Loading...
1992, 10-01 Super Good Cents Compliance Report C.OuMTX WATTSLN 5. 3 LONG TERM SUPER GOOD CENTS/1991 MCS COMPLIANCE REPORT 10/01/92 FILE: C: \WATTSUN5\KM#304.WS HOUSE ID: KM#304 Site: 1592$ EAST 23RD Analyst: MICHAEL DeVLEMING VERADALE, WA 99037 Jurisdiction: SPOKANE COUNTY ( ) - Utility: VERA WATER & POWER Homeowner: House Type: Single Family • Floor Area: 3374 ft2 ( ) Builder: KEVIN MADDEN CONSTRUCTION Weather Data: Spokane, WA Climate Zone: 2 ( ) - The PROPOSED desn QUALIFIES fo SGC(91 MCS) Tier 1. REFERENCE PROPOSED COMPONENT PERFORMANCE 477 472 Btu/hr-F ENERGY BUDGET 3.79 4.28 kWh/ft2-yr REFERENCE DESIGN Reference Component Description Value X Area = UA BG Wall 3 .5' R21 batt 3 . 5' w/TB U-0. 040 175 7.0 BG Slab 3.5' F-0.556 50ft 27.8 BG Wall 7' R21 batt 7' w/TB U-0. 035 840 29.4 BG Slab 7' F-0.503 120ft 60.4 Floor R30 vented joist U-0. 029 140 4.1 Glazing @15% 0.35 U-value U-0. 350 506. 1 177.1 Doors Metal R5 base case U-0.190 38.0 7.2 AG Wall R21+R5 ADV U-0.041 991 40.6 Ceiling, Attic R49 blown Attic ADV U-0. 020 1757 35. 1 Infiltration Standard air sealing ACH-0.350 14600ft3 88.4 Reference UA 477 PROPOSED DESIGN COMPONENTS Component Description Value X Area = UA BG Wall R19 Batt 7' depth U-0. 036 840 30.2 BG Slab F-0.554 120ft 66.5 Items in parentheses not included in COMPONENT PERFORMANCE totals. ** Denotes non-standard values - check calculation of thermal value. * Denotes adjusted UA to reflect 7-1/2 mph wind speed. Page 1 W$TTSUN 5.3 LONG TERM SUPER GOOD CENTS/1991 MCS COMPLIANCE REPORT 10/01/92 FILE: C: \WATTSUN5\KM#304.WS HOUSE ID: KM#304 BG Wall R19 Batt 3 .5' depth U-0.041 175 7.2 BG Slab F-0.625 50ft 31.3 Floor R30 vented Joist 16oc U-0. 029 140 4.1 Glazing @10% **2-GLAZE, VINYL FIXED W/ARGON-WP U-0. 380 52 . 0 19.2* **2-GLAZE, VINYL SLIDER W/ARGON-WP U-0.350 230.0 78.2* **2-GLAZE, PATIO SLIDER/ARGON-WP U-0.440 40.0 16.8* Doors Metal R-5 base case U-0. 190 38.0 7.2* AG Wall R19 INT Lap Wood U-0.058 1175 68.2 Ceiling R38 blown Attic STD baffled U-0. 031 1757 54.5 Infiltration Standard Air Sealing ACH-0.350 14600ft3 88.4 Proposed UA 472 Struc Mass Light Frame, Sheetrock walls M- 3.000 3374 10122 HEATING/COOLING/VENTILATING SYSTEMS PROPOSED Heating System Type: Heat Pump: Ground Source Make: Sol-A-Terra II Model: DE014VSA/ System Efficiency: 320 % Modified Efficiency: 192 % Design ACH: 0. 60 Heating Load(at 66F dt) : 36269 Btu/hr System Size: 16.2 kBtu/hr at 70F 12 .5 kBtu/hr at 50F Maximum Size @150%: 16.0 kW Auxiliary: 7. 0 kW Average Annual Heat: 9211 kWh Annual Cost: $ 350 Ventilation System: Integrated w/Forced Air Furnace Cooling System: SEER: 0.0 (Unducted) Cooling Load(at 12F dt) : 29323 Btu/hr Recommended Size @125%: 3 .4 tons Annual cool requirement: *** kWh/yr Solar Access: Partially Shaded Page 2 WATTSUN 5.3 LONG TERM SUPER GOOD CENTS/1991 MCS COMPLIANCE REPORT 10/01/92 FILE: C: \WATTSUN5\KM#304.WS HOUSE ID: KM#304 PROPOSED DUCT SYSTEM Location Avg Rvalue Surface Area SUPPLY All in heated space • RETURN All in heated space R- 8. 0 135.0 ft2 GLAZING ORIENTATION PROPOSED PROPOSED South ft2 •North ft2 Southeast : 106.0 Northwest : 110.0 East West Northeast : 106. 0 Southwest : Economic and energy consumption estimates are designed for comparative purposes only. Actual cost for heating will vary depending on weather conditions, occupant lifestyle and other factors. A vett^ HQ '.1,)4;0, (31 IVIRiREEN RD. 1-7\d'e P t )N 0 ;3 r;;4PA,I t4 4 c,,/^k I-,)1\1 Q9037-06310 October 1, 1992 Randy Vissia Department of Buildings 1303 West Broadway Ave. Spokane, WA 99260-0180 Dear Mr. Vissia: The dwelling structure (15920 East 23rd CT) listed on the attached information packet has been reviewed by the undersigned and meets the SUPER GOOD CENTS/WSEC qualification criteria for the Component Performance approach using the WATTSUN5 Computer Program. In order to meet the SUPER GOOD CENTS/WSEC specifications, all glazing will be required to be filled with Argon Gas. WSEC ventilation requirements will also need to be met. Sincerely, VERA Ati9WER ‘_. 1 i , IA Michael DeVleming, Director Energy Management Service enclosure cc Kevin Madden (Kevin Madden Construction)