Loading...
1991, 04-24 Permit App: 91002049 Residence SPOKANE COUNTY DEPARTMENT OF BUILDINGS W. 1303A1ROADWAY AVENUE SPOKANE,WASHINGTON 99260 (509)456-3675 I certify that I have examined this permit/application,state that the information contained in it and submitted by me or my agent to compile said permit/application is true and correct, and authorize Spokane County to proceed with processing. In addition, I have read and understand the INSPECTION REQUIREMENTS/NOTICE provisions included herein and agree to comply with same.All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not.I understand that the issuance of this permit/application and any subsequent inspection approvals or Certificates of Occupancy shall not be construed to give authority to violate or cancel the provisions of any state or local law regulating construction,oras a warranty of conformance with the provisions of any state or local laws regulating construction. SIGNATURE OF APPLICATION OWNER OR AGENT DATE • PROJECT NUMBER= 91002049 APPLICATION DATE= 04/24/9i PAGE 04 ** ** THIS IS NOT A PERMIT **** * PENALTIES WILL BE ASSESSED FOR COMMENCING WORK WITHOUT A PERMIT SITE STREET= 15910 E 23RD CT PARCEL4 • 25545-9059 ADDRESS-: VERADALE WA 99037 PERMIT USE= RESIDENCE PLAT: == 002248 PLAT NAME=== RIDGEMONT ESTATES Po L( 02 'c- BLOCK= 2 LOT= 12 ZONE= UR 3.5 DIST:== F AREA= 00000000 F/A== F WIDTH= 95 DEPTH-. 494 F:'/W= 50 0 OF BLDGS- i »: DWELLINGS= i WATER DIST =: VERA OWNER== HARLEY DOUGLAS INC. PHONE= 509 489 4260 STREET= 815 E ROSEWOOD AVE ADDRESS= SPOKANE WA 99208 CONTACT NAME= HARLEY DOUGLAS PHONE NUMBER= 509 489 4260 BUILDING SETBACKS : FRONT== 31 LEFT~ 15 RIGHT= 8 REAR= 50+ * ******** ******** :******** REVIEW INFORMATION *****x********n*** :******* DEPARTMENT REVIEW COMMENTS APPROVAL. COMMENTS BUILDING PLAN REVIEW REQUIRED Ted 4-1\- BUILDING SETBACK REVIEW REQUIRED ... .t C' fI ./6-g( CJti23� •74146710,e4 -4-2—'(4145-:iENGINEER APPROACH/FLOOD PLAIN/DRAINAGE S � *3* *******3 ***•*3**ac******* BUILDING PERMIT * * ** *• ** ****x** CONTRACTOR=== HARLEY C DOUGLASS INC PHONE= 509 489 4260 STREET= 845 E ROSEWOOD AVE ADDRESS.. SPOKANE WA 99208 NEW X REMODEL= ADDITION= CHANGE OF USE= DWELL UNITS= 1 OCCUP. L.Dv BLDG HGT-: 24 STORIES= BLDG W X t) = 27 X 56 SQ FT= 2000 SPRINKLER= N REQ PARKING= *HANDICAP= CRITICAL.. MAT= N DESCRIPTION GROUP TYPE SQ FT VALUATION BASEMENT U R-3 VN 4200 40800.00 GARAGE M-i VN 782 5470 .00 RESIDENCE R-$ VN 4200 52800.00 2ND FLOOR R-3 VN 600 43200.00 ITEM DESCRIPTION QUANTITY FEE AMOUNT RESIDENTIAL. VALUATION V 563.00 STATE SURCHARGE. `r' 4.50 COUNTY SURCHARGE V 90.08 **************** a * ****** * MECHANICAL PERMIT * ** * * *** ******+ n• CONTRACTOR= WAYNE SMITH HEATING PHONE= 509 328 4434 STREET= 102 E NORA AVE ADDRESS= SPOKANE WA 99207 ITEM DESCRIPTION QUANTITY FEE AMOUNT GAS WATER HEATER i 10.00 GAS HTG EQUIP< i 00, 000}BTU i 12.00 G A S PIPING 7 ?.,04`) ***** *****ate********* e * a * PLUMBING PERMIT ******** •*at• •************ ***** CONTRACTOR= GOLD SEAL. MECHANICAL.. INC PHONE= 509 535 5944 STREET=: 5524 E BONE AVE ADDRESS= SPOKANE WA 99212 ITEM DESCRIPTION QUANTITY FEE AMOUNT TOILETS 3 48.00 SINKS 3 18.00 SHOWERS 2 42.00 BATH TUBS 1 6.00 KITCHEN SINKS i 6.00 DISH WASHERS 1 6.00 ~ • ' . g9 ^ . NOTICE It is the responsibility of the permittee, not Spokane County, to see to it that the use described on the front of this permit complies with applicable codes and requirementsrequireden� that inspections are requested. Failure to request required and obtain the necessary approvals prior to progressing beyond the point where inspections '~yare npoo ionnrequired may necessitate removal of certain constructiono of �hn at the owne� t�pormi��eeexpense. ��tu minimum, the following inspections ARE REQUIRED by County Code: 1. FOOTING — when forms and reinforcement are in place and prior to placement of concrete. NOTE:This inspection includes review of the structure's setbacks from property lines.Minimum setbacks are established by County zoning regulations.Typically,side and rear yard setbacks are measured from property |i"eo, while setbacks for yards abutting streets are measured from the property line or the center line of the right-of-way.madwayright-of'wuy.whinhnverpmvidnathaq,eate,oetbooxf,omthecon»eriinoohhomadwmy Curb lines and fence lines are not necessarily indioah,00fproperty lines.|nsome moidenda|amus.the County can own as much as 20 feeof right-of-way between your property and the actual improved street/curbThe responsibility to comply with applicable setback provisions lies solely with the permittee— neither Spokane County nor its authorized representatives assume any responsibility for the verification or location of your property lines.Please verify their location prior to locatistructure. structure may require its relocation at the owner's/permittee's expense. 2. FOUNDATION—when forms and reinforcement are in place and prior to placement of concrete.(Blocking for a manufactured home is required to be inspected prior to the installation of skirting.) 3. FRAMING —after all framing, bracing and blocking is in place, and prior to concealing. 4. INSULATION — prior to the installation of drywall. 5, PLUMBING—after rough-in, before covering, and final. 6. MECHANICAL— rough-in of piping, before covering, metal chimneys before concealment, and final. 7. FINAL—when complete and prior to occupancy and/or use. Please provide 24 hours notice. NOTE:In addition to inspection of the structure,this inspection includes review of site improvements(typically UopiotedontheuppxwoUxh*p|an)requireVhyonUinan000,aaaoonUiuonofappnovo|ofthisponnitItems such anthe inotu|iauuno,hnrhydrants,fire department access,on-site dm [ inoge20nuwueu^).,nedim'— �vovem*n , pa,king.ond|ondocapingavvcommnnmquiromonmofapo,miVoitopmnw»ichmvutbouomp|otoU ,|p,tofino| appmva|ofabuilding o/ioov,unoeofnCo�i*vatenfOccupancy, - In addition to the above any plumbing or mechanical systems or materials which would be concealed by framingdrywall, concroto, etc., must be inspected prior to cover. Check with the department for "special inspections" in conjunction' with commercial projects. CALL FOR INSPECTIONS, TO INSURE PROMPT SERVICE, PLEASE GIVE 24 HOUR NOTICE. YOUR INSPECTOR IS UNDER CERTAIN C|RCUMGTANCES, PARTS OF YOUR PROJECT MAY REQUIRE INSPECTIONS FROM OTHER AGENCIES: • road cuts for utilities or drivesState or County Engineer's Office 456-3600 • on-site waste disposal system, Environmental Health District 456-6040 • construction in a flood plain, County Engineer's Office 456-3600 • electrical wiring, State Department of Labor and Industries 456-2792 • sewer connection, County or City Utilities Department 456-3604 EXPIRATION Unless otherwise noted, this permit will be considered null and void by limitation of the work authorized by the permit is not commenced or is stopped for a period of 180 days, unless a written request for an extension of the permit is received and approved by the Building Official prior to expiration.At a minimum an inspection should be requested at least once every 180 days to assure the validity of the permit. A permit may be renewed within one year of the date of expiration for one-half the original fee, subject to certain limitations—please call us if you have any questions. MISTAKES? If you think we've made an error in processing this permit or in conducting inspections pertaining to it, or find erroneousinformahoninthope,mitp|easoh,ingit*ooura�onhonimmediato|ybyh|ingawri�onmqum�foroo,moion within 10 working days of discovery.All such requests should be directed to the Department of Buildings at the address found on the face of this /i/9ri 'j e Dau9/95) Ave 14 0 G~x 1 8a b O (1� .0- ; i //1 ' I ' '''''1) / � e: (1° ' p a- .8, a-0, o <7, lino oi ,I1 N i-or /2-) 13/05 2 A,SierraoAiT 4:5T47 ES' • ���v� .ARD Ct p/ . 2 '': 20640 •w 11 04:41;i0Z---- . 1