Loading...
1992, 01-29 Permit App: 92000517 Residence SPOKANE COUNTY DEPARTMENT OF BUILDINGS W. 1303 BROADWAY AVENUE SPOKANE,WASHINGTON 99260 (509)456-3675 I certify that I have examined this permit/application,state that the information contained in it and submitted by me or my agent to compile said permit/application is true and correct, and uthorize Swm County to proceedvmmvmooss.no In additionI have reaand understand the INSPECTION REQUIREMENTS/NOTICE provisions included herein and agree to comply with same.All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not.I understand that the issuance of this permit/application and any subsequent inspection approvals or Certificates of Occupancy shall not be construed to give authority to violate or cancel the provisions of any state or local law regulating construction,or as a warranty of conformance with the provisions of any state or local laws regulating construction. SIGNATURE OF APPLICATION OWNER OR AGENT DATE PROJECT NUMBER= 92000517 APPLICATION DATE= 01 /29/92 PAGE= Oi ****** THIS IS NOT A PERMIT ****** PENALTIES WILL BE ASSESSED FOR COMMENCING WORK WITHOUT A PERMIT_______ --_----- -- ----------------------__-------_- -�r-------------t). ^�iz?_ ^� . '' ^SITE STREET= 5421 PARCE4= 26534 -1086 ��% PARCEL i ADDRESS= SPOKANE WA 99202 PERMIT USE :: RESIDENCE - NATURAL GAS PLATO= 005025 PLAT NAME=�� DEVONRIDGE R-3 5 DI%T�= E BLOCK= i u/ = z Z (} ^unc- � 86 = DEpTH 124 R/W= 30 0 OF BAREA= 4 DWELLINGS= F/A= F iWIDTH=WATER DIST = SPO CO WATER DI%T43A OWNER= BAKER BUILDERS PHONE= 509 534 4500 STREET= 1882 E TRENT AVE ADDRESS= SPOKANE WA 992.02. CONTACT NAME= DAVE BAKER PHONE NUMBER= 589 534 4500 BUILDING SETBACKS : FRONT= 27 LEFT= 5 RIGHT= 45 REAR= 504- ***********:******************* 0+****************************** REVIEW INFORMATION ************************** DEPARTMENT ___REVIEW_COMMENT% '�� COMMENTS __________�_ __________________ ---------- �� ���BUILDING PLAN PLAN REVIEW REQUIRED --- ��-' -" �� ' --BUILDING SETBACK%ETBACK REVIEW REQUIRED --- ' -�� "=^" - ��---------- ENGINEER APPROACH/FLOOD PLAIN/DRAINAGE ' - --- - -- , ******************************* BUILDING P : MIT ************* '************** CONTRACTOR= BAKER BUILDERS PHONE= 509 534 4500 STREET= 1802 E TRENT AVE ADDRESS= SPOKANE WA 99202 NEW= X REMODEL= ADDITION= rHANIEOFU%F= DWELL UNITS= 1 OCCUP. LD= BLDG nG / = / STORIES= BLDG pWXD� �HAN = X %QCM FT= 3752 SPRINKLER= N REQ PARKING= T= N ******************************* MECHANICAL PERMIT ************************** CONTRACTOR= MCCLEARY HEATING & AIR COND PHONE= 509 838 8426 STREET= 2714 % WALL %T ADDRESS= SPOKANE WA 99203 ***************************** PLUMBING PERMIT ****************************** CONTRACTOR= RICK ' SPLUMBING & HEATING PHONE= 509 534 4090 STREET= BOX 3874 ADDRESS= SPOKANE WA 99220 PROCESSED BY : WENDEL/ GLORIA PRINTED BY : WENDEL, GLORIA ******************************** THANK YOU ********************************* • • NOTICE It is the responsibility of the permittee, not Spokane County, to see to it that the use described on the front of this permit complies with applicable codes and requirements and that required inspections are requested. Failure to request required inspections and obtain the necessary approvals prior to progressing beyond the point where inspections are. required may necessitate removal of certain parts of the construction at the owner's/permittee's expense. At a minimum, the following inspections ARE REQUIRED by County Code: 1. FOOTING — when forms and reinforcement am in place and prior to placement of concrete. NOTE:This inspection includes review of the structure's setbacks born property lines.Minimum setbacks are established by County zoning regulations. Typically,side and rear yard setbacks are rrieasured from property lines, while setbacks for yards abutting streets are measured from the property line or the center iine of trie roadway right–et-way,whichever provides the greater setback from the center line of the roadway right-of-way. Curb lines and fence lines are not necessarily indicative of property lines.in some residential areas,the County can own as much as 20 feet of right-of-way between your property and the actual improved street/curb. The responsibility to comply with applicable setback provisions lies solely with the permittee neither Spokane County nor its -authorized representatives assume any responsibility for the verification or location of your property lines,Please verify their location prior to locating your structure.Failure to properly locate the structure may require its relocation at the owner's/permittee's expense. 1 2. FOUNDATION when forms and reinforcement are in place and prior to placement of concrete.(Blocking fora manufactured home is required to be inspected prior to the installation of skirting.) 3. FRAMING after all framing, bracing and blocking is in place, and prior to concealing, 4. INSULATION prior to the installation of drywall. 5. PLUMBING after rough-in, before covering, anct 6. MECHANICAL rough-in of piping, before covering, metal chimneys before concealment, and final. 7, FINAL— when complete and prior to occupancy arid/or use. Please provide 24 hours notice. NOTE:In addition to inspection of the structure,this inspection includes review of site improvements(typically depicted on the approved site plan)required by ordinance or as a condition of approval of this permit.items such as the installation of fire hydrants,fire department access,on-site drainage("208 swales"),road improvements, parking,and landscaping are common requirements of a permit/site plan which must be completed prior to final approval of a building or issurance of a Certificate of Occupancy. In addition to the above any plumbing or mechanical systems or materials which would be concealed by framing, drywall, concrete, etc., must be inspected prior to cover. Check with the department for "special inspections" in conjunction with commercial projects. CALL 456-3675 FOR INSPECTIONS. TO INSURE PROMPT SERVICE, PLEASE GIVE 24 HOUR NOTICE. YOUR INSPECTOR IS „ UNDER CERTAIN CIRCUMSTANCES, PARTS OF "(OUR PROJECT MAY REQUIRE INSPECTIONS FROM OTHER AGENCIES: • road cuts for utilities or drives, State or County Engineer's Office 456-3600 • on-site waste disposal system, Environmental Health District 456-6040 • construction in a flood plain, County Engineer's Office 456-3600 • electrical wiring, State Department of Labor and Industries 456-2792 • sewer connection', County or City Utilities Department 456-3604 EXPIRATION Unless otherwise noted, this permit will be considered null and void by limitation of the work authorized by the permit is not commenced or is stopped for a period of 180 days, unless a written request for an extension of the permit is received and approved by the Building Official prior to expiration.At a minimum an inspection should be requested at least once every 180 days to assure the validity of the permit. A permit may be renewed within one year of the date of expiration for one-half the original fee, subject to certain limitations— please call us if you have any questions, MISTAKES? If you think we've made an error in processing this permit or in conducting inspections pertaining to it, or find erroneous information in the permit,please bring it to our attention immediately by filing a written request for correction within-10 working days of discovery. All such requests should be directed to the Department of Buildings at the address found on the face of this permit. N it I 4 r i . E . 8620 44th Spokane, Iiia . 99206 THESE PLANS HAVE BEEN ROFVIEWEO - '4 ' �) ,s'�°o�' yY5.-r-- Phone 509 926-6217 Fax 509 928-8689 ON / - 2`1 - Z. Legend for Radon mitigation system - perforated pipe beneath slab Q solid I'ABS stack vent pipe RADON SYSTEM SPECIFICATIONS All , �- � z - 5 ( 7 Radon Vent a ` RADON MITIGATION SYSTEM 1 This radon mitigation system Is .% 1 I i designed only for the spoon() Job- '_ i site address designated . The system basement i is not guaranteed unless Installed / by Cavalier Corporation r • Job site address: E 5421 18t h , builder Baker Builders. c° , i- �) ... garage • Sq Ft <1800 „ 'v; ; ".Fu`t3 '-etitenty E 5421 18th 1Joi4c. ' 1:1''.: 6102e: i' ; 1 `. , War r : n - , v'• • . ' Date ..� East of Carnahan Hill �` '"`•" a •' Environmental Protect iorf� ►tl ` if!�#10044 lo_Ut�Lit tpsHE1\1 __ 1 a EAST 1802 TRENT • SPOKANE, WA 99202 • (509) 534-4500 rNc lso� 134-4M3 • STATE COMTPACTLI. MMUS, I lwr• IO,M • A Widow of oho ban Comp, la • • _5TA.1.1 LE4__L! [ 1.E (0 FT. -R-0.W) _ADDRESS: LEGAL.: # PARGFL L0•t"+hr.>;A; SCALE T5-- 13 L135: St -I- 3)1CK 59- /8 Tti AVE. SPOgfN L 0'r'DEVON RI0 G_a Pot -tor o r tRkGT . of $ P. 85-37 s 10,25$ In= 201-011 ( • '�s QJ,uja1ier engineering radon services • E. 8620 44th a Spokane, WA 99206 Phone (509) 926-6217 FAX (509) 928-8689 RADON SYSTEM SPECIFICATIONS, SPOKANE COUNTY: i . Perforated pipe shall be installed within the native soil or fill (sand, gravel or soil ) at a minimum depth of 1" below the intended slab. 2 . The pipe shall be a minimum diameter of 4" . meet AASHTO M252 , have perforations no wider than 1/16" and have a minimum of 2.5 square inches of total perforations per linear foot of pipe. 3 . There shall be a minimum of 10 linear feet of perforated pipe per hundred square feet of slab floor space. 4 . The pipe shall be laid in a continuous loop. connected at both ends to the solid stack vent pipe. 5. Any slab area, which is larger than 10 square feet , which is isolated from other slab areas by footings or other barriers, shall have a perforated pipe installed to the above specifications. (The pipe can be a single length rather than a connected loop if the area is too small or narrow to accomodate a connected loop. ) 6 . A stack vent of ABS , schedule 40, minimum size 4" , shall l be connected to the sub-slab pipingproceed to an exit location on the roof , and extending 14" above the roof . The pipe shall be labeled "radon vent" every 16" or less for its full length. The pipe ' s attic location shall allow a minimum of 4 ' of head room. When- ever possible this exit location shall be on the backside of the roof . 7 . Any elbows in the stack vent piping shall have a centerline radius minimum of 1 . 5 by pipe width. 8. An inline centrifugal fan, minimum 114 cfm (@ 3/8" W.C. + UL listed, manufactured specifically for radon mitigation, maximum sone level 2.8, shall be installed in the exhaust line, in the attic. 9. Couplings to connect the vent piping to the fan shall be elastomeric PVC, Fernco series 1056 or equal . 10. The fan shall be hard-wired and the breaker labeled " radon fan" . 11 . All penetrations and joints in the concrete floor slab below grade shall be sealed with caulk or grout . 12. A notice shall be permanently attached to the electrical panel advising the owner or occupant about the radon system and that he/she shall test the home for radon annually. The notice shall include Cavalier ' s name and . phone number . 13. All craftsmanship shall be of high quality .