Loading...
2005, 09-12 Permit App: 05003276 Finish Basement Project Number: 05003276 Inv: 1 Application Date: 09/12/2005 Page 1 of 2 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Project Information: Permit Use: FINISH BASEMENT Contact: BLANCHARD,CASEY Address: 10306 E 15TH AVE C-S-Z: SPOKANE VALLEY,WA 99206 Setbacks: Front Left: Right: Rear: Phone: (509)922-3036 Group Name: Site Information• Project Name: Plat Key: 002704 Name: UNIVERSITY PLACE District: Sout Parcel Number: 45204.3824 Block: Lot: SiteAddress: 10306 E 15TH AVE Owner:Name: BLANCHARD,CASEY Address: 10306 E 15TH AVE Location::CSV SPOKANE VALLEY,WA 99206 Zoning: UR-3.5 Urban Residential 3.5 Water District: Hold: ❑ Area: .00 Acres Width: 0 Depth: 0 Right Of Way(ft): 60 Nbr of Bldgs: 0 Nbr of Dwellings: 1 Review Information: _ -ammerA . ea,. f ,. Review Plan Review Released By: Originally Released: 09/12/2005 By: TMELBOU Sewer Review Released By: Originally Released: 09/07/2005 By: cjjanssen Operator: CJJ Printed By: CJJ Print Date: 09/12/2005 Project Number: 05003276 Inv: 1 Application Date: 09/12/2005 Page 2 of 2 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Building Permit Contractor: OWNER Firm: OWNER Phone: (000)000-0000 This Application: Total Project: Description Grp Type Notes Sq Ft Valuation Sq Ft Valuation BASEMENT R R-3 VB 1,200 $6,000.00 1,200 $6,000.00 Totals: 1,200 $6,000.00 1,200 $6,000.00 Item Description Units Unit Desc Fee Amount RESIDENTIAL PERMIT FEE 1 SELECT $125.25 STATE SURCHARGE 1 SELECT $4.50 RESIDENTIAL PLAN REVIEW 1 SELECT $50.10 Permit Total Fees: $179.85 Payment Summary: ,gym:: -, .. Permit Type Fee Amount Invoice Amount Amount Paid Amount Owing Building Permit $179.85 $179.85 $0.00 $179.85 $179.85 $179.85 $0.00 $179.85 Disclaimer: Submittal of this application certifies the owner(or person(s)authorized by the owner)has both examined and finds the information contained within to be true and correct,and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for,or an approval of,any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: CJJ Printed By: CJJ Print Date: 09/12/2005 3 c --) ctTz cx Permit Center Sian` ne 11707E Sprague Ave,Suite 106 . Al 1+6 c "' ' r�, , ....ON/alley Spokane Valley,WA 99206 . :,,t,,,,;i4:344,4:! (509)688-0036 FAX: (509)688-0037 - Community Development www.s o, • valle '.or .com — D ECC -11V/ lc, Residential Constructi l n o Ne+vv-Construction o Accessory Bldg Permit Application D .4:1A s ►i i n/Remodel o Deck n J11 [l_, 1) F9to ' , SITE ADDRESS /01)6 L— /5- 7'4 /gv.P .S PD lcAit)e llecty .A/4_ qq?Otj ASSESSORS PARCEL NO: LEGAL DESCRIPTION: Building owner , .-. Cniaor Name: edL,s e, 5 zQ 1u r 22 Q,/, Name: Address: /0 3 0 f g— I� Fh /_-L - Address: City: S PO!(Apt 1/Da Zip: q 9 zo 6 City: Zip: Phone:q ZZ -363 6 Fax: Phone: Fax: Lic No: Exp.Date: ContactEe`rori City Business Lic No: Name: C aS ey 1z LA_N(2.Ki,a„fi(_ Phone: 92_?__ _201 c Describe the scope of work in detail: Cost of Project: $ 2_ 500 _ / /? model ' Iu— e.—,-, . **************The following MUST be complete: (write N/A if not applicable)********************** HEIGHT TO PEAK: DIMENSIONS: #OF STORIES: TOTAL HABITABLE SPACE: 2 1-/00 s. air MAIN FLOOR TO SQ. 2"" FLOOR SQ. FTG: UNFIN BASEMENT SQ. FTG: IMPERVIOUS SURFACE FTG: t AREA: FINISHED BASEMENT GARAGE SQ. FTG: DECK/COV. PATIO SQ. FTG: 30% SLOP S ON SQ. FTG: 1.- A 49✓t P ERTY: /c .21) #OF BEDROOMS: CONSTRUCTION TYPE: HEAT SOURCE: EWE R SEPTIC? DISCLAIMER The permitee verifies,acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling,the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal,state or local laws,codes or ordinances.6) Plans or additional information maybe required to be submitted,and subsequently approved before this application can be processed....: ,,� Signature 00.°-..--- � `�� ? ' ‘ Date 7' ' - 2—c% 5 Caod of Pa en t: (Faxed permit applications will only be accepted with major bankcard) sh l' ❑ Check 0 Mastercard ❑ VISA 0 Other Bankcard#: Expires: VIN#: Authorized Signature: REVISED 8/25/2005 �r1 Permit Center SO ikane 11707 E Sprague Ave, Suite 106% • .0,00 Valley Spokane Valley,WA 99206 (509)688-0036 FAX: (509)688-0037 www.spokanevalley.orz.com Community Development Residential Plan Submittal Minimums ❑ Completed Building, Plumbing & Mechanical application with: Accurate address, Parcel Number and/or Legal Description, description of work, owner and contractor information, signature, and date. ❑ Two sets of plans including Site Plan, elevations, floor plans, foundation plans With details, roof plan, framing plans & details. ❑ Show the height of any proposed buildings or accessory structures. ❑ Floor plan for each floor: Dimension to scale (minimum 1/8") and label each Room (including sq. footage of house and garage on plans) Show each level of existing house and square footage of any additions. ❑ All braced wall panel types: show locations and details of installation, including engineered design. ❑ Egress windows: Provide at least one window or exterior door approved for Emergency escape or rescue from a basement and in every room for sleeping. ❑ Smoke detector locations ❑ 22" X 30" attic access location ❑ 18" X 24" crawl space access: ❑ One-hour separation detail: between house and garage ❑ Floor framing details: Joist type, size, spacing and installation details ❑ Roof framing plan and details ❑ Furnace and hot water heater location. ❑ All header locations: type, size, and connections ❑ Foundation plan ❑ Insulation information WSEC TABLE 6-2 PRESCRIPTIVE REQUIREMENTS°.1 FOR GROUP R OCCUPANCY CLIMATE ZONE 2 Glazing Glazing U-Factor Doors' Wali 2 Wall? Wall? Slab8 Option Area70: U- Ceilings Vaulted Above Int~ e#' Floors on %of floor Factor CeilingsBelow Below Grade Vertical Overhead" Grade Grade I. 10% 0.40 0.58 0.20 R-38 R-30 R-21 R-21 R-12 R-30 R-10 int' II. 15% 0.40 0.58 0.20 R-38 R-30 R-19+ R-21 R-12 R-30 R-10 R-58 III. 17% 0.37 0.58 0.20 R-38 R-30 R-19+ R-21 R-12 R-30 R-10 R-58 IV. 25% 0.35 0.58 0.20 R-38/ R-301 R-21 R-15 R-12 R-30/ R-10/ Group R-1 U=0.031 U=0.034 int'/ U=0.029 F=0.54 Occupancy U=0.054 // Only 'V. J Unlimited 0.35 0.58 0.20 R-38 R-30 R-21 R-21 R-12 R-30 R-10 v Group R-3 int' Occupancy Only VI. Unlimited 0.32 0.58 0.20 R-38/ R-30/ R-21 R-15 R-12 R-30/ R-10/ Group R-1 U=0.031 U=0.034 int'/ U=0.029 F=0.54 Occupancy U=0.054 Only * Reference Case 0. Nominal R-values are for wood frame assemblies only or assemblies built in accordance with Section 601.1. 1. Minimum requirements for each option listed. For example, if a proposed design has a glazing ratio to the conditioned floor area of 13%,it shall comply with all of the requirements of the 15%glazing option(or higher). Proposed designs which cannot meet the specific requirements of a listed option above may calculate compliance by Chapters 4 or 5 of this Code. 2. Requirement applies to all ceilings except single rafter or joist vaulted ceilings. 3. Requirement applicable only to single rafter or joist vaulted ceilings. 4. Below grade walls shall be insulated either on the exterior to a minimum level of R-10,or on the interior to the same level as walls above grade. Exterior insulation installed on below grade walls shall be a water resistant material,manufactured for its intended use,and installed according to the manufacturer's specifications. See Section 602.2. 5. Floors over crawl spaces or exposed to ambient air conditions. 6. Required slab perimeter insulation shall be a water resistant material,manufactured for its intended use, and installed according to manufacturer's specifications. See Section 602.4. 7. Int. denotes standard framing 16 inches on center with headers insulated with a minimum of R-5 insulation. COOPERATIVE EXTENSION WSEC Builder's Field Guide 5th Edition WASHINGTON STATEUINTIVERSTTY 1.7 ENERGY PROGRAM ,8 ' `. ,., /3wth ►moo 04 t I shy r, EX ISS i4\ „, ,,, ,,,,, ,, ,,,,.., ,,,,,,.)- o ,.,,, _ \,..„,.. \iNN------: r. r yn ....... ______ WINDOW WELL: ,i,. 7--)i tMin. 9 sq. ft.horizontal area. t T Min. 3 ft. horizontal projection and width. I:, � 0 ---_____ ” Max. 44 in. vertical depth without a ladder .J ' a �� ,N f / INTERCON- NECTED RAND HARD WIRED IN SUCH A t,�16 f l/Y MANNER THAT THE ACTIVATION OF ONE EXHAUST FANS, J `"'` ALARM WILL ACTIVATE ALL ALARMS. 100 CFM kitchen t `)� (BEDROOMS, AREAS APPROACHING, 50 CFM bathrooms BEDROOMS, ' VAULTED CEILING 0 � � WITH RISE OF 24'&ON EACH FLOOR) &laundry U IA- \_\ V" 7,►, WHEN INTERIOR ALTERATIONS,REPAIRS OR ADDITIONS T� ` T` to hEOUIRING A PERMIT OCCUR,OR WHEN ONE OR MORE ly St EE PING ROOMS ARE ADDED OR CREATED IN EXISTING V, •ki' J a DWELLINGS.THE DWELLING UrST SMALL BE PROVIDED t9 WITH SMOKE ALARMS LOCATED AS REQUIRED FOR NEW " 0 - , DWELLINGS. la C t ;, I �!N1iPet ` rky EMERGENCY EGRESS REQUIREMENTS � ° ;4 L I-rc J N 1 ',,- * I, • FROM SLEEPING ROOMS -/- . , '�`i� 'b` `�`` Egress windows opens ' e' ' 1)NET CLEAR OPENING: 5.7 SQUARE ' '/i GRADE FLOOR OPENING(MAX 44') 5.0 SQUARE ' T ` b,-Z,' L )�/ 6}- 5,] SCI. ft. - " sill b r(,1, T CLEAR OPENING HEIGHT 24 INCHES " r / p 3)NET CLEAR OPENING WIDTH 20 INCHES �fe� '1 4)MAX FINISHED SILL HEIGHT 44-ABOVE •I$R rosin ^� `� 51 E MERGE NCY ESCAPE&RESCUE OPENING SHALL •4 _ OPERATIONAL FROM THE INSIDE OF THE ROOM WI • T • i.4.,cd 1L- 'r: ' , C3 JL THE USE OF KEYS OR TOOLS '�Ir 4i.4 Egress windows openable ►. ,.... 57sgft 44' sill - 1 .41-w • r - dr lie STAIRWAYS: Minimum width 36 in. with min. tread run of 10 in., max. rise of 7 3/4 in. &nosing o 3/4-1 1/4 in. Enclosed usable space under stairways requires 1 hour fire protection of V2 in. GWB LANDING required on both sides of exit doors with min.size of tr,N 3 ft.measured in direction of travel by 3 ft.or width of door if greater,and not lower than 1 %in.below threshold.Landing 1Q �� k required at other exterior doors is a minimum size of 3 ft travel „i distance by width of door,and not lower than 7 3/4 in. below (0E- threshold provided the door does not swing over the landing. 4;2\ 4 , 1. HANDRAILS: Height of 34—38 inches when required by four or more risers shall be continuous the full length of stairs with the ends returned or rounded.LANDINGS:Required min.width of 36 in. or width of stairway and 36 in.travel distance ' 2 K`(- u/h 3Az< -J PROVIDE DIAGRAMS AND ENGINEERING LAYOUTS FOR ROOF TRUSSES, BEAMS AND FLOOR SYSTEMS PRIOR TO FRAMING INSPECTIONS THIS BUILDING SUBJECT TO FIELD INSPECTION CORRECTIONS CITY COPY REVIEWED FOR CODE COMPLIANCE SPOKANE VALLEY^`'1! IN DIVISIO