1982, 02-22 Spokane Co Letter to Richards 4 SPOKANE COUNTY 1 DEPARTMENT OF BUILDING & SAFETY BUILDING - PLUMBING - MECHANICAL - FIRE 811 N. JEFFERSON SPOKANE , WA. 99260-0050 TELEPHONE : 456-3675 SPOKANE COUNTY _ �" "�y JAMES L. MANSON, DIRECTOR (2) February 22, 1982 Mr. Chuck Richards .6153 CRC Designers E. 300 Third Avenue Spokane, WA 99202 Re: Proposed Office and Bakery Addition Located at E. 594-9- Broadway, Spokane, Washington Op Dear Mr. Richards : The Spokane County Department of Building and Safety has completed a plan review of your submitted plans for the above mentioned project. Please contact the Spokane County Planning Department, Spokane County Engineering Department and the Spokane County Health Department for their findings and requirements. Listed below are several items that need correction before final approval can be granted by this department. 1. Any room having an occupant load of more than fifty (50) where fixed seats are not installed, and which is used for classroom, assembly or similar purpose, shall have the capacity of the room posted in a conspicuous place, near the main exit from the room as required by U.B.C. Section 3301(j) . oFt * ( c.effer- 2. The two (2) exit stairwalls for the second floor shall be placed a distance apart equal to not less than one-half of the length of the maximum overall diagonal . U.B.C. Section 3302(c) . Z . e,- 3. Safety Jim A.a^-r'n PA owctiri,�eY�e boy, y glass required where glass is eighteen (18) inches or less from floor or walking surface. U.B.C. Section 5406. occ (+ 3 tom- '1,h 111%sok 4. Please complete the door schedule showing door dimensions and typef3o`' hardware on doors 102 & 107. U.B.C. Section 3303. O K at 5. Please specify the run of the stairs. U.B.C. Section 3305(c) • toi, il� p�"" 6. At least one (1) handrail shall extend not less than eigh een(18) inches beyond the top and bottom risers and ends shall return or shall ter- minate in newel posts or safety terminals. Section 3305(i ) of the Regulations for Barrier-Free Facilities. 44 - , 4),l rlihr-I^ iesS ',14K 30 cupgn cy per Wily-, xeAyrs ayw 'tea eltveir- h.e\a l s `` sf)/ 6 X hi24- Page 2. Mr. Chuck Richards February 22, 1982 dip Nosing must be flush , non-slip and rounded to a radius of 1/2 inch maximum and open risers are prohibited. Section 3305 of the Regulation for Barrier-Free Facilities . I k 16e1 ia cher 30 , coe sers shun �ta5e . �jo h serer 8. Please verify that the main stairway width is three (3) feet wide and the landing is three (3) feet by three (3) feet minimum. U.B.C. Sec- tion 3305(g) . 0k., 4-2? Ly 9. Please note the slope of the proposed ramp for the front entrance. Section 3306 of the Regulations for Barrier-Free Facilities. Ramps having a slope exceeding one (1) vertical to twenty (20) horizontal shall have handrails as required by U.B.C. Section 3305. 10. Exits shall be illuminated at any time the building is occupied with light having an intensity of not less than one footcandle at floor level . At every required exit doorway and wherever otherwise required to clearly indicate the direction of egress , an exit sign with letters having a prinicipal stroke not less than 3/4 inch wide and at least six (6) inches high shall be provided from all areas. U.B.C. Section 3312(b) . 9tck 4a check 11. Where there is enclosed, usable space under stairs , the walls and soffits of the enclosed space shall be protected on the enclosed side as required for one-hour fire-resistive construction. U.B.C. Section 3305(m) . g- # /I Le+fer` 12. The exit stairs 107 exits through service/storeroom which is labeled as storage of trash cans. The required exit from the second level is not to pass through such area, unless it is separated by a one-hour rated wall and door assembly. Please submit details of enclosure. U.B.C. Section 3304(e) 444. kA 13. In Group "A", Division 3 Occupancies , having an occupant load of more than fifty (50) , exit doors shall not be provided with a latch or lock unless it is panic hardware. U.B.C. Section 3316(a) 64_ 14. The mechanical ventilation system shall meet the minimum requirements of U.B.C. Section 605. soci C. 1J. All water closet rooms shall be provided with a mechanically operated exhaust system, which is connected to the light switch, capable of providing a complete ange of air every fifteen (15) minutes. U.B.C. Section 705. Ok 1 JS Le-44-0,- 63) Please submit truss diagrams from the tr s manufacturer for review. :fferzfl5,42,1 SHS necJ DN0,31nIS6 17. The lavatory, urinal and water closet heig t and location shall meet the minimum requirements of Section 1711. The mirror, towel and other dis- pensers shall not exceed forty (40) inches above the finished floor. Section 1711 of the Regulations for Barrier-Free Facilities. ok -- (7 Je- ,— Page 3. Mr. Chuck Richards February 22, 1982 18. Drinking fountain to meet the minimum code of Section 1712. 04, 14- /a te5., 19. In wood frame floor construction where suspended ceilings occur, the space between the ceiling and the floor above shall be divided into areas not ex- ceeding 1,000 square feet. U.B.C. Section 2517(f) 2. OLc - 11 1_. 1-t-€r 20. In all stud walls and partitions , including furred spaces , fireblocking shall be placed so that the maximum dimension of any concealed space is not over ten ( 10) feet. Fireblocking shall be between studs along and in line with run of stairs adjoining stud walls and partitions . U.B.C. Section 2517(f) . ii Legr 21. Please supply a structual detail cross section of the new construction for review. 22) Please submit heat loss calculations for heated floor areas as required - by Washington State Energy Code, which requires R-13 in the walls , R-30 minimum in ceilings and R-5.40 under non-heated slabs (standard design) or an analysis procedure as specified by Section 503 <fd) )i.eed ceripu►-e, -}b ' C— QCG / 23. The minimum footing depth of 3' 0" below grade is requi -e. by Title 3 of Spokane County Ordinance 3.04.080. dk 44"2,3 `ti-er 24. Wood nailing shall be according to U.B.C. Table 25-P. 25. Drywall nailing shall be according to U.B.C. Table 47-G. o i( # 25- ye-111,- 26. Perimeter insulation shall be installed according to the minimum require- ments of Section 404(a) of the Washington State Energy Code.0lf 1-# 2,,b LQ-11-4.- 27. Attics with a vertical clear height of thirty (30) inches or more shall have an attic access opening not less than twenty-two (22) inches by thirty (30) inches . U.B.C. Section 3205(a) . 01,6 1k 27 14-(4.4, 28. Please specify that the proposed roof ventilation system meets the min- imum requirements of U.B.C. Section 3205(c) . Ow .y j_o• e h:4 - 29. The maximum flamespread classification of finished materials used on in- terior walls and ceiling shall not exceed that set forth in U.B.C. Table 42-B. U.B.C. Section 4204(a) . 02_ WZI Lem 30. Please indicate the wind, snow and floor loads as required. U.B.C. Chap- ter 23. N.0 30 C r- 31. The ducts shall be installed and insulated according to U.M.C. Chapter 10 and the Washington State Energy Code. --,e. Page 4. Mr. Chuck Richards February 22, 1982 32. Mechanical equipment which are installed on roofs shall meet the minimum requirements of U.M.C. Section 710.0k 32- 33. Z33. Each vent pipe or stack shall extend through its flashing and shall ter- minate vertically not less than six (6) inches above the roof nor less than one ( 1) foot from an vertical surface. U.P.C. Section 506. it 33 -o 34. Horizontal distance of trap arms shall meet the requirements of U.P.C. Table 7-1. Gyp_ .;*i_f /E''J [Tr 35. Guardrails shall be a minimum height of forty-two (42 inches as required by U.B.C. Section 1716. e 4-4r- Please verify and submit revised drawings or adden•.- or the above listed deficiencies . If you have any questions , please feel free to contact our department at 456-3675, between 8:00 a.m. and 5:00 p.m. , weekdays. Sincerely, Kenneth E. Jeffre Senior Plans Exam"u � Thomas Postlewait Plans Examiner gw Copy: Mr. Garry J. Padrta, E. 6422 Mallon, Spokane 99206 NOTE: For future reference, completion of the second level for office, will require an additional building permit. It should be so noted that two (2) complete separate exits from that level must be maintained. A baracade on either exit would be prohibited.