Loading...
2008, 05-23 Permit App: 08001934 Addition Project Number: 08001934 Inv: 1 Application Date: 5/23/2008 Page 1 of 3 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Project Information: Permit Use: RESIDENTIAL ADDITION 8 X 10=BATH AND Contact: INTEGRITY REMODELING LAUNDRY AREA Address: P.O.BOX 8556 C-S-Z: SPOKANE,WA 99209 Setbacks:Front Left: Right: Rear: Phone: (509)455-4395 Group Name: Site Information: Project Name: Plat Key: 001705 Name: MOUNTAIN VIEW 04TH ADD District: Sout Parcel Number: 45271.3703 Block: Lot: SiteAddress: 13805 E 24TH AVE Owner:Name: MELCHISDECK,KEN Address: 13805 E 24TH AVE Location::CSV SPOKANE VALLEY,WA 99206 Zoning: R-2 SF Res Suburban District Water District: 010 VERA Hold: ❑ Area: .00 Acres Width: 80 Depth: 125 Right Of Way(ft): 0 Nbr of Bldgs: 1 Nbr of Dwellings: 1 Review Building Plan Review Originally Released: 5/23/2008 By: tmelbourn Landuse/Zoning/HE Conditions eleased l , - Originally Released: 5/23/2008 By: tschmidt Operator: jmm Printed By: jmm Print Date: 5/23/2008 Project Number: 08001934 Inv: 1 Application Date: 5/23/2008 Page 2 of 3 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Building Permit Contractor: INTEGRITY REMODELING Firm: TODD KUBICEK-INTEGRITY R Address: PO BOX 8556 Phone: (509)455-4395 SPOKANE,WA 99203 This Application: Total Project: Description Grp Type Notes Sq Ft Valuation Sq Ft Valuation RES ADD R-3 VB ADDITION 0 $16,000.00 0 $16,000.00 8 X 10 Totals: 0 $16,000.00 0 $16,000.00 Item Description Units Unit Desc Fee Amount RESIDENTIAL PERMIT FEE 1 SELECT $265.25 WSBC SURCHARGE 1 SELECT $4.50 SF PLNS RVW<7999 SQ FT 1 SELECT $106.10 Permit Total Fees: $375.85 Mechanical Permit Contractor: INTEGRITY REMODELING Firm: TODD KUBICEK-INTEGRITY R Address: PO BOX 8556 Phone: (509)455-4395 SPOKANE,WA 99203 Item Description Units Unit Desc Fee Amount VENTILATING FANS 2 NUMBER OF $20.00 CLOTHES DRYER 1 NUMBER OF $10.00 Permit Total Fees: $30.00 Plumbing Permit Contractor: INTEGRITY REMODELING Firm: TODD KUBICEK-INTEGRITY R Address: PO BOX 8556 Phone: (509)455-4395 SPOKANE,WA 99203 Item Description Units Unit Desc Fee Amount SINKS 2 NUMBER OF $12.00 SHOWERS 1 NUMBER OF $6.00 CLOTHES WASHER 1 NUMBER OF $6.00 Permit Total Fees: $24.00 Operator: jmm Printed By: jmm Print Date: 5/23/2008 Permit Center �, c$'°Fiane11703 E Sprague Ave,Suit 3'r- ' 3 BY PERMIT NUMBERF / ' ,.)(-7 Spokane Valley,WA 9006 ' <. VALLEY. PERMIT FEE: 1 ley (509)688-0036 FAX:(509)68a-01137 2 2 www.spokanevalley.org M 2008 Community Development Residential Ail 1' HeAnstruction (l Accessory Bldg PP Permit Application i ,►, • i • ition/Remodel n Deck (l Other: SITE ADDRESS: i� 0 5- - 2-4- ASSESSORS PARCEL NO: 4521-1 .110w5 LEGAL DESCRIPTION: Building Owner: Contractor: Name: Name: Address: 13005 E . 24,-a. Address:. po 40 I(_ 8 S5 b City: SQ01640$3.- v 44u.rti1 State: wit. Zip:n `M ib City: g e0 t i c State: wA. Zip: 9324 .3 Phone: ScA wan- 1e 36 Fax: � Phone: 455-4395 Fax: 509 443_c,22Z Contractor Lic No: NTE(22t9C. Exp Date: 4/2-1 t 0 9 Contact Person City Business Lic.No: 602 440 43 Name: cTEUC Soli^4So'1 Phone: %9 939 .. 37-8(:, Describe the scope of work in detail: Cost of Project: $ (6t v►t,1D F)1)(10' .PcW1 t o4 1 -IC A) l- P:•fert+ 4 L Av N 6i2A1 AREA- Proposed Use: **************The following MUST be complete: (write N/A if not applicable)********************** HEIGHT TO PEAK: it DIMENSIONS:�u�t k(0 l #OF STORIES: 1 TOTAL HAS. SPACE: iki MAIN FLOOR TO SQ.dt"ri(4u FLOOR SQ. FTG: UNFIN BASEMENT SQ. FTG: IMPERVIOUS SURFACE FTG: hii /+ $F Al/P— NIA- AREA: HA SQ I FSHED TG: BASE M/ .,,F,T GARAGE SQDECK/COV. P,Q O SQ. FTG: 30% SLOPESTYON pro #OF BEDROOMS CONSTRUCTION TYPE: HEATSOURCE: � SEWER ORS '? � S 6tA.0612, The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling, the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or local laws,codes or ordinances.6) Plans or additional information may be required to be submitted,and subsequently approved before this application can be pr ed. SIGNATURE: � DATE: 9/24 I 0$ Method of Payment: 0 Cash 0 Check 0 Mastercard 0 VISA Bankcard#: Expires: VIN#: Authorized Signature: - Effective 10-28-07 Page 1 of 1 C:\Users\Steve&Teresa\Documents\My Downloads\Residential%20%20Building%20Permit%20App.doc Permit Center atter 11703 E Sprague Ave,Suite B-3 PERMIT NUMBER: Spokane Valley,WA 99206 4000011rVd.11'` (509)688-0036 FAX:(509)688-0037 PERMIT FEE: Community Development www.spokaneval leti.org Mechanical Permit Application ❑ Commercial a. Residential SITE ADDRESS: r t 05 E. Building Owner Name: ISN * GfzAl S T-i't„ M G I'tt Ir IJ EL t . Phone: ) 922_X67 3‘, Fax: Address: e;b06 E . 7.44.0. City: SictjrCA4E va,t4.4 State: wil_ Zip: !�6 Contractor Name: ctrr'o-bLt rti0l0a-1.1 ti!L Phone: '509 " 4.3` l Fax: 50. 443-S22,2- Address: Po �U� 8r,� 1p�p ,.Q City: cp.A r State: V.4-4 Zip: 99 3 License No: $N TEt.f2.1 96 2vi% i City Busmess Lic: 60 Z 410 431_ Contact c�.� Name: c.rEU E at 4 r4(0,".1 Phone: IJP3 186 DESCRIPTION OF WORK #OF UNITS X COST = TOTAL AMOUNT 1 FUEL BURNING APPLIANCE Equal to or less than 100,000 X $12.00 = 2 FUEL BURNING APPLIANCE More than 100,000 X $15.00 = 3 UNLISTED APPLIANCE(Additional Fee) Equal to or less than 400,000 X $50.00 ,= 4 UNLISTED APPLIANCE(Additional Fee) More than 400,000 X $100.00 = 5 USED APPLIANCE(WSEC min.AFUE rating) Equal to or less than 400,000 X $50.00 = 6 USED APPLIANCE(WSEC min.AFUE rating) More than 400,000 X $100.00 = 7 BOILER/REFRIGERATION 1-100M BTU X $12.00 = 8 BOILER/REFRIGERATION 101-500M BTU X $20.00 = 9 BOILER/REFRIGERATION 501-1,000M BTU X $25.00 = 10 BOILER/REFRIGERATION 1,001-1,750M BTU X $35.00 = 11 BOILER/REFRIGERATION More than 1,750M BTU X $60.00 = . 12 GAS LOG,GAS INSERT,GAS FIREPLACE X $10.00 = 13 RANGE X $10.00 = 14 DRYER i X $10.00 = f 0• O 15 FUEL BURNING WATER HEATER X $10.00 = 16 MISC.FUEL BURNING APPLIANCE X $10.00 = 17 GAS PIPING(each outlet) X $1.00 = 18 DUCT SYSTEMS X $10.00 = 19 VENTILATING FANS X $10.00 = Z© `'= 2- 20 AIR HANDLER DOES NOT include ductin.) Equal to or less than 10,000 CFM X $12.00 = 21 AIR HANDLER(DOES NOT include ducting) Greater than 10,000 CFM X $15.00 = 22 EVAPORATIVE COOLERSX $10.00 = 23 TYPE I HOOD X $50.00 = 24 TYPE II HOOD X $10.00 = 25 HEAT PUMP/AIR CONDITIONER 0-3 TON X $12.00 = 26 AIR CONDITIONER 4-15 TON X $20.00 = 27 AIR CONDITIONER 15-30 TON X $25.00 = 28 AIR CONDITIONER 30-50 TON X $35.00 = 29 AIR CONDITIONER More than 50 TON X $60.00 , = , 30 LPG STORAGE TANK X $10.00 , = 31 WOOD OR PELLET STOVE/INSERT X $10.00 = 32 WOOD STOVE-FREE STANDING X $25.00 = 33 REPAIR&ADDITIONS X $15.00 = 34 VENTILATION SYSTEMS X $12.00 = 35 VENTILATION MECHANICAL EXHAUST X $12.00 = 36 INCINERATOR-RESIDENCE X $19.00 = 37 INCINERATOR-COMMERCIAL X $22.00 = METHOD OF PAYMENT: SUBTOTAL DCASH 0 CHECK 0 VISA ❑MC EXPIRES: PROCESSING FEE $35.00 CARD#: 3...., s. IN: TOTAL PERMIT FEE DUE: 4tAUTHORIZED SIGNATURE: Effective 10-28-07 P\Community Development\Forms\Building fottns\Mechanical Permit Application.doc Permit Center Spokane 11703 E Sprague Ave,Suite B-3 Spokane Valley,WA 99206 PERMIT NUMBER: (509)688-0036 FAX:(509)688-0037 PERMIT FEE: Community Development www.spokanevallev.org Plumbing Permit Application ❑ Commercial ii/A Residential SUFE ADDRESS: (. 80 , Building Owner Name: i1.4 G critt, 04E_t.,(,4 1 S(✓1 Le..IG Phone: 50, 922,_/133‘ Fax: Address: (? ` .,Tv City: cg5 KA. ,,A„4-04 State: Vv x_ Zip: 93.2,140 Contractor Name: •(.3TE626r1( l m. r,Et-tNv Phone: 455 4'33GJ Fax: 5o9 443 `�Z22 Address: 1)0 A,0 55�, City: 0064.„.4 State: wQ Zip: 9.9 2.. License No: 214 Te4,12..1 35201 t City Business Lic: b62 41 43 Contact Name: 5rr� zpt4N Sunt/ Phone: Lj0 9 93(}378‘, — DESCRIPTION OF WORK #OF UNITS X COST = TOTAL AMOUNT 1 TOILETS WATER CLOSET,BIDETS X $6.00 = 2 URINALS X $6.00 = 3 TUBS X $6.00 = I 4 SHOWERS(PER TRAP) BATH,STALL,ON-SITE BUILT X $6.00 = l LAVS/BASINS,BAR,FLOOR,KITCHEN, 5 SINKS LAUNDRY,UTILITY,JANITOR,PHOTO, . X $6.00 = Z X-RAY,FOOD,PREP/CULINARY MEAT 6 DISHWASHER X $6.00 = 7 CLOTHES WASHER 1 X $6.00 = L 8 GARBAGE DISPOSAL X $6.00 = 9 WATER SOFTENER X $6.00 = 10 ELECTRIC WATER HEATER NOTE: IF GAS,SEE MECHANICAL X $6.00 = AREA,CASE,COIL,TRENCH, 11 FLOOR DRAINS CONDENSATE X $6.00 = 12 ROOF DRAINS/OVERFLOW DRAINS X $6.00 = 13 FOUNTAINS,DRINKING X $6.00 = WATER PIPING/DRAIN-IN WASTE, NSTALLATION,ALTERATION,REPAIR, 14 VENT,PLUMBING,REVERSAL REVERSALS X $6.00 = 15 SEWAGE EJECTOR GRINDER,SUMP PUMP X $6.00 = ICE AN/OR COFFEE MAKER,HOSE BIB, 16 WATER USING DEVICE STEAMER X $6.00 = PROOFER,CARBONATOR,SWAMP COOLER VACUUM BREAKER,CHECK VALVE, AND R.P.B.P.D.FOR: VATS,TANKS, 17 CROSS CONNECTION DEVICE BOILERS X $6.00 = GREASE TRAP,SAND TRAP, 18 INTERCEPTORS CHEMICAL HOLDING TANK X $6.00 = 19 MEDICAL GAS(per outlet) NITROUS,OXYGEN X $8.00 = 20 MISCELLANEOUS PLUMBING FIXTURE X $6.00 = 21 PRIVATE SEWAGE DISPOSAUSYS X $20.00 = 22 INDUSTRIAL WASTE INTERCEPTOR X $15.00 = SUBTOTAL METHOD OF PAYMENT: PROCESSING FEE ❑CASH 0 CHECK 0 VISA 0 MC EXPIRES: $35.00 Card# VIN: TOTAL PERMIT FEE DUE: A 59.00 AUTHORIZED SIGNATURE: (4V " Effective October 28,2007 C:\Users\Steve&Teresa\Documents\My Downloads\Plumbing%20Permit%20Application.doc WASHINGTON STATE ENERGY CODE TABLE 6-2 PRESCRIPTIVE REQUIREMENT S°'1 FOR GROUP R OCCUPANCY CLIMATE ZONE 2 Wall12 Wall. Wall. Slabs Glazin Glazin U-Factor a a Area'o9 Door a Ceilingz Vaulted Above int ext Floors on Option » Below Below Grade U-Factor Ceiling Grade of Floor Vertical Overhead Grade Grade I. 12% 0.35 0.58 0.20 R-38 R-30 R-21 R-21 R-12 R-30 R-10 int? II.* 15% 0.35 0.58 0.20 R-38 R-30 R-19+ R-21 R-12 R-30 R-10 R-58 III. 17% 0.32 0.58 0.20 R-38 R-30 R-19+ R-21 R-12 R-30 R-10 R-58 IV. 25% 0.35 0.58 0.20 R-38/ R-30/ R-21 R-15 R-12 R-30/ R-10/ Group U=0.031 U=0.034 int? / U=0.029 F=0.54 and R--22 U-0.054 Occupancies Only V. Unlimited 0.35 0.58 0.20 R-38 R-30 R-19+ R-21 R-12 R-30 R-10 Group R-3 R-58 and R-4 Occupancies Only VI. Unlimited 0.30 0.58 0.20 R-49 or R-38 R-21 R-21 R-12 R-30 R-10 Group R-3 R-38 Adv int? and R-4 Occupancies Only VII. Unlimited 0.32 0.58 0.20 R-38/ R-30/ R-21 R-15 R-12 R- 029 F=0.5410/ Group R-1 U=0.031 U=0.034 int? / and R-2 U=0.054 Occupancies Only * Reference Case 0. Nominal R-values are for wood frame assemblies only or assemblies built in accordance with Section 601.1. 1. Minimum requirements for each option listed. For example,if a proposed design has a glazing ratio to the conditioned floor area of 13%,it shall comply with all of the requirements of the 15%glazing option(or higher). Proposed designs which cannot meet the specific requirements of a listed option above may calculate compliance by Chapters 4 or 5 of this Code. 2. Requirement applies to all ceilings except single rafter or joist vaulted ceilings complying with note 3. 'Adv'denotes Advanced Framed Ceiling. 3. Requirement applicable only to single rafter or joist vaulted ceilings where both(a)the distance between the top of the ceiling and the underside of the roof sheathing is less than 12 inches and(b)there is a minimum 1-inch vented airspace above the insulation. Other single rafter or joist vaulted ceilings shall comply with the"ceiling"requirements.This option is limited to 500 square feet of ceiling area for any one dwelling unit. 4. Below grade walls shall be insulated either on the exterior to a minimum level of R-12,or on the interior to the same level as walls above grade. Exterior insulation installed on below grade walls shall be a water resistant material,manufactured for its intended use,and installed according to the manufacturer's specifications. See Section 602.2. 5. Floors over crawl spaces or exposed to ambient air conditions. 6. Required slab perimeter insulation shall be a water resistant material,manufactured for its intended use,and installed according to manufacturer's specifications. See Section 602.4. 7. Int.denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation. 8. This wall insulation requirement denotes R-19 wall cavity insulation plus R-5 foam sheathing. 9. Doors,including all fire doors,shall be assigned default U-factors from Table 10-6C. 10. Where a maximum glazing area is listed,the total glazing area(combined vertical plus overhead)as a percent of gross conditioned floor area shall be less than or equal to that value. Overhead glazing with U-factor of U=0.40 or less is not included in glazing area limitations. 11. Overhead glazing shall have U-factors determined in accordance with NFRC 100 or as specified in Section 502.1.5. 12. Log and solid timber walls with a minimum average thickness of 3.5"are exempt from this insulation requirement. Effective July 1,2007 34 3(IV -117-Z 3'- r4. 0153 lN1 1SP(j cel rou►acid PLANNING DEPT. APPROVED BY: 411N. DATE: 5/);/; 7 I 4 10g ' N1101.3.1-Attic insulation certification required as to R-value or coverage. Markers, attached to trusses or 2)CC L c-06-dK cit—AC..- 80�,rz a) t ''oC rafters, required for every 300 sf of attic space with 1 o i2^5 u PP�lLreti e y r� P�- 'rs inch high numbers for installed thickness of insulation. kik Frdt.6 12 1-3 co`f ---- y 1/8" GAP 4vSiUS(3 S (4,1-1-14,-r, n/ ' BE Attic Accessible St-t> felt for ice by 22' x 30" dam protection zi,(0 To 1-,4 rwrit,le" . � )(G. cc?L,N6 7'd /JrJ € rfr.A/ L. ''OG b.►. Ek i ei40A W.4"" v. — cot,iv i3 u c fK:1 A 6 CEILING: 'h"GWB allowed if liVAUC.ANE �N��r U�� perpendicular to rafters or trusses 24"oc and no water based texture t(l % used—otherwise 5/8"GWB. 4------ Z. Water-Resistive Barrier required under siding ''z- PL i w j St niv‘ . il.�' wit.* .,.----2xb 5n/0C (( OL CONCRETE TO�YlTO lid TABLE 1(1) 1 OPAL - � 6414,24e2— FOUNDATIQN,WAus-9000 PSI SUBS,GARAGES,CARPORTS &PORCHES•3560 i PSI Minimum depth for frost protection in the City of Spokane MUST4$E CONTINUOUS Spokane Valley is 24 inches measured from the bottom of the footing to finish grade. Grade slope away from building a minimum 6 inches in first 10 feet. p. .°IfIAZ -XICI P P�- .� Anchor Bolts- Min. 1/2"x 9" ytt(Ai 2-4�ro G I" with 7"concrete embedment aftvvV S j9L P,,-c' at 6' o.c.and 12"from ends Under Floor Ventilation of sill plates. I Sq Ft per every 150 Sq Ft of under L-eloor4 space area. teacntiiang opening shall 2A6' Q,. e 6� within 3 feet of-each corner. 17r� 4h_,1 be covered with approved material.14.40)( -Radon Mitigation System I b4 Damp-Proofing required on required with 6 mil (4 1 foundation walls from top of Vapor Barrier footing to finished grade of crawl space or basement / / /'r/ i I LANDING required on both sides of exit doors with min.size of 3 ft.measured in direction of travel by 3 ft.or width of door if greater,and not lower than 1 'h in.below threshold.Landing required at other exterior doors is a minimum size of 3 ft travel distance by width of door,and not lower than 7 3/4 in.below threshold provided the door does not swing over the landing. STAIRWAYS: Minimum width 36 in. with min.tread run of 10 in., max. rise of 7 3/4 in. &nosing of 3/4-1 'A in. Min. 6 ft. 8 in. headroom. E $_.. - , n I - e s - .1 1 2 1 ''.1 5 0 fio4it • V I - r� C j. e a. (0' r ' L 111, P \r ixtfl LTotvr It 4. HEN INTERIOR ALTERATIONS,REPAIRS OR ADDITIONS R WIRING A PERMIT OCCUR,OR WHEN ONE OR MORE S EEPING ROOMS ARE ADDED OR CREATED IN EXISTING D RINGS, THE DWELLING UNIT SHALL BE PROVIDED W TN SMOKE ALARMS LOCATED AS REQUIRED FOR NEW D ELLINGS. I :,,:it !.,.- tV 1 :n0!t « - t _tet--- { SMOKE ALARMS SHALL BE INTERCON- NECTED AND HARD WIRED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL ALARMS. E iUST1A..TC (BEDROOMS, AREAS APPROACHING � Washington State Ventilation BEDROOMS , VAULTED CEILING and Indoor Air Quality Code WITH RISE OF 24" & ON EACH FLOOR) SO- F1 requires a source specific and .i/SN tb whole house ventilation system To la XX CRt os 146 2.1*4 Brace Wall Panel min.48 in.-96 in. R602.10.5 Continuous Wood Structural Panel Sheathing R602.10.6.1 Alternate Brace Wall Panel min.28in.-42in. R602.10.6.2 Alternate Brace Wall Panel min.16in.-24in. IBC 2305 Engineered Shear Wall Bracing PROVIDE DIAGRAMS AND ENGINEERING LAYOUTS FOR ROOF TRUSSES, BEAMS AND FLOOR SYSTEMS PRIOR TO FRAMING INSPECTIONS CITY COPY THIS BUILDING SUBJECT TO FIELD,INSPECTION CORRECTIONS jr REVIEWED FOR CO3E; s . IiLIAN� SPOKANE VALLEY B.i ♦ING ►,IVISIO T' ( sa o, For City Us- Only � f CITY• PLUS Project Number IP ' " iv Spokane Project Address 436-0 all ° ey 11703 E Sprague Ave Suite B-3 ♦ Spokane Valley WA 99206 509.688.0036 • Fax: 509.688.0037 • permitcenter@spokanevalley.org As part of our on-going commitment to customer service during the review process of your project application, we are providing you with a TARGET DATE for the initial technical application review. If for any reason we cannot meet this date, we will contact you with a revised target date. Your application review TARGET DATE is The TARGET DATE is the date we estimate your project application will have had its initial technical review. It is not the date for approval or permit issuance. Tips for a Smoother Prosect Application Review ➢ Submit complete, accurate plans and documents. Extra time may be. required for re-submittals as project application reviewers work on multiple applications and it may be several days before they can look at your new or revised information. ➢ Designate a specific contact person to communicate with the City. While the person designated as the applicant's contact person with the City can be changed, one individual with the expertise for dealing with reviewer comments would be the best choice for the entire review process. ➢ Call staff regarding the status of your project only after the target date shown at the top of the page. Although you should be contacted on or by the target date,please feel free to contact us if you haven't heard from us by your target date. Staff may contact you before the target date if the initial review is complete. By following this procedure,you will save time and allow the reviewers to complete the work more expeditiously. Steps in the Permit Process 1. Counter Complete. Your application has been accepted as counter complete. This means all of the required documents, as indicated on your Pre-Application Checklist have been submitted or have been approved for deferred submittal.This does not prevent technical staff from requesting additional information as a result of their technical review. 2.Quality Check. The next step in the process is a quality check to make sure that the application is reviewable and free from substantive flaws that would prevent technical staff from completing the technical review once it is started. When this step is complete, your application will be routed to the appropriate staff and remain in their review queue until it comes up for review. 3. Technical Compliance. Once an application is administratively complete, it is routed to technical staff for c mpliance review. Depending on the .type of project, technical staff may include multiple reviewers. You should be cont cted by phone,fax, email,or mail by your TARGET DATE once the initial technical compliance review is complete. 4. Permit Issuance. When the technical compliance review of the application is complete, including any subsequent re- submittals, each reviewer will approve their section of the application and route it to the Permit Center. When all sections of the application are received, a Permit Specialist will process the application and contact the person specified on your application for permit pick-up. Information regarding fees and pre-construction meetings (if required)will be provided by the Permit Specialist at that time. WHITE—APPLICANT PINK—BUILDING FILE REV 9/07