Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
1997, 05-27 Permit: 99002621 Energy Code Compliance
WATTSUN 5. 5 1994 W, , ,TATE Ei'ERGY CODE COi'IF'L I A,,_- REPORT 05/27/97 FILE: C: \\WATTSUN5\\HD16i5LC.WS HOUSE ID: H DOUGLASS 1.615 L CT E.15916 16th Analyst: TAS Jurisdiction : Spokane County Utility : WW • Homeowner: House Type: Single Family -Floor Area: 3254 ft2 Builder: Harley Doualass Weather Data: Spokane, WA Climate Zone: 2 ( 509)4G7-5792 • Tne t'•tiurubt1J oesian *LUI'It'•L1ESfi- •with 199•4 WH State Eneray Code. REFERENCE rruruED Cui'IFONEW T FERFORHANCE 631 629 Btui hr-F . ENERGY BUDGET 9.61 10. 11 i:.Wn/ Tt2-vr REFERENCE DESIGN Reference Component Value X Area = UA BG Wall u-0:04i 175 5. 5 Lill Slab 3. 5 F-0.640 _Gft 24.3 BG Wall U-0.037 1236 45.7 Lill Slap / F-0. 5/0 155Tt GG._` Floor U-0.029 • 7 1 . i blazina 'a15 U-0.6o: 492.6 295.6 Doors U-0.390 61 .0 23.5 AG Wail • U-0.062 1499 Ceiling , Attic U-'•_i.t)•_Yi 1531 47. 5 Ceilina, Vault U-0.0=4 172 5.5 infiltration ALM-U.._p'_! 17763Tt3( 107.b ) Reference. UA 63i rr•;urubEll Ut.L b1`a LUI it UPiEi`I i Component DescriptionValue X Area = UA BG Wall ttu Uninsulated ti depth • U- i 135 =6.6 55 Slab F-'). Sit • 3 STt 19.4 BG Wall • Rt) Uninsulated % depth U-0. 185 1236 • 228.7 Items in parentheses not included in LUMF'UI`iCIV T totals. #.* Denotes non-standard Values - check calculation of thermal value. F a o e 1 INH 1 SUN .5. 5 1994 WH 'TATE EI'JERG Y CODE LUI'iI-L 1 P-U\11_ REPORT 05/27/37 FILE: C: \\WATTSUN5\\HD1615LC.WS HOUSE ID: I-I DUUGLASS 1615 L CT Sb Slab F-0.434 155Tt 67.3 Floor R•-!i vented Joist .LboC lJ-'•_t.!_! .JiJ 1 . 1 blazing 'p7% **2 al Vinyl wi J.ow-E av U-Tactor U-10. 400 2-67.7. 5 113. 4 Doors 2a1 Full Lite ins 1/2" Cir U-0.760 21 .0 7.6 .*Pieta' i •_/ LF" . urethane flush U-0. 100 1-7.0 1 .9 !I!*i'ietal 1 .3/4" urethane panel U-0. 1401 .0 AG Wall Ri7f INT Lap Wood U-0.058 170B yy. 1 Ceiling R30 batt Vault vented 2•LL2 24oc U-0.077 172 =1,- ;- rd 7: 12/7: 12 Scissor STD U-0.031 57; 16. **R•_'G 7: 12 b I L' U-0.029 934 27. 1 infiltration Standard Air Sealing ALM-').750 1ii63Tt: ( 1'J7.6 ) Proposed UA 629 Strut Hass Light Frame, Sheetrock walls N- 3.000 166.1 LF9 **Slab no Cover I'I-10.00 1623 16230 HEATING/COOLING/VENTILATING SYSTEHS PROPOSED Heating System Type: Gas Furnace Hake: Unknown/ Node1 : Unknown/ System Efficiency : e: Nodif.ied Efficiency : 76 % Design ACH: 0.60 Design Loaf] ! at 66F Ott : 54911 Yttui•nr Duct Losses(% Dsn Load ) : !J Stu/hr i 0%) Total Load : 54511 tttu/ fir System Si:e(output ) : 112500 rtuihr ( 150%) Average Annual Heat: .L4: Annual Cost: BOO Ventilation System: Integrated wiForced Air Furnace Cooling System: NONE SEER: 0.0!=! i inducted ) Cool ino Load (at 12F Cit) : Ln- tui hr System Sizei i:uver) : tons i '1125) Annual Cool Requirement: kWh/yr Solar Access: Partially Shaded -_.- -------- I-'etoe WA Y'1 SUPS► 5. 5 1594 WF-, TATE I t ENERGY LODE CONE L I AI'.. REPORT 05/27/97 FILE: C C \•\WAT T SUN \\HD161 LL.W5 HOUSE ID: H DOUGLASS 1615 L LT 1-'t<UI-'UbtU UUL T SYS 1-t)'I Location AVO F:value Surface Area SUPPLY All in heated space RETURN Ut'.IV All In Heated space GLAZING ORIENTATION t'KUr'Ubtw PROPOSED South • ft2 North • ft2 Southeast : Northwest . East West Northeast : 145. 5 Southwest 135.0 ETT b VIZ . 2.4% Economic and energy consumption estimates are designed for comparative purposes only . Actual cost for heating will vary dependina on weather conditions, occupant lifestyle and other factors . - -- - --- Pace rage - ----- --- -- --- ----------=-----.--•----