Loading...
1991, 05-08 NW Energy Code Compliance Report VIATTSUN 5.1 1987 ' RTHWEST ENERGY CODE COMPLY 7CE REPORT 05/08/91 FILE: C:\WATTSUN5\KM#202 .WS (15V Ij.py_ (IT HOUSE ID: KM#202 Site: 23RD & TIMBERLINE Analyst: MICHAEL DeVLEMING : SPOKANE, WA 99216 Jurisdiction: SPOKANE COUNTY Utility: VERA WATER & POWER Homeowner: Mail: Floor Area: 2667 ft2 Builder: KEVIN MADDEN CONSTRUCTION Weather Data: Spokane, WA Address: 1214 SOUTH PROGRESS Climate Zone: 2 The PROPOSED design *COMPLIES* with 1987 Northwest Energy Code. REFERENCE PROPOSED COMPONENT PERFORMANCE 496 483 Btu/hr-F ENERGY BUDGET 5.46 3.17 kWh/ft2-yr REFERENCE DESIGN Reference Component Value X Area = UA BG Wall U-0.038 938 35.6 BG Slab F-0.430 184ft 79.1 Floor U-0.029 27 0. 8 Glazing @15% U-0. 390 400.0 156.0 Doors U-0.190 58. 0 11.0 AG Wall U-0.043 1150 49.4 Ceiling U-0.032 1432 45.8 Infiltration ACH-0. 350 17000ft3 102.9 Reference UA 496 PROPOSED DESIGN COMPONENTS Component Description Value X Area = UA BG Wall R19 batt 7' depth U-0.037 588 21.8 BG Slab F-0.570 84ft 47.9 R19 batt 3 .5' depth U-0.041 350 14.4 F-0.640 100ft 64. 0 Floor R30 vented Joist 16oc U-0.029 27 0. 8 Glazing @7% **2-GLAZE, VINYL FIXED U-0 .490 73 .1 34.4* **2-GLAZE, VINYL SLIDER U-0.480 124.5 57.3* Items in parentheses not included in COMPONENT PERFORMANCE totals. ** Denotes non-standard values - check calculation of thermal value. * Denotes adjusted UA to reflect 7-1/2 mph wind speed. Page 1 vgATTSUN 5.1 1987 ' RTHWEST ENERGY CODE COMPLY TCE REPORT 05/08/91 FILE: C:\WATTSUN5\KM#202.WS HOUSE ID: KM#202 Doors Metal R-5 base case U-0. 190 38.0 7.2* **Metal, glass insert U-0.400 20.0 7.8* AG Wall R19 INT Lap Wood U-0 .058 1352 78.4 Ceiling R38 blown Attic STD baffled U-0.031 661 20. 5 R30 batt Vault vented 2x12 24oc U-0.033 771 25.4 Infiltration Standard Air Sealing ACH-0.350 17000ft3 102.9 Proposed UA 483 Struc Mass Light Frame, Sheetrock walls M-3 .000 1347 4041.0 Slab w/carpet w/pad, Sheetrock wall M-5.000 1320 6600.0 HEATING/COOLING/VENTILATING SYSTEMS PROPOSED Heating System Type: Heat Pump: Air Source Make: HP Air Source Default Model: System Efficiency: 6 .8 HSPF Modified Efficiency: 175 % Heating Load(at 66F dt) : 37876 Btu/hr System Size: 29296 Btu/hr Maximum Size @150%: 16 .6 kW Auxiliary: 8.0 kW HP Balance Point: 27 F Average Annual Heat: 10975 kwh Annual Cost: $ 604 Ventilation Type: Non-Heat Recovery Option: Option 4 Cooling Load(at 12F dt) : 21067 Btu/hr Recommended Size @125% : 2.4 tons Solar Access: Partially Shaded PROPOSED DUCT SYSTEM Location Avg Rvalue Surface Area SUPPLY All in heated space RETURN All in heated space Page 2 REQUEST FOR INCENTIVE PAYMENT The file has been reviewed for project number qi - 14619 The building is a SINtG' F/ lL`l residential building located at 16718 . Z-3 YLD AYE. The necessary information is in the file and the permit holder has qualified to receive a builder incentive payment. The total area of conditioned floor area is 4 /A . The payment amount calculation is: FL 15 20 ?-9 The permit holder is I<EVINI MIN9D Th GONST Co. S, (Z Ig PRoGfzESS Ve t2APA•e _WA:• X03 r Tax I.D. No./ . 611 - 12 52061Z ***************************************************************** Request by Jt./0 nIASoAR-0D , staff, Spokane County Building and Safety. Please pay $ (SZD °° To: ((BVInl 1'),,AD® t.1 64J5T. Co . Check No. -if ) (a 111 , Date: t0 - a - q 2