Loading...
2006, 09-29 Permit App: 06003865 Finish Basement Project Number: 06003865 Inv: 1 Application Date: 9/29/2006 Page 1 of 2 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Project Information: u, ,un, a a n ce a.aaffi a ro a Permit Use: FINISH BASEMENT,FAMILY ROOM& Contact: GARREFFA,DOMINIC BEDROOM Address: 4906 E 14TH AVE C-S-Z: SPOKANE VALLEY,WA 99212 Setbacks:Front Left: Right: Rear: Phone: (509)448-3921 Group Name: Site Information: Project Name: Plat Key: Name: WOODLAND TERRACE ADD District: D Parcel Number: 35233.1508 Block: 15 Lot: SiteAddress: 4906 E 14TH AVE Owner:Name: GARREFFA,DOMINIC Address: 4906 E 14TH AVE Location::SPO SPOKANE VALLEY,WA 99212 Zoning: UR-3.5 Urban Residential 3.5 Water District: 107 SPOKANE,CITY OF Hold: ❑ Area: 6,775 Sq Ft Width: 54 Depth: 130 Right Of Way(ft): 60 Nbr of Bldgs: 1 Nbr of Dwellings: 1 Review Information: ... x ,uM_ _ern , . Review Building Plan Review Released By: Originally Released: 9/29/2006 By: TMELBOU Permits: : .= ten._ . Building Permit Contractor: OWNER Firm: OWNER Phone: (000)000-0000 This Application: Total Project: Description Grp Type Notes Sq Ft Valuation Sq Ft Valuation BASEMENT R R-3 VB FAM 0 $3,000.00 0 $3,000.00 ROOM/BDR OOM Totals: 0 $3,000.00 0 $3,000.00 Item Description Units Unit Desc Fee Amount RESIDENTIAL PERMIT FEE 1 SELECT $83.25 WSBC SURCHARGE 1 SELECT $4.50 SF PLNS RVW<7999 SQ FT 1 SELECT $33.30 Permit Total Fees: $121.05 Operator: AMB Printed By: AMB Print Date: 9/29/2006 Project Number: 06003865 Inv: 1 Application Date: 9/29/2006 Page 2 of 2 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Lots on the north side of 14th in the 4800 and 4900 block have fill. Soils investigation/foundation engineering done by Strata(see plat file)requires:(1)footings=min.24 inches wide(2)foundations no closer than 12 ft from north edge of fill Lots on the north side of 14th in the 4800 and 4900 block have fill. Soils investigation/foundation engineering done by Strata(see plat file)requires:(1)footings=min. 24 inches wide(2)foundations no closer than 12 ft from north edge of fill **DO NOT ISSUE BUILDING PERMITS FOR LTS 11 & 12 BLK 16,LTS 9-16 BLK 15,LTS 1 &2 BLK 27&LTS 1-8 BLK 28 UNTIL CC&R'S ARE ACCEPTED,SURETY IN PLACE FOR ALL IMPROVEMENTS OR FINAL CONST ACCEPT CERT&ANY DEDICATIONS OR EASEMENTS ARE RECORDED PER S RASKELL Payment Summary: t yaw:: . _: PI. =« -..= = kainananaal Permit Type Fee Amount Invoice Amount Amount Paid Amount Owing Building Permit $121.05 $121.05 $0.00 $121.05 $121.05 $121.05 $0.00 $121.05 Disclaimer: Submittal of this application certifies the owner(or person(s)authorized by the owner)has both examined and finds the information contained within to be true and correct,and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for,or an approval of,any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: AMB Printed By: AMB Print Date: 9/29/2006 Project Number: 06003865 Inv: 1 Application Date: 9/27/2006 Page 1 of 2 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Project Information: Permit Use: FINISH BASEMENT,FAMILY ROOM& Contact: GARREFFA,DOMINIC BEDROOM Address: 4906 E 14TH AVE C-S-Z: SPOKANE VALLEY,WA 99212 Setbacks:Front Left: Right: Rear: Phone: (509)448-3921 Group Name: Site Information: Project Name: ..._. Z.�e iarrw:;rm a aewua ,ca.a.�°u�-. �_ �:a vm. z „w., ,«:.! :-acar wrweww, ;.a .a•::_.. ,;_i Plat Key: Name: WOODLAND TERRACE ADD District: D Parcel Number: 35233.1508 Block: 15 Lot: SiteAddress: 4906 E 14TH AVE Owner:Name: GARREFFA,DOMINIC Address: 4906 E 14TH AVE Location::SPO SPOKANE VALLEY,WA 99212 Zoning: UR-3.5 Urban Residential 3.5 Water District: 107 SPOKANE,CITY OF Hold: ❑ Area: 6,775 Sq Ft Width: 54 Depth: 130 Right Of Way(ft): 60 Nbr of Bldgs: 1 Nbr of Dwellings: 1 Review Information: . .: = :- s Review Building Plan Review Released By: vt6 Permits: .„ _m — _&,. "' MNIMv. Building Permit Contractor: OWNER Firm: OWNER Phone: (000)000-0000 Operator: AMB Printed By: AMB Print Date: 9/27/2006 Sep 26 06 03: 26p Joaine Garreffa 509-448-3921 p. 1 4000.1\0.10Permit Center Spokane ""`" 11707E Sprague Ave,Suite 106 PERMIT NUMBER: 366,6--' �`�Vsi�Ie Spokane Valley,WA 99206 PERMIT FEE: 1 y (509)688-0036 FAX:(509)688-0037 _ Community Development www.spokanevallev.oro Residential Construction ❑New Construction ❑Accessory Bldg Permit Application Addition/Remodel [ Deck 5Other: SITE ADDRESS Mrygg ili' Av- ASSESSORS PARCEL NO: 32-3✓I Z3 LEGAL DESCRIPTION: RIPTION: yVOd (a.1,6 . .1, /VL . et 'Li v a 2-0f .+ Lo 4'.\5.'80 L0 1- 7 -51 N Z Ailey 4 Building Owner: Dow i n I L ear r 4,,,_ Contractor. Ad) Name: innr.1 L r..... 0,. ;(_,6,1/4.... 0.. D� Name: to Address: nib E l b � !tom- Address: City: tate: !\j A Zip: City: State: Zip: �5��lr,� S �t9Z(Z Phone:T-7yr " _,!t g_ Z' Fax:5 _ t I g-yni ` Phone: Fax: V_! t 't Contractor Lic No: Exp Date: Contact Person City Business Lic.No: Name: 1-70 14'1.1.A.c G 60 rrT_li� � Phone: 15 I-2 LL� j7Z - 9 P esc ibe the s ope of work in s etail: Cost of Project: $ e5}-`3D0 . 1211 i i. I A S I 'h i i #da A ' a! O. lii!244 ` t t I A_ a C. to I i t . 1 ! M.'. ■ ,4 LJ att. ii. i I.- t e I Pauli j **************The following MUS be complete: (write N/A if not app - :ble) ********* ********** Qaqut HEIGHT TO PEAK: DIMENSIONS: #OF STORIES: TOTAL HABITABLE SPACE: e5.floruktcd Z.S. /- 113N 2 es4-imcdtd r 1SWsf, MAIN FLOOR TO`SQ. 2""FLOOR SQ. FTG: UNFIN BASEMENT SQ. FTG: IMPERVIOUS SURFACE (rOtky frord7=13(1 /.4 i(Yl CA 5j�5-P. AREA: FINISHED BASEMENT GARAGE SQ. FTG: DECK/COV.PATIO SQ. FTG: 30%SLOPES ON +IA 1 SQ. FTG:4$4- ) 'esf 20 C5it 4 LWSF PROPERTY: l #OF BEDROOMS: CONSTRUCTION TYPE: HEAT SOURCE: SEWER OR SEPTIC? :.kAl,1e4..L' Eiu( favctd aur 5-nACJ1 The permitee verifies,acknowledges and agrees b eir signature that: 'I) If this permit is for construction of or on a dwelling,the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center, 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal,state or local laws,codes or ordinances.6) Plans or additional information ay be required to be submitted,and subsequently approved before this applicationcan be processed. Signature OCIUALL, Cnikid r Date qC nJ„ Method of Payment ❑ Cash X Check 0 Mastercard 0 VISA Bankcard#: Expires: VIN#: Authorized Signature: REVISED&2512005 SEP 26 2006 15:53 509 448 3921 PAGE.01 r WSEC TABLE 6-2 PRESCRIPTIVE REQUIREMENTS°'1 FOR GROUP R OCCUPANCY CLIMATE ZONE 2 g GlazingU-Factor 12 Wall? Wall? s Glazin OOH Vaulted Wall int° ext Slab Option AreatO: Factor GCeiling2 I;eiling3rade on Below Below Floors Grade of floor Vertical Overhead" Grade Grade 10% 0.40 0.58 0.20 R-38 R-30 R-21 R-21 R-12 R-30 R-10 int' 11. 15% 0.40 0.58 0.20 R-38 R-30 R-19+ R-21 R-12 R-30 R-10 R-58 111. 17% 0.37 0.58 0.20 R-38 R-30 R-19+ R-21 R-12 R-30 R-10 R-58 IV. 25% 0.35 0.58 0.20 R-38/ R-30/ R-21 R-15 R-12 R-301 R-10/ Gr • ._- ..' U=0.029 F=0.54 .-- R- ._------ - —� occupancy U=0.054 Only V. Unlimited 0.35 0.58 0.20 R-38 R-30 R-21 R-21 R-12 R-30 R-10 Group R-3 int' Occupancy Only V • nim e. I. •. - : --30/ `-21 R-15 R-12 R-30/ R-10/ Group R-1 U=0.031 U=0.034 int'/ U=0.029 F=0.54 Occupancy U=0.054 Only * Reference Case 0. Nominal R-values are for wood frame assemblies only or assemblies built in accordance with Section 601.1. 1. Minimum requirements for each option listed. For example,if a proposed design has a glazing ratio to the conditioned floor area of 13%,it shall comply with all of the requirements of the 15%glazing option(or higher). Proposed designs which cannot meet the specific requirements of a listed option above may calculate compliance by Chapters 4 or 5 of this Code. 2. Requirement applies to all ceilings except single rafter or joist vaulted ceilings. 3. Requirement applicable only to single rafter or joist vaulted ceilings. 4. Below grade walls shall be insulated either on the exterior to a minimum level of R-10,or on the interior to the same level as walls above grade. Exterior insulation installed on below grade walls shall be a water resistant material,manufactured for its intended use,and installed according to the manufacturer's specifications. See Section 602.2. 5. Floors over crawl spaces or exposed to ambient air conditions. 6. Required slab perimeter insulation shall be a water resistant material,manufactured for its intended use, and installed according to manufacturer's specifications. See Section 602.4. 7. Int. denotes standard framing 16 inches on center with headers insulated with a minimum of R-5 insulation. COOPERATIVE EXTENSION WSEC Builder's Field Guide 5th Edition WASHINGTON STATE UNIVERSITY 1-7 ENERGY PROGRAM AMEMMMEMINIMMEW- Sen 25 O6 09: 39p Joaine Garreffa 509-448-3921 p. 1 WINDOW WELL: loa 6e ct 6,� Min. 9 sq. ft. horizontal area. Virerfe Min. 3 ft. horizontal projection and width. 2IQti 1/77-h L.h AV-C Max. 44 in. vertical depth without a ladder NA- 011212 -KV---"Crami:u\ "iiiti 1-A-V. -61111 (501) iggc-t- Es n2 ruijA0, J,, q_ frSi- i's t 1 /1�(TI,J�I 1• �1 �ti .. t lA a (mit. r''' - f \} \i\h•nda�) _ YZ -firooce-ci Now +0 Cd° - j\-111* ._ - 1100_-- ZrS)�Zin P EMERGENCY gauss RIOU$REMENTB FROMgaussHOS ROOMS IRE {` Z� 1)NET CLEAR OPENING: 5.7 SQUARE FEET GRADE FLOOR OPENING(MAX 44•) 5.0 SQUARE FEET - 6 2)NET CLEAR OPENING HEIGHT 24 INCHES 5' g 3)NET CLEAR OPENING 1MDTM 44 ABOVE FLOOR 4)MAX FINISHED SILL HEIGHT . �� � SIEMERGENCYESCAPEi1lfSCUEOPENINGSHALLSE . ______i\---7 .- OPERATIONAL FROM TMEAISIOE OF THE ROAM WITHOUT THE USE OF$EVS OR TOOLS C �� U S 5 5 *wok kiti\ lia tii1C i *....e0,00.0-,,,,,or _ . +r,/,s .0, 'cl-,.---<._(( l ._�S AW, 4-\ ,v\cV\t5 I .___. ,�,.--r--� 1 SMOKE ALARMS SHALL BE INTERCON- / 1 NECTED AND HARD WIRED IN SUCH A i . 1 << MANNER THAT THE ACTIVATION OF ONE c ALARM WILL ACTIVATE ALL ALARMS. i i, ,1 REA PROAC { , (BEDROOMS, A ��� .P , ; BEDROOMS , VA`Ui:. •IEG CEILING WITH RISE Of $4" & O.N. FLOORl`I 801 ~3 31:4 C - iit EXHAUST PANS \ f .-\ 100 CFM kitchen \\ // 5() CFM bathrooms PROI`ECTION A D OPENINGS BE EEN ��.,r- DWELL!' •ND PRI ATE GARAGES •LL HAVE: in`j� V414-414 Ta WHEN fNTErouR ALTERATIONS,REPAIRS OR ADDITIONS 1)MATERIAL'''.TTIO. ON THE G RAGE SIDE.PROVED OR ONE HOUR FIRE •ESISTIVE REQUIRING A PERMIT OCCUR,OR WHEN ONE OR MORE CO 5/8"T •E"`YP BOAR )(HABITABLE SPACE ABOVE)OR SLEEPING ROOMS ARE ADDED OR CREATED IN EXISTING D 1/2"8GYP 8 D(BOAR NCE/ATTIC,FLOOR/CEILING) PWEI LINGS, THE DWELLING UNIT SHALL BE PROVIDED WITH SMOKE ALARMS LOCATED AS REQUIRED FOR NEW 2)OPENINGS B EEN GAG,GE AND RESIDENCE SHALL BE DWELLINGS. EQUIPPED WITH olLID WOO DOOR,SOLID OR HONEYCOMB CORE STEEL DOM ,' - ESS THAN 1 3/8",OR 20 MINUTE FIRE RATED DOORS. C qFP 25 2PG18 22 06 509 448 3921 PAGE.01 UPC 508.2— Water heaters require anchoring or strapping at upper and lower one third points to prevent horizontal displacement during earthquakes. Strapping shall be a minimum of 4 inches above controls. T040001 f', i,1(0449 Ar,)02.4 kir 40 irlia0 m ?JOO7 r1O:, CITY COPY THIS:BUILDINGS SUBJECT TO FIELD INSPECTION CORRECTIONS r. } Siil 4''"*. REVIEV t •° • SPOKDA 1@Li1 I L wtt Ar/V�IV`dSION 1F¶ 1p.'jl�tD: z •