1991, 12-20 Permit App: 91008601 ResidenceL 0 �r Lord d locK / 7 J? f G�b 2 V Z P,(`-�rT IV Lord d locK / 7 J? f G�b 2 V Z P,(`-�rT THESE PLANS HAVE BEEN REVIEWED 4L_r `l ON `f —� (8stikla'qt (tst'llost atkoll P 8620 44th Spokane, ua . 99206 Phone 509 926-6217 Fax 509 928-8689 mitigation system Legend for Radon 9beneath slab perForated pipe vent pipe CI said 9'RBS stackAT1 RADON SYSTEM SPECIFICATIONS . Evergreen Point RADON MITIGATION SYSTEM This radon mitigation system is job- ned only for the specific s ;tern designed designated. . Tha Y site address desi9 unless installed is not guaranteed by Cavalier Corporation � 4p24 E 25th lob site address, SL • Smith Homes c`': C ,1 s Olt : ,�•.JAi U.Q, 1ate Q r r - Environmental Protection Agency RCP v fes. 'r7I(T ,,,avalier i radon w w E. 8620 44th * Spokane, WA 99206 Phone (509) 926-6217 FAX (509) 928-8689 RADON SYSTEM SPECIFICATIONS, SPOKANE COUNTY: 1. Perforated pipe shall be installed within the native soil or fill (sand, gravel or soil) at a minimum depth of 1" below the intended slab. 2. The pipe shall be a minimum diameter of 4". meet AASHTO M252, have perforations no wider than 1/16" and have a minimum of 2.5 square inches of total perforations per linear foot of pipe. 3. There shall be a minimum of 10 linear feet of perforated pipe per hundred square feet of slab floor space. 4. The pipe shall be laid in a continuous loop. connected at both ends to the solid stack vent pipe. 5. Any slab area, which is larger than 10 square feet, which is isolated from other slab areas by footings or other barriers, shall have a perforated pipe installed to the above specifications. (The pipe can be a single length rather than a connected loop if the area is too small or narrow to accomodate a connected loop.) 6. A stack vent of ABS, schedule 40, minimum size 4", shall be connected to the sub -slab piping and proceed upwards to an exit location on the roof, and extending 14" above the roof. The pipe shall be labeled "radon vent" every 16" or less for its full length. The pipe's attic location shall allow a minimum of 4' of head room. When- ever possible this exit location shall be on the backside of the roof. 7. Any elbows in the stack vent piping shall have a centerline radius minimum of 1.5 by pipe width. 8. An inline centrifugal fan, minimum 1.14 cfm @ 3/8" W.C., UL listed, manufactured specifically for radon mitigation, maximum sone level 2.8, shall be installed in the exhaust line, in the attic. 9. Couplings to connect the vent piping to the fan shall be elastomeric PVC, Fernco series 1056 or equal. 10. The fan shall be hard -wired and the breaker labeled "radon fan" . 11. All penetrations and joints in the concrete floor slab below grade shall be sealed with caulk or grout. 12. A notice shall be permanently attached to the electrical panel advising the owner or occupant about the radon system and that he/she shall test the home for radon annually. The notice shall include Cavalier's name and. phone number. 13. All craftsmanship shall be of high quality.