1995, 05-16 Super Good Cents Compliance Report . 4 r WATTSUN 5.5 LONG TERM SUPER GOOD CENTS/1991 MCS COMPLIANCE REPORT 05/16/95 FILE: A:5-15.WS HOUSE ID: JC#601 Iw Site: 14506 E. 23RD Analyst: MICHAEL DeVLEMING VERADALE, WA 99037 Jurisdiction: SPOKANE COUNTY (509)990-4946 Utility: VERA WATER & POWER Homeowner: House Type: Single Family Floor Area: 3083 ft2 (509) Builder: Weather Data: Spokane, WA 5426 N. VISTA GRANDE DR Climate Zone: 2 (509)922-6428 The PROPOSED design QUALIFIES for SGC(91 MCS) Tier 1. REFERENCE PROPOSED COMPONENT PERFORMANCE 446 441 Btu/hr-F ENERGY BUDGET 3 .76 3 .75 kWh/ft2-yr REFERENCE DESIGN Reference Component Description Value X Area = UA BG Wall 7' R21 batt 7' w/TB U-0 .035 1239 43 . 4 BG Slab 7' F-0 . 503 177ft 89.0 Floor R30 vented joist U-0. 029 23 0.7 Glazing @15% 0. 35 U-value U-0. 350 462 .5 161 .9 Doors Metal R5 base case U-0 . 190 38 . 0 7. 2 AG Wall R21+R5 ADV U-0 .041 916 37.5 Ceiling, Attic R49 blown Attic ADV U-0. 020 1563 31 . 3 Infiltration Standard air sealing ACH-0 . 350 12424ft3 75. 2 Reference UA 446 PROPOSED DESIGN COMPONENTS Component Description Value X Area = UA Items in parentheses not included in COMPONENT PERFORMANCE totals. * Denotes adjusted UA to reflect 7-1/2 mph wind speed. Page 1 WATTSUN 5.5 LONG TERM SUPER GOOD CENTS/1991 MCS COMPLIANCE REPORT 05/16/95 FILE: A: 5-15.WS HOUSE ID: JC#601 BG Wall R21 Batt 7' depth U-0.034 1239 42 . 1 BG Slab F-0. 557 177ft 98. 6 Floor R30 vented Joist 16oc U-0 .029 23 0.7 Glazing @9% 2g1 Casement w/NFRC Label U-0 . 380 40 .0 14 .8* 2g1 Casement w/NFRC Label U-0. 360 248 .0 86.8* Doors 2g1 Half Lite Wood 1/4" Clr U-0.420 20. 0 8.0* Metal 1 3/4" , urethane flush +tb f ! U-0. 140 18. 0 2 . 5* AG Wall R21 ADV Lap Wood U-0 .051 305 15. 6 R21 ADV T1-11 U-0.053 785 41 .6 Ceiling R38 blown Attic STD baffled U-0.031 803 24 .9 R38 blown Scissor 4 : 12 STD baffled U-0. 040 760 30.4 Infiltration Standard Air Sealing ACH-0. 350 12424ft3 75.2 Proposed UA 441 Struc Mass Light Frame, Sheetrock walls M- 3 .000 1553 4659 Slab w/No cover, Sheetrock walls M-10. 000 1530 15300 HEATING/COOLING/VENTILATING SYSTEMS PROPOSED Heating System Type: Heat Pump: Air Source Make: HP Air Source Default System Efficiency: 6. 8 HSPF Backup AFUE: 100.0% (Electric) Modified Efficiency: 171 % Design ACH: 0.60 Design Load(at 66F dt) : 33516 Btu/hr Duct Losses(% Dsn Load) : 0 Btu/hr( 0%) Total Load: 33516 Btu/hr System Size(Output) : 50500 Btu/hr ( 150%) Outdoor Unit Size: 2 . 5 Tons (@47F) Auxiliary Size: 10 . 3 kW ( 150%) HP Balance Point: 27 F Average Annual Heat: 8260 kWh Annual Cost: $ 450 Ventilation System: Integrated Spot & Whole House Cooling System: SEER: 0.0 ( ) Cooling Load(at 12F dt) : Btu/hr System Size(%Over) : tons(@125%) Annual Cool Requirement: kWh/yr Solar Access: Partially Shaded Page 2 • 4 ( WATTSUN 5. 5 LONG TERM SUPER GOOD CENTS/1991 MCS COMPLIANCE REPORT 05/16/95 FILE: A: 5-15.WS HOUSE ID: JC#601 PROPOSED DUCT SYSTEM Location Avg Rvalue Surface Area SUPPLY All in heated space RETURN All in heated space GLAZING ORIENTATION PROPOSED PROPOSED South 206.Oft2 North 58.0ft2 Southeast : Northwest : East • West 24.0 Northeast : Southwest : Eff S Glz: 3 .7% Economic and energy consumption estimates are designed for comparative purposes only. Actual cost for heating will vary depending on weather conditions, occupant lifestyle and other factors. Page 3 . . T601 N.Evergreen Road PO.Box 630 Veradale,WA 99037-0630 (509)924-3800 WATER&POWER May 16, 1995 Randy Vissia Department of Buildings 1026 West Broadway Spokane, WA 99260 Dear Randy: The dwelling structure at (14506 East 23rd) listed on the attached information packet has been reviewed by the undersigned and meets the SUPER GOOD CENTS/WSEC qualification criteria for the Component Performance approach using the WATTSUN5.5 Computer Program. Sincerely, VERA WATER POWER L. V*C?1"--i'\ J Michael DeVleming, Energy Management Direct enclosure