Loading...
2006, 05-24 Permit App: 06001985 Repair Fire DamageProject Number: 06001985 Inv: I Application Date: 5/24/2006 Page 1 of 2 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Proiect Information: - Pemut Use: INTERIOR FIRE DAMAGE REPAIR Contact: CAPSTONE CONSTRUCTION Address: PO BOX 388 C - S - Z: NINE MILE FALLS, WA 99026 Setbacks: Front Left: Right: Rear: Phone: (509) 468-4981 Group Name: Site Information Project Name: Plat Key: 001230 Name: HILLCREST ACRES 07TH ADD District: F Parcel Number: 45273.2917 Block: Lot: SiteAddress: 12415 E 27TH AVE Owner: Name: WARFIELD, JOHN Location:: CSV Address: 12415 E 27TH AVE SPOKANE VALLEY, WA 99216 Zoning: SFR Water District: Hold: ❑ Area: .00 Acres Width: 0 Depth: 0 Right Of Way (ft): 50 Nbr of Bldgs: 0 Nbr of Dwellings: 1 Review In ormatton: Review Building Plan Review Released By: Building Permit Contractor: CAPSTONE CONSTRUCTION Firm: CAPSTONE CONSTRUCTION Address: PO BOX 388 Phone: (509) 326-0908 NINE MILE FALLS, WA 99026 Description Grp Type Notes 1 &2 FAMILY R-3 VB VALUATIO N Item Description RESIDENTIAL PERMIT FEE WSBC SURCHARGE SF PLNS RVW < 7999 SQ FT Totals: This Application: Sg Ft Valuation 0 $90,000.00 0 $90,000.00 Units Unit Desc 1 SELECT 1 SELECT 1 SELECT Permit Total Fees: Operator: AMB Printed By: AMB Print Date: Total Project: Scl Ft Valuation 0 $90,000.00 0 $90,000.00 Fee Amount $923.75 $4.50 $369.50 $1,297.75 5/24/2006 Project Number: 06001985 Inv: I Application Date: 5/24/2006 Page 2 of 2 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Notes: 4 F Payment Summary:�- Permit Type Fee Amount Invoice Amount Amount Paid Amount Owing Building Permit $1,297.75 $1,297.75 $0.00 $1,297.75 $1,297.75 $1,297.75 $0.00 $1,297.75 Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: AMB Printed By: AMB Print Date: 5/24/2006 MAY -24-2006 09:20 AM Capstone Construction 1 509 468 5081 -/ P.03 t dr -P' B APPLICATION WORKSHEET ofSpokaneV�eymuniiy Development DepartmentMAY Z 4� Building Division 7 E. Sprague Avenue, Suite 106 (1 1 L L Wn Spokane Valley, WA 99206 . ( 688-0036; Fax: (509) 688-0037 REQUIRED SITE INFORMATION Street Address: 7 Assessors Tax Parcel Number(s): Legal Description: PERMIT DESCRIPTION: i! -e .Building Permit ❑ Change In Use ❑ Grading ❑ Manufactured Home ❑ Relocation ❑ Tenant Improvement ❑ Fire Safety ❑ Other I OWNERIAPPLICANT INFORMATION a ❑ Owner. Va/%v AlAFfiF.-c..6 ❑ Phone: Fax: Address: Z z 7M Avg., ty stats Zip code Contractor. 6W SnW £ CCAISnWe.TroMI.We❑ Phone: Vblr-V9PJ Fax:4441--dWT1 Address: TV _ mue."lle mals u1A- 9 fo2G city state Zip Code Applicant: Phone: Fax: Address: City state Zip Code Architect. Phone: Fax: Address: City state Zip Code WA State Contractor License #: CAPSTCG.106T5 Contact: %w�,w Spokane Valley Bus. Liscense #: E Contac: PERMITIBUILDING INFORMATION # HEIGHT TO PEAK: DIMENSIONS: # OF STORIES: MAIN FLOOR TO SQ. FTG: FLOOR SQ. FTG: UNFIN BASEMENT SQ. FTG: FINISHED BASEMENT SQ. FTG: GARAGE SQ. FTG: DECK/COV. PATIO SQ. FTG: OCCUPANCY GROUP: # OF BEDROOMS: CO OF PROJEoC�T: SArD. ozo --^ CONSTRUCTION TYPE: TOTAL HABITABLE SPACE: 3096 SLOPES ON PROPERTY: HEAT SOURCE: IMPERVIOUS SURFACE AREA: SEVlfER OR ON-SITE SEPTIC SYSTEM? MAY 24 2006 08:43 PAGE.03 MAY -24-2006 09_20 AM Capstone Construction 1 509 468 5081 P.04 I MANUFACTURED HOME Width: Length: Year. Pit Set: Manufacturer. Previous Address: Proposed Use:, _ RELOCATION FIRE SAFETY Fire Sprinkler # of Heads: Fire Alarm: Tent: Fireworks Display: Blasting: Valuation: Above/Underground Storage Tank Size: Paint Booth: DatefTime: WASHINGTON STATE NON-RESIDENTIAL ENERGY CODE Plans Examiner. Phone: Fax: Address: city State Zip Inspector. Phone: Fax: Address: city stale 71p SPECIAL INSPECTIONS ❑ BOLTING ❑ CONCRETE Firm Name: Inspector(s): ❑ REINFORCEMENT Phone: Fax: ❑ WELDING DISCLAIMER The permitee verifies, acknowledges and agrees by their signature that: 1) if this permit is for construction of or on a dwelling, the dwelling ishvitl be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory Is the property owner or has permission to represent the property owner in this transaction. 4) All construction Is to be done In full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center.. 5) This c city of Spokane Valley permit Is not a permit or approval for any violation of federal, state or local laws, codes Ownership of resulting development rights granted by any issued permit Inure the property owner. Print Name 5�7 i�xdNsd Signature Method of payment. (Foxed permit ❑ Cash F1 Check wX only be accepted with major bankcard) Mastercard N VISA ❑ Other Qc Bankcard #• _ --- Q� - -I- '­� 'Z101 l Authorized Signature: MRY 24 2006 08:44 VIN#: This document originally contained confidential credit card information which was redacted pursuant to RCW 19.255.010 and the original document destroyed pursuant to SOS DAN GS2014-030. MAY -24-2006 09:19 AM Capstone Construction 1 509 468 5081 ,4 ?'O insurance C+ h' '' ` Restoration Work, Remodeling & CONSTRUCTION Additions FEDERAL. TIN: 91-1475627 ` Fax P.01 Fare 46 pt a Data Ree CCI -11 0 Urgent O For Rwisw 0 Pieass Comment O Please RsPly (509) 468-4981 * FAX: (509) 468-5081 Mailing Address: P.O. Box 388 * NINE MILE FALLS, WA 99026 physio Address: 2917 E.' FRANCIS AVE. * SPOKANE, WA 99208 Email: ccaQstonenc@yahoo.com * Web Site: www.capstonegons ructi n z a com Your Disaster Restoration specialists! MAY 24 2006 08:42 PAGE.01 MAY -25-2006 04:04 PM Capstone Construction 1 509 468 5081 P_01 FEDERAL TIN: 91-1475627 Fax 111101 1.2 sem z7 �� Cel Insurance Restoration Work, Remodeling & Additions ❑ Urgent ❑ For R*Www E3 P119000 CommoM O PIGOw RoPly W w w w w w w w w w w w w w w w w 0 w w w w w w w www w w w w w w w w (509) 468-4981 * FAX: (509) 468-5081 Mailing Address: P.O. Box 388 * NINE MILE FALLS, WA 99026 Physical Address: 2917 E. FRANQS AVE. * SPOKANE, WA 99208 Email: caostoneoc@vahoo.com * Web Site: www caostoneconstruction bizland com Your Disaster restoration specialists! MAY 25 2006 15:28 PAGE.01 Address: I ! l 7 r4\ Project #: CORRECTION NOTICE Date: Spokane Valley Building and Code Enforcement Prior to proceeding, the items listed must be corrected and inspected. Failure to do so may result in additional fees being assessed. Please call for reinspection when corrections have been completed. Far turthcr information call Inepcctor SPs;31, AM& VALLEY NOTICE 8F !N5PgCTII5.N 13RQPERTY AnQR€SS: z- L PROD€CT MQ, QWNER ,�trz, 6 CONTRACTOR 4 z x_1.4 kz�'�1�� INSPECTION TYPE: ',tom - Ir'IV ST4TUS OF WORK LISTED ABOVE, APPROVED CORRECTIONS NEEDED NOTES: BY: INSPECTOR - UTE QUESTIONS? CALL OUR OFFICE: BUILDING DIVISION OFFICE INSXTIOCOO-003(i LINE (509) eea_oosa CALLED IN: *I _ _DATE Mille TIME at 509-088-0030 between the hours of 8 end 9 a.m. weekdays. W SEC TABLE 6-2 PRESCRIPTIVE REQUIREMENTSOA FOR GROUP R OCCUPANCY CLIMATE ZONE 2 * Reference Case 0. Nominal R -values are for wood frame assemblies only or assemblies built in accordance with Section 601.1. Minimum requirements for each option listed. For example, if a proposed design has a glazing ratio to the conditioned floor area of 13%, it shall comply with all of the requirements of the 15% glazing option (or higher). Proposed designs which cannot meet the specific requirements of a listed option above may calculate compliance by Chapters 4 or 5 of this Code. 2. Requirement applies to all ceilings except single rafter or joist vaulted ceilings. 3. Requirement applicable only to single rafter or joist vaulted ceilings. 4. Below grade walls shall be insulated either on the exterior to a minimum level of R-10, or on the interior to the same level as walls above grade. Exterior insulation installed on below grade walls shall be a water resistant material, manufactured for its intended use, and installed according to the manufacturer's specifications. See Section 602.2. 5. Floors over crawl spaces or exposed to ambient air conditions. 6. Required slab perimeter insulation shall be a water resistant material, manufactured for its intended use, and installed according to manufacturer's specifications. See Section 602.4. 7. Int. denotes standard framing 16 inches on center with headers insulated with a minimum of R-5 insulation. COOPERATIVE EXTENSION WSEC Builder's Field Guide 5th Edition WASHINGTON STATE UINTIVERSITY 1.7 i 15 ENERGY PROGRAM Glazing Glazing U -Factor Door9 WaII12 Wall? Wall? 6 Sonb Option Area'0: U- Ceiling Vaulted Ceiling Above Int" Below ext" Below Floors % of floor Factor Grade Grade Grade Vertical Overhead" Grade I. 10% 0.40 0.58 0.20 R-38 R-30 R-21 R-21 R-12 R-30 R-10 int? II. 150/6 0.40 0.58 0.20 R-38 R-30 R-19+ R-21 R-12 R-30 R-10 R-56 III. 17% 0.37 0.58 0.20 R-38 R-30 R-19+ R-21 R-12 R-30 R-10 R-56 IV. 25% 0.35 0.58 0.20 R-38 / R-30 / R-21 R-15 R-12 R-30 / R-10 / Group R-1 U=0.031 U=0.034 inf / U=0.029 F=0.54 Occupancy U=0.054 Only V. Unlimited 0.35 0.58 0.20 R-38 R-30 R-21 R-21 R-12 R-30 R-10 Group R-3 int' Occupancy Only VI. Unlimited 0.32 0.58 0.20 R-38 / R-30 / R-21 R-15 R-12 R-30 / R-10/ Group R-1 U=0.031 U=0.034 int' / U=0.029 F=0.54 Occupancy -Only---- - U=0.054 * Reference Case 0. Nominal R -values are for wood frame assemblies only or assemblies built in accordance with Section 601.1. Minimum requirements for each option listed. For example, if a proposed design has a glazing ratio to the conditioned floor area of 13%, it shall comply with all of the requirements of the 15% glazing option (or higher). Proposed designs which cannot meet the specific requirements of a listed option above may calculate compliance by Chapters 4 or 5 of this Code. 2. Requirement applies to all ceilings except single rafter or joist vaulted ceilings. 3. Requirement applicable only to single rafter or joist vaulted ceilings. 4. Below grade walls shall be insulated either on the exterior to a minimum level of R-10, or on the interior to the same level as walls above grade. Exterior insulation installed on below grade walls shall be a water resistant material, manufactured for its intended use, and installed according to the manufacturer's specifications. See Section 602.2. 5. Floors over crawl spaces or exposed to ambient air conditions. 6. Required slab perimeter insulation shall be a water resistant material, manufactured for its intended use, and installed according to manufacturer's specifications. See Section 602.4. 7. Int. denotes standard framing 16 inches on center with headers insulated with a minimum of R-5 insulation. COOPERATIVE EXTENSION WSEC Builder's Field Guide 5th Edition WASHINGTON STATE UINTIVERSITY 1.7 i 15 ENERGY PROGRAM R' V S�.t+ar�ucrtort Basement Capstone Construction Co., Inc. /2 y/5' zc 175,0ve 2917 E. Francis Spokane, WA 99208 (509) 468-4981, Fax (509) 468-5081 Federal TIN - 91-1475627 WA Registration - CAPSTCCI06J5 Si WLFIEN INTERIOR ALTERARM. IIERAIRS OR AOOIiIONS REWWAIG A POW OCIRIA, OR 00 ONE OR MORE r' SLEEPW ROOMS AAE AOMD ON O INE)NSTNIG OMIELL ". TIE OWELLIMC WT MULL K P vAm CE WATH SMOKE ALARMS LOWED AS ILiOLINIEO IN NEIN � Owfum". SMOKE ALARMS SHALL BE INTERCON- NECTED AND HARD WIRED IN ,SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL ALARMS. (BEDROOMS, AREAS APPROACHING BEDROOMS, VAULTED CEILING WITH RISE OF 24' & ON EACH FLOOR) EXHAUST FANS 100 CFM kitchen 50 CFM bathrooms & laundry Vco-ma To /EKT1eA/p,_ EMERGENCY EGRESS REQUIREMENTS FROM SLEEPING ROOMS 1) NET CLEAR OPENING: 5.7 SQUARE FEET GRADE FLOUR OPENING (MAX 44-) 5.0 SQUARE FEET 2) NE i CLEAR OPENING HEIGHT 241NCHES 3) NET CLEAR OPENING WIDTH 2OINCHES 4) MAX FINISHED SILL HEIGHT 44" ABOVE FLOOR 5) Ekli PGENCY ESCAPE 8 RESCUE OPENING SHALL BE OM RATiCi'4AL FROM THE INSIDE OF THE ROOM WITHOUT THE USE UI KEYS OR TOOLS PROTECTION AND OPENINGS BETWEEN D'drELLING AND PRIVATE GARAGE SHALL HAVE: 1) MA' ERIALS APPROVED FOR ONE HOUR FIRE RESISTIVE CONSTRUC TION ON THE GARAGE SIDE: ❑ 5,8" TYPE "X" GYP BOARD (HABITABLE SPACE ABOVE) OR M ❑ 1112" GYP BOARD (RESIDENCE/ATTIC, FLOOR/CEILING) 2) OPENINGS BEM,EEN GARAGE AND RESIDENCE SHALL BE EOh1PPFO WITH SOLID WOOD DOOR, SOLID OR HONEYCOMB CORE STEEL DOORS NOT LESS THAN 13/8". OR 20 MINUTE FIRE RATED m DOORS. m N N Q C+aw�meM � WARFIELD 05/23/2006 Page: 41 gyp,. & Capstone Construction Co., Inc. 4�1,o2fr,El� corrsraucrlorr 2917 E. Francis Spokane, WA 99208 (509) 468-4981, Fax (509) 468-5081 Federal TW - 91-1475627 WA Registration - CAPSTCC 1005 Upper 0 M m N I In N a WARRELD E 1 i IV k 05/23/2006 Page: 44 U'.I Ti Up Per w C-0 Q CL In lD CD Q N In N r Cl Z plitn if, la CQ1MaueTr* Main WARFIELD Capstone Construction Co., Inc. /2V/5" E z 7' A7-e.C. -- 41.410Cr-4.0 2917 E. Francis Spokane, WA 99208 (509) 468-4981, Fax (509) 468-5081 Federal TIN - 91-1475627 WA Registration - CAPSTCC 106J5 l 3•i'•_a m•7 s,r I— '0' —I 05/23/2006 Page: 43 MAY 25 2006 15:35 Oto 0191 nl FctiON Upper WAR FTELD Capstone Construction Co., Inc. 2917 E. Francis Spokane, WA 99208 (509) 468-4981, Fax (509) 468-5081 Federal TIN - 91-1475627 WA Registration - CAPSTCC 106J5 • ,r„• /2V/5- — liAyeo 1e 05/23/2006 Page: 44 lr Upper MAY 25 2006 15:35 MAY -25-2006 04:05 PM Capstone Construction 1 509 468 5081 P.02 45/23/2000 10:11 5099283933 IRS ENVIRONMENTAL PAGE 03 LIMITED ASBESTOS INSPECTION PRIOR TO RENOVATION WARFIELD RESIDENCE — 12415.'+'AST 27"` STREET SPOKANE VAT.i_.FY__ W_ASMNGTON 1.0 il.(if•lKVDUC T IOiv IRS Environmental of WA, Inc. has completed an asbestos inspection prior to renovation of smoke and fire damage to Warbeld residence at i2417 East 2 t"' Street, Spokane Valley, Washington. The survey for asbestos containing building materials was completed May 9w, 2006 at the request of Vaughn Stevens of Capstone Construction by Dave Sevfert. a certified AHERA Building Inspector under 40 CFR, Part 763, Subpart E, and Appendix C (Certification No. 1021172). This report presents the asbestos survey rncthnric fnintm. and rnnclucinn. i.Yn oTronnece AAtT1 CrAUTi V 1_ L'14 1./V1IAi iiijj AJ11lA a -t Various local, state, and federal regulations govern the use and management of asbestos i:liittctllLU4 (tLalGY1A6 (.-►Ltvt/. tui ivucb iar:c ga;;cttu1"y tvvuaou on k;icr:.uw:Ey auvv,a;:. emissions of asbestos fibers and addressing public and worker health concenis for exposure to asbestos during renovauon and denionuon projects 3.4 SUSPECT MATERIALS TEMD FOR AS ESTOS CONTENT The number of samples taken for any surfacing material is determined by CFR Part 763.56, which requires: - 3 samples for eachh material that is present in quantities of 1,000 SF or less. eamrlPa f(%r path materal that is nrrePnt in nilaliti� of l ,WO - s.non IRV 7 samples for each material that is present in qualities of greater than 51,000 SR In some cases, the inspector is allowed to use discretion and take fewer samples of facioT" manufaciured (noi 5 C TRiXW) materials such io VCT, ceilusg uir:, a3U ruoiu;h. The following materials were tested for asbestos content at the request of the client: Ceiling texture (popcorn) Upper bedrooms and Ball, living I room lower bedrooms and office and associated i ! � �. n+�:n iY+n.♦♦1^ tiiYw � T,,..:n..1 ♦In.+n.�wlYm.f Vat.' Ki�iV 12iJ i{►Ny1Vil 1J }l1VKi Yil: a: w,�. liV �.i. Gold/white sheet vinyl Bathroom j Beige 12x.12 stick on hoor We i Lntry 4.0 SUBJECT SITE DESCRIPTION The subject site is a wood frame tri -level residence. The walls and ceiling are gypsum wallboard throughout the structure with popcorn ceiling finish. Floor treatments are carnet throughout with sheet vinvl in the front entry and bathroom. Forced air heating unit provides heat. The roof has three tab asphalt shingles. MAY 25 2006 15:29 PAGE.02 MAY -25-2006 04:05 PM Capstone Construction 1 509 468 5081 P.03 u.,! ca/ Lr Cb 113:11 5099283933 IRS ENUIROMNENTAL PAGE 0q 5 0 SI VEY —METHODOLOGY Inc, scope of s+ rviccs ii;.i:iuucu 4Q4 . wa !f %v;tHin thr C71P(�1fi(` areas that will be impacted by upcoming renovation activities, to bulk sample and analyze those suspect matcTivis and to prONr)Cie a reP01 0j- UiiUillgS. .i rciicial ovainu -V 47 examination was initially completed to plan the asbestos survey, identify functional spaces (spatially distinct areas witlun the work area), and to deveiop a sarnphiiu ,clivi:-oe for homogeneous area of suspected .ACM. The interior ceiling file finishes were visually inspectod for suspect ACM. Bulk samples were collected in a representative manner by the inspector based on suspected material contents, as defined by regulatory codes or guidance's fbr sampling methods and as applicable to the planned demolition activities. T►,- --m-lse , re nlarrd info airriAt plastic hAP provided by the laboratory. The _a ..,a.___ .. __ S_—_ .. _ - v samples were placed into airtight plastic bags and hand delivered to Mountain * ^i--- ...:w. „� tAMC C 1►Ar��w�MO.Kr l�� Qrt,rl�rana 1�/� h(n�l►7fA1T TA}1f►YAtATIPC IC A lAUlii SiVtiir.7 rZb iVl VJ A,- IIjkV t;, vila+ra� _w*s.� ..� .: _..<..�. .. —a ..._ tiVLAP accredited laboratory for the analysis of bulk materials using PLM - 6.0 WENTIMP MIESTOS CMAMING SAMPLES —+ENDINGS lire ioilolving represents a tabulation of builk wripies, which were found iu w,iittiii asbestos duriug the preparation of this survey and the results of their analysis. SAMPLE MATERIAL LOCATTON ICONTENT QUANTITY m n7 Pnnrnr" nr_.ilin.0 t Tpner twn 1-2% 294 SF texture bedrooms ! j n�i+o nn u i , 11UV 7, U jF,73 W.l t CUA �!C[I 4 .1...,,tt,.U-4 l� �t:l.iil bit V (L�11iJ b.! 1 1-11 04 1 c 131313 cF to , joint compound 13 Gold/white sheet Upper bathroorn 55-60% 50 SF J { vinyl Total wallboard svetem contains lets that 1"1e asbestos. The wallboard system is not considered by NESHAPS as asbestos containing material. However. the watlbeud, They have specific reaairemcnts. i ncludiatg keening the material wet. �p •�_« duri :tw Th a lief AJIY al i'A4VJuG MNSw.�YA6YL z�l.._s. Rss ostiwa itis use ala$ i:auvaauisaa. a ass. v�.Huty a�� via contractor ahould familiarize itself with all rcauircment:t for handling grid seDaratirm tuffs mater7imi prior io b10"Uun. 7.0 REMARKS This report represents TRS Environmental of WA, Inc., findings and conclusions based on the scope of services agreed to by the client and within the client's schedule and budget. All findings are based on readily available and reasonably ascertainable information on site conditions at the time of the survey and for the known regulations in affect at that time. The services provided include professional opinions and judgments based on rs-aA;1y ax ailsnhlp infnrmattnti fiPIA ohorrvatinnc and 7nnAQtltP.n pnt0_ and pnAiviiral MAY 25 2006 15:29 PAGE.03 MAY -25-2006 04:06 PM Capstone Construction 1 509 468 5081 P_04_ - - b5/23/2000 10:11 5099283933 IRS ENVIRONMENTAL PAGE 05 reports by an independent laboratory. The specific conditions and limitations of the AHERA Building Inspector certification have int�uence+i these results, The puix samples collected in connection with this survey only indicate the presence or absence of the investigated contaminant within the discrete sample units. Although the sample was collected from an area most likely to be affected by the contaminant and accessible to the inspector, affected areas may exist in areas not sampled or for potential contaminants not Meted fnr AnMvaia and characterization. Anv analytical results included in this report should be considered only as indicators of possible site conditions with specific statistical a:..wi�3n Ce itis :"fhi n. f. 4 ht! e!am,%J; a tpe, in1lr. and 1SIhnY'iitflty rl'1P.tl1A(ifll(1 LtV_ g.0 i.ZWATI.7„ jN (3F TRIS .R EPURT We have prepared this report to aid in evaluating this property for renovation. This report is for the exclusive use of Capstone ConsLuction, Out structure owner arta IRS Environmental. This report applies only to the subject detailed above and shall not be relied upon by any other party without the prior written consent of the inspector ihat prepared the report. IRS Environmental's work is performed in a professional manner with the best interests of our client in mind IRS Environmental's objective is to perform our work with care, exercising the customary thoroughness and competence of professionals in the relevant disciplines; in accordance with the standard for these services at the time and location those se—ceS are rendered A it !M"rtant to recognize that Pven the most comprehensive scope of services may fail to detect environmental liability on a particular rf e, T.{. ereffore, IRS, End Ironnnentil carmot act as 1nsurCr3 and cannot %ertlf`,-� Cr underwrite" that a site is free of environmental contamination and no expressed or iulplicd rrpresezitation UJ: walfAnty 6-1 lac lWed or intended in our report� :cept, that cur work was performed within the limits prescribed by our client, with the customary thoroughness and competence of our professi.ou. Within the limitations of scope, schedule and budget, our services have been executed in accordance with generally accepted practices in this area at the time this letter was prepared. No other conditions, expressed or implied, should be understood. Nothing in this report should be interpreted as legal advice; the information contained here is for information only. Dave Seyfert APER - A Building 1nspr­ctor Certification No. 1021172 Expiration March 15, 200.5 MAY 25 2006 15:29 PAGE.04 MAY -25-2006 04_07 PM Capstone Construction 1 509 468 5081 = Acoustical ceiling it-N-tt4,e "popcojn,,, 5099283933 IRS ENVIRONMENTAL ' Window glazing • Ductwork flexible connections • Stucco = Acoustical ceiling it-N-tt4,e "popcojn,,, • Cement pipes • Electrical cloth • Cement board/transite • E iectrical wiring irtsulation • Duct tape/paper • Roofing shingles • Furnace insulation • Built-up roofing • Vinyl sheet flooring/mastic • Base flashing • VinyI floor the/mastic • Rolled roofing • Pnured flnorina • Caulking/putties • Pipe insulation/fittings • Incandescent light fixture backing • Plaster/, NT 11 joints • Rric,,J� a„n r • Textured paints/coatings • Vinyl wall coverings ' Ceilaug, ttimpanels!'nastic 'Yapor barrier ' Spray -applied insulation Cement roofing shingles • Blowin-in insulation = Cray ivuftiig paiYii • Fireproofing Nicolet (white) roofing paper • Sink insulation Sub flooring slip-slieet • Packing materials Mudded pipe elbow insulation • High temperature gaskets HVAC duct insulation • Lab hoods/table tops • Boiler/tank insulation • Sink insulation • Breaching insulation • Elevator brake shoes • Pager firebox in walls • Asphalt flooring • Fire doors • Paper on backsirig offiberol&a • Fire hlarkei:a insulation • Fire curtains/hose • p,a,:ot rocfsag material • Electrical panel p rmio Is • Laboratory fume hoods Chalkboards • � tiil�iXlii:tlWl llir`15t]L'S - ici it zoirtpoli-,idlvvallboard Nate: This list does mr include every product that may contain asbestos. It is intended as a general guide to show which types gfmaterfals may contain asbestos. P_ 05 PAGE 06 MRY 25 2006 15:30 PAGE.05 MAY -25-2006 04=07 PM Capstone Construction 1 509 468 5081 P.06 ear 2J/'e0kJb 10.11 5099283933 . IRS ENVIRQNMENTAL PACE 07 110.01%QGGESjjD P_ CEDM FSR rn rinvt��TI SURVEY FENDINGS TO A_FF RQC�'TF P. PARTIES The results of this survey should be posted on site for to ALL CONTRACTORS AND SERVICE PERSONNEL to see. A copy of this report should be provided to all persons who may mme it contact with materials that are known to contain asbestos. The follo-ging is a signed acknowledgment to be collected and signed by anyone who is Provided a copy of this report. I acknowledge that I la ke read and understated the report titled: LAMffED ASBESTOS INSPECTION PRIOR TO RENOVATION WARFIE.LD RESIDENCE -12415 EAST 27'x' STREET SPOKANE VALLEY, WASHINGTON J farther acknowledge that hidden asbestos materials (refer to hist contained in section 9.0 of this report) may exist in concealed anew that way be exposed during demolition. If suspect materials (refer to list contained in section 9.0 of report) are discovered that have not been tested, I will treat these materials as asbestus until additional testing proves otherwise. Firm blame �" C, C 0., 4: Signature Names s S� Title L . Address Z,q kj- f! Phone No. -q6&--41q-F( Date s- z 3 -06 MAY 25 2006 15:30 PAGE.06 MAY -25-2006 04:07 PM Capstone Construction 1 509 468 5081 05/23/2006 10:11 5099283933 IRS ENVIRONMENTAL APPENDIX A RESULTS OF LABORATORY TESTING .ASBESTOS BULK SAM -PINS MAY 25 2006 15:31 P.07 PAGE 08 PAGE. 07 MAY -25-2006 04:08 PM Capstone Construction 1 509 468 5081 P_08 05/23/2006 10:11 5099283933 IRS ENVIRONMENTAL PAGE 09 BULK SAMPLE ANALYSIS FOR ASBESTOS IRS >Envirountentsl Project: Warlivid Dave Seyfert Project #: 8207 PO Box 15216 Spokane WA 99215-5216 vicuwu: rum w1M,LMDcn1Cft ZiWIM i (tient R 1001 %aboratory No. 806-5204 806-5205 .806-520;, �. Sample 1D ?w, 01 02 03 Sample Description Popcorn Popcom Popcotit._._ Samnle Treatment Teased/Crushed Tossed/Crushed Teased/Disstrl ved Dissolved Dissolved Homogeneous No No No Layered Yes Yes Ye.9 Fibrous No Yes i Yes Sample Color Brown/Grey Brown/Grey White/ort-'. Asbestos Present Yes Yes No Asbestos Type and Chrysotile 1-2'.a Chrysotile 1-2% N.D. ..� Percentage i. Chrysotile 2. Amosite 3. Crocidolite 4. Other Total "/c Asbestos 1-2% 1-25w None Ot,�erf:bror�s materia! Cellulose 4% In Sample ._ Gyps n 97-9S. Vo Crypsum 47,9$°% poil,t <1% Paint <1% Paint <1 °/n Binder!Filler 29't -i' Fnwn 6s% Non -Fibrous Material: Paint paint Other ? or,% Other 1 C11! A Paint Other 100% itte Attalvz,-': Miry 9.2006 Anslv>!ed By: licidi L. MoCart)i! Motnnain L.aboroW. W, Diviaatm ofwwtain Inspectliae ^ tnhmhgv 9ervicett. Inc, limits ww"nty to proper apiysis mollwds only mtd token no "ansibilify -MMPTe proetttament. Menmtabt Labomicries.Oivision of Me intale Inspection & Lsbasto*y %eevices, Inc, 9722 t3. Momponlery. Stale M13.9poltane Wsahington 992(ka 04 -1-) 922-1965 = F,: (sQ9; M'-! 93Q. pLt!a hat. ►+een a:+�aaw'o mtss .r..b:�tut an a amen re:ccntaee er emroacs. Th!!� m�nttti�e nt t1u 1K.M tc.uha ¢hound he tesrori,viH+ aithel 3i .n t or T'EM. Client is tosponsiple Rx ample sepnation. This teotot —y only he tgtmdueed in fall with w Altnt aitprev;tl by AMttntain Lobtxntoriex. Page 2 0 6 MAY 25 2006 15:31 PAGE.08 MAY -25-2006 04:08 PM Capstone Construction 1 509 468 5081 Yes P.09 05/23,12026 10:11 5099283933 IRS ENVIRONMENTAL PAGE 10 BULK SAMPLE ANALYSIS FOR ASBESTOS rR5 Environmental Dave Seyfnert PO Box 1.5216 Spokane WA "21.-5.5216 Ubomton No. B06-5207 806-5208 Sample ID Nn. 04 OS Sample Description Popcorn Popcorn Sample Treatment Teased/Dissolved Teased/Dissolved Homogeneous No No Layered Yes Yes FibTOUS Yes Yes Sample Color Whitc,2t.Grey Whitel0ffWhlte Asbestos Present No No Asbestos Type and N.D. N.D. Percentage 1. Chrysotile 2. Arnosite 3. Crocidol ite 4. Other Total % Asbestos None None Otlier fibmus material Collulose 5% Cellulose 9% In sample Paint <1% Paint <1 % BinderiFiller gni o Bindevfiller 36% Non -Fibrous Material.. Foam 65% Foam 55% Paint Paint Other 100% I Other 100" Prnject; WarrivId project #: 8211` t„7ectlt 0 3tig1 B06-5209 06 GWB Teased/Cru, nod No Yes Yes rJ.ffwhitslc :•ry No N.D. None Cellulose 1.0% Gypsum 851/n Birlder,''.Filler Heidi L. McCwlli\ Nv"i tai, t. +Mrae?ie.. T*A. oii of A':R?Ptrin to re a"Cr A Labointay Sr -Am. I -a. VIR-114 w n,nnty m r t4vr n(iatyck i"ectMa ally and takcF Ro n-tm0111MAy 1 •• .nmple riwouraenent. Mount 6 Labnrala6m DivWon of W wnt io, lnepeetion A t. horeiety sotvlen Inc, 9921 F„ wrnntpniaery, suite "13. swkine Wnnlnlann Y42co i P, 1) 9%-1 X03 - Fax (5097 922-1310. T%M hr beam known in rotes abealae in n molt ratcentap of nmples. Time eetplivo er <HS PLM resultF fluudd he itmod with either 51 r 1 nr VW. Clicnt i.._.7 n leiblc fcn eenlplc regeroWt. TNe report RW only k tehmduot:d in foil whh written amwoval by Mmintnin Lebanlmics. Page 3 of 6 MAY 25 2006 15:32 PAGE.09 MAY -25-2006 04:09 PM Capstone Construction 1 509 468 5081 Ob/2312006 10;11 5099283933 IRS ENVIRONMENTAL BULK SAMPLE ANALYSIS FOR ASBESTOS IRS Environmental Dave Seyfert PO Box 15216 Spokane WA 99215-5216 MMhnd! PLM WWh rllewer.u,w At.'Adne P.10 PAGE 11 Project: Wart 0d project #-, 820 Laboratory No. B06.5210 B06-52tI B06-521' �I Sample ID No. 07 08 09 Semple Description .Joint Compound .joint Compound Joint Cornpttltitrj Sample Treatment TeasedlCruahed Dissolved Teased/Crushed Dissolved Tesiaed;Cru:.i,cd Homogeneous No Na No Layered Yes Yes Yes Fibrocus No No Yes Sample Color Off Whit@/Grey WhiWBrown White/BroN% n Asbestos Present Yes Yes Yes Asbestos Type and Chrysotile 1-2% Chrysotile 1-2% ' Chrysotile 2-3%.._ Percet tare L Chrysotile 2.. Amosire 3. C rocido(itc A. Other 2-3% Total % Asbestos 1-2% 1-2% Other Fibrous material 4 In sem le _ C*Psum 97-99% Gypsum 97-98% Gypsum 97-9815l Point <1 % Paint <1% Non -Fibrous Material: Paint Paint Other 100% Other 100% faint Not Anal •rcct; J UQU ArWY-MU: May 1 U. 2006 —,....Y—. v,. -.- , Mounteia Ltt watim LMvfsioe of Wunt & hupeatief& Labomtory Services. tnc. 11109 wortaMy to proper mrohsis mcihWs only and tAos no tcapatiikitity i. ;itnplc amwwwwd. WuneWs L.abmvftw4 Division of Movnt;is Iaepaetios a Lsbcmwy $an (=. Ine, 9922 & Monti mery, suite NI J, Spoknno WrAinstm 99206 t ` " 1 9115-1365 Rex (309) 922 13110. PLM has bean known 16 miss asbWW in It sr181111e1ee+ttaga of amplo. Thus tw"Ive or <I% PLM results should be toted with 01"r Rl.m nr TEM, Client h tapomibk. rnr smapk sepnr4f=, his apM msy oaiy be mPr-J,"d .n (til) with wtlrten nppnw! Lry ?-fcurnain t *t.;::�u: i�» Page 4 of 6 MAY 25 2006 15:32 PAGE.10 MAY -25-2006 04:09 PM Caystone Construction 1 509 468 5081 05/23/2006 10:11 5099283933 IRS ENVIRONMENTAL BULK SAMPLE ANALYSIS FOR ASBESTOS IRS Environmental Dave Seyiert PO Box 1521.6 Spokane WA "2M5216 Mcthn& Pb,tyb With IV --I— Cvwlwi— P. 11 PAGE 12 Project: WarGcid Project * 82( T.aboratoryNo. B06-5213 B06-5214 (, nMc n d11V 1 806-521; Sample ID No. 10 11 12 Sample Description Joint Compound Popcorn Attic Insulaiii-ii Sample Treomcnt T'eascd/Crushed Teased Teased Homogeneous Yes No YE$ Layered Nn yes y0 Fibrous Yes Yes Ves Sample Color Off White Off White Grey Asbestos Present Yes No No Asbestos Type and Chrysotile 1-2% N.D. N.D. Percentage 1. Chrysotile 2. Amosite 3. Crocidolite 4. Other 1-2% Nonc None _ y Total % Asbestos Other fibrous material Cellulose 3% Cellulose 97% In sample Non -Fibrous Material: Gypsum 98-99% Hinder/Filler 52% BinderiFiller 3% Foam 45% vete Amfyxm: may t U, LQUtf Ann"d Ry: Midi 1., MUM) Ummtsk LOMmInrim Divicine of Mm atnin Inque.6an A Laboratory Services, fee. limits werrnnty to proper mniyds methods ewly and takes nn resnnasr1,i11ty fa< "nnpla nrncl renaat, W-mstair. L-11%ftf-oriae. M -Mon ofMou:Vain Insratier p L:Saratary servlet,. Ina, 4927 R. Martmne+y, Srha N11. S!okw, wn.:klnet" 0e205 (P• )22-13*1 -fait (S09) 922-1320. Ai fit ha been kntrwn to miss ttebostos in a srnnl! patatalul a of ssttlplCa, 11ttls mplive nr cl % PIN tetnhs sltaild he tested with either SEN* TSM. Client is ttsWteible ror sample sepwitim, This report tapy m+ly bre P*MWwead is {till with written 2Wavol by Mountain Labe etories. Page 5 of 6 MAY 25 2006 15:33 PAGE.11 MAY -25-2006 04:10 PM Capstone Construction 1 509 468 5081 P_12 uoizaiZUUb 19:11 5099283933 IRS ENVIRONMENTAL PAGE 13 BULK SAMPLE ANALYSIS i+'OR ASBESTOS IRS Enviwrnmenftl Dave Seyfert PO Box 15216 Spokane WA 94215-5216 ur1Md- PT M With ni.n .. Project: Wariicld Pro W M: 8207 Y^I S...! al lout Laboratory No. B06-5216 B06-5217 Sample ID No. I3 14 Sample Description Gold/White Meige 12"x1:2" Sheet. Vinvl Floor Tile Sample Treatment Teased Teased/Crashed Dissolved Homogeneous No No Layered Yes Yes Fibrous Yes No Sample Color Oft' White/Wd off White/Clear Bei eJCyreen Asbestos Present Yes No Asbestus Type and Backing Only Floor Tile N.D. Percentage Chrysotile 5540% 1. Chrysotile INnstic N:D. 2. Amosite 3. Crocidolite 1 4. Other - Total % Asbestos 20-25% None other fibrous material Celhilme 20-250A in sample Vinyl -1544 Floor Tile Binder/Filler 20% Vinyl 401/6 Binder/Filier 60% Non -Fibrous Material: Mastic Not Analyzed.. Mastic Other 100% nwtC Analyren.- May IU -.1000 Mvnntaia Gbornaoria, l7ihrieioa of Mourktin TelpeotlM a_ 1,abor Wv Sdr+kea, frto, limiti vinmMy to proper 87alysh mefheda only 11101 lakes no YeTt tafbility (., ..irnple praaranov, Mountain Lobviralarks. Diwlsioe orMoanuin impea ioe & Laboratory Servieeit, for, 994.1 & Mr.orytreey, Suite 1113, Spokane w 20114lon 99206 ( �n 11922.1361 . st,T (309) 922-18An 111,M)m been knorn to twits aabe" inn mnnlh W61111UP of "WMICv, raw* negative or <1% PLM retults should be texted with oillWf Si 1,4 .r TEM. Client is rapoolihle for sample upomtkin.11U4 report may oniy he reptoduccd in fait ,nth wrinen npprovnt by Moumin Lebuntorics. Page 6 of MAY 25 2006 15:33 PAGE.12 MAY -25-2006 04:10 PM Capstone Construction 1 509 468 5081 UZV L.i! 200b 10:11 5099283933 IRS ENVIRONMENTAL BULK SAMPLE ANALYSTS FOR ASBESTOS TRS Environmental Dave Seyfert PO Box 15216 Spokane, WA 9921-4-5216 P.13 PAGE 14 Project: W2rneld Project #: 8207 Mt:thcd; PLM W"h UbmtsionStaining 101+1 Laboratory No, 1346-5319 Sample TD No. 8207-15 Sample Description Popcorn Sample Treadnertt Teased/Crushed Dissolved Homogeneous No havered Yes Fibrous Yes Sample Color Off White/Grey Asbestos Present No Asbestos Type and N.D. Percentage 1. Chrysatile i 2. Amosite air."fdd�ite, 4. fiOtber _ Total % A3bestos Nome other fibrous material Cellulose <M/6 in Sample py"psum 98% paitlt 0 0% 1 Tion -Fibrous Materiil: Paint Otho 104% Date Analyrtd- May 11 .2006 Analyzed Dy Hc)di .. tileCarti+ Momltata twhnralor M Di't-Wan ormawitain JWMgCtk+e i Labaratory .gervie�x, T+u. limitr wnfrx++ty m proper nnal�nis mctbade only and tnkoa no re9poneibilil7 rn..mnple ptaoan�M. Mattrttain Lahatatarin, Divtria* afMmattain }aafpacti°n d: LabotalarJ CRvtoa,, h1c.79Z1 & MnKpa+tey, Sttfte 1113, Rix+ku+a Washintrtan 9920ti 1 ••�+'+1922�13fiy - Rum 1309) 922-13141, FLM hat bap+ known Its laiy nbatox in it Lodi ponontnge of xomplat. Thur neaa live ar -!IU PLM rcathx sl:ottltl be r.^tp! tritF. 6'111111 Sl N., +r Tr_M Qlcnt it n nntihk lar smrple s�tnrnlinn, Mit apart a+ay only be tepral+kad to lbll witft wrikeh approval by Mm,nhua Caban+torica, Page 2 of 2 MAY 25 2006 15:34 PAGE.13 PROVIDE DIAGRAMS AND ENGINEERING LAYOUTS FOR ROOF TRUSSES, BEAMS AND FLOOR SYSTEMS PRIOR TO FRAMING INSPECTIONS CITY COPY THIS BUILDING' SUBJECT TO FIELD INSPECTION CORRECTIONS Spo'"u REMEWED FOR GO -D* COMPLIANCE SPOKANE`JALI.r"Y 13U(DIN DIVISION