Loading...
2013, 04-29 Permit: SW-13000547 Sewer SPOKANE COUNTY UTILITIES PERMIT Application Number: SW-13000547 Permit Issued Date: 04/29/2013 Expiration Date: 04/29/2014 Project Description: SEWER CONNECTION Project Name: VALLEYVIEW Primary Contact: M &L CONSTRUCTION INC Applicant: M &L CONSTRUCTION INC Phone: 509-466-6332 Address: 12918 N FREYA ST MEAD,WA 99021 Phone: 509-466-6332 Email: SITE INFORMATION: Site Address: 5723 E 16TH AVE Owner: RIFFE,THOMAS J &AMY S Parcel Number: 35234.0310 Address: 5723 E 16TH AVE SPOKANE,WA 99212 Phone: Assessor's Description: SLOANS ADD L10 B2 Email: Inspection Area: : (509)-477-3675 Water District: Spokane County Water Fire District: Spokane Valley Fire District#3 Zoning: Land Area: 13600 Square Feet CONTRACTOR INFORMATION: MLCONI*063N9, Exp. 09/03/2014 M &L CONSTRUCTION INC 12918 N FREYA ST MEAD,WA 99021 509-466-6332 DETAILS: Class Type Quantity Unit Charge Value SEWER SEWER CONNECTION 1 $125.00 $125.00 $125.00 FEE DETAIL: Processing-Utilities $26.32 Utilities Permit $125.00 Total Fee: $151.32 CONDITIONS: Plan review fee is required for all site plan reviews conducted by Spokane Valley Fire. Inside Public Transit Benefit Area Parcel within 100 feet of pipeline(s)owned by the following: (Yellowstone) CALL 1-800-424-5555 BEFORE YOU DIG--AT LEAST 2 WORKING DAYS IN ADVANCE. SPOKANE COUNTY CODE REQUIRES THE INSTALLER COMPLY WITH ALL REQUIREMENTS OF THE WA STATE DEPT OF LABOR&INDUSTRIES, INCLUDING THOSE RELATED TO TRENCH SAFETY. SEWER PERMITS ARE VALID FOR ONE (1)YEAR FROM THE DATE OF ISSUANCE. FOR SEWER INSPECTIONS CALL THE UTILITIES DEPT AT(509)477-3604 FROM 8:30-5:00 MONDAY-FRIDAY PRIOR TO COVER. ONE WORKING DAY NOTICE REQUIRED. PERMIT ALLOWS FOR A 30-MINUTE INSPECTION.ADDITIONAL INSPECTION FEES APPLY AFTER 30 MINUTES. Date Printed:04/29/2013 09:12:42 Project Coordinator:Julie Shatto SPOKANE COUNTY UTILITIES PERMIT Application Number: SW-13000547 Permit Issued Date: 04/29/2013 Expiration Date: 04/29/2014 THE SUBJECT PROPERTY HAS BEEN IDENTIFIED WITHIN PROXIMITY OF 100 FEET OR LESS FROM A KNOWN REGIONAL UNDERGROUND PIPELINE. IN ACCORDANCE WITH STATE AND FEDERAL NOTIFICATION LAWS,AND AS A CONDITION OF ISSUANCE OF THIS PERMIT,THE APPLICANT IS ADVISED OF THE REQUIREMENT TO CONTACT THE PIPELINE OPERATOR TO DISCUSS THE CONDITIONS AND LOCATION OF ANY PROPOSED EXCAVATION ASSOCIATED WITH THIS PROJECT PRIOR TO SUCH EXCAVATION OCCURRING. CONTACT INFORMATION FOR AREA PIPELINE OPERATORS IS AVAILABLE THROUGH OUR PROJECT COORDINATORS, OR AT THE FRONT COUNTER. RCW 19.122.033 INSTALLER IS RESPONSIBLE TO INSURE ALL WASTEWATER DRAINS ARE CONNECTED TO THE SEWER AND MAY BE REQUIRED TO PERFORM TESTS FOR VERIFICATION. INSTALLER IS TO FIELD LOCATE AND CONFIRM THE ELEVATION AND POSITION OF SEWER STUB PRIOR TO ANY OTHER EXCAVATION. SEWER STUBS AND DRY SIDE SEWERS ARE TO BE CHECKED PRIOR TO CONNECTION TO ENSURE THAT THEY HAVE ACCEPTABLE GRADE AND ARE CLEAR AND UNOBSTRUCTED. SEWER LINES SHOULD BE CONSTRUCTED TO ALLOW FOR GRAVITY FLOW FROM THE LOWEST LEVEL OF THE STRUCTURE. THE INSTALLER AND THIS PERMIT MUST BE PRESENT AT THE JOB SITE AT THE SCHEDULED INSPECTION TIME. BOTH STATE LAW RCW 19.122 AND COUNTY CODE REQUIRES THE INSTALLER TO GIVE NOTICE OF EXCAVATION TO OWNERS OF UNDERGROUND FACILITIES. Date Printed:04/29/2013 09:12:42 Project Coordinator:Julie Shatto