2006, 04-26 Permit App: 06001464 Garage Addition Project Number: 06001464 Inv: 1 Application Date: 4/26/2006 Page 1 of 2
THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Project Information:
Permit Use: GARAGE ADDITION Contact: BILLEU,MICHAEL
Address: 13004 E 27TH AVE
C-S-Z: SPOKAN VALLEY 99206
Setbacks:Front Left: Right: Rear: Phone: (707)987-9696
Group Name:
Site Information: Project Name:
Plat Key: 001229 Name: HILLCREST ACRES 04TH ADD AMENDED District: F
Parcel Number: 45273.2211 Block: Lot:
SiteAddress: 13004 E 27TH AVE Owner:Name: BILLEU,MICHAEL
Address: 13004 E 27TH AVE
Location::CSV SPOKAN VALLEY 99206
Zoning: SFR
Water District: Hold: ❑
Area: .00 Acres Width: 0 Depth: 0 Right Of Way(ft): 0
Nbr of Bldgs: 1 Nbr of Dwellings: 1
Review Information: .
Review
Building Plan Review
Originally Released: 4/26/2006 By: amblake
Landuse/Zoning/HE Conditions ;" a' 4
Originally Released: 4/21/2006 By: HMStinson
Sewer Review x • ,
Originally Released: 4/26/2006 By: amblake
Permits: ;,�:r�mhi: � i�� .:,:u :vuan�, max,. Citi �er, Y.::�r ,�s�ua.
Operator: AMB Printed By: AMB Print Date: 4/26/2006
Project Number: 06001464 Inv: 1 Application Date: 4/21/2006 Page 1 of 2
THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Project Information:
nitA '.°-". .,. --_" "`v SBn;a bwwb:,^-.✓v: nre«IU,t:tihu.u-1F-,W,-`A.e k`3*f 'i 'MM uc&siNliY.u:.4"o.1bm'.. <. svx!,.:aG Mvae at.i CV.V Vnt,A;AOP?"?:'".W✓N a+•,R«:s" yew SSri .S;ai.
Permit Use: GARAGE ADDITION Contact: BILLEU,MICHAEL
Address: 13004 E 27TH AVE
C-S-Z: SPOKAN VALLEY 99206
Setbacks:Front Left: Right: Rear: Phone: (707)987-9696
Group Name:
Site Information: Project Name:
Plat Key: 001229 Name: HILLCREST ACRES 04TH ADD AMENDED District: F
Parcel Number: 45273.2211 Block: Lot:
SiteAddress: 13004 E 27TH AVE Owner:Name: BILLEU,MICHAEL
Address: 13004 E 27TH AVE
Location::CSV SPOKAN VALLEY 99206
Zoning: SFR
Water District: Hold: ❑
Area: .00 Acres Width: 0 Depth: 0 Right Of Way(ft): 0
Nbr of Bldgs: 1 Nbr of Dwellings: 1
Review Information:
Review
Building Plan Review Rel µ. .4,
Landuse/Zoning/HE Conditionsvve -AA
4
Sewer ReviewYn
plc a 7 r • •
Permits: x..x ". n, r r te"".. � a ,, � �.� n ., ,;. :x 'a : x , uai .,ate' ,w
Building Permit
Contractor: OWNER Firm: OWNER
Phone: (000)000-0000
Operator: AMB Printed By: AMB Print Date: 4/21/2006
Project Number: 06001464 Inv: 1 Application Date: 4/26/2006 Page 2 of 2
THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Building Permit
Contractor: OWNER Firm: OWNER
Phone: (000)000-0000
This Application: Total Project:
Description Grp Type Notes Sq Ft Valuation Sq Ft Valuation
GAR WOOD U-1 VB OWNER 0 $6,000.00 0 $6,000.00
Totals: 0 $6,000.00 0 $6,000.00
Item Description Units Unit Desc Fee Amount
RESIDENTIAL PERMIT FEE 1 SELECT $125.25
ACCESSORY PLANS REVIEW 1 SELECT $31.31
WSBC SURCHARGE 1 SELECT $4.50
Permit Total Fees: $161.06
Notes:
Payment Summary:
Permit Type Fee Amount Invoice Amount Amount Paid Amount Owing
Building Permit $161.06 $161.06 $0.00 $161.06
$161.06 $161.06 $0.00 $161.06
Disclaimer:
Submittal of this application certifies the owner(or person(s)authorized by the owner)has both examined and finds the information
contained within to be true and correct,and agrees that all provisions of laws and/or regulations governing this type of work will be
complied with. Subsequent issuance of a permit shall not be construed to be a permit for,or an approval of,any violation of any of
the provisions of the code or of any other state or local laws or ordinances.
Signature:
Operator: AMB Printed By: AMB Print Date: 4/26/2006
Project Number: 06001464 Inv: 1 Application Date: 4/21/2006 Page 2 of 2
• THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Payment Summary:
Disclaimer:
Submittal of this application certifies the owner(or person(s)authorized by the owner)has both examined and finds the information
contained within to be true and correct,and agrees that all provisions of laws and/or regulations governing this type of work will be
complied with. Subsequent issuance of a permit shall not be construed to be a permit for,or an approval of,any violation of any of
the provisions of the code or of any other state or local laws or ordinances.
Signature:
Operator: AMB Printed By: AMB Print Date: 4/21/2006
, � r c111111 l..-G111-GE
Siok` ie 11707 E Sprague.{eve, Suite l.061c, ,-_- PERMIT NUMBER: �L.=/elf
Valley
7e Spokane Valley,*Ai 9h6 G LC, F t v�1 IL 1 1 ))
� PERMIT FEE:
1! (509)680036F50 )680037 I1
Community Development www.spokanevaUer.ohr_.co_
/►PR 2C 2' . .
l) II f��``�- �
Residential Construction n' L�� Ij [E] 5)ew �o !uction ❑ Accessory Bldg
Permit Application J XAddition/Remodel o Deck
o Other:
SITE ADDRESS 13 '4 E:: ,� 7?� /iil tC Iii, L`'1,4..
�S d 7 o Z.Z/ a/e.v.e 1-i',..i..e�s r
ASSESSORS PARCEL NO: LEGAL DESCRIPTION: aat..1 1-724- D4.), �.arr l I
2-
Buildingowner M. ?k �tt1~ 1t���' /
� c GtGf ,�i��-- . ..:: �,:.:•� .Contractor, ... . _
Name: Name: T, 1 `�i� �e--2/
Address:/"435-6- 61,//ei r ',1C/- Address: I - c.,27
/ / to GY1 D'� /DCin' g F Zp .Ael , 99 2/
city: }�//f�frll �G��,N,� � 7 � � �/� � �`
Phone: 7D 7 gr79 f rax: 7/)7 7,3 2 T W Phone: q. ;-(Oi Fax: _..
Lic No: f q-7-0-/,�,[, Exp.Date:
` City Business Lic No:
Name: c--l4i 71/07,7„0/,,e,-t/
Phone: //— Jzz- (i" % _
Describe the scope of work in detail: Cost of Project: $ 6 dee
I\ll (90X.z2 ' 7® (c�AK&. OF G, 6_
**************The following MUST be complete: (write N/A if not applicable)**********************
HEIGHT TO PEAK: DIMENSIONS: #OF STORII,ES: TOTAL HABITABLE SPACE:
12` av -
2z tztO
MAIN FLOOR TO SQ. 211°FLOOR SQ. FTG: UNFIN BASEMENT SQ. FTG: IMPERVIOUS SURFACE
FTG: ovito AREA:
44 ne,¢ /VA
-
FINISHED BASEMENT GARAGE SQ. FTG: DECK/COV. PATIO SQ. FTG: 30% SLOPES ON
SQ. FTG: N 44142 A/0;i P'R�Q4P RTY: WA .
#OF BEDROOMS: CONSTRUCTION TYPE: HEAT SOURCE: =SEWS SEPTIC?
DISCLAIMER
The permitee verifies, acknowledges and agrees by their signature that 1) If this permit is for construction of or on a dwelling,the
dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The
signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done
in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of
Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal,state or
local laws,codes or ordinances.6) PI s or additional information may be required to be submitted,and subsequently approved before
this application can be processe
Signature
-;-41/2 . L��r,..---• Date 1' •--e*'
Method of Payment (Faxed permit applications will only be accepted with majo bankcard)
0 Cash 0 Check 0 Mastercard J VISA 0 Other
Bankcard#: Expires: _ t VIN#:
Authorized Signature:
REVISED 82512005
Spokane
ne
.0000Valley
11707 E Sprague Ave Suite 106 • Spokane Valley WA 99206
509.921.1000 ♦ Fax: 509.921.1008 • cityhall@spokanevalley.org
Residential Plan Submittal Minimums
❑ Completed Building & Mechanical application with: Accurate address, Parcel
Number and/or Legal Description, description of work, owner and contractor
information, signature, and date.
❑ Two sets of plans including Site Plan, elevations, floor plans, foundation plans
With details, roof plan, framing plans & details.
❑ Show the height of any proposed buildings or accessory structures.
❑ Floor plan for each floor Dimension to scale (minimum 1/8").and label each
Room (including sq. footage of house and garage on plans) Show each
level of existing house and square footage of any additions.
❑ All braced wall panel types: show locations and details of installation, including
engineered design.
❑ Egress windows: Provide at least one window or exterior door approved for
Emergency escape or rescue from a basement and in every room for sleeping.
❑ Smoke detector locations
❑ 22" X 30" attic access location
13 18" X 24" crawl space access:
❑ One-hour separation detail: between house and garage
❑ Floor framing details: Joist type, size, spacing and installation details
❑ Roof framing plan and details
❑ Furnace and hot water heater location.
. ❑ All header locations: type, size, and connections
•
❑ Foundation plan
❑ Insulation information
,
City of
SPOKANE VALLEY BUILDING DEPARTMENT
11707 E.Sprague Avenue#106,Spokane Valley,Washington 99206-Tel 509-688-0036-Fax 509-688-0037
Following is a typical cross-section for a residential garage. It may not represent the proposed project. If you are using this detail
as a portion of your plan submittal,please complete the requested information in the boxes provided on both sides of this sheet
This completed sheet,along with any additional Information needs to be submitted with your apHication and be on site at the time
of inspection.
PROTECTION AND OPENINGS BETWEEN NOTE:
DWEWNGS AND PRIVATE GARAGES SHALL HAVE: Diagonal wap bracing required on
each corner and every 25 feet of wall.
1)MATERIALS APPROVED FOR ONE HOUR FIRE Walls within 3 feet of a property line or
RESISTIVE CONSTRUCTION ON THE GARAGE SIDE: within 6 feet of a dwelling must be 1 hour .
•5/8"TYPE"X"GYP BOARD(HABITABLE SPACE ABOVE) rated. (5/8'type'X'gypsum sheathing
•1/2"GYP BOARD(RESIDENCE/ATTIC,FLOOR/CEIUNG) on both sides of wall). Openings are not
2)OPENINGS BETWEEN GARAGE AND RESIDENCE permitted in these walls. Garages over
SHALL BE EQUIPPED WITH SOLID WOOD DOOR,SOLID OR 3,000 sq.ft.require protection when
HONEYCOMB CORE STEEL DOORS NOT LESS THAN 1 3/8", closer than 20 feet to the property One.
OR 20 MINUTE FIRE RATED DOORS. Parapets may be required.
ALTERNATE FOUNDATION FOR
ACCESSORY BUILDINGS FROM ENGINEERED TRUSS
400 SQ.FT.TO 3000 SQ.FT. R SIZE AND SPACING
.2_x__ ___@,/,___•41‘0.C.
SECTION A-A
ROOFING MATERIAL
ROOFING PAPER
- 1111 .. ktio ��F '�___,..._____(00 -
SHEATHING
•. ' ,- *44,c-ew a-rigs DOUBLE TOP PLATE
_—1•3•••• ,. i'�' IIIII=III. d
11111 . ';.. •% • IIII IIII= WALL HEIGHT 7 T
II -11:111111,::.,- : 1111111 .TRUSSES
•i•
II =1116.- 24"MIN.
• • 44�a afy'`
(2)iF4 REBAR
+::% WALL SHEATHING
kir--I 2x 4 @ !4:: O.C.
SIDING
PRESSURE TREATED
SOLE PLATE
•, .81 •'a . ,., . ..:t —)- , �.. 3-112"CONCRETE SLAB
= �< • •• ' • • 6"MIN. 6"MIN.
IF `
mum= ligigirget
=11111=1111);. • 4. • I Alai— ®1111 P=i -�� ANCIRR BOLTS
119,. -. - .alii.T" 24"MIN. 24"MIN. - 1,--1111 �
6 MIN. ; 12" MIN.
I .--., • •• (7"INTO CONCRETE)
6' .C.OR APPROVED
1--12"--1 (2)#4 REBAR 6"x12" ANCHOR INSTALLED
FOOTING PER MANUFACTURER.
FOUNDATION PLAN
PLEASE COMPLETE THE FOLLOWING INFORMATION AND ADD ON THE DRAWING BELOW.
BUILDING DIMENSIONS: 2O`,1-.2 a:
GARAGE OPENING AND HEADER SIZE: 14' / 0t ,P- -2.1-co Y.ti 4
INDICATE THE LOCATION AND SIZE OF ALL WINDOWS AND DOORS ON THE PLAN.
WIDTH cXe,
RIDGE UNE -
` uct7
I- TONMETE EICONPY"Iuii Jima 414-A-.I(i)---- - -
FOUNDATION WALLS - 3000 PSI
I
SLABS, GARAGES, CARPORT
& PORCHES•3500# PSI I
ALL FOOTINGS MUST BE CON"VIJOUS , I
F' 1
DWE , A
u A
1)MATERIALS APPROVED FOR ONE HOUR FRE RESISTIVE 1
CONSTRUCTION ON THE GARAGE Sir, !
l
�� ism ,
_ ❑ 5/8"TYPE"X"GYP BOARD1 hAB1 ABi-E SF ACE ABOVt-!UR
� 0 1/2"GYP BOARD(RESIDE!J,'E.AI TIC,FLOOR/CEIIING)
z 1 2)OPENINGS BETWEEN GARAt AND RESIDE CE SHALL BE I
W X EQUIPPED WITH SOLID WOOD DOOR,SOLID 0�HONEYCOMB CURE E
J STEEL DOORS NOT LESS THAN 1 3/8',OR 20 MINUTE FIRE RATED !
DOORS. ' 1
r Min. 4 ft Brace Wall Panel per R602.10.3 & R602.10.4 I
Min. 2 ft 8 in. Alternate Brace Wall Panel per R602.10.6
Min. 16, 18 or 20 in. APA Portal Frame Bracing
Engineered Shear Wall Bracing .
C i I
l I
L -i I
4- a- ,1x-t o x-r I
Please note that while every effort is made to assure the accuracy of the information contained in this brochure is
not warranted for accuracy.This document is not intended to address all aspects or regulatory requirements for a
project and should serve as a starting point for your investigation. For detailed information on a particular project,
permit,or code requirement refer directly to applicable file and/or code/regulatory documents or contact the
appropriate division.
FIGURE 1
CONSTRUCTION DETAILS FOR THE APA NARROW WALL BRACING METHOD WITHOUT HOLD-DOWNS
OVER CONCRETE OR MASONRY BLOCK FOUNDATION
Outside Elevation
Max.
height
10'
Extent of header (Two braced wall segments)
Extent of header (One braced wall segment)
2' to 18' (finished width)
Fasten sheathing to header with
8d common nails in 3" grid
pattern as shown and 3" o.c. in
all framing (studs and sills) typ.
Top plate
continuity is
required per
R602.3.2
•
•
1000 Ib header -to -jack -stud strap
on both sides of opening
(Install on backside as shown on
Side Elevation, Ref. No. LSTA24)
Min. (2) 2x4 typ.
If panel splice is needed it shall
occur within 24" of mid -height.
Blocking is not required.
l4i
Min. width based on 6:1
leo height -to -width ratio: For
example:16" min. for 8' height
Braced wall
............:..
segment per
R602.10.5
No. of
jack studs
per table
R502.5(1&2)
t 3
rpm
bL
Min. 2"x2"x3/16" plate washer
Anchor bolt per R403.1.6 Typ.
Foundation per code
Side Elevation
Sheathing filler
if needed
16d sinker
nails in 2 rows
@3"o.c.
1000 Ib header -
to -jack -stud strap
on both sides
of opening (Ref.
No. LSTA24)
3/8" min.
thickness wood
structural panel
sheathing
Not to scale
•
i.'.
A2: 1
.................,,r....7
74 C. CO
)'• 4_1
7,...
741 1 4
,..r)
-.
-
_
i .
_
_ S'_
V[1 " —I
7
4 Y.
.k TA cl.
,. -\ •,, .. )
o ;.
- . ' 1 -
zv, P
1 ik)
vs PLANNING DEPT. APPROVED
i • ,
BYId
• ,Mr. f......n...1 .. —.0.,M g., AI a
.':
- .
DATE: lAtA6 .
% pe u_otii
:.:
i CUAA-Db14Xcelf lea
.
1 .2/
re u'o
�tvL?
ALL FOOTINGS MUST BE CONTINUOUS
;r—
(�l y ;a.•` :.mow': � �-
O
1) MATERIALS�APPROVED FOR ONE HOUR FIRE RESISTIVE
CONSTRUCTION ON THE GARAGE SIDE:
0 5/8" TYPE "X" GYP BOARD (HABITABLE SPACE ABOVE) OR
0 1/2" GYP BOARD (RESIDENCE/ATTIC, FLOOR/CEILING)
2 OPENINGS BETWEEN GARAGE AND RESIDENCE SHALL BE
E�DIPPED WITH SOLID WOOD DOOR. SOLID OR HONEYCOMB CORE
STEEL DOORS NOT LESS THAN 13/8". OR 20 MINUTE FIRE RATED
0`
'?e'
Cov AL-lum mpt 4- -
vJA ALL
��STAh�LG
tFt7tS UG A-0- GdJe4ACt7
'J714C- W4 LL *744-4DL4,10- e-0
t fT f /-"A t. ccaA- I dr�
IF NoN 6e*Awr. WA«
_
r
rJ
O
1) MATERIALS�APPROVED FOR ONE HOUR FIRE RESISTIVE
CONSTRUCTION ON THE GARAGE SIDE:
0 5/8" TYPE "X" GYP BOARD (HABITABLE SPACE ABOVE) OR
0 1/2" GYP BOARD (RESIDENCE/ATTIC, FLOOR/CEILING)
2 OPENINGS BETWEEN GARAGE AND RESIDENCE SHALL BE
E�DIPPED WITH SOLID WOOD DOOR. SOLID OR HONEYCOMB CORE
STEEL DOORS NOT LESS THAN 13/8". OR 20 MINUTE FIRE RATED
0`
'?e'
Cov AL-lum mpt 4- -
vJA ALL
��STAh�LG
tFt7tS UG A-0- GdJe4ACt7
'J714C- W4 LL *744-4DL4,10- e-0
t fT f /-"A t. ccaA- I dr�
7
PROVIDE DIAGRAMS AND
ENGINEERING LAYOUTS FOR
ROOF TRUSSES, BEAMS AND
FLOOR SYSTEMS PRIOR TO FRAMING
INSPECTIONS
CITY COPY
SUBJECT
THIS BUILDING
TO FIELD INSPECTION CORRECTIONS
REVIEWED FOR CO'a E C•MPLIANCE