Loading...
2013, 09-27 Permit App: BLD-2013-1984 Remodel Community Development Department (Staff Use Only) PermCenter S1170astSpr r East Sprague Avenue, Suite B-3 PERMIT NUMBER: 3 okane Spokane Valley, WA 99206 Tel: (509) 720-2540 PERMIT FEE: Valley. Fax: 688-0037 permitcenitcenter(alspokanevallev.orq RESIDENTIAL CONSTRUCTION PERMIT APPLICATION ❑ NEW CONSTRUCTION Z ADDITION/REMODEL 0 ACCESSORY BUILDING 0 DECK ❑'' OTHER SITE ADDRESS:15814 E 14TH VERADALE, ASSESSORS PARCEL NO :4524 0308 WA 99037 LEGAL DESC — 1 iFil RIPTI �F �%!3- BUILDING OWNER NAME:DAX&BECKY WILSON °_ 7t '.rv' :k " moi NAME:DAX&BECKY WILSON J 7 ii* ADDRESS:15814 E 14TH AVE • Citil) gf CITY:VERADALE STATE:WA ZIP;9 37 = PHONE:509-999-8044 FAX CE I.L:509-999- 044... . ....�:.:.���� f CONTACT NAME:JEFF HEINEMANN PHONE:509-844-1414 FAX: CELL:509-844-1414 CONTRACTOR NAME:HEINEMANN CONSTRUCTION LLC MAILING ADDRESS:PO Box 844 CITY:VERADALE STATE:WA ZIp:99037 PH ON E:509-844-1414 FAX CELL: CONTRACTOR LICENSE No.:HEINECL874CO EXPIRES:2/2015 CITY BUSINESS LICENSE No.:603-276-855 DESCRIBE THE SCOPE OF WORK IN DETAIL AND INDICATE USE & PROPOSED USE: -'T • - •- - • • e - e=' NSTALL A EW DOO' INTO THE :•THROOr ANP FUR A ALL OUT IN THE BATHROOM ****YOU M ST COMPLETE 1 E FOLLO ING***** MARK N A IF NOT APPLICABLE Height to Peak: Dimensions: No. of Stories: Total Habitable . Space: Main Floor SQ FT: Upper Floor SQ FT: Unfinished Basement SQ Finished Basement SQ FT: FT: Garage SQ FT: Deck/Covered Patio SQ Impervious Surface 30% Slopes on FT: Area: Property: 1 No. of Bedrooms: Construction Type: Heat Source: Sewer or Septic: TOTAL COST OF PROJECT: $2000.00 DISCLAIMER The permitted verifies, acknowledges and agrees by their signature that: 1) if this permit is for construction or on a dwelling,the dwelling is/will • be served by potable water. 2) Ownership of this City of Spokane Valley permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) The City of Spokane Valley permit is not a permit or approval for any violation of federal, state or local laws, codes or ordinances. 6) Plans or additional information may be requir d to be submitted and subsequently approved before this application can be processed. // ytutiotem ?/2.7//3 t Updat d 11 11 Page 1 of 2 C:\Users\Jeff\Desktop\Spokane Valley Building Permit.doc Signature Date: 400'44 r t410404111, ;. t Updated 1-11-11 Page 2 of 2 C:\Users\Jeff\Desktop\Spokane Valley Building Permit.doc BUILDING PLANNING ing buildings that are not already provided with an auto- doors, or the addition of a porch or deck, are matic residential sprinkler system. exempt from the requirements of this section. R313.2.1 Design and installation. Automatic residential 2. Installation, alteration or rs re aiof plumbingor P fire sprinkler systems shall be designed and installed in mechanical systems are exempt from the require- accordance with Section P2904 or NFPA 13D. ments of this section. R314.4 Power source.Smoke alarms shall receive their pri- mary power from the building wiring when such wiring is SMOKE ALARMS served from a commercial source,and when primary power is interrupted, shall receive power from a battery. Wiring shall I R314.1 Smoke detection and notification. All smoke be permanent and without a disconnecting switch other than alarms shall be listed and labeled in accordance with UL 217 those required for overcurrent protection. and installed in accordance with the provisions of this code Exceptions: and the household fire warning equipment provisions of NFPA 72. 1. Smoke alarms shall be permitted to be battery oper- R314.2 Smoke detection systems.Household fire alarm sys- tems installed in accordance with NFPA 72 that include Power. smoke alarms, or a combination of smoke detector and audi- 2. Hard wiring of smoke alarms in existing areas shall ble notification device installed as required by this section for not be required where the alterations or repairs do smoke alarms, shall be permitted. The household fire alarm not result in the removal of interior wall or ceiling system shall provide the same level of smoke detection and finishes exposing the structure, unless there is an alarm as required by this section for smoke alarms. Where a attic,crawl space or basement available which could household fire warning system is installed using a combina- provide access for hard wiring without the removal tion of smoke detector and audible notification device(s), it of interior finishes. shall become a permanent fixture of the occupancy and R314.5 Interconnection.Where more than one smoke alarm owned by the homeowner.The system shall be monitored by is required to be installed within an individual dwelling unit an approved supervising station and be maintained in accor- in accordance with Section R314.3,the alarm devices shall be dance with NFPA 72. interconnected in such a manner that the actuation of one Exception:Where smoke alarms are provided meeting the alarm will activate all of the alarms in the individual unit. requirements of Section R314.4. Physical interconnection of smoke alarms shall not be R314.3 Location.Smoke alarms shall be installed in the fol- required where listed wireless alarms are installed and all alarms sound upon activation of one alarm. lowing locations: Exception: Interconnection of smoke alarms in existing 1. In each sleeping room. areas shall not be required where alterations or repairs do 2. Outside each separate sleeping area in the immediate not result in removal of interior wall or ceiling finishes vicinity of the bedrooms. exposing the structure,unless there is an attic,crawl space 3. On each additional story of the dwelling, including or basement available which could provide access for basements and habitable attics but not including crawl interconnection without the removal of interior finishes. spaces and uninhabitable attics. In dwellings or dwell- ing units with split levels and without an intervening SECTION R315 door between the adjacent levels, a smoke alarm CARBON MONOXIDE ALARMS installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than R315.1 Carbon monoxide alarms.For new construction,an one full story below the upper level. approved carbon monoxide alarm shall be installed outside of R314.3.1 Alterations, repairs and additions. When each separate sleeping area in the immediate vicinity of the alterations, repairs or additions requiring a permit occur, bedrooms in dwelling units within which fuel fired appli or when one or more sleeping rooms are added or created ances are installed and in dwelling units that have attached in existing dwellings,the individual dwelling unit shall be garages. equipped with smoke alarms located as required for new R315.2 Carbon monoxide detection systems.Carbon mon- dwellings. oxide detection systems that include carbon monoxide detec- Exceptions: tors and audible notification appliances, installed and maintained in accordance with this section for carbon monox- 1. Work involving the exterior surfaces of dwell- ide alarms and NFPA 720, shall be permitted. The carbon ings,such as the replacement of roofing or siding, monoxide detectors shall be listed as complying with UL or the addition or replacement of windows or 2075. Where a household carbon monoxide detection system is installed, it shall become a permanent fixture of the occu- 2012 INTERNATIONAL RESIDENTIAL CODE® 63 2012 INTERNATIONAL RESIDENTIAL CODE R3143 Location. Smoke alarms shall be installed in the following locations: 1. In each sleeping room. 2. Outside each separate sleeping area in the immediate vicinity of the bedrooms. 3. On each additional story of the dwelling,including basements and habitable attics but not including crawl spaces and uninhabitable attics.In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels,a smoke R315.1 Carbon Monoxide Alarms. For new construction,an alarm installed on the upper level shall suffice for the approved carbon monoxide alarm shall be installed outside of adjacent lower level provided that the lower level is less each separate sleeping area in the immediate vicinity of the than one full story below the upper level. bedroom in dwelling units and on each level of the dwelling 4. In napping areas in a family home child care. and in accordance with the manufacturer's recommendations. R314.3.1 Alterations,Repairs and Additions. When alterations,repairs or additions requiring a permit occur,or R315.2 Carbon monoxide detection systems. Carbon when one or more sleeping rooms are added or created in monoxide detection systems that include carbon monoxide existing dwellings,the individual dwelling unit shall be detectors and audible notification appliances,installed and equipped with smoke alarms as required for new dwellings. maintained in accordance with this section for carbon Exceptions: monoxide alarms and NFPA 720-2012,shall be permitted. 1. Work involving the exterior surfaces of dwellings, The carbon monoxide detectors shall be listed as complying such as the replacement of roofing or siding,or the with UL 2075. Where a household carbon monoxide detection addition or replacement of windows or doors,or the system is installed,it shall become a permanent fixture of the addition of a porch or deck are exempt from the occupancy. requirements of this section. Exception: Where carbon monoxide alarms are installed 2. Installation,alteration or repairs of plumbing, electrical or mechanical systems are exempt from the meeting the requirements of Section 8315.1,compliance with Section R315.2 is not required. requirements of this section. (Insert Facing Page 63) Effective July 1,2013 • �-d�,' -�.} 04- Sit 1 a apt 7 s 7'7‘` ``� O C� xN N ,.,,... iq +- W 1 12' 1 111 1 /2 I N&I,J 1 etlinAt -- --?1 CL, I &"e°er CI , _ sn_ 1 11611-- C 10Set L ,B(1 , — - - - - _ C L, i... _ .... F-L'A,Arrviii) _.. _ ie yrov e.,curse lit\-- . ,r;vei CL 0 ,,.. (voy,- todw ow tr- &-ik (). ILD Balk _ n 3:11.1/41 " 33MALAMO3 300;') n. ' C if: Vtotaivo imicliluci ‘, .. — 1 A I 44. • + • 'ivy_ {REVIEWED FOR CODE COMPLIANCE _ CITY COPY