1993, 02-18 WA State Energy Code Compliance 3 � � • WATTSUN 5 .3 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 02/18/93- 4 FILE : C : \WATTDATA\LD1309 .WS HOUSE ID: LD1309 Site: DAKOTA Analyst : TAS ( MARQUESS ) SPOKANE , WA jurisdiction: SPOKANE. COUNTY ( ) -- Utility: WWP orneowner : House Type: Single Family Floor Area : 2668 ft2 Builder : LANCE DOUGLAS Weather Data: Spokane , WA Climate Zone : 2 ( 509 )483-6532 The PROPOSED design *COMPLIES* with 1991 WA State Energy Code . REFERENCE PROPOSED COMPONENT PERFORMANCE 526 516 Btu/hr-F ENERGY BUDGET 9 .75 9 .93 kWh/ft2-yr r r REFERENCE DESIGN Reference Component. Value X Area = UA BG Wall 3 .5 ' U-0 .041 308 12 .6 BG Slab 3 .5 ' F--0 .640 88ft 56 .3 8G Wall 7 ' U-0 .036 525 18 .9 BG Slab 7 ' F-0 .554 75ft 41 Floor U--O .029 56 1 .6 Glazing ((15' U--0 .600 400 .2 240 . 1 Doors U--0 .40(. 40 .() 16 .0 AG Wall U-0 .062 1540 95 .5 Ceiling , Attic U-0 .031 983 30 .5 Ceiling , Vault U--0 .034 370 12 .6 Infiltration ACH-0 .350 16437ft3( 99 .5 ) Reference UA 526 PROPOSED DESIGN COMPONENTS Component Desor ipt i.en Valuc X Area - UA BG Wall RO Uni nsu lated 3 .5 ' depth U-0 .271 308 83 .5 BG 3 .5BG Slab F-0 .511 88ft 45 .0 Items in parentheses not included i n COMPONENT PERFORMANCE. totals . ** Denotes non-standard values •-- check calculation of thermal value . --.. WATTSl_!N 5 .3 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 02/18/93 FILE : C : \WATTDATA\LD1309 .WS HOUSE ID: LD1309 BG Wall RO Uninsulated 7 ' depth U-0 . 185 525 97 .1 t3G Slab F-0 .434 75ft 32 .5 Floor R30 vented Joist 16oc U-0 .029 56 1 .6 Glazing C9% **2 glaze vinyl 3/4 " air space U-0 .480 181 .5 87 .1 **2 g.lz .vinyl 3/4 "air space sld 'g dr . U-0 .520 35 .0 18 .2 **2glaze mtl . i nsu.l w/full light U-0 .320 19 .0 6 .1 Doors **Metal Insul , w/ Raised Panel U-0 .220 21 .0 4 .6 Metal R-5 base case U-0 .190 19 .0 3 .6 AG Wall R19 ADV Lap Wood U-0 .055 1705 93 .8 Ceiling R38 blown Attic STD baffled U-0 .031 983 30 .5 R30 batt Vault vented 2x12 24oc U-0 .033 370 12 .2 Infiltration Standard Air Sealing ACH-0 .350 16437ft3 ( 99 .5 ) Proposed UA 516 Struc: Mass Light Frame , Sheetrock walls M- 3 .000 1353 4059 **Slab w/ no cover M-10 .000 1315 13150 HEATING/COOLING/VENTILATING SYSTEMS PROPOSED Heating System Type : Gas Furnace Make: unknown/ Model : unknown/ System Efficiency : 80 % Modified Efficiency : 76 % Design ACH: 0 .60 Heating Load( at 66F dt. ) : 46414 Btu/hr System Size : 46 .4 kBtu/hr Maximum Size 1150% : 69 .6 kBtu/hr Average Annual Heat : 118 MBt.0 Annual Cost : $ 658 ventilation System: integrated w/Forced A i r Furnace Cooling System: SEER: 0 .0 ( Unducted ) Cooling Load( at. 12F cit ) : 16844 Btu/hr Recommended Size @125%: 1 .9 tons Annual cool requirement : *** kWh/yr Solar Access: Partially Shaded Page 2 • s. WATTSUN 5 .3 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 02/18/93 FILE: C :\WATTDATA\LD1309 .WS HOUSE ID: LD1309 PROPOSED DUCT SYSTEM Location Avg Rva.lue Surface Area SUPPLY All in heated space RETURN All in heated space GLAZING ORIENTATION PROPOSED PROPOSED South 102 .2ft2 North : 113 .3ft2 Southeast : Northwest : East20 .0 West Northeast. : Southwest : Economic and energy consumption estimates are designed for comparative purposes only . Actual cost for heating will vary depending on weather conditions , occupant lifestyle and other factors . ------------- -- ---- Page 3 ----- - WATTSUN 5 .3 COMPONENT CHECKLIST 02/18/93 FILE : C : \WATTDATA\LD1309 .WS HOUSE ID: LD1309 Name : Floor Area : 2668 ft2 Address : DAKOTA Heating Type: Gas Furnace Reference : 1991 WA State Energy Code =OUNDATION INSPECTION Sub-slab radon requirement : f J Where required , slab is poured over a 4 " thick coarse gravel base . A 6-mil poly soil gas retarder membrane is installed between the gravel and slab . All tears , seams , and .joints in membrane are sealed . A radon vent pipe of at least 3" in diameter runs from each separate ,gravel area to 12" above eaves . Below grade walls : ( RO Uninsulated depth 308 .0 ft2 ) ( RO Uninsulated 7 ' depth 525 .0 ft2 ) Insulation is inst]led from the top of the below grade wall to the bottom ot. the footing . Any insulation above grade is protected from exposure . Slab Sealing : All penetrations , cracks and joints in concrete slab or walls are sealed with a urethane type sealant to limit the movement of soil gases into the indoor air . =RAMING INSPECTION Approved plans : Are available onsite Air leakage : Top and bottom of mudsill and soleplate are caulked/sealed . Rim joists between stories are caulked/sealed . All holes in building envelope ( i .e . exterior ceilings , walls , and floors ) are caulked/ led , including all electrical , plumbing , and HVAC penetrations . Outlets , switch boxes and recessed fixtures on exterior walls are caulked/sealed with approved sealant , or have foam face gaskets installed . Any recessed lights are IC rated , air tight , and sealed to the ceiling sheetrock . Wall framing: Net wall area : 1705 ft2 Advanced framing with studs spaced 24" o .c . , k- 10 insulated headers and no isolated cavities which cannot be insulated . Structural panels: All structural sheathing is stamped "Exposure I " or "Exterior " . Page 1 -- WATTSUN 5 .3 COMPONENT CHECKLIST 02/18/93 FILE: C : \WATTDATA\LD1309 .WS HOUSE ID: LD1309 Windows: ( 2 glaze vinyl 3./4" air space 181 .5 ft2 ) ( 2 glz .vinyl 3/4- air space •.Ld 'g dr . 35 .0 ft2 ) ( 2glaze mt l. . insul w/full. 1.ight 19 .0 ft2 ) Windows are installed as shown on the approved plans . The rough opening around windows and doors is caulked/sealed . Exhaust fans , spot ventilation: Bathroom fans are 50 CFM , kitchen fans are 100 CFM . Fan ducting has minimal bends and terminates outside of the building . The whole house exhaust fan is between: 100 .0 and 140 .0 C:FM . INSULATION INSPECTION Wall insulation : ( R19 ADV Lap Wood 1705 .0 ft2 ) Insulation fills all exterior wall cavities . It is not compressed and is cut to fit around wires , pipes , and outlet boxes . Recessed fixtures in exterior walls have at least L:._ 5 insulation behind them . Vaulted ceiling : ( R30 batt. Vault vented 2x1/ 24oc 370 .0 ft2 ) Insulation is installed to the manufacturer 's recommended density and coverage without compression . Vapor retarder : 1 .0 perm or less vapor retarder ( e .g . poly , kraft paper , perm rated paint ) is installed on the warm side of insulation in floors , ceilings and walls . A 0 .5 perm vapor barrier is installed on all vaulted ceilings . Recessed lights : Any recessed light fixtures in the thermal envelope are certified under ASTM E-283 and labeled showing compliance , or are sealed around the exterior to be air tight . FINAL INSPECTION Crawl space moi sture barrier : A six mu , black po.lyethelene ground cover is installed on crawl:= pac'e tloo'r F1.00r Insulation : ( R30 0 vent..:d ;Joie>t. 16oc 56 .0 ft2..) Insulation is supported in a permanent manner without compression . Crawlspace ventilation: • At. least 0 .2 Ft2 of net free ventilation is provided in the vented crawispace . -" ---- Page 2 WATTSUN 5 .3 COMPONENT CHECKLIST 02/18/93 FILE : C : \WATTDATA\LD1309 .WS HOUSE ID: LD1309 Pipe .insulation : All water pipes in unheated spaces are insulated to ,t--' Hot water : Electric water heater labeled as meeting ASHRAE Standard 90A--1980 or 1987 NAECA . Tank has R---10 non-compressible pad underneath if located over slab or in unconditioned space . Shower heads allow a maximum flow rate of 3 .0 gallons per minute . Doors: (Metal. Insul , w/ Raised Panel 21 .0 ft2 ) ( Metal R-5 base case 19 .0 ft2 ) Weatherstripping , t.hreshhold , and doorsweep are properly adjusted and seal well . Ceiling: ( R38 blown Attic STD baffled 983 .0 ft2 ) insulation is installed to the manufacturer 's recommended density and coverage . Attic access doors are insulated and weat.herstr ipped . Heating system: unknown/ unknown The heating system does not exceed: 69647 BTUs . Ventilation: The ventilation system has been checked for proper operation . If designed for intermittent operation , the system is controlled automatically by a time-of-day timer set to run for a minumum of eight hours per day . If designed for continuous operation , the system is directly wired to a dedicated circuit in the electrical panel . Make-up air : A duct provides fresh air directly into the return air plenum of the central forced air heating system . The duct is .insulated to R4 if it runs through heated space . A motor-operated damper ,, located within 36 inches of the air handler , prevents air from entering the plenum when ventilation is not called for . A clock timer operates the designated whole-house exhaust •fan., turns on the HVAC air handler , and opens the mechanical fresh air duct damper whenever ventilation is needed . Make-up air : The outdoor intake duct is equipped with a damper that limits flow to 140 .0 CFM under normal operating conditions . Fireplace/Woodstove: Combustion air is ducted directly into the firebox . Duct has a cross sectional area of at least 6 square inches and a readily :_ ---- -- - Page 3 WATTSUN 5 .3 COMPONENTCHECKLIST 02/18/93 FILE : C : \WATTDATA\LD1309 .WS HOUSE ID : LD1309 accessible operable damper . Doors are installed and fit tightly . All gas or oil combustion appliances ( except stoves and clothes dryer ) have outside combustion air ducted directly to the appliance . All stoves have an exhaust fan directly over them . Combustion Exhaust : Al ].. combustion exhausts are separated by minimum 3 ' vertically <:1 10 ' horizontally . Radon monitor : Radon monitor supplied to residents . Exhaust duct insulation : All xhaust ducts in unheated spaces are insulated to R4 . Page 4 --