2014, 06-27 Energy Compliance Cert Property Address: 13119 E 13th Spokane Valley, WA
Conditioned Floor Area: 1250 Date: 06 /27 / 2014
Builder or registered design professional:
Home Energy Audit Tech
Signature: /#1a eStown 509 280 0381
R-Values
Ceiling: Vaulted R- Floors: Over unconditioned space R- 30
Attic R- 49 Slab on grade floor R-
Walls: Above grade R- 21 Doors: Metal R- 5.6
Below.int. R- Glazed R- 3.3
Below,ext. R- R-
U-Factors and SHGC .33
br NFRC rating(or) Windows U- 41;) SHGC- N/A
err Default rating(Appendix A wsr:C 201 2) Skylights U- SHGC- N/A
Table 406.2 Option(s) <1500 3a Total 406.2 Credits .5
Heating,Cooling&Domestic Hot Water
•+ System Type Efficiency
Heating Gas forced air 95%
l
Electric central
DHw Gie -Electric 90 Gal ,93 FF
Duct&Building Air Leakage
ry
All ducts&EIV AC in conditioned space ( /no) Insulation R- 8
Air handler present (yes in)
Test Target 50 CFM(a;25Pa Test Result 39 CFM(d:25Pa
Building air leakage target:ACl1 0<5.0-Tested leakage:ACH50= 11.6-0
Onsite Renewable Energy Electric Power System
System type: Rated annual generation Kwh