Loading...
1991, 05-20 County Comments re: Additions & Remodel 4 I it S p O K A N E _iif Jt3 ;3-9hi� '-4&• 11 •a § Nw, C Co U N -r Y DEPARTMENT OF BUILDINGS • A DIVISION OF THE PUBLIC WORKS DEPARTMENT JAMES L.MANSON,C.B.O.,DIRECTOR DENNIS M.SCOTT,P.E.,DIRECTOR May 20, 1991 Post-ItTM brand fax transmittal memo 7671 Steve Piscitello �5=�I• �'"'' � - � NORTHWEST ARCHITECTURAL COMPANY Dept. i.� - West 1203 Riverside Avenue i � �aadl i. Spokane, Washington 99201 I Re: Additions and remodel to Valley General Hospital Located at East 12006 Mission Avenue Dear Mr. Piscitello: BARRIER-FREE REQUIREMENTS Washington State Regulations for Barrier-Free Facilities 1. A space in the accessible route of travel, extending a minimum of eighteen (18) inches beyond and to the side of the strike jamb, shall be provided at -all doors. (Section 402 of the Regulations for Barrier-Free Facilities) . Doors numbered 107A, 109B, 114, 119, 152 A & B. 2. Where the door is equipped with both closer and latch, at least 12 inches shall be provided beyond the strike jamb on the non swing side. (Section 402 of the Regulations for Barrier-Free Facilities) Doors numbered 121. 3 . The landing at the entry to room 172 must meet Section 3304 UBC. CONSTRUCTION COMMENTS 1. This department has some concerns about the location of the fuel ... storage tank. The alcove poses a unique problem with both fire fighting access, venting of fuel vapors from tank and re-fueling operations. The tank venting should be piped to a location above roof lines. The tank must be a rated tank approved for above ground locations i.e. explosion venting etc. The tank must be provided with secondary containment. A separate permit is required for tank installation. Security and signage must be provided. Note: Both tanks must meet these requirements. CODE ENFORCEMENT DIVISION WEST 1303 BROADWAY•SPOKANE,WASHINGTON 99260-0550•(509)456-3675 FAX(509)456-4703 411 S 2. High-pressure medical gas supply cylinder shall be enclosed in a separate room or enclosure of not less than one-hour fire-resistive construction. Every door opening into such enclosures shall be protected by tight-fitting smoke and draft control door assembly having a fire-protection rating of not less than 20 minutes. The door and frame shall bear an approved label or other identification showing the rating thereof. Door shall be maintained self-closing. (UFC Section 74.204) . 3. In addition to the inspections required by Section 305, the owner shall employ a special inspector during construction on the following types of work: 1. Concrete with a design strength of over 2,500 p.s. i. 2 . Structural welding: including welding of reinforcing steel. Please indicate the name of the testing laboratory prior to the release of the permit. Please submit copies of the reports to the Division of Buildings for review. (UBC Section 306) (Please submit special inspector forms) Please Note: A suitable location on site will be required for posting special inspection activities and "Approved plans, shop drawings, specification" contractor and sub-contractors should contact this department for permits pre-inspection prior to commencing work. i.e. structural, plumbing, mechanical. 4. Approved fabricator is required for all structural steel work or special inspections are required Section 304 14 (g) . 5. All wood to be used in the Type I F.R. portions of this structure, i.e. wood backing nailers etc. must be fire retardant treated "No exception". 6. Please provide design submittals which substantiates the required fire-resistive requirements for all building elements. The Type V-1 hour portion (outpatient and SAC Department) requires one hour ceiling. The Type I-F.R. portion requires three hour structural frame. Two hour ceiling/roof, and exterior walls meeting Section 1803 . Submittals shall include test data, research reports. and/or other data to justify required ratings. 7. Please provide MSDS sheets for chemicals submitted on hazardous material worksheets. A plan for method of storage and storage should be identified. A clean-up plan in the event of spillage should be developed and posted. 111 8. The fire alarms system must be extended into all new portions of the structure. Please provide details. 9. Please provide details of exit signage. Only details appear to show on demolition plans. ENERGY COMMENTS Washington State Energy Code 1. The building shall comply with the energy code requirement as specified in the Washington State Energy Code (WSEC) if gas heated, or the Northwest Energy Code (NWEC) if electrically heated. Please submit heat loss calculations for the proposed building which meet the minimum requirements of the Washington State Energy Code. (-10 F) . 2. Provide lighting lay-out, switches and controls including light fixture schedule showing the specifications and wattage. Also provide lighting budget calculations for interior and exterior portions of the building, including parking area, per Section 505 and Table 5-11 of the NWEC. Lighting budget calculation form is attached. MECHANICAL AND PLUMBING COMMENTS Mechanical (See item #4 under Construction Comments) 1. Fire dampers shall be located and installed per UMC and UBC. (UMC Section 1006) Both areas of construction are fire rated and required fire dampering of all penetrations. 2. Supports for condensing units shall be designed to safely carry the equipment. Supports from the building or parts of buildings that are of non-combustible construction shall be non-combustible. 3 . Supports for ducts on roof, Sheet M-4.4 and detailed on Sheet A-4. 1 detail 8 will require documentation to verify that brackets and pre-cast units are adequate to resist wind loads. Will pre-cast units have an impact of settling into the existing roofing system? Plumbing 1. The construction type of the building is a Type I F.R. ABS and PVC DWV piping- installations shall be limited to those structures where combustible construction is allowed i.e. condensate drains mechanical notes. ii0 2. Cross-connection control shall be provided for potable water as per UPC Chapter 10. FIRE PROTECTION COMMENTS 1. Portable fire extinguishers shall be installed according to UFC Standard No. 10-i. 2 . When serving 100 or more sprinklers, automatic sprinkler system shall be supervised by an approved central, proprietary or remote station service or a local alarm which will give an audible signal at a constantly attended location. (UBC Section 3803) . (New zones must be provided in annunciator panel) 3. Provide shop drawings for all relocation and new areas prior to installation of system. Please verify and submit revised plans for the above listed items. Should you have any questions, please contact this office between the hours of 8: 00 a.m. and 4:00 p.m. , weekdays. Sin• -�ly, 4111 rIL,/ enneth ;0r - - rey Special Projects Administrator KEJ:rmd