Loading...
2006, 03-13 Permit App: 06000681 RemodelProject Number 06000681 Inv: I Application Date: 3/13/2006 Page l of THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Proiect Information Permit Use: FINISH BASEMENT Contact: BURTON, DAN Address: 12907 E 10TH AVE C -S -Z: SPOKANE, WA 99216-0504 Setbacks: Front Lett: Right: Rear: Phone: (509)922-6078 Group Name: Site Information: Project Name: Plat Key: 002962 Name: WOODWARD PARK ADD District: F Parcel Number: 45223.0440 Block: 4 Lot 6 Site Address: 12907 E 10TH AVE Owner: Name: BURTON, DAN Address: 12907 E 10TH AVE Location:: CSV SPOKANE, WA 99216-0504 Zoning: UNKN Unknown Water District Hold: ❑ Area: 1,838.00 Acres Width: 0 Depth: 0 Right Of Way (h): 0 Nbr of Bldgs: 0 Nbr of Dwellings: 0 Review Information: Review Building Plan Review Released B� Originally Released: 3/7/2006 By: TMELBOU Landuse/Zoning/HE Conditions Released By: Must stay 5' from utility & drainage easement on rear lot line. Originally Released: 3/3/2006 By: Mharnois Sewer Review Released By: verified w/ spokane co utilities, on sewer since 1988. Originally Released: 3/7/2006 By: a_blake Permits: Operator: AMB Printed By: AMB Print Date: 3/13/2006 Project Number: 06000681 Inv: 1 Application Date: 3/13/2006 Page 2 of 2 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit -- — - --- Building Permit Contractor: OWNER Firm: OWNER Phone: (000) 000-0000 This Application: Total Project: Description Grin Type Notes Sq Ft Valuation So Ft Valuation BASEMENT R-3 VB finish 0 $1,300.00 0 $1,300.00 basement Totals: 0 $1,300.00 0 $1,300.00 Item Description Units Unit Des c Fee Amount RESIDENTIAL PERMIT FEE 1 SELECT $69.25 WSBCSURCHARGE 1 SELECT $4.50 SF PENS RV W < 7999 SQ FT 1 SELECT $27.70 Permit Total Fees: $101.45 Plumbing Permit Contractor: OWNER Firm: OWNER Phone: (000)000-0000 Item Description Units Unit Desc Fee Amount TOILETSBIDETS 1 NUMBER OF $6.00 SINKS 1 NUMBER OF $6.00 SHOWERS 1 NUMBEROF $6.00 FLOOR DRAINS 1 NUMBER OF $6.00 Permit Total Fees: $24.00 Notes: �. _ Payment Summary: _ Permit Two Fee Amount Invoice Amount Amount Paid Amount Ovine Building Permit $101.45 $101.45 $0.00 $101.45 Plumbing Permit $24.00 $24.00 $0.00 $24.00 $125.45 $125.45 $0.00 $125.45 Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: AMB Punted By: AMB Print Date: 3/13/2006 Project Number: 06000681 Inv:I Application Date: 03/07/2006 Pagel oft THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Project Information: Permit Use: FINISH BASEMENT Contact: BURTON, DAN Address: 12907 E 10TH AVE C -S -Z: SPOKANE, WA 99216-0504 Setbacks: Front Left: Right: Rear: Phone: (509)922-6078 Group Name: Site Information: Project Name Plat Key: 002962 Name: WOODWARD PARK ADD District: F Parcel Number: 45223.0440 Block: 4 Lot: 6 SiteAddress: 12907E 10TH AVE Owner. Name: BURTON, DAN Address: 12907E 10TH AVE Location:: CSV SPOKANE, WA 99216-0504 Zoning: UNKN Unknown Water District, Hold: ❑ Area: 1,838.00 Acres Width: 0 Depth: 0 Right Of Way (11): 0 Nbr of Bldgs: 0 Nbrof Dwellings: 0 Review Information: Review Y, f Building Plan Review eleasedB TLA Ii ® O(� r Landuse/Zoning/HE Conditions Released By: Sewer Review Released By: Permits:..a,..,.,.,-_sK,. - - Building Permit --- -- Contractor: OWNER Firm: OWNER Phone: (000)000-0000 Plumbing Permit Contractor: OWNER Firm: OWNER Phone: (000)000-0000 Operator: AMB Printed By: AB Print Date: 03/07/2006 Project Number: 06000681 Inv: 1 Application Date: 03/07/2006 Paget oft THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Notes: Payment Summary: Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and rinds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: AMB Printed By: AB Print Date: 03/07/2006 Permit Center Ave,$n t� In� nn 22 --\, PERMIT NUMBER SpoQkane SpoOkane Valle,eWA 10lb � � 11 V IS ^ PERMIT FEE: �s -�+1eY (509)666-0036 FAX: (jj09ss$$88-(�' O 1 CommunityDevelopment s*�nvs ]canesalle .o Il rrII �'nft�l� Residential Construction A 4eWd9t"'on ❑ Accessory Bldg Permit Application ❑ Addition/Remodel ❑ Deck t Other: Fio'WiNG l3ASKmk\ li SITE ADDRESS /;170% -. /01 - ASSESSORS PARCEL NO: s � 4' a33' �'` 'J LEGAL DESCRIPTION: Building ovpner DIMENSIONS: Name: "L)4OCk t C,1164r —E&,0- AA) Address: /ZQ07 E./07-4 City: &k4A1e zip: 10- !' Phon .5i9f ax: Contact Person:, xame: Phon $r0 V1j -� _Contractor Name: S6.4 % Address: City. Zip: Phone: Fax: Lic No: Exp. Date: City Bwmess Lie No: Describe the scope of work in detail: Cost of Project: I S /, -Tv **************The followtg MUST becomplete: write N/A if nota licable********************** HEIGHT TO PEAK: DIMENSIONS: # OF STORIES: TOTAL HABITABLE SPACE: MAIN FLOOR TO SQ. 2 FLOOR SQ. FTG: UNFIN BASEMENT SQ. FTG: IMPERVIOUS SURFACE FTG: AREA: FINISHED BASEMENT GARAGE SQ. FTG: DECK/COV. PATIO SQ. FTG: 30% SLOPES ON SQ. FTG: PROPERTY: # OF BEDROOMS: CONSTRUCTION TYPE: HEAT SOURCE: SEWER OR SEPTIC? The Pennine, verges, acknowledges and agrees by their signature that 1) If this permit is for construction of or on a dwelling, the dwelling ishvill be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or local laws, codes or ordinances. 6) Plans or additional information may be required to be submitted, and subsequently approved before this application can be processed. Signature Date 03-!02-'01/ Method of Payment: (Faxed permit applications will only be accepted with major bankcarcO ❑ Cash ❑ Check ❑ Mastercard ❑ NSA ❑ Other Bankcard#: Expires: VIN#: Authorized Signature: nr_vrsaD W&TM Spokane ,;OOValley 11707 E Sprague Ave Suite 106 ♦ Spokane VaRey WA 99206 509.921.1000 ♦ Fax: 509.921.1008 ♦ cityhall@spokanev Uey.org Residential Plan Submittal Minimums ❑ Completed Building & Mechanical application with: Accurate address, Parcel Number and/or Legal Description, description of work, owner and contractor information, signature, and date. ❑ Two sets of plans including Site Plan, elevations, floor plans, foundation plans With details, roof plan, framing plans & details. ❑ Show the height of any proposed buildings or accessory structures. ❑ Floor plan for each floor. Dimension to scale (minimum 1/8") and label each Room (including sq. footage of house and garage on plans) Show each level of existing house and square footage of any additions. ❑ All braced wall panel types: show locations and details of installation, including engineered design. ❑ Egress windows: Provide at least one window or exterior door approved for Emergency escape or rescue from a basement and in every room for sleeping. ❑ Smoke detector locations ❑ 22" X 30" attic access location ❑ 18" X 24" crawl space access: ❑ One-hour separation detail: between house and garage ❑ Floor framing details: Joist type, size, spacing and installation details ❑ Roof framing plan and details ❑ Furnace and hot water heater location. ❑ All header locations: type, size, and connections ❑ Foundation plan ❑ Insulation information SFoRgpe� 11707 E Sp,uc Avc, Suite 1D5 PERMITNUMBER f Name J16.4 Spokane Valley, WA 99206 9Z -/o Fax L' C�ityD,.Iopercnt�smkancvallev (509)688-0036 FAX: (509)686-0037 X PERMITFEE: Name: ore com Plumbing Permit Application ❑ Commercial ❑ Residential Ad&=: rity: S=ADDRrSS: U. No: Cityfiusm=ljc BuBd�O owveT DESDRIPTION OF WORK Name J16.4 . .UY Pb. 9Z -/o Fax Ad&—: St Zip: 'Contradoi. X _ Name: Phone: - Fax: Ad&=: rity: SL4: U. No: Cityfiusm=ljc No: Name: /' Fhwe: --6t)79 AUTHOR= SIGNATURE: a �aw1 DESDRIPTION OF WORK F OF UNITS % COST TOTAL AMOUNT 1 TgLET WATER CLOSET BIDETS X $6 .00 - 2 LG:S; X SSW - 3 TU65 X S&M 4 SHOWERS ER TRAP BATH. STALL, ONSITE BULT X S&M IAVSIBASINS. BAR MOOR, KITCHEN, 5 SINKS LAUNDRY, LTTIJ . JANnOM PHOTO, X WOO = X-RAY FOOD, PREPC NARY MEAT 5 DISHWASHER % SSW 7 CLOTHES WASHER X MOD - S GARBAGE DISPOSAL X $&DO S WATER SOFTENER X 56.00 10 ELECTRIC HOT WATER TANK NOTE IF GAS, SEE MECHANX:AL X 56.DD 11 FLOOR DRAINS CASE COIL TRJENM CONDENSATE X S&M ROOF DRAMSKNERFl.OW 12 DRAINS X 'S. 13 FOUNTAINS DRINKING % 5s vo WATER PPWGd)RAINJN WASTE, NSTALLATION, ALTERATION, REPAIR 14 VENT, PLUMBING REVERSAL REVERSALS 15 SEWAGE EJECTOR GRIND SL161P PUMP X SSW - ICE AN*R COFFEE MAKER HOSE BIB, 16 WATER USING DEVICE STEAMER X 56. DO PROOFEM CARBONAT SWAMP COOLER VACUUM BREAKER CHECK VALVE, 17 CROSS CONNECTION DEVICE AND RP. B.P.D. FOR VATS TANKS. BOILERS X SSW GREASE TRAP, SAND TRAP, 18 INTERCEPTORS CHEMICAL HOLDING TANK X 56.00 - 16 MEDICAL GAS outlet NITROUS, OXYGEN X 56.00 - NSCELLJJEOUS PLUI.IBING M FIXTURE X 56.00 21 PRIVATE SEWAGE DISPOSALSYS X sm.DO INID STR WASTE 22 INTERCEPTOR X 315.00 METHOD OF PAYMENT: SUBTOTAL ❑ CASH ❑CHECK ❑VISA ❑ MASTERCARD PROCESSING FEE S36.00 Cam EXPIRES: TOTAL PERMR FEE DUE: AUTHOR= SIGNATURE: a �aw1 .SpOm1tHR0` 11707 a spmpc Ave, Suite 106 jVA1ey Spok e Valley, WA 99206 PERMITNUNMER (509)668-0036 FAX: (509)666-003] Comnuniry Dcvelop.t aooAann•allcv or m PERMITFEE: Mechanical Permit Application ❑ Commercial ❑ Residential SITE ADDRESS: Buil&h owner Name: Phone: F.: Add.v City: state: Zip: Nvrc: Phone: Fu Add=: Citr. state: Zi': License Na: City Busman License No: Coot'act -� ' .. - .. ..:.-. N. Phone:.. AUTHORIZED SIGNATURE: uvrsEosasos FLOORS (continued) 90 2003 INTERNATI0NAL RESIDENTIAL CODE FLOORS TABLE R502.5(i)h-continued GIRDER SPANS' AND HEADER SPANS' FOR E%TERIOR BEARING WALLS - (Maximum spans for Douglas fir -larch, hem -fir, southern pine and spruce-plue-fir° and requlred number of Jack studs) GIRDERS AND HEADERS SUPPORtING SIZE GROUND SNOW LOAD pep' 30 Building wlah'(leet) 20 28 36 20 20 36 Span NJa Span NJ° SPan NJ ° Span NJ" Span NJ° 2-2.4 2-1 1 18 1 16 2 2-0 1 Is 1 1-5 2 2dx6 31 2 28 2 24 2 3-0 2 2-7 2 2-3 2 2-2x8 3-10 2 3-4 3 3 0 3 3 10 2 3A 2 2-11 3 22x10 4-9 2 4-1 3 3-8 3 4-8 2 0.0 3 3-7 3 2-2x12 5-6 3 4-9 3 4-3 3 5 5 3 4-8 3 4-2 3 mail, admg and woclear spite 3-2x8 C10 2 1 4-2 2 3-9 2 49 2 4-1 2 3-8 2 near 3-2x10 5-I1 2 SI 2 4 9 3 5-10 2 50 2 4-5 3 3-2x12 6to 2 5.I1 3 5< 3 6-92 S-10 3 S3 3 48 3 5-7 2 4-10 2 44 2 'a 2 49 2 43 2 4310 610 2 511 2 5 3 2 6-9 2 SIO 2 5 2 2 42x12 7-11 2 610 2 62 3 7 9 2 69 2 60 3 For Sl: 1 inch = 25.4 mm, 1 pound per square foe = 0.0479 LN/mt. a. Spans are given in feet and inches. or Tabulated values assume #2 grade lumber. e Building width is measured perpwdicular to the ridge- For widths between those shown, spans are permined to be ivarpolsa d. d NJ - Number ofj.k scads required to support tach end. Where the number of,e,u.cd jack studs equals one, the header is permitted to he s.pparted by an ap- proved framing anchor ansched in the fullheightwall stud and to the header e. Use 30 psf ground snow load for cases in which ground saw load is less than 30 psf and the roof live load is equal to or less than 20 psf. 2003 INTERNATIONAL RESIDENTIAL CODO 91 /y' Af of 5'. ANp -lujEWw.IR cld3,, '•� J /� C STu�gctC l'f.V1 -7 vu� bouf Wd. WiLL S" Z CIODER EWCk MALL �. SFS cm w� ZN-rs o rJ rJtu, JSP 11,117, fYe55 W;fJo+,) EtCu J To Cod bJAW-S FRAMED WtTk 3��L Full 2�tq„ '6 IN no2 WAILS CN CIntDQ( -;LOCK WAS 1:!'RMed w%TK 1'4 x1'1L or 2xz -Y NEW -rN-fDK W911,3 O?AMFD WlYN 'Gull Z)t4" OjJ b 9KHin S ,. 6W11"C/ any .V"fFh , ;rti Paned f IVW 5oMp Wa< f= Uti�X ��r�� �l4 w�T ' p�pfs eau vPrf� � Seer, T)JOh ?OCw— W��F — .�L��E J Al 'aT�'t_ C 6{ryLT 'off 44F"k.D� S� N T)JOh ?OCw— W��F — .�L��E J Al 'aT�'t_ C 6{ryLT 'off 44F"k.D� S� J4') 3C Al vl� _ UNP,TM(' 1� 6yny •a.e ",h 8B �_ 5" aadeR Nbelo z'�' bw cinder. Btecr vJAi. 5 , I �h 511-4;u i y 'Pose:' SlNgle �ive5 RepeeSerif pooeFr. FooNo�rienl oruea `+Nati usrcd A Double v -)O -P noqr WmPfr '$ Dr, er LOW; roe plon•LiA 0: u Stares snip zoom 5i,;kS AS o - TW rub, A45o NWKFD Sump pump 4o Sewer 4o � P PROVIDE DIAGRAMS AND ENGINEERING LAYOUTS FOR ROOF TRUSSES, BEAMS AND FLOOR SYSTEMS PRIOR TO FRAMING INSPECTIONS THIS BUILDING SUBJECT TO FIELD INSPECTION CORRECTIONS CITY COPY EMERGENCY EGRESS REOUIREMENTS ' FROM SLEEPING ROOMS 1) NET CLEAR OPENING 57 SQUARE FEET GRADE FLOOR OPENING (MAX 44') 5 D SQUARE FEET 2) NET CLEAR OPENING HEIGHT 241NCHES 3) NET CLEAR OPENING MOTH 2OINCHES 4) MAX FINISHED SILL HEIGHT 44•ABOVEFLOOR 5) EMERGENCY ESCAPE 8 RESCUE OPENING SHALL BE OPERATIONAL FROM THE INSIDE OF THE ROOM WITHOUI DIF USF OF 11 VS OR TOOLS WHEN INTERIOR ALTERATIONS. REPAIRS OR ADDITIONS REOUIRING A PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE ADDED OR CREATED IN EXISTING DWELLINGS, THE DWELLING UNIT SHALL BE PROVIDED WITH SMOKE ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGS. SMOKE ALARMS SMALL BE INTERCON- NECTED AND HARD WIRED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ALL ALARMS (BEDROOMS, ACTIVATEAREAS APPROACH NG BEDROOMS. VAULTED CEILING WITH RISE OF 24' 8 ON EACH FLOOR) AV EXHAUST FANS VISION 1001CFM kitchen TW 50 CFM bathrooms & laundry V�IT� To ��CTSt-Lo/L� Egress windows openable 5.7 sq. ft. - 44" sill STAIRWAYS: Minimum width 36 in. with min. tread run of 10 in., max. rise of 7'/4 in. & nosing of3/4-1 V. in. Min. 6 ft. 8 in. headroom. Enclosed usable space under stairways requires 1 hour fire protection of V. in. GWB UPC 508.2 - Water heaters require anclionng or strapping at upper and lower one third points to prevent horizontal displacement during earthquakes. Strapping shall be a minimum of 4 inches above controls. FACTORY -BUILT FIREPLACES: Combustion Air Required Hearth Clearances per Manufacturer's Instructions Tight Fitting Doors Required REVIEWED FOR CODE COMPLIANCE SPOKANE VALLEY "R. IMG DIVISION TAS Technical Assistance Services Garden Coon Building, 222 W. Minion Avenue. Suite 224, Spoken% WA 99201 (509) 325-4476 FAX (509) 325-4587 08/03/06 City of Spokane Valley Building Department 11707 E. Sprague Ave. #106 Spokane Valley, Wa. Project: Single Family Residence/ Basement Remodel Total Area: 2824 sq.ft. (1412 sq.ft. Basement/ 1412 Main) Address: Bertrand Residence 12907 E. 10th Spokane Valley, Wa. Contractor/Phone: Heating Type: Gas Glazing Area: 290.7 sq.ft. main floor/ 39.3 sgTL basement (23.3 sq.ft. replaced existing/ 16 sq.ft. new) Glazing Percentage: 11.7% total for the house (basement and main floor)/ 2.8% for the basement area. PROJECT COMPLIES with TABLE 5-1/ TARGET COMPONENT VALUES FOR GROUP R OCCUPANCY, 2004 Washington State Energy Code. NOTE: Since the percentage of glazing for the total residence is less Nan 15%a the balance of the 15% allowable glazing can be used for calculating Chapter 5 allowable heat loss of the basement. This glazing area (93.6 sq.ft.) is 6.6% of the basement area. Existing metal frame basement windows have been replaced with vinyl frame w/ low -E glazing for a heat loss UA savings of 24.4 Btu/h. ALLOWABLE HEAT LOSS (Btu/h/deg.F) Glazing: 6.6% 1412 sq.ft. basement) = 93.6 sq.ft. @ U .40 = 37.4 BG Walls (8' depth): 1261 gross sq.ft./ 1167.4 net sq.ft. R19 @ U .037 = 43.2 159 Lf. BG slab @.57 F -value = 90.6 TOTAL UA ALLOWABLE = 171.2 12907 E. 10th PROPOSED HEAT LOSS (BtWWdeg.F) Glazing (2.8% basement): 39.3 sq.ft.vinyl w/ low -E @ U.35* = 13.8 BG Walls (8' depth) : 1221.7 sq.ft. RI @ U .054 = 66.0 159 Lf BG slab @.56 F -value — 89.0 ' NFRC values TOTAL PROPOSED HEAT LOSS — 168.8 168.8 Bluth < 171.2 Btu/h — Project complies w/ Table 5.1 Edward R. Fields Technical Assistance Services