Loading...
1992, 12-01 Permit: 92010515 Energy Code Compliance WAl T SUN 5. 1 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 12/01/92 t::: \WA1 151 N`_5\9;'1,:3SG'aI: C. Ws HOUSE:- ID: Emerald Marquise - 3 ,� car • itn : 5308 E. 18th Lane Analyst : Dave Baker • Spokane, WA 99.:'.121 jurisdiction : Spokane County Building Utility : Washington Water Power Homeowner: Mail : Floor Area: 3957 ft2 Builder: BAKER BUILDERS Weather Data: Spokane, WA Address : E. i.E31212 Trent Ave Climate Zone : 2 I i The PROPOSED design *COMPLIES* with 1991 WA State Energy Code. I I REFERENCE PROPOSED I COMPONENT PERFORMANCE 735 747 Btu/hr-F I ENERGY BUDGET 10. 41 9. 38 kWh/ft2-yr I 1 REFERENCE DESIGN Reference Component Value X Area = UA BG Wall U-0. 043 806 34. 7 BG Slab F-0. 690 146ft 100. 7 On Grade Slab F-0. 540 20ft 10. 8 Floor U-0. 029 164 4. 8 Glazing @15X U-0. 600 593. 5 356. 1 Doors U-0. 400 53. 0 21. 2 AG Wall U-0. 062 2763 171. 3 Skylights U-0. 031 4. 0 0. 1 Ceiling U-0. 031 1614 50. 0 Infiltration -- -- -- Reference UA 735 PROPOSED DESIGN COMPONENTS Component Description Value X Area = U/i BG Wall RO Uninsulated 2' depth U-0. 350 82 28. 7 BG Slab F-0. 590 41ft 24. 2 R0 Uninsulated 7 ' depth U-0. 193 648 125. 1 F-0. 460 82ft 37. 7 R0 Uninsulated 3. 5' depth U-0. 278 76 21. 1 F-0. 530 23ft 12. 2 Items in parentheses not included in COMPONENT PERFORMANCE totals. ** Denotes non-standard values - check calculation of thermal value. Page 1 4 ' WATTSUN 5. 1 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 12/01/92 FILE: C: \WATTSUN5\9218SPEC. WS HOUSE ID: Emerald Marquise - 3 car On Grade Slab R10 2' vertical F-0. 540 20ft 10. 8 - Floor R25 unvented Joist 16oc U-0. 033 164 5. 4 Glazing @15% **2GL NWA Vinyl Stnd - HS U-0. 440 104. 0 45. 8 **2GL NWA Vinyl Stnd - HS U-0. 440 286. 0 125. 8 **2GL NWA Vinyl Stnd - HS U-0. 440 193. 0 84. 9 2G1 Vinyl 1/2" U-0. 540 20. 0 10. 8 Doors Metal 1-3/4" urethane flush U-0. 140 53. 0 7. 4 AG Wall R19 ADV Lap Wood U-0. 055 408 22. 4 R19 ADV Lap Wood U-0. 055 1225 67. 4 R19 ADV Lap Wood U-0. 055 1061 58. 4 R19 INT Ti-11 U-0. 061 60 3. 7 Skylights 2G1 Alum w/TB 1/2" U-0. 730 4. 0 2. 9 Ceiling R38 blown Attic STD baffled U-0. 031 1119 34. 7 R38 blown Scissor 5: 12 STD baffled U-0. 035 495 17. 3 Infiltration Standard Air Sealing ACH-0. 350 29315ft3 ( 177. 5) Proposed UA 747 Struc Mass Light Frame, Sheetrock walls M-3. 000 2522 7566. 0 Slab w/carpet w/pad, Sheetrock wall M-5. 000 1435 7175. 0 HEATING/COOLING/VENTILATING SYSTEMS PROPOSED Heating System Type: Gas Furnace Make: Trane 90 + Model: to be determined/ System Efficiency: 92 Modified Efficiency: 87 Heating Load( at 80F dt ) : 79820 Btu/hr System Size: 79820 Btu/hr Maximum Size @150% : 119730 Btu/hr Average Annual Heat: 165 MBtu Annual Cost : S 922 Ventilation Type: Non-Heat Recovery Option: Option 4 Cooling Load(at 12F dt ) : 52622 Btu/hr Recommended Size @125%: 6. 1 tons Solar Access: Shaded Page • WATTSUN 5. 1 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 12/01/92 FILE: C: \WATTSUN5\9218SPEC. WS HOUSE ID: Emerald Marquise - 3 car PROPOSED DUCT SYSTEM Location Avg Rvalue Surface Area SUPPLY All in heated space R- 8. 0 791. 4 ft2 RETURN All in heated space R- 8. 0 158. 3 ft2 GLAZING ORIENTATION PROPOSED PROPOSED South : 16. 8 ft2 North : 0. 0 ft2 Southeast : 79. 0 Northwest: 27. 5 East : 0. 0 West: 16. 7 Northeast : 178. 0 Southwest : 285. 0 Economic and energy consumption estimates are designed for comparative purposes only. Actual cost for heating will vary depending on weather.• conditions, occupant lifestyle and other factors. --_ - Page 3 -...--