1992, 02-04 Permit App: 92000611 ResidenceSPOKANE COUNTY DEPARTMENT OF BUILDIhgs
W. 1303 BROADWAY AVENUE
SPOKANE, WASHINGTON 99260
(509) 456-3675
I certify that I have examined this permit/application, state that the information contained in it and submitted by me or my agent to compile said permit/application is true
and correct, and authorize Spokane County to proceed with processing. In addition, I have read and understand the INSPECTION REQUIREMENTS/NOTICE
provisions included herein and agree to comply with same. All provisions of laws and ordinances governing this type of work will be complied with whether specified
herein or not.1 understand that the issuance of this permit/application and any subsequent inspection approvals or Certificates of Occupancy shall not be construed to
give authority to violate or cancel the provisions of any state or local law regulating construction, oras a warranty of conformance with the provisions of any state or local
laws regulating construction.
SIGNATURE OF
OWNER OR AGENT DATE
APPLICATION
PROJECT NUMBER= 92000611
APPLICATION DATE= 02/04/92 PACE= 01
*****. THIS IS NOT A PERMIT ******
PENALTIES > W:Ci...L DE ASSESSED FOR COMMENCING WORK WITHOUT A PERMIT
SITE: STREET=: 6007 E 9TH AVE PARCEL.: 24533-07.2
ADDRESS= SPOKANE WA 99212.
PERMIT USE= RESIDENCE ••- NATURAL_ GAS
PLAT4= 000 344 PLAT NAME== CENTRAL RAI_. PARK ADD
BLOCK= 10 1. OT w 20 ZONE"::: UR -3.5 01: S'T4==
AREA= F'/A= F WIDTH= 69 DEPTH= 135 R/W= 60
OF B1._DGS-: :. DWELLINGS= 1 WATER DIST == SPOKANE, CITY OF
.H.
OWNER-: GREER CONSTRUCTION
STREET= 9609 N SEMINOLE RCD
ADDRESS= SPOKANE WA 99208
CONTACT NAME= DEAN GREE:R
PHONE== 509 466 0908
PHONE:: NUMBER= 509 466 0908
BUILDING SETBACKS: FRONT= 25 LEFT= 5 RIGHT= 1 4 REAR= 75
*•*•i{itii****•iii•x*****ik**ii** **•iiri*R•* RE:4I:EW INFORHATT.ON •**********
DEPARTMENT REVIEW COMMENTS APPROVAi. ,OMM Aia_
c�
BUILDING PLANRr REVIEW REQUIRED
v.t. :....__ ....,......a-.`_�....Z."..1.'
BUILDINGfit'
:; l B A c K/O E: 4' I r$: W y t.J C ' E ' Ai Ctke•• i
�.N .,. i� A 'i AAV: 7� 1�' ...Fa- T��1:`4�R :. J.AGEE:
iii"• l! AYIET; NEW OR ADDITIONAi... WASTE WATER
.******30k******************* BUILDING PERMIT *** •• *•!*****
CONTRACTOR= GREE::R CONSTRUCTION
STREET= 9609 N SEMINO1...E ST
ADDRESS= SPOKANE WA 992.08
PHONE.: 509 466 0908
NEW X REMODEL= ADDITION= CHANGE OF USE=::
DWE::L..L.. UNITS= 1 OCCUP. I...0= BLDG HGT= STORIES==
BLDG W X 10 :•w x SQ FT= 1590 SPRINKLER= N
RECD! PARKING= 4 HANDICAP- CRITICAL_ MAT: N
,�
************•***•***..yR.y{..N•****•IE
**y:*************************** �`1r:.C':F•I�'�i~t:Cf.;F•�I._ PERMIT
CONTRACTOR= WAYNE SMITH HEATING PHONE= 509 .320 4431
STREET= 102 r:: NtlI.H AVE
ADDRESS-: SPOKANE WA 99207
*•* *•H:** **>;:i***•*****•i******•***•*** F'L.umBINC; .PFiS'NT"I ***x:'+i•3*4****ii•;***•****•************
CONTRACTOR- GOL...D SEAL MECHANICAL INC; ('HONE== 509 `.> 5 5944
STREET== 5524 I? 14)ONE. AVE: 4
ADDRESS= SPOKANE WA 99212
PROCESSED BY: WENDEL, GLORIA
PRINTED BY: WENDE L, GLORIA
**it•9i..x.. •ii•*****3(..x.**.#.) . *.,A: ii ****•******
THANK YOU
******•. *•i**•*****•**:.(.. ••P.**.****•*****
•
NOTICE
It is the responsibility of the permittee, not Spokane County, to see to it that the use described on the front of this permit
complies with applicable codes and requirements and that required inspections are requested. Failure to request required
inspections and obtain the necessary approvals prior to progressing beyond the point where inspections are required may
necessitate removal of certain parts of the construction at the owner's/permittee's expense. At a minimum, the following
inspections ARE REQUIRED by County Code:
1. FOOTING — when forms and reinforcement are in place and prior to placement of concrete.
NOTE: This inspection includes review of the structure's setbacks from property lines. Minimum setbacks are
established by County zoning regulations. Typically, side and rear yard setbacks are measured from property
lines, while setbacks for yards abutting streets are measured from the property line or the center line of the
roadway right-of-way, whichever provides the greater setback from the center line of the roadway right-of-way.
Curb lines and fence lines are not necessarily indicative of property lines. In some residential areas, the County
can own as much as 20 feet of right-of-way between your property and the actual improved street/curb. The
responsibility to comply with applicable setback provisions lies solely with the permittee — neither Spokane
County nor its authorized representatives assume any responsibility for the verification or location of your
property lines. Please verify their location prior to locating your structure. Failure to properly locate the structure
may require its relocation at the owner's/permittee's expense.
2. FOUNDATION -- when forms and reinforcement are in place and prior to placement of concrete. (Blocking for a
manufactured home is required to be inspected prior to the installation of skirting.)
3. FRAMING -- after all framing, bracing and blocking is in place, and prior to concealing.
4. INSULATION -- prior to the installation of drywall.
5. PLUMBING — after rough -in, before covering, and final.
6. MECHANICAL — rough -in of piping, before covering, metal chimneys before concealment, and final.
7. FINAL -- when complete and prior to occupancy and/or use. Please provide 24 hours notice.
NOTE: In addition to inspection of the structure, this inspection includes review of site improvements (typically
depicted on the approved site plan) required by ordinance or as a condition of approval of this permit. Items such
as the installation of fire hydrants, fire department access, on-site drainage ("208 swales"), road improvements,
parking, and landscaping are common requirements of a permit/site plan which must be completed prior to final
approval of a building or issurance of a Certificate of Occupancy.
In addition to the above any plumbing or mechanical systems or materials which would be concealed by framing, drywall,
concrete, etc., must be inspected prior to cover. Check with the department for "special inspections" in conjunction with
commercial projects.
CALL 456-3675 FOR INSPECTIONS.
TO INSURE PROMPT SERVICE, PLEASE GIVE 24 HOUR NOTICE.
YOUR INSPECTOR IS
UNDER CERTAIN CIRCUMSTANCES, PARTS OF YOUR PROJECT MAY REQUIRE INSPECTIONS FROM OTHER
AGENCIES:
• road cuts for utilities or drives, State or County Engineer's Office
456-3600
• on-site waste disposal system, Environmental Health District
456-6040
• construction in a flood plain, County Engineer's Office
456-3600
• electrical wiring, State Department of Labor and Industries
456-2792
• sewer connection, County or City Utilities Department
456-3604
EXPIRATION
Unless otherwise noted, this permit will be considered null and void by limitation of the work authorized by the permit is not
commenced or is stopped for a period of 180 days, unless a written request for an extension of the permit is received and
approved by the Building Official prior to expiration. At a minimum an inspection should be requested at least once every 180
days to assure the validity of the permit. A permit may be renewed within one year of the date of expiration for one-half the
original fee, subject to certain limitations — please call us if you have any questions.
MISTAKES?
If you think we've made an error in processing this permit or in conducting inspections pertaining to it, or find erroneous
information in the permit, please bring it to our attention immediately by filing a written request for correction within 10 working
days of discovery. All such requests should be directed to the Department of Buildings at the address found on the face of this
permit.
6(1.4)slusa-J Set -e
.Spokane.County
DEPARTMENT OF BUILDING & SAFETY
West 1303 Broadway Avenue Spokane, WA 99260 (509) 456-3675
PARCEL NUMBER:
STREET ADDRESS:
INFORMATION WORKSHEET
Ei 667 /
CITY/STATE/ZIP:
SUBDIVISION:
Cr,tr- 2a -G Pq4. 009-citizA,
BLOCK: /0 LOT:
',L,O ZONE: DISTRICT:
LOT AREA: F/A: WIDTH: DEPTH: R/W:
# OF BUILDINGS: # OF DWELLINGS: WATER DISTRICT:
OWNER:
CQC4 L cis PHONE: - -
MAILING ADDRESS:
CITY/STATE/ZIP:
CONTACT:
DEAN GREER
N. 9699 SEMINOLE
SPOKANE. WA 9920S
PHONE:
SETBACKS: — FRONT: .2.5-
Z LEFT: S RIGHT: Iy REAR: 05 --
PERMIT USE:
****************************************************************************
BUILDING INFORMATION
CONTRACTOR LICENSE NUMBER: (7i{GlJG ) (,3q PO
CONTRACTOR: DEAN GREER PHONE: - 446 - 0207
N. 9609 SEMINULC
MAILING ADDRESS: SPOKANE, WA 88204
ARCHITECT/ENGINEER:
MAILING ADDRESS:
Lobar
PHONE:
NEW: REMODEL:_ ADDITION:_ CHANGE, OF USE:_
DWELL UNITS: / OCCUPANT LOAD: BUILDING HGT: /ti STORIES:y0/.T
^/0 r X .fit. i'
BUILDING DIMENSIONS:
(WIDTH X DEPTH) SQ. FT.: 970
REQUIRED PARKING: # HANDICAP: BPRINKLERED: CRITICAL MATERIAL:
Please provide the following info rt "cation for Energy Code compliance:
Space heating type (check one)
Forced air electric Electric baseboard or wall mount Propane
Forced air gas Heat pump Other:
Flat ceilings R a Doors U
Vaulted ceilings R 30 Windows U e 117
Above grade walls R 1 7 Glazing area /YG %: 670
Below grade walls R )5 Total floor area
Floor R 30 of heated space
Slab on grade FR la/A Furnace efficiency rating &V%
Please indicate on your plans: The location of the radon vent, and the location of the vent fan area.
Square footage
Main floor: /g/y0
Second floor: 450
Basement -Finished: r)/Fl
Unfinished: /Vila
Garage' hit 2-
Carport: etgA
Decks: 8;v •
Additional Areas:
NJ/a
•
Greer Construction
N. 9609 Seminole
Spokane, Wa. 99208
*(509) 466-0908
Wall Construction 2x6
R-19 Wall Insulation
R-38 Ceiling
Northwest Chinook 0500
Gar. Split 960
Proposed Construction
s Constructs un Sq.F IJ Value Delta T BTU Loss
Ceiling - Flat 750 0.026 66.00 1287.00
Ceiling - Tapered 198 0.040 66.00 522.72
Ceiling - Cathedral 0 0.030 66.00 0.00
Floors over unheated spaces 204 0.050 66.00 673.20
Framed Walls Main Floor 992 0.050 66.00 3273.60
Main Floor Windows 95 0.520 66.00 3260.40
Sliding Glass Doors 33 0.580 66.00 1263.24
Entrance Doors 20 0.070 66.00 92.40
Infiltration - Main Floor 7584 0.012 66.00 6006.53
Framed Walls - Basement 624 0.050 46.00 1435.20
Basement Windows 51 0.520 46.00 1219.92
Basement Entrance Doors 18 0.070 46.00 57.96
Basement Sliding Glass Doors0 0.580 46.00 0.00
Concrete Foundation Walls 384 0.862 10.00 3310.08
Concrete Floor 756 0.260 10.00 1965.60
Basement Infiltration @ 46 deg3024 0.012 46.00 1669.25
Basement Infiltration Is 10 deg3024 0.010 10.00 302.40
Total Proposed Heat Loss--------------'- 26339.50
FHA Maximum Allowable Heat Loss --Electric Heat
Ceiling 948 0.026 66.00 1626.77
Floors over unheated spaces 204 0.050 66.00 673.20
Framed Wallc- 1616 0.050 66.00 5332.80
'Windows ih 15% 242 0.470 66.00 7519.25
• Sliding Glass Doors 33 0.691) 66.00 •1502.82
Concrete Foundation Walls 384 0.862 10.00 3310.08
Concrete Floor 756 0.260 10.00 1965.60
Infiltration - Main Floor 7584 0.012 66.00 6006.53
Basement Infiltration @ 46 deg3024 0.012 46.00 1669.25
Basement Infiltration @ 10 deg3024 0.010 10.00 302.40
29908.69
Total Allowable Loss
Difference---: -3569.20
� * '
- Room By Room Breakdown 960 Split with Gp''`ye >>>>��>>>>>>
>- )>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> >'>> ) >>>>>>>>>>
Living Floor 17 3' 30 � 80 186 149
^4(! 0ininFloor 0 3. 30 0
Room Ceiling 360 0. 22 79 Room Ceiling
Wall 304 3. 30 1003 Wall 144 3. 30 475
Window 51 34. 32 1750 Window 0 38. 28 0
Infil 2880 0. 79 2275 Infl 640 0. 79 506
Ent Dr 20 4. 62 92 SGD 33 38. 28 1263
Total------> 5240 Total -> 2393
Kitchn Floor 0 3. 30 0 Family Flour 0 3. 30 0
Ceiling 100 1 . 86 186 Room Ceiling 0 1 . 86 0
Wall 80 3. 30 264 Wall 0 3. 30 0
Window 9 34. 32 309 Window 0 38. 28 0
SGD 0 38. 28 0 SGD 0 38. 28 0
Infil 800 0. 79 632 Infl 0 0. 79 0
Ent Dr 0 4. 62 0 Ent Dr. 0 4. 62 0
Total------> 1391 Total -> »
Master Floor 192 3. 30 634 Main Floor 0 3. 30 0
Bedrm Ceiling 192 1 . 86 357 Bath Ceiling 60 1 . 86 112
Wall 224 3. 30 739 Wall 40 3. 30 132
Window 18 34. 32 601 Window 0 38. 28 0
Infil 1536 0. 79 1213 lnfl 480 0. 79 379
Total------> 3544 Total > 623
'
Bedrm Floor 0 3. 30 0 Mstr Floor 0 3. 30 0
Two Ceiling 156 1 . 86 290 Bath Ceiling 0 1 . 86 0
Wall 200 3. 30 660 Wall 0 3. 30 0
Window 18 34. 32 601 Window 0 38. 28 0
Infil 1248 0. 79 986 1nfl 0 . 0. 79 • 0
. Total------> 2537 Total ^ � . 0
Bedrm Floor 0 3. 30 0 Util Floor 0 3.30 0
Three Ceiling 0 1 . 86 0 Rm Ceiling 0 1 . 86 0
Wall 0 3. 30 0 Wall 0 3. 30 0
Wipdow 0 34. 32 0 Hi "dnw 0 38. 28 0
Infil 0 0. 79 0 1nfl 0 0. 79 0
Total------> 0 Total > 0
8smt Floor 756 2. 60 1966 Baseboard Heat ( if desired)
Con Ni 384 0. 62 3310 Livino Room. . . Watts 1535
Frmd Wl 624 2. 30 1435 Kitchon Watts 408
Window 51 23. 92 1220 Dining RoomWatts 701
SDG 0 26. 68 0 Family RoomWatts 0
Ent Dr 18 3. 22 58 Master Bedroom Watts 1038
Infil 6048 0. 32 1935 Bedroom 02Watts 743
Total > 9924 Bedroom 03. . . . Watts 0
Main Bath Watts 182
Mstr Bath Watts 0
' Utility Watts 0
Basement Watts 2908
Total > 7516 .
.
.
1.35
41e3 1l// 0
55' rl<d /0-.0
DPAi,.neop
Co um/ P,u/'i''4eMea
1XEU
d eck
H'
/00
6A.7Ayr.
pi) //3.0 36/
2g'
19'
10'
cµ/O 5u n1 ASF
11g1l.1 Floos EIc1/ l/7, 6 -
pm
Fid 1R, 0"
0/a8,0 22'
'00
eoNc 5(CPt
Co NG lJALI
S9'
/Gas -
93 Add
/00 0
DEAN GREER
N. 9609 SEMINOLE
SPOKANE, WA 99208
//O
Coax. PLit
/0 ce
Cp/Jh APt&t)
Fa /13.0
2
F,N ///.O
/35-1
0VC4ux/
Annie -
107. w de.
109,
09.5'
-5/09,0
a1.7./i da ectdwoL Parck_04oin,J •