Loading...
2007, 05-31 Permit App: 07002059 Residence Project Number: 07002059 Inv: 1 Application Date: 5/31/2007 Page 1 of 2 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Project Information: Permit Use: SFR W/ATT GAR Contact: US POLE BUILDINGS Address: 9609 E MAXWELL C-S-Z: SPOKANE VALLEY,WA 99206 Setbacks:Front Left: Right: Rear: Phone: (509)220-9579 Group Name: Project Name: Site Information: Plat Key: 000368 Name: CHERRY ACRES SUB District: East Parcel Number: 45234.1514 Block: Lot: SiteAddress: 14815 E 16TH AVE Owner:Name: COMBS,JOHN&NANCY Address: 14815 E 16TH AVE Location::CSV VERADALE,WA 99037 Zoning: UR-3.5 Urban Residential 3.5 Water District: 010 VERA Hold: ❑ Area: .00 Acres Width: 0 Depth: 0 Right Of Way(ft): 0 Nbr of Bldgs: 1 Nbr of Dwellings: 1 Review Building Plan ReviewRe) ed By: Originally Released: 5/31/2007 By: TMELBOU Driveway/Approach Released$ „? Landuse/Zoning/HE Conditions Released B Operator: JD Printed By: JD Print Date: 5/31/2007 Project Number: 07002059 Inv: 1 Application Date: 5/31/2007 Page 2 of 2 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Building Permit Contractor: US POLE BUILDINGS Firm: US POLE BUILDINGS Address: 9609 E MAXWELL Phone: (509)220-9579 SPOKANE VALLEY,WA 99206 Building Characteristics Building Height 16 This Application: Total Project: Description Grp Type Notes Su Ft Valuation So Ft Valuation POLE BDLG U-1 VB 1,120 $21,280.00 1,120 $21,280.00 Totals: 1,120 $21,280.00 1,120 $21,280.00 Item Description Units Unit Desc Fee Amount RESIDENTIAL PERMIT FEE 1 SELECT $349.25 ACCESSORY PLANS REVIEW 1 SELECT $87.31 WSBC SURCHARGE 1 SELECT $4.50 Permit Total Fees: $441.06 Payment Summary �tM ._... x �x, ,> asr s... Permit Type Fee Amount Invoice Amount Amount Paid Amount Owing Building Permit $441.06 $441.06 $0.00 $441.06 $441.06 $441.06 $0.00 $441.06 Disclaimer: Submittal of this application certifies the owner(or person(s)authorized by the owner)has both examined and finds the information contained within to be true and correct,and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for,or an approval of,any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: JD Printed By: JD Print Date: 5/31/2007 Permit Center Scmof ... 11703E Sprague Ave, Suite B-3 . PERMIT NUMBER: pokane Spokane Valley,WA 99206 PERMIT FEE: \allev3 (509)688-0036 FAX: (509)688-0037 J www.spokanevalley.org Community Development Resid'entiaJ op rtion New Construction Accessory Bldg Permit Applicationn Addition/Remodel Deck fi ,, n Other: SITE ADDRESS: I y ear /- ASSESSORS PARCEL NO: LEGAL DESCRIPTION: Building Owner: Contractor: Name: /I c:// 47G)ze . /irej Name:4,3 4t,„___ re.,4, Address: a, r/ / &' // '7/✓ Address: PYc,C /11/4*-Xc €// City: ��,¢,yw State: it_ Zip: City:...5,/,/,04,.... f / Stater.. Zip f2 Phone:2_0 e - _et 2.,54/ Fax: Phone;cr. 2L _pi-7 Fax: Contractor Lic No: Exp Date: Contact Person City Business Lic.No: Name: f „ x,1,,,.5 Phone: Z,l c S-77 Describe the scope fro work ' dei ;': Cost of Project: $ , , T.5".74Cv'2- - S,�j ., pots/ v./ Proposed Use: 514," /-7-0, 1 `rn. **************The following MUST be complete: (write N/A if not applicable)********************** HEIGHT TO PEAK: DIMENSIONS: #OF STOR)ES: TOTAL HABITABLE SPACE: / ( CX fiVO1/ /z-X za l MAIN FLOOR TO SQ. 2ND FLOOR SQ. FTG: UNFIN BASEMENT SQ. FTG: IMPERVIOUS SURFACE FTG: , AREA: !/tea FINISHED BASEMENT GAGE SQ. FTG: DECK/COV. PATIO SQ. FTG: 30% SLOPES ON SQ. FTG: 0(� TY: #OF BEDROOMS: CONSTRUCTION TYPE: HEAT SOURCE: SEWS OR SEPTIC? The permitee verifies,acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling,the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal,state or local laws, codes or ordinances.6) Plans or additional information may be required to be submitted, and subsequently approved before this application can be processed. SIGNATURE: ,,,:,/,77,-, 7---/e------- DATE: Method of Payment: 0 Cash ❑ Check 0 Mastercard 0 VISA Bankcard#: Expires: VIN#: Authorized Signature: REVISED 2/15/07 SCITYpokane Valley® 11703 E Sprague Ave Suite B-3 • Spokane Valley WA 99206 509.688.0036 ♦ Fax: 509.688.0037 ♦ cityhall@spokanevalley.org Residential Plan Submittal Minimums El Completed Building & Mechanical application with: Accurate address, Parcel Number and/or Legal Description, description of work, owner and contractor information, signature, and date. ❑ Two sets of plans including Site Plan, elevations, floor plans, foundation plans With details, roof plan, framing plans & details. ❑ Show the height of any proposed buildings or accessory structures. ❑ Floor plan for each floor: Dimension to scale (minimum 1/8") and label each Room (including sq. footage of house and garage on plans) Show each level of existing house and square footage of any additions. ❑ All braced wall panel types: show locations and details of installation, including engineered design. ❑ Egress windows: Provide at least one window or exterior door approved for Emergency escape or rescue from a basement and in every room for sleeping. El Smoke detector locations ❑ 22" X 30" attic access location ❑ 18" X 24" crawl space access: ❑ One-hour separation detail: between house and garage ❑ Floor framing details: Joist type, size, spacing and installation details ❑ Roof framing plan and details ❑ Furnace and hot water heater location. ❑ All header locations: type, size, and connections ❑ Foundation plan ❑ Insulation information [L n ~'l u�� \�� L 1�L�' -� ' _\T�I." r---- - -------- - - -------------'-- ---'-----------------------�-'- . | . | - _ 's� ~� ^� | /-, J ~ � �� / � | | | | �r] ' ' �o(^���_ ! �j ' � ~ | � ! | | . ( | � . � | )' `,, | --- - f co ! | ` . •- ....„ ''- \ \ '/ ' �- --9Z" i 1 -- -c_ | ��0 d� / �j 3- | . _- ( . «n x O- � � fil a ' I -� \ -__ �' � n � _ � | ' ~ �� �T i ___-�Zo_-_-_- ' ' � ^j � | • . / • / ! i { / ! i 0y, (,,,,L4,,, ..c tJ , ....~ % `� � \ /1^7 ' r\ ,V N iJCT�`r�aarL PURLIN CONNECTION METHODS, A), PURLINS'MAY BE HUNG V. NAILS EACH GIRT OFF THE TRUSS TOP CHORD FACES W/ STANDARD SIMPSON JOIST HANGERS OR EQUAL, B). PURLINS MAY BE BUTTED AND NAILED W/(2) 16d NAILS (FLAT) INTO EACH PURLIN, C). PURLINS MAY BE LAPPED AND NAILED W/(3) 16d NAILS ON CONNECTION METHODS 'B' AND 'C', TOENAIL E OF TYPICAL.. GIRT CONNECTION w <) 16cl AILPINTCN EACH TOP CHORD ME NOTES FOR FLOOR PLAN ®1 INTERIOR FRAME WOOD POSTS, SEE POST SCHEDULE THIS SHEET GABLE WALL POSTS - 6' X 6' TYPICAL DOOR POSTS - 4' X 6' TYPICAL FOOTING DIMENSIONS, B + 1' 8'1 D = 3' 0' MAXIMUM POST SPACING 12' 0' (9)PURLINS @ 24' O.C., BEARING OR JOIST HANGERS (TYPICAL) w SPANS 12' TO 60' _ -- -�` x M. o U L9 ti w I a Li a iu>. JI a a DOUBLE TRUSSES �- �-- --------- - - V) Z L7V) W Z Jp J J w -I aw dW o. UJ h w a. 1 'p. X -i o OD o G o _J , x , v ... XW NN (U xp-' Of NV) 0_ -' N C3 OL w vwio _� `j0 D M - - DOUBLE TRUSSE -cr) - ti 3 ZOL _Ja za A >- m~ 6'U 1 i I- o - :3d I OL I- 1 o_ w o Zo 0 of Da I x� , xL3 X, ocur CU- Nv Ncu, N W OU W V) h N w SINGLE TRUSS PLAN VIEW N.T.S. SEE DETAIL SEE 1 10'-0" \� 12DETAIL 4 S2 .-._....... _ __.__ . 1 _ - NOTES FOR SECTION A -A 0 O 12'-0" ----- SS O TYPICAL PURLIN, SEE FLOOR 3'-0" N.T.S. 0.20 PLAN FOR SIZE L3 GABLE END 9 TRUSS DESIGN BY OTHERS -1 Z Z) 8 - �6cI NAILS S3 2' X 6' @ 24' D.C., 10' BAYS 6"X V' 20" T -W, 2' X 6' @ 24' D.C., 12' BAYS W E3 10'-0" SPLIT SLIDER DOOR OPTION DF -L #2 GIRTS FLAT @ 24' D, C. U 3'-0" S4 CONCRETE FOOTING, SEE SCHEDULE 1. V) 20'-0" SS EXTEND POST TO TDP OF PURLIN W W 2" X 6' BOLTING X 18" BLOCK ROOF FASTENED TO PURLINS WITH (/) 6" X 6" 26"T 1 1/2' LONG WOODFAST TEKS. S1 HALF TRUSS DESIGN BY OTHERS 12-0"_f07-0. ---0" WALLS FASTENED TO '4 S2 `2 X '10' HEADER UP TO 12' 0' DOORS GIRTS WITH I' LONG 0.41 ?' 12'4" ----- WOODFAST TEKS, -- 26" --- 3'-0" --- NO 0.41 BUILDING SECTION A -A ^ N.T.S. SINGLE OVERHEAD DOOR OPTION FRONT ELEVATION N.T.S. NOTES FOR FRONT ELEVATION S1 HALF TRUSS DESIGN BY OTHERS \ SUPPORT PURLINS @ END TRUSS W/2' X 6' OR 2' X 8' STD JOIST HANGERS, LOWER TRUSS FOR END OVERHANG, IF REQ'D S2 2' X 10' HEADER S3 2' X 6' GIRTS @ 24' D.C., 10' BAYS, DF -L #- 2' X 6' GIRTS @ 24' O,C., 12' BAYS, DF -L #( 0 2' X 8' FACIA BOARDS S5 TREATED WOOD POSTS, SIZED PER SCHEDULE S6 TREATED 2' X 6' BOTTOM GIRT OR TREATED 2' X 10' BOTTOM GIRT ti NOTES FOR CONNECTION DETAIL ' (SD TRUSS TOP CHORDS TRUSS DESIGN BY TRUSS MANUFACTURER (SD PURLIN SUPPORT STRUT 2: X '4' X FULL DEPTH OF TOP CHORD PLUS PURLIN, D,y NAIL PURLINS W/(3) 16d NAILS (SD NAIL STRUT TO TOP CHORD W/(3) 16cl NAILS EACH SIDE, S4 MANUFACTURED TRUSS, NOTCH POSTS 1-1/2' EACH 'SIDE TO PROVIDE TRUSS SEAT, (SD WOOD POST, SEE POST/FOOTING SCHEDULE, S6 4 - 40d GALV. NAILS IN PRE -DRILLED HOLES OR 3/4'0 MACHINE BOLT ts_31.on, Tn n, M- VT,Jt• -A- rnnn.lECTION POINTS. PLAN FOR SIZE GIRT M. BOLT O DOUBLE OVERHEAD DOOR ❑PTI❑N DE SAIL 1 TRUSS COLUMN OPTIONAL FRONT ELEVATION. N.T.S. CONNECTION. PURLIN SUPPORT 1 1„ 2 - 16d NA III ( III 6„ 3" OR -}It) 10" POST T -I ILS NAILING PATTERN FOR POST LAMINATIONS NOTE: 2" X 6" LAMINATE MUST BE A TREATED MEMBER AND MUST EXTEND TO THE BOTTOM OF THE FOOTING. LAMINATE MAY BE SPLICED ABOVE MID HEIGHT OF COLUMN NOTES FOR FOOTING DETAIL Si TREATED POSTS AS SIZED PER SCHEDULE 2 VIBRATE OR ROD CONCRETE TO OBTAIN FULL BEARING 53 UNDISTURBED SOIL Sl NOTES FOR DETAIL 2- KNEEBRACE S1 TRUSS TOP CHORD, DESIGN BY OTHERS 0 TRUSS BOTTOM CHORD, DESIGN BY OTHERS S3 2' X 6' DF -L #2 EACH SIDE 0 WOOD POST, SEE POST/FOOTING SCHEDULE SS 4 - 16d GALV, NAILS, EACH SIDE 1), KNEE BRACE REQUIRED WHERE SHOWN ON POST/FOOTING SCHEDULE, BRACE NOT REQUIRED AT GABLE END TRUSSES, 2), ALTERNATE KNEE BRACE/POST AND TRUSS/POST CONNECTION = USE 3/4'0 THRU BOLTS, EACH LOCATION. DEI AIL 2 - KNEE BRACE N.T.S. BUILDING SPECIFICATIONS: GENERAL - ALL BUILDING CONSTRUCTION SHALL CONFORM TO THE 2003 EDITION OF THE INTERNATIONAL BUILDING CODE (IBC 2003), AND ALL STATE & LOCAL BUILDING CODES. THESE SPECIFICATIONS AND PLANS ARE INTENDED FOR USE IN 30 OR 40 PSF LIVE LOAD, 85 MPH WIND SPEED, EXPOSURE B AND SEISMIC DESIGN CATEGORY C. DESIGN LOADS - ROOF LL = 30 OR 40 PSF ROOF DEAD LOAD = 5 PSF* CEILING LL = 0 PSF CEILING DL = 1 PSF • ROOF DL ALLOWS FOR A MAXIMUM OF 3" THICKNESS OF FIBERGLASS INSULATION. • MAXIMUM SOIL BEARING PRESSURE = 2,000 PSF MAXIMUM SOIL BEARING PRESSURE IS BASED ON SAND, SILTY SAND, CLAYEY SAND, SILTY GRAVEL AND CLAYEY GRAVEL SOILS OR BETTER LESSERSOIL CONDITIONS WILL REQUIRE REVIEW AND FOOTING SIZE ADJUSTMENT BY THE ENGINEER. CONCRETE - MINIMUM 28 DAY COMPRESSIVE STRENGTH F'c = 2,000 psi, 4 SACK MIX FOR FOOTINGS. CAST IN PLACE CONCRETE CONSTRUCTION SHALL CONFORM TO ACI 318-99. WOOD - STRUCTURAL LUMBER SHALL CONFORM TO DF -L #2OR BETTER BY WWPA GRADING RULES. MAXIMUM MOISTURE CONTENT SHALL BE 19% BY WEIGHT. NAILING SHALL CONFORM TO TABLE 2304.9.1 FASTENING SCHEDULE & OTHER APPROPRIATE SECTIONS OF CHAPTER 23 OF THE IBC. ALL NAILS INTO PRESERVATIVELY TREATED WOOD SHALL BE HOT -DIPPED ZINC COATED GALVANIZED STEEL, SILICONE BRONZE, COPPER OR STAINLESS STEEL. CCA TREATED WOOD -SHALL CONFORM TO THE REQUIREMENTS OF AWPA STANDARDS C-16, C-22, C-23, C-24 & C-28. POSTS FOR BUILDINGS SHAL! BE AS NOTED ON TI4E PLANS. ALL POST MATERIALS SHALL BE HEM -FIR #2 OR BETTER, FULL DIMENSION AND GRADED BY WWPA GRADING RULES. HARDWARE SHALL BE SIMPSON OR APPROVED EQUAL. ALL BOLTS SHALL CONFORM TO ASTM A307. METAL PANELS MAY BE DELTA RIB STYLE, GALVANIZED OR PAINTED, 29 GAUGE THICKNESS, ASTM A653 STRUCTURAL QUALITY (SQ), Fy = 80.0 ksi. ROOF PANELS SHALL BE FASTENED TO PURLINS WITH PLATED, GASKETED 1 1/2" LONG METAL TO WOOD FASTENERS. WALL PANELS SHALL B FASTENED TO GIRTS WITH PLATED GASKETED 1 OR LONGER META TO N NE BE TEN L WOOD FASTE ERS. PANELS SHALL BE INSTALLED AND FASTENED ACCORDING TO THE MANUFACTURER'S RECOMMENDATIONS. SOIL COMPACTION - ALL BACKFILLED SOIL BENEATH FOOTINGS SHALL BE COMPACTED WITH A VIBRATORY COMPACTOR TO 95% OF THE PROCTOR DENSITY AS DETERMINED BY ASTM A1557, METHOD D. TRUSSES SHALL BE DESIGNED BY AND BEAR THE SEAL OF AN ENGINEER REGISTERED TO PRACTICE IN THE STATE IN WHICH THE BUILDING WILL BE CONSTRUCTED. TRUSS LOADING: TOP CHORD LIVE LOAD = 30 OR 40 PSF TOP CHORD DEAD LOAD = 5 PSF BOTTOM CHORD DEAD LOAD = 1 PSF Iv - TRUSS WEB BRACING SINGLE SLIDING DOOR OPTION INTERIOR OR GABLE END TRUSSES OPTIONAL FRONT ELEVATION NOTES, FOR TRUSS WEB BRACING TRUSS DIAGRAMS WILL OFTEN REQUIRE WEB MEMBER BRACING, WHICH IS SHOWN ON TRUSS DRAWINGS ms N.T.S. THE METHOD OF TRUSS WEB BRACING SHOWN- ABOVE REPLACES 1' X 4' OR 2' X 4' WEB MEMBER BRACING FOLLOW THESE INSTRUCTIONS FOR ALL WEB MEMBER BRACING TO REPLACE 'RAT -RUN' WEB lOd NAILS @ 6' O.C. Od NAILS @ 6' O.C. X6"OR 2'X8' 'X4' L -BRACE L -BRACE ( -'" SHEATHING REE. IG OPTIONAL FRONT ELEVATION N.T.S. THE FOLLOWING MINIMUM ROOF DIAPHRAGM REQUIREMENTS ARE NEEDED. ■ ROOF STEEL, 29GAUGE .GRAND -RID 11I, 36' WIDTH OR EQUIVALENT ■ FIELD SCREWS, #10 x 1 1/2' AT 9' Q.C. (NEXT TO HIGH RIB) w EAV E AND RIDGE PURLIN SCREWS, #14 x1 1/2' AT BOTH SIDES OF EACH MAJOR RIB THE.FDLLOWING MINIMUM ENDWALL DIAPHRAGM REQUIRMENTS ARE NEEDED v ENDWALL STEEL, 29 GAUGE GRAND -RIB III, 36' WIDTH OR EQUIVALENT ■ FIELD SCREWS. #10. x 1 1/2' E 9' D.C. (NEXT TO HIGH RIB) TRUSS WEB MEMBER TRUSS WEB MEMBER ■ BASE GIRT, END TRUSS,AND DOOR HEADER SCREWS. 4114 x 1 1/2' 8 BOTH SIDES OF EACH MAJOR RIB. SECTION B -B SECTION B -B DIAPHRAGM SCREWS AT INTERIOR TRUSSES AT GABLE END TRUSS ENDWALL DOOR ,HEAD RS 6WGAHLEAENDG BUSS TOP CHORD, EAVE & RIDGE PURLINS ON ROOF Sl S3 S2 c S4 - S5 .TYPICAL TRUSS BOTTOM CHORD BRACING NOTES FOR TRUSS BOTTOM CHORD BRACING N.T.S. S1 GABLE END TRUSS S2 DOUBLE INTERIOR TRUSSES S3 2' X 4' X -BRACING @ 10' 0' O.C. S4 2' X 4' BOTTOM CHORD BRACING @ 10'-0' O.C. OR, AS SPECIFIED BY TRUSS MANUFACTURER SS TOENAIL BRACES TO TRUSSES WITH 3 - 10d NAILS TYPICAL SIDE ELEVATION NOTES FOR SIDE ELEVATIC N.T.S. SS 2' X 8' HEADER N S2 2' X 10' HEADER FOR 2' X 8' HEADER F05R 10' & 12' SLIDING DOORS ]R 8' & SMALLER SLIDING DOORS DIAPHRAGM SCREWS, .TYPICAL SCREW PATTERN, EXCEPT AS NOTED ABOVE STEEL SHEE-PING SCREW -PATTERNS 10'4" 10'-0" 6"X 6" T-12 41 1 _ - FOOTING SEE DETAIL 33 12'-0" ----- ff.. ... - NS" 3'-0" N.T.S. 0.20 10'-0" 10'-0" GABLE END TRUSS 3'-0" _ 30" 8 - �6cI NAILS 10'-V' __IT -O" 6"X V' 20" T -W, _NO NO 0.24 10'-0" SPLIT SLIDER DOOR OPTION 6"X 10" __ 20' 3'-0" OPTIONAL FRONT ELEVATION 10'-0" 20'-0" 8 - 16d NAILS 21' _Y 3'-6" 2" X 6' BOLTING X 18" BLOCK 12-0" N.T.S. NOTES FOR OPTIONAL FRONT ELEVATIONS 6" X 6" 26"T CORNER POST S1 HALF TRUSS DESIGN BY OTHERS 12-0"_f07-0. ---0" ---- 66"X 6" ---- S2 `2 X '10' HEADER UP TO 12' 0' DOORS NO 0.41 12-0" ---- 12'4" ----- 2' X 12' HEADER UP TO 20' 0' DOORS -- 26" --- 3'-0" --- NO 0.41 2' X 12' BACKED WITH 2' X 6' UP TO 24' 0' 14'-0" V 6" X 6" W/2" X 6" 8 - 16d NAILS S3 2' X C' HEADER Zn X 6' ° X 18, 96'-1" 6" O 8"W127 X 6" S HRU 14' 4' X;_6HEIGHT TFACER ATING BOCK 0.41 S4 W/OOR 2' X86 WALL6' DOOR POST - 16' & 18' 6"X B"w&_xX 6" _ 26' 3'-0" _NO _ NO HEIGHT W/ 2' X 8' FACER. 6' XLE 12'-0" 20'-0" 6" X 10" W/2" X 6" 26" 2"X 6' KINGPOST NO DE1 Ail. 3 I SCHEDULE 30' SPANS, WA�� - LIVE LOAD. POST COLUMN S5 DOUR CONCRETE „�,..•••.... TYPL GABLE END W X D "B" DIA. 'T' mkitarrnN VOLUME, YD 10'-0" B'-0" _ 12'-0" - 1W4"; --- THE FOLLOWING MINIMUM ROOF DIAPHRAGM REQUIREMENTS ARE NEEDED. ■ ROOF STEEL, 29GAUGE .GRAND -RID 11I, 36' WIDTH OR EQUIVALENT ■ FIELD SCREWS, #10 x 1 1/2' AT 9' Q.C. (NEXT TO HIGH RIB) w EAV E AND RIDGE PURLIN SCREWS, #14 x1 1/2' AT BOTH SIDES OF EACH MAJOR RIB THE.FDLLOWING MINIMUM ENDWALL DIAPHRAGM REQUIRMENTS ARE NEEDED v ENDWALL STEEL, 29 GAUGE GRAND -RIB III, 36' WIDTH OR EQUIVALENT ■ FIELD SCREWS. #10. x 1 1/2' E 9' D.C. (NEXT TO HIGH RIB) TRUSS WEB MEMBER TRUSS WEB MEMBER ■ BASE GIRT, END TRUSS,AND DOOR HEADER SCREWS. 4114 x 1 1/2' 8 BOTH SIDES OF EACH MAJOR RIB. SECTION B -B SECTION B -B DIAPHRAGM SCREWS AT INTERIOR TRUSSES AT GABLE END TRUSS ENDWALL DOOR ,HEAD RS 6WGAHLEAENDG BUSS TOP CHORD, EAVE & RIDGE PURLINS ON ROOF Sl S3 S2 c S4 - S5 .TYPICAL TRUSS BOTTOM CHORD BRACING NOTES FOR TRUSS BOTTOM CHORD BRACING N.T.S. S1 GABLE END TRUSS S2 DOUBLE INTERIOR TRUSSES S3 2' X 4' X -BRACING @ 10' 0' O.C. S4 2' X 4' BOTTOM CHORD BRACING @ 10'-0' O.C. OR, AS SPECIFIED BY TRUSS MANUFACTURER SS TOENAIL BRACES TO TRUSSES WITH 3 - 10d NAILS TYPICAL SIDE ELEVATION NOTES FOR SIDE ELEVATIC N.T.S. SS 2' X 8' HEADER N S2 2' X 10' HEADER FOR 2' X 8' HEADER F05R 10' & 12' SLIDING DOORS ]R 8' & SMALLER SLIDING DOORS DIAPHRAGM SCREWS, .TYPICAL SCREW PATTERN, EXCEPT AS NOTED ABOVE STEEL SHEE-PING SCREW -PATTERNS 10'4" 10'-0" 6"X 6" 18" 3'-0" NO 0.20 10'-0" ----- 12'-0" ----- 6"X6" -------- NS" 3'-0" NO 0.20 10'-0" 10'-0" 22'-0" 6" X IW' W/2" X 6" 3'-0" _ 30" 0.20 10'-V' __IT -O" 6"X V' 20" T -W, _NO NO 0.24 10'-0" _78'-0" 6"X 10" __ 20' 3'-0" NO 0.24 10'-0" 20'-0" 6" X 10" 21' _Y 3'-6" __ NO 0.27 12-0" 8'-0" 6" X 6" 26"T -W, NO 0.41 12-0"_f07-0. ---0" ---- 66"X 6" ---- 26" _ 3'4" NO 0.41 12-0" ---- 12'4" ----- 6" X W/2" X 6" --------- -- 26" --- 3'-0" --- NO 0.41 12-0" 14'-0" V 6" X 6" W/2" X 6" 26"3'-0" NO -- 0.41 12-0" 96'-1" 6" O 8"W127 X 6" 26" 3'A" 0.41 12-0" lwoe 6"X B"w&_xX 6" _ 26' 3'-0" _NO _ NO 0.41 12'-0" 20'-0" 6" X 10" W/2" X 6" 26" 3'-2" NO 0.44 POST/FOOTING SCHEDULE 30' SPANS, 30 & 40 PSF LIVE LOAD. POST COLUMN FOOTING KNEE BRACE CONCRETE SPACING "H" W X D "B" DIA. 'T' REQUIRED VOLUME, YD 10'-0" B'-0" _ 12'-0" - 1W4"; --- G" X 26" 3'-0" NO 0.41 0.41 0.41 0.41 ----- 10'-0"-4'-0 ----- _6" 6" X 6" W/2" X 6" ---- -- ---- 6" X 6" W/2" X 6" --- 2i;;--3'-0" 26" 3'-0" 3'-0" _ _ NO NO NO - 16'-0" 6" X 8" _26" 26' _y:5;r0.41 NO 0.41 10'4" 18'-0" 6" X 8 W/ " 2" X 6" 26" 3'-0" id0 ­ 0.41 0.41 20'-0" 6" X 8" W2" X 6" 26" 3'-0" NO 6" X 10" W/2" X6" 26" NO 0.44 10'-0" 24'-0" 6" X 12" 26" _3'4 3'3" NO 0.45 12-0" 8'-0" 6" X 6" 28"3'-0" NO 0.47 ---- --- ----- ---- " 283'-0" _ 0.47 12-0" 12'-0" X 6" W/2" X 6" 28" 3'-0" _NG NO - 0.47 12-0" 14'1"' W 6" X 8" 28" 3'-0" NO 0.47 _12:0 16'-9'° 6'' X 8" W/2" X 6" - 3'-0" NO _ 0.47 124' _ 18'-0" 20'-0'' 6" X W'___ _28" 3' -NO 0.47 0.47 12-0" 6" X 12" _ _28"0"_ 28" 3'-0" __ _ NO 124' - 124' --2Z-V'- M -V' 6"X 12"W/2" X 6" 28' 3'-2" _ NO 0.5 0.56 V' X 12" _ 28'' _ 3'-6" NO - POST/FOOTING SCHEDULE 36' SPANS, 30 & 40 PSF LIVE LOAD. POST COLUMN FOOTING I KNEE BRACE CONCRETE SPACING "H" W X D "B" DIA. 'T' I REQUIRED VOLUME, YD 10-0' 8-0 _6'X6" 28" 3-0 NO 0.47 10-0 10 .0__ 10-0' "U-0 12-0 14-0 6 X6 6 X6 W/2 X6" 28" 314;__ _ NO 0.47 0.47 0.47 28" 34 _K0 6-X6 WJ2"X6" 28" 3-0 - NOO 16 -0 6' X 8" 28" 3'-0" NO 0.47 1 e -0 6' XX 888'W/2" X 6" 28" 3'-0" _ O_ 0.47 _ _, 0.47 10'-0" 2T -O" 6" X 10" W/2" X 6" 28' - NO 0.47 0.50 10'-0" _ _ 24'.0" 6" X IV'WIZ* X 6" _ 1 28" _3'-0" _ T-2" _ I YES - 12-0" 8'.9' 6 X 6" 32" 3'.V' NO 0.62 0.62 0.62 12-0 12-0' 10 -0 12'4'- _ 6 X 6" _ 32"_ 3-0 T -W _ _ _ NO NO 6 X 6" W/2" X 6" 32" 124' 14.0 6 X 8" NO 0.62 12-0" 16'-0" 6" X 6" W/2" X 6"_ _32---3-0 32" 3'-V' NO 0.62 12-0" 18'-0" 6" X 10" 22" T:6; NO_ 0.62 12-0'' 20'-0" 6" X 10" W/2"X 6" 32' 3'-0" NO 0.62 12-0" 124' 22'-0" 7W.9- 6" X 12" 6" X 12" W/2" X 6" 32" 32" 3'-2" 3'-0" NO NO 0.66 0.66 POST/FOOTING SCHEDULE 40' SPANS, 30 & 40 PSF LIVE LOAD. 12'-0" 6" 10'-0" 14%0" 6" X 6" W/2" X 6" 0.55 0.55 0.55 0.55 0.55 0.55 0.55 - 0.55 0.58 YES_ 6" X 8" - 10.0'._. -16-0 6"X8"W@^x6".. _ 10'-0" 30' Y-&_VE3 _ 30" 3'4" 10'-0" 22'-0" 6" X IW' W/2" X 6" 164" IV X8" 6" X 10" 6-, X 12" 24'-0'' 6" X 12" 30" T-91 NO 0.55 0.55 0.55 0.55 0.55 0.55 0.55 - 0.55 0.58 YES_ NO YES- NO 30"_ NO - NO 30' Y-&_VE3 _ 30" 3'4" _ NO 30' _&_ _ 30" _ 3'-0" _NO NO 300" W. NO 30' 3'-2" YES 33" 3'-0" NO.- 0.66 0.66 0.66-. 0.6E 0.66- 0.66 0.66 - 0.70 33' 3-4- NO 33" 3-0 NO 33" 33" 3-0' 3'•0" _ NC _- NO - 33" 33" T -T' NO NO0.70 '- 0.70 0.70 0.70 0.70 0.70 0.70 0.70 0.70 NC_ _ NO _ NO NO YES_ NO YES- NO 0.79 0.79 0.79 0.79 0.79 0.79 0.79 0.83 NO NO "NO_-_-_, NO _ YES_ NO NO N .. 1U -u'_- 7u'.U" 6"X6" 36" 3'-0" NO 0.79 ..... TS :-: - 10.0'• 12'-0" V X 6" W/2„ X 6„ 36„ 3',0'• NO 0.79 '.. --- - ---- - ---- 36" 3'-0" NO 0.79 ',.. 1 .11 .2ll X6 36 -0 3NO 0.79 10'-0" 18-0 .6'X10" 26'_ 3'4' NO 0.79. 20 -0 6' X 10'' W/2" X 6" 36" 3'-0" YES 0.79 ---- - --- 6" X 10" W/2" X 6" 36" 3'-0" _40 0.79 _ 104" 24'-0" - 6" X 12" 36" 3'-2" YES 0.83 12-0" 8'-0" 6" X 6" 40" 3'4" NO 0.97 12-Y' - -10'-0" _ 6" X 6" W/2-, X 6" 40,--0, -3, NO -- 0.97 $ 2-0'_ -ili­O" 66"X B" 40" 3'-0" N_ O_ 0.97 12-0" 14-0 6 X8"WIZ' X6"40'_ 3-0_ NO 0.97 H'NO 0.97 W y�. 12-0'^ . 18 -0 6 . X 8o W/2" X 6" 40' 3 -0 YES 0.97 �XPti p 12-0"- _ 20'-0" 6„ X 10" W/2•' X 8„ 40" 3'-0'• NO -NO 0.97 - 12-0" 22'-0" 6" 12 W/2" X 6 40" 3'-0" NO 0.97 T 7%F I1} JE -0„ - - 24'-0" V' X 12" W/2•'X 6„ 40,E - 3,-T;- NO 1.03 .FpL(]dBWXOTL RGER SIZE POST MAY BE SUBSTITUTED FOR POSTS WITH J� "J R1IST8ILF' LAMINATIONS. 2. ENDWALL POSTS SMALL BE 6" X 6" ROUGH CUT HEM -FIR #2 TREATED /OVAL ti� POSTS UP TO 16'-0" WALL HEIGHT. ABOVE 16' WALL HEIGHT, ENDWALL POSTS SHALL BE 6" X 8" ROUGH CUT HEM -FIR #2 POSTS. 3. FOOTINGS FOR ENDWALL POSTS SHALL BE A MINIMUM OF 20"0 X EXPIRES (�!()y [/ 3' -0 -DEEP FOR WALL HEIGHTS TO 16'-0". ABOVE 16' WALL HEIGHT, FOOTINGS SHALL BE 24"0 X 3'-4" DEEP. 4. ABOVE FOOTING DESIGNS ARE FOR POST FRAME BUILDINGS WITH - _ . CONCRETE FLOORS (CONTRAINED POSTS). IF BUILDINGS WILL NOT HAVE `"------ CONCRETE FLOORS, INCREASE FOOTING DIAMETER X 2" & FOOTING DEPTH X 4". WAMBEKE ENGINEERING 2913 E. 61st Court Daniel Wambeke P. E. Spokane, WA 99223 Telephone, 509-44376186 Fax, 509-448-6582 a -mall dwambeke@msn.com LAYOUT, STRUCTURAL DETAILS AND SPECIFICATIONS POST FRAME BUILDINGS 30 & 40 PSF LIVE LOAD U. S. STEEL POLE BUILDINGS 9609 E. MAXWELL SPOKANE VALLEY WASHINGTON 99206 BY DATE DRAWING NO., REV. DRAWN WAMBEKE t1-11-06 U.S.STEEL.IBC2003-0 X CHECKED :IPTION OF CEt PROJECT NO' 2006 SCALE, N.T,S. SHEET. I OF 1 PROVIDE DIAGRAMS AND ENGINEERING LAYOUTS FOR ROOF TRUSSES, BEAMS AND FLOOR SYSTEMS PRIOR TO FRAMING INSPECTIONS CITY COPY THIS BUILCiNG SUBJECT TO FIELD INS/2E0' COgRECTIONS Scan ,..-.. REVIEWED FOR CODE COMPLIANCE SPOKANE VALLEY BUILD G DI SION