Loading...
2006, 08-10 Permit App: 06003089 Addition, Remodel Project Number: 06003089 Inv: 1 , Application Date: 8/10/2006 Page 1 of 3 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Project Information: Permit Use: SINGLE STORY ADDITION&REMODEL Contact: R&D DEVELOPMENT&CONST. Address: 1818 W FRANCIS AVE,STE 180 C-S-Z: SPOKANE,WA 99205 Setbacks:Front Left: Right: Rear: Phone: (509)218-7565 Group Name: Site Information: Project Name: Plat Key: Name: VERA CREST SUB District: East Parcel Number: 45261.2208 Block: Lot: SiteAddress: 14924 E 23RD AVE Owner:Name: HANEKE,W H&C L Address: 14924 E 23RD AVE Location::CSV VERADALE,WA 99037-9335 Zoning: UR-3.5 Urban Residential 3.5 Water District: Hold: [I] Area: .00 Acres Width: 0 Depth: 0 Right Of Way(ft): 0 Nbr of Bldgs: 0 Nbr of Dwellings: 0 Review In formation: ., Review Building Plan Review Released By: Originally Released: 8/9/2006 By: TMELBOU Driveway/Approach Released By: Originally Released: 8/10/2006 By: amblake Landuse/Zoning/HE Conditions Released By: Originally Released: 8/7/2006 By: MBASINGE Sewer Review Released By; PER UTILITIES Originally Released: 8/10/2006 By: amblake Operator: AMB Printed By: AMB Print Date: 8/10/2006 Project Number: 06003089 Inv: 1 Application Date: 8/7/2006 Page 1 of 2 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Project Information: Permit Use: SINGLE STORY ADDITION&REMODEL Contact: R&D DEVELOPMENT&CONST. Address: 1818 W FRANCIS AVE,STE 180 C-S-Z: SPOKANE,WA 99205 Setbacks:Front Left: Right: Rear: Phone: (509)218-7565 Group Name: Project Name: Site Information: Plat Key: Name: VERA CREST SUB District: East Parcel Number: 45261.2208 Block: Lot: SiteAddress: 14924 E 23RD AVE Owner:Name: HANEKE,W H&C L Address: 14924 E 23RD AVE Location::CSV VERADALE,WA 99037-9335 Zoning: UR-3.5 Urban Residential 3.5 Water District: Hold: ❑ Area: .00 Acres Width: 0 Depth: 0 Right Of Way(ft): 0 Nbr of Bldgs: 0 Nbr of Dwellings: 0 Review Information: . .ta, . � _�_ r -,_ „ Review Building Plan ReviewReleased By: Th[ t co Driveway/Approach Released By: Landuse/Zoning/HE Conditions I Released'By: 144L f Sewer Review Released By: Permits: , Operator: AMB Printed By: AMB Print Date: 8/7/2006 Project Number: 06003089 Inv: 1 , Application Date: 8/10/2006 Page 2 of 3 • THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Permits: .wmm ._ Building Permit Contractor: R&D DEVELOPMENT&CONST. Firm: R&D DEVELOPMENT&CONST Address: 1818 W FRANCIS,STE 180 Phone: (509)218-7565 SPOKANE,WA 99205 This Application: Total Project: Description Grp Type Notes Sq Ft Valuation Sq Ft Valuation 1&2 FAMILY R-3 VB 1,426 $123,163.62 1,426 $123,163.62 BASEMENT F R-3 VB 100 $2,000.00 100 $2,000.00 BASEMENT U R-3 VB 1,066 $15,990.00 1,066 $15,990.00 Totals: 2,592 $141,153.62 2,592 $141,153.62 Item Description Units Unit Desc Fee Amount RESIDENTIAL PERMIT FEE 1 SELECT $1,228.95 WSBC SURCHARGE 1 SELECT $4.50 SF PLNS RVW<7999 SQ FT 1 SELECT $491.58 Permit Total Fees: $1,725.03 Plumbing Permit Contractor: R&D DEVELOPMENT&CONST. Firm: R&D DEVELOPMENT&CONST Address: 1818 W FRANCIS,STE 180 Phone: (509)218-7565 SPOKANE,WA 99205 Item Description Units Unit Desc Fee Amount TOILETS/BIDETS 3 NUMBER OF $18.00 SINKS 6 NUMBER OF $36.00 SHOWERS 1 NUMBER OF $6.00 TUBS 1 NUMBER OF $6.00 DISH WASHERS 1 NUMBER OF $6.00 GARBAGE DISPOSAL 1 NUMBER OF $6.00 CLOTHES WASHER 1 NUMBER OF $6.00 Permit Total Fees: $84.00 Operator: AMB Printed By: AMB Print Date: 8/10/2006 Project Number: 06003089 Inv: 1 Application Date: 8/10/2006 Page 3 of 3 • THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit All driveway approaches to be constructed per Spokane County Standards as adopted by the City of Spokane Valley. Minimum of 7.5' from each property line,5' from crosswalks or intersection curb and minimum of 15' of separation between any two approaches. Flat portion of a residential approach to be minimum of 16' wide,maximum of 30'wide and combined approach width not to exceed 50%of total frontage. (A)LITHE BULDING OFFICIAL IS AUTHORIZED TO REQUIRE THE PERMIT APPLICANT TO PROVIDE FEE REIMBURSEMENT TO THE CITY OF SPOKANE VALLEY FOR ANY PROFESSIONAL SERVICES REQUIRED OUTSIDE OF CITY STAFF REVIEW. (B)❑SOME EXAMPLES OF POTENTIAL OUTSIDE RESOURCES INCLUDE PLAN REVIEW, CONSTRUCTION INSPECTION AND SURVEYING. Payment Summary• Permit Type Fee Amount Invoice Amount Amount Paid Amount Owing Building Permit $1,725.03 $1,725.03 $0.00 $1,725.03 Plumbing Permit $84.00 $84.00 $0.00 $84.00 $1,809.03 $1,809.03 $0.00 $1,809.03 Disclaimer: Submittal of this application certifies the owner(or person(s)authorized by the owner)has both examined and finds the information contained within to be true and correct,and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for,or an approval of,any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: AMB Printed By: AMB Print Date: 8/10/2006 Permit Center0. I a 1' �‘`i� (` Spolkane • 11707 E Sprague Ave, Suite 1� ' j }ERMIT NUMBER:VIOL "(j Spokane Valley,WA 99206 �.� � , � 0- PERMIT FEE: ......Valley (509)688-0036 FAX: (509)688.-0Q37 A� 0 2006 Community Development www.spokanevalley.on4 i ;_) Ir=)? uj 11 �i IAA !� ig Residential Construction New Construction n Accessory Bldg Permit Application 15ZI Addition/Remodel Deck Other: SITE ADDRESS I'-19;.4 EAs, A-3 ASSESSORS PARCEL NO: 115261 ,o2Zog LEGAL DESCRIPTION: \"ERA e_9. -1-- Sob LB B1 Building Owner: wpt►--,r RiS ttk Contractor: 'FipM r c 6746......a,x2riexi Name: Name: -iv30R'rcr .,/ Address: 19%1 C a3„2.. Address: 1g%S 0 4"'aplis; 1E0 City: VALE State: tjk Zip:99,1)3 7 City: S,?pK AAS State: tj A Zip:en 205 Phone: 9. ' ti,S 6 Fax: Phone: ..,z`g,-.7.5�5 Fax: 501_403_04 i), Contractor Lic No:RDDEvcfsl xp Date: 5/3 i to .7 Contact Person / City Business Lic.No: 44�(5 Name: - . . . ..y- i 1,. _1 _ t� t >L Phone: '- -1.2--i C -- Z P) '7 S t)S Describe the scope of work in detail: Cost of Project: $ 31 y,vrc' 31t.i6� r -i /5\vb1 r c l R:. ?-z4'be- **************The following MUST be complete: (write N/A if not applicable)********************** HEIGHT TO PEAK: DIMENSIONS: #OF STORIES: TOTAL HABITABLE SPACE: MAIN FLOORTO SQ 2"U FLOOR SQ. FTG: UNFIN BASEMENT SQ. FTG: IMPERVIOUS"SURFACE FTG: iSF6 4bv"r.mr io4G 7`AiktAt! 'fes A1/ _eco 0 FINISHED BASEMENT o'er-GARAGE SQ. FTG: DECK/COV. PATIO SQ. FTG: 30% SLOPES ON SQ. FTG: ,f iCoSc#: JamItti 525 PROPERTY: #OF BEDROOMS: CONSTRUCTION TYPE: HEAT SOURCE: SEWER OR SEPTIC? B r �vMkc c)�� The permitee verifies,acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling,the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal,state or local laws, codes or ordinances.6) Plans or additional information may be required to be submitted,and subsequently approved before this application can be processed. Signature c Date 448 7,„. 276, Method of Payment: ❑ Cash fp Check ❑ Mastercard ❑ VISA Bankcard#: Expires: VIN#: Authorized Signature: REVISED 8/25/2005 Spuno(wkane .0001;Valley 11707 E Sprague Ave Suite 106 • Spokane Valley WA 99206 509.921.1000 ♦ Fax: 509.921.1008 ♦ cityhall@spokanevalley.org Residential Plan Submittal Minimums ❑ Completed Building & Mechanical application with: Accurate address, Parcel Number and/or Legal Description, description of work, owner and contractor information, signature, and date. ❑ Two sets of plans including Site Plan, elevations, floor plans, foundation plans With details, roof plan, framing plans & details. ❑ Show the height of any proposed buildings or accessory structures. ❑ Floor plan for each floor: Dimension to scale (minimum 1/8") and label each Room (including sq. footage of house and garage on plans) Show each level of existing house and square footage of any additions. ❑ All braced wall panel types: show locations and details of installation, including engineered design. ❑ Egress windows: Provide at least one window or exterior door approved for Emergency escape or rescue from a basement and in every room for sleeping. ❑ Smoke detector locations ❑ 22" X 30" attic access location ❑ 18" X 24" crawl space.access: ❑ One-hour separation detail: between house and garage ❑ Floor framing details: Joist type, size, spacing and installation details ❑ Roof framing plan and details ❑ Furnace and hot water heater location. ❑ All header locations: type, size, and connections ❑ Foundation plan ❑ Insulation information Permit Center SpokaneOS.IN11707 E Sprague Ave,Suite 106 PERMIT NUMBER: sValley , Spokane Valley,WA 99206 �/� (509)688-0036 FAX:(509)688-0037 Community Development www.spokanevallev.ore PERMIT FEE: Plumbing Permit Application n Commercial C. Residential SITE ADDRESS: Building Owner WA.�,r e def/ �+s 4\A i Name: ..%v1,1 c 1(....e: � Phone: 4 Ci se Fax: Address: 0i 9 zy E > -. City: itL?) -c, State: C..1& Zip: ¶ O7 Contractor C� Name: 1. I p � � L ��a-fv.Ei��'It"7�! * `at15[�.�rfc:/�hone: �� 1 ���-�ls��j Fax: ���"�L Address: ill `s IA r4AiNSc t S ..i .. i Q>C> City: mi,1E-- State: (AskZip: Q.epos License No: ?' cis -7 , V CityBusinessLic: �Or,'L( B1 C Contact `7 _ r-p In A L), �.\�,-1 S Name: �O —i- IA Phone: DESCRIPTION OF WORK #OF UNITS X COST = TOTAL AMOUNT 1 TOILETS WATER CLOSET,BIDETS GIV 3 X $6.00 = 2 URINALS X $6.00 = 3 TUBS I X $6.00 = 4 SHOWERS(PER TRAP) BATH,STALL,ON-SITE BUILT 1 X $6.00 = LAYS/BASINS,BAR,FLOOR,KITCHEN, 5 SINKS LAUNDRY,UTILITY,JANITOR,PHOTO, X $6.00 = X-RAY,FOOD,PREP/CULINARY MEAT (p 6 DISHWASHER @ X $6.00 = 7 CLOTHES WASHERa dX $6.00 = 8 GARBAGE DISPOSAL q X $6.00 = 9 WATER SOFTENER X $6.00 = 10 ELECTRIC HOT WATER TANK NOTE: IF GAS,SEE MECHANICAL X $6.00 = AREA,CASE,COIL,TRENCH, 11 FLOOR DRAINS CONDENSATE X $6.00 = 12 ROOF DRAINS/OVERFLOW DRAINS X $6.00 = 13 FOUNTAINS,DRINKING X $6.00 = WATER PIPING/DRAIN-IN WASTE, NSTALLATION,ALTERATION,REPAIR, 14 VENT,PLUMBING,REVERSAL REVERSALS X $6.00 = 15 SEWAGE EJECTOR GRINDER,SUMP PUMP X $6.00 = ICE AN/OR COFFEE MAKER,HOSE BIB, 16 WATER USING DEVICE STEAMER X $6.00 = PROOFER,CARBONATOR,SWAMP COOLER VACUUM BREAKER,CHECK VALVE, AND R.P.B.P.D.FOR: VATS,TANKS, 17 CROSS CONNECTION DEVICE BOILERS X $6.00 = GREASE TRAP,SAND TRAP, 18 INTERCEPTORS CHEMICAL HOLDING TANK X $6.00 = 19 MEDICAL GAS(per outlet) NITROUS,OXYGEN X $6.00 = 20 MISCELLANEOUS PLUMBING FIXTURE X $6.00 = 21 PRIVATE SEWAGE DISPOSAL/SYS X $20.00 = 22 INDUSTRIAL WASTE INTERCEPTOR X $15.00 = SUBTOTAL METHOD OF PAYMENT: PROCESSING FEE ❑CASH )ICHECK 0 VISA 0 MC EXPIRES: $35.00 Card# VIN: TOTAL PERMIT FEE DUE: 7 AUTHORIZED SIGNAT ,URFP .............. REVISED 8/26/05 Permit# Permit Date 0iREScheck Software Version 3.7.3 Compliance Certificate Project Title: Haneke Addition/Remodel Report Date:07/28/06 Data filename:1\Thehummer\00-projects\ARCHITECTURE PROJECTS\2006-048 Haneke Remodel\Haneke addition.rck Energy Code: 2003 IECC Location: Spokane,Washington Construction Type: Single Family Glazing Area Percentage: 10% Heating Degree Days: 6368 Construction Site: Owner/Agent: Designer/Contractor: 14924 East 23rd Walt and Chris Haneke Rob Henry Spokane Valley,WA 99037 R&D Construction 1818 West Francis Avenue,Suite 180 Spokane,WA 99205 Compliance: Passes Maximum UA:771 Your Home UA:652--> 15.4% Better Than Code(UA) Gross Cavity Cont. Glazing UA Assembly Area or R-Value R-Value or Door Perimeter U-Factor Ceiling 1:Flat Ceiling or Scissor Truss: 2943 38.0 0.0 88 Wall 1:Wood Frame,16"o.c.: 2376 19.0 0.0 125 Window 1:Vinyl Frame:Double Pane: 247 0.330 82 Door 1:Solid: 40 0.200 8 Basement Wall 1:Solid Concrete or Masonry: 1188 11.0 11.0 50 Basement Wall 2:Wood Frame: 594 11.0 0.0 50 Basement Wall 3:Solid Concrete or Masonry: 594 11.0 0.0 41 Floor 1:Slab-On-Grade:Heated:,Insulation Depth:3.0' 297 10.0 208 Furnace 1:Forced Hot Air:78 AFUE Air Conditioner 1:Electric Central Air: 13 SEER Compliance Statement:The proposed building design described here is consistent with the building plans,specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2003 IECC requirements in REScheck Version 3.7.3 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Builder/Designer Company Name Date Haneke Addition/Remodel Page 1 of 4 0 REScheckctioSoftware Version 3.7i.3 Date: Inspen Date:07/28/06 Ceilings: ❑ Ceiling 1:Flat Ceiling or Scissor Truss,R-38.0 cavity insulation Comments: Above-Grade Walls: ❑ Wall 1:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: Basement Walls: ❑ Basement Wall 1:Solid Concrete or Masonry,8.0'ht/4.0'bg/8.0'insul,R-11.0 cavity+R-11.0 continuous insulation Comments: Exterior insulation must have a rigid,opaque,weather-resistant protective covering that covers the exposed(above-grade) insulation and extends at least 6 in.below grade. ❑ Basement Wall 2:Wood Frame,4.0'ht/0.0'bg/4.0'insul,R-11.0 cavity insulation Comments: ❑ Basement Wall 3:Solid Concrete or Masonry,4.0'ht/4.0'bg/4.0'insul,R-11.0 cavity insulation Comments: Windows: U Window 1:Vinyl Frame:Double Pane,U-factor:0.330 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: Doors: ❑ Door 1:Solid,U-factor:0.200 Comments: Floors: ❑ Floor 1:Slab-On-Grade:Heated,3.0'insulation depth,R-10.0 continuous insulation Comments: Slab insulation to extend down from the top of the slab to at least 3.0 ft.OR down to at least the bottom of the slab then horizontally for a total distance of 3.0 ft. Exterior insulation must have a rigid,opaque,weather-resistant protective covering that covers the exposed(above-grade) insulation and extends at least 6 in.below grade. Heating and Cooling Equipment: ❑ Fumace 1:Forced Hot Air:78 AFUE or higher Make and Model Number: ❑ Air Conditioner 1:Electric Central Air:13 SEER or higher Make and Model Number: Air Leakage: ❑ Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. ❑ Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a 3"clearance from insulation. Haneke Addition/Remodel Page 2 of 4 Skylights: ❑ Minimum insulation requirement for skylight shafts equal to or greater than 12 inches is R-19. Vapor Retarder: U Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: ❑ Materials and equipment must be installed in accordance with the manufacturer's installation instructions. U Materials and equipment must be identified so that compliance can be determined. ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. U Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications. Duct Insulation: U Supply ducts in unconditioned attics or outside the building must be insulated to R-8. U Return ducts in unconditioned attics or outside the building must be insulated to R-4. U Supply ducts in unconditioned spaces must be insulated to R-8. U Return ducts in unconditioned spaces(except basements)must be insulated to R-2. U Where exterior walls are used as plenums,the wall must be insulated to R-8. U Insulation is not required on return ducts in basements. Duct Construction: U Duct connections to flanges of air distribution system equipment must be sealed and mechanically fastened. U All joints,seams,and connections must be securely fastened with welds,gaskets,mastics(adhesives), mastic-plus-embedded-fabric,or tapes.Tapes and mastics must be rated UL 181A or UL 181 B. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). U The HVAC system must provide a means for balancing air and water systems. Temperature Controls: U Thermostats are required for each separate HVAC system.A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: U Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. ❑ Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: U Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: U All heated swimming pools must have an on/off heater switch and require a cover unless over 20%of the heating energy is from non-depletable sources.Pool pumps require a time clock. Heating and Cooling Piping Insulation: ❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table 2. Haneke Addition/Remodel Page 3 of 4 Table 1:Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non-Circulating Runouts Circulating Mains and Runouts Heated Water Temperature(°F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2:Minimum Insulation Thickness for HVAC Pipes Insulation Thickness in Inches by Pipe Sizes Fluid Temp. Piping System Types Range(°F) 2"Runouts 1"and Less 1.25"to 2.0" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 106-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD:(Building Department Use Only) Haneke Addition/Remodel Page 4 of 4 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2 topic Index I Contact Info re to tit cit Search Laborarid Industries H , Safety Claims&insurance Workplace Rights Trades&Licensing Find a Law or Rule: ' Get a Form or Publication Look Up a Contractor, Electrician or Plumber Printer Friendly.Version General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry gal liability insurance. �.,... ...,� general .., License Information License RDDEVDD957KU Licensee Name R& D DEVELOPEMENT AND CONST Licensee Type CONSTRUCTION CONTRACTOR 602507693 Verify Workers Comp Premium. UBI Status Ind. Ins. Account Id Business Type PARTNERSHIP Address 1 1818 W FRANCIS AVE STE 180 Address 2 City SPOKANE County SPOKANE State WA Zip 99205 Phone 5092187565 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 5/31/2005 Expiration Date 5/31/2007 Suspend Date Separation Date Parent Company Previous License RDDEVDD957BD Next License Associated License https://fortress.wa.gov/lni/bbip/Detail.aspx?License=RDDEVDD957KU 8/7/2006 Look Up a Contractor, Electrician or Plumber License Detail Page 2 of 2 Business Owner Information Effective Expiration Name Role Date Date AUCLAIR, DONNA MARIE PARTNER 05/31/2005 f HENRY, ROBERT WILLIAM PARTNER 05/31/2005 Bond Information Bond Bond Company Account Effective Expiration Cancel Impaired Bond Received Bond Name Number Date Date Date Date Amount Date 1 OHIO CAS Until i #1 INS CO 3877791 05/31/2005 Cancelled $12,000.00 05/31/2005 Savings Information No Matching Information Insurance Information Company Policy Effective Expiration Cancel Impaired Received Insurance Name Number Date Date Date Date Amount Date AMERICAN STATES #2 INS CO 01CG708047 01/03/2006 01/03/2007 $300,000.00 11/28/2005." AMERICAN STATES #1 INS CO 01CG708047 01/03/2005 01/03/2006 $300,000.00 05/31/2005 =Summons/Complaints Information i No Matching Information Start a....New Search Printer Friendly Version r�. , About LBtI I Find a job at Lftl I Informacian en espanol Site Feedback uatioAl 1�, i_ 1-800-547-8367wan �,Washington State Dept.of Labor and Industries.Use of this site is subject to the taws of the = ` ' k,"�' state of Washington. Access Agreement I Privacy and security statement I Intended use/external content policy I Visit access.wa.gov Staff only link https://fortress.wa.gov/lni/bbip/Detail.aspx?License=RDDEVDD957KU 8/7/2006