN A-4 ELEVATIONS A-5 SECTION A-6 DETAILS GIYIL COVER AND INDEX GRADING AND F-RO51ON WATER PLAN SEWER PLAN DETAIL SHEET LOT 1 PLANNING DEPT. APPROVED BY: DATE: 3/i4=i I -------------------- i I I pT I-7)3q� i I I I \: LOT 2\ REARYARD \ \ I I \ I W iI 51DEYARD T U 510E 51TE PLAN 56ALE: 1" = 20'-0" Lu W v� w Z 1w r < I� V Q z 0 vZ N < o = 6 (3 w `Q V r 4 �Qz Cc: Lu W ED �m� Lu EDts) ts) des Q z z �m o� O Nin r IL U N w a O Zi Lu W v� w Z < I� V Q z 0 vZ N < o = 6 (3 w V r 4 �Qz Cc: Lu < �m� Lu EDts) ts) des Q Lu v� Z < V W N < a- = 6 z Cc: < Lu des Q z �m o� Nin DATE: 2/13/2011 SCALE: SHEET: A-1