1997, 07-22 Permit App: 97005357 Shop Addition PROJECT NUMBER= 97005357 APPLICATION DATE= 07/22/97 PAGE= 01 PROJECT NUMBER= 97005357 APPLICATION DATE= 07/22/97 PAGE= 01 ****** THIS I3 NOT `A PERMIT ****** PENALTIES WILL BE ASSESSED FOR COMMENCING WORK WITHOUT A PERMIT SITE STREET= 10518 E 13TH AVE PARCEL#= 45204.2206 ADDRESS= SPOKANE WA 99206 PERMIT USE= SHOP ADDITION (16 X 20/UNHEATED) PLAT#= 002704 PLAT NAME= UNIVERSITY PLACE BLOCK= 21 LOT= ZONE= UR-3.5 DIST#= F AREA= 00000000 F/A= F WIDTH= 100 DEPTH= 142 R/W= # OF BLDGS= 2 # DWELLINGS= 1 WATER DIST = OWNER= WAIDE, MARGE PHONE= STREET= 10518 E 13TH AVE ADDRESS= SPOKANE WA 99206 CONTACT NAME= LONNIE GOOLIE PHONE NUMBER= 509 468 8000 BUILDING SETBACKS: FRONT= NA LEFT= 44 . 9 RIGHT= NA REAR= 37 . 6 ****************************** REVIEW INFORMATION ***************************** DEPARTMENT REVIEW REQUIREMENT BUILDING PLAN REVIEW REQUIRED APPROVAL: J SHATTO DATE: 07/22/97 BUILDING SETBACK REVIEW REQUIRED APPROVAL: J SHATTO DATE: 07/22/97 ******************************* BUILDING PERMIT ******************************* CONTRACTOR= GOOLIE CONSTRUCTION PHONE= 509 993 7878 STREET= 2118 E LINCOLN RD ADDRESS= SPOKANE WA 99207 NEW= REMODEL= ADDITION= X CHANGE OF USE= DWELL UNITS= OCCUP. LD= BLDG HGT= 12 STORIES= 1 BLDG W X D = 16 X 20 SQ FT= 320 SPRINKLER= N REQ PARKING= #HANDICAP= CRITICAL MAT= N DESCRIPTION GROUP TYPE SQ FT VALUATION SHOP U-1 VN 320 3840.00 ITEM DESCRIPTION QUANTITY FEE AMOUNT RESIDENTIAL VALUATION Y 88. 00 RESIDENTIAL SURCHARGE Y 19.36 STATE SURCHARGE Y 4.50 PROJECT NUMBER= 97005357 APPLICATION" DATE= 07/22/97 PAGE= 02 PERMIT TYPE FEE AMOUNT AMOUNT 'PAID AMOUNT OWING BUILDING PERMIT 111. 86 .00 111. 86 111. 86 .00 111. 86 PROCESSED BY: JULIE SHATTO PRINTED BY: JULIE SHATTO ******************************** THANK YOU ************************************ 6 1) ALL W06KHAMSHIP AND MATERIALS SHALL COMPLY IN ALL RESPECTS WITH ALL CODES AND 'REGULATIONS HAVING JURISDICTION AT THE SITE. -2)* PLAN DIMENSIONS TAKE PRECEDENCE OVER SCALE SHOWN. 7 3) CONTRACTORS SHALL VERIFY LOCATION OF ALL UTILITIES, PROPERTY LINES'AND BUILDING SETBACKS, AND SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE JOE SITE. 4) ALL MATERIALS SHALL BE OF NEW GRADE SPECIFIEDANDBE GUARANTEED AGAINST INHERENT AND/OR DEVELOPED DEFECTS OCCURRING WITHIN ONE YEAR OF CERTIFIED COMPLETION. - 5) ALL FOOTINGS SHALL BE CARRIED TO UNDISTURBED SOIL AND/OR PES 'DETAIL. 6) CONCRETE MIX SHALL BE MINIMUM 1:3:4: WITH MAXIMUM 7 1/2 GALS WATER PER ONE SACK BATCH OR MINIMUM 2500 PSI AT 28 DAYS... 7) REINFORCING STEEL MESH SHALL CONFORM TO U.E.C. 26-6, 27-7AND ASTM AS2.34 AS LAST AMENDED. 8) REINFORCING STEEL BARS SHALL CONFORM TO U.E.C. 26-4, 26-5, 26-6 AND ASTM NEW BILLET STEEL A15-50 AND A-305 AS LAST AMENDED. S) ALL WOOD MENDERS IN CONTACT WITH CONCRETE SHALL BE FOUHDATON GRADE REDWOOD OR PRESSyRE TREATED DOUGLAS FIR. EMBED 1/2' ROUND X 10' MB.. 12' EACH WAY FROM ALL ENDS AND MAXIMUM 6' O.C. 7' INTO SLAB FOR ALL BEARING AND EXTERIOR WALLS. INSTALL 1/2 X 3' RAMSET NAILS AT 3' O.C. THROUGH BOTTOM PLATES FOR ALL INTERIOR NONBEARING WALLS. 10) ALL HORI70NTAL FRAMING LUMBER SHALL BE CONSDTRUCTION )1:?.1 J&P 1500 F GRADE D.F. ALL VERTICAL SHALL BE STANDARD NO.2 J&P 1220 F GRADE UNLESS OTHERWISE NOTED. 11) INSTALL i EIGHT' X 1 1/2' WIDE METAL STRAP 'TIES EACH FACE OF WALL WHERE PLATES ARE INTERRUPTED OF BROKEN. 121 OPENING HEADERS SHALL BE 4' X 4' UNLESS OTHERWISE NOTED. 13) ALL POSTS SHALL BE SET ON CODE APPROVED 'U' STRAPS TO CONCRETE UNLESS OTHERWISE NOTED. 14) ROOF SHEATHING FOR PITCHED ROOFS 4:12 AND OVER SHALL BE 2' X 6', STANDARD GRADE D.F. 2-6d PER BEARING, FOR ROOFS UNDER 4:12 ROOF SHEATHING SHALL BE 1/2' EXT. TYPE C -C STRUCTURAL 2 GRADES D.F. PLYWOOD, NAIL 8d 6' O.C. AT JOINTS AND PERIMETER 12. O.C. AT INTERMEDIATE SUPPORTS. 15) ROOF INSULATION 'R' VALUE SHALL BE MINIMUM R.30. 16) PROVIDE 2' NOMINAL BACKING FIOR ALL CABINETS FIXTURES & ACCESSORIES. 17) ALL LUMBER TO BE GRADE MARKED PER U.E.C. 1585 2505. 18) ALL DRYWALL PLASTER AND STUCCO SHALL COMPLY WITH CHAPTER NO. 47. OF THE U.E.C. 191 ALL EXTERIOR HOSE BIBS SHALL HAVE UNREMOVABLE ANTI- SIPHON DEVICES. 20) -ELECTRICAL SYSTEM SHALL DE GROUNDED IN ACCORDANCE WITH CODE REGULATIONS - IN FOUNDATION AT SERVICE PPN2L LOCATION. ALUMINUM WIRE 02 AUG AND SMALLER SHALL NOT BE USED IN ELECTRICAL WIRING. 21) ALL FIXED APPLIANCES S'H'ALL BE ON ,ECP: -RATE CIRCUITS. _ � 1 GENERAL NOTE S PLOT PLA111 LEGAL DESCRIPTION LoT 1TNS `oUicj 1i-i� ['Lock' '21 1 �LACS 4 �O-' S.WY ilk .