2006, 10-02 Permit App: 06003913 BathroomProject Number: 06003913 Inv: I Application Date: 10/2/2006 Page 1 of 2
THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Project Information:
,Awa ,n.n'M �
Permit Use: ADDING BATHROOM TO BASEMENT Contact: ATENCIO, JEREMIAH & AMBER
Address: 11415 E 28TH AVE
C - S - Z: SPOKANE VALLEY, WA 99206
Setbacks: Front Left: Right: Rear: Phone: (509) 892-2089
Group Name:
Site Information: Project Name
,, ,. .,. „�.«.'�+���i�h���e"��"1'�G ,,.,': "`?'k 0�i, p�� '••.' :a.?"�t�.�".W���i�+.r. _.: ,.. .,, ....-...^.«%,�..'ryi,'I�u'#II q��F`f`v,'ef�;':
Plat Key: 001393 Name: KOKOMO TOWNSITE (FEES) District: Sout
Parcel Number: 45283.4007 Block: Lot:
SiteAddress: 11415 E 28TH AVE Owner: Name: ATENCIO, JEREMIAH & AMBER
Address: 11415 E 28TH AVE
Location:: CSV SPOKANE VALLEY, WA 99206
Zoning: SFR
Water District:
Area: .00 Acres Width: 0
Nbr of Bldgs: 1 Nbr of Dwellings: 1
Review Information: ,
Review
Flood Plain
Originally Released:
Building Plan Review
Hold: ❑
Depth: 0 Right Of Way (ft): 0
Released By:
10/2/2006 By: amblake
Released By:
Originally Released: 9/29/2006 By: TMELBOU
Sewer Review Released By:
Originally Released: 10/2/2006 By: amblake
Permits:
Operator: AMB Printed By: AMB Print Date: 10/2/2006
Project Number: 06003913 Inv: I Application Date: 10/2/2006
THIS'IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Building Permit - _ - -- -
Contractor: OWNER Firm: OWNER
Phone: (000)000-0000
This Application: Total Project:
Description Grp Type Notes SQ Ft Valuation SQ Ft Valuation
BASEMENT R R-3 VB ADD 0 $2,000.00 0 $2,000.00
BATHROO
M
Notes:
Page 2 of 2
Payment Summary
Totals:
0 $2,000.00
0 $2,000.00
Item Description
Units
Unit Desc
Fee Amount
RESIDENTIAL PERMIT FEE
1
SELECT
$69.25
WSBC SURCHARGE
1
SELECT
$4.50
SF PLNS RVW < 7999 SQ FT
1
SELECT
$27.70
$131.45
Permit Total Fees:
$101.45
$131.45
Plumbing Permit
Contractor: OWNER
Firm: OWNER
Phone: (000)000-0000
Item Description
Units
Unit Desc
Fee Amount
TOILETS/BIDETS
I
NUMBER OF
$6.00
SINKS
2
NUMBER OF
$12.00
SHOWERS
1
NUMBER OF
$6.00
SEWAGE EJECTOR
1
NUMBER OF
$6.00
Permit Total Fees:
$30.00
Notes:
Page 2 of 2
Payment Summary
Permit Tyne
Fee Amount
Invoice Amount
Amount Paid
Amount Owing
Building Permit
$101.45
$101.45
$0.00
$101.45
Plumbing Permit
$30.00
$30.00
$0.00
$30.00
$131.45
$131.45
$0.00
$131.45
Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information
contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be
complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of
the provisions of the code or of any other state or local laws or ordinances.
Signature:
Operator: AMB Printed By: AMB Print Date: 10/2/2006
Project Number: 06003913 Inv: 1 Application Date: 9/29/2006 Page 1 of 2
THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Proiect Information:
Permit Use: ADDING BATHROOM TO BASEMENT Contact: ATENCIO, JEREMIAH & AMBER
Address: 11415 E 28TH AVE
C - S - Z: SPOKANE VALLEY, WA 99206
Setbacks: Front Left: Right: Rear: Phone: (509) 892-2089
Group Name:
Site Information: Project Name:
Plat Key: 001393 Name: KOKOMO TOWNSITE (FEES) District: Sout
Parcel Number: 45283.4007 Block: Lot:
SiteAddress: 11415 E 28TH AVE Owner: Name: ATENCIO, JEREMIAH & AMBER
Address: 11415 E 28TH AVE
Location:: CSV SPOKANE VALLEY, WA 99206
Zoning: SFR
Water District: Hold: ❑
Area: .00 Acres Width: 0 Depth: 0 Right Of Way (ft): 0
Nbr of Bldgs: 1 Nbr of Dwellings: 1
Review Information:.
Review
Flood Plain uAtPa�P.t u.�•
Building Plan Review
Sewer Review
Permits:
Building Permit
Contractor: OWNER Firm: OWNER
Phone: (000) 000-0000
Contractor: OWNER
Operator: AMB Printed By: AMB
Plumbing Permit
Firm: OWNER
Phone: (000) 000-0000
Print Date: 9/29/2006
crn ,x
Permit Center
Spol�ane 11707 E Sprague � , Suite 106 'LQQ6 PERMIT NUMBER:
Spokane Valley, WA992060 ww PERMIT FEE:
x,,00 Valley (509)688-0036 FAX: (509)6037
Community Development www.s okanevallev.1
Residential Construction ❑ New Construction ❑ Accessory Bldg
Permit Application R Addition/Remodel ❑ Deck
❑ Other:
SITE ADDRESS )NIS C . 2-vL AVE Sf-b r Aor. vAaE/ 11 wL,
ASSESSORS PARCEL NO: LEGAL DESCRIPTION:
Building Owner:
Name:�Enn�q i rc AiEntciO
Address: ) j c4 G Z
City: 5 dkp".�e v/a _L6 y State: tAfA Zip: M
Phone: s O 9_ ScI 2-ZQ 6, Fax:
Contact Person
Name: r3Ex, -TF-Nc.i o
Phone: S o°f - 9 7'/ - -S 7 / v
Describe the scope of work in detail:
Contractor:
Name:
Address:
City: State: Zip:
Phone: Fax:
Contractor Lic No: Exp Date:
City Business Lic. No:
Cost of Project: $ 2ooa ad
-h
jam: _.btY -+ i - h. &A
**************The following MUST be complete: (write N/A if not applicable)**********************
HEIGHT TO PEAK:
DIMENSIONS:
# OF STORIES: u/A
TOTAL HABITABLE SPACE:
MAIN FLOOR TO SQ.
2 NU FLOOR SQ. FTG:
UNFIN BASEMENT SQ. FTG:
IMPERVIOUS SURFACE
FTG:
AREA:
FINISHED BASEMENT
GARAGE SQ. FTG:
DECK/COV. PATIO SQ. FTG:
30% SLOPES ON
SQ. FTG:
PROPERTY:
# OF BEDROOMS:
CONSTRUCTION TYPE:
HEAT SOURCE:
&AS
SEWER OR SEPTIC?
SEwE�z
The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling, the
dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The
signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done
in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of
Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or
local laws, codes or ordinances. 6) Plans or additional information may be required to be submitted, and subsequently approved before
this application can be processed.
Signature L.
Method of Payment:
❑ Cash ❑ Check
Bankcard #:
Authorized Signature:
REVISED 8/25/2005
❑ Mastercard
Expires:
Date
1/2-
E]
z
❑ VISA
VIN#:
G2404.6 (301.10) Wind resistance. Appliances and supports
that are exposed to wind shall be designed and installed to resist
the wind pressures determined in accordance with this code.
G2404.7 (301.11) Flood hazard. For structures located in
flood hazard areas, the appliance, equipment and system instal-
lations regulated by this code shall be located at or above the
design flood elevation and shall comply with the
flood -resistant construction requirements of Section R323.
Exception: The appliance, equipment and system installa-
tions regulated by this code are permitted to be located below
the design flood elevation provided that they are designed and
installed to prevent water from entering or accumulating
within the components and to resist hydrostatic and hydrody-
namic loads and stresses, including the effects,of buoyancy,
during the occurrence of flooding to the design flood eleva-
tion and shall comply with the flood -resistant construction re-
quirements of Section R323.
G2404.8 (301.12) Seismic resistance. When earthquake loads
are applicable in accordance with this code, the supports shall
be designed and installed for the seismic forces in accordance
with this code.
G2404.9.(301.14) Rodent proofing. Buildings or structures
and the walls enclosing habitable or occupiable rooms and
spaces in which persons live, sleep or work, or in which feed,
food or foodstuffs are stored, prepared, processed, served or
sold, shall be constructed to protect against the entry of rodents.
SECTION G2405 (302)
STRUCTURAL SAFETY
G2405.1 (302.1) Structural safety. The building shall not be
weakened by the installation of any gas piping. In the process of
installing or repairing any gas piping, the finished floors, walls,
ceilings, tile work or any other part of the building or premises
which are required to be changed or replaced shall be left in a
safe structural condition in accordance with the requirements
of this code.
G2405.2 (302.4) Alterations to trusses. Truss members and
components shall not be cut, drilled, notched, spliced or other-
wise altered in any way without the written concurrence and
approval of a registered design professional. Alterations result-
ing in the addition of loads to any member (e.g., HVAC equip-
ment, water heaters) shall not be permitted without verification
that the truss is capable of supporting such additional loading.
SECTION G2406 (303)
APPLIANCE LOCATION
G2406.1(303.1) General. Appliances shall be located as re-
quired by this section, specific requirements elsewhere in
this code and the conditions of the equipment and appliance
listing.
G2406.2 (303.3) Prohibited locations. Appliances shall not
be located in, or obtain combustion air from, any of the follow-
ing rooms or spaces:
1. Sleeping rooms.
2. Bathrooms.
FUEL GAS
3. Toilet rooms.
4. Storage closets.
Exceptions:
1. Direct -vent appliances that obtain all combustion air
directly from the outdoors. _
2. Vented room heaters, wall furnaces, vented decora-
tive appliances and decorative appliances for installa-
tion in vented solid fuel -burning fireplaces, provided
that the room meets the required volume criteria of
Section G2407.5.
3. A single wall -mounted unvented room heater
equipped with an oxygen depletion safety shutoff sys-
tem and installed in a bathroom, provided that the in-
put rating does not exceed 6,000 Btu/h (1.76kW) and
the bathroom meets the required volume criteria of
Section G2407.5.
4. A single wall -mounted unvented room heater
equipped with an oxygen depletion safety shutoff sys-
tem and installed in a bedroom, provided that the in-
put rating does not exceed 10,000 Btu/h (2.93 kW)
and the bedroom meets the required volume criteria of
Section G2407.5.
5. Appliances installed in an enclosure in which all com-
bustion air is taken from the outdoors, in accordance
with Section G2407.6. Access to such enclosure shall
be through a solid weather-stripped door, equipped
with an approved self-closing device.
G2406.3 (303.6) Outdoor locations. Equipment installed in
outdoor locations shall be either listed for outdoor installation
or provided with protection from outdoor environmental fac-
tors that influence the operability, durability and safety of the
equipment.
SECTION G2407 (304)
COMBUSTION, VENTILATION AND DILUTION AIR
G2407.1(304.1) General. Air for combustion, ventilation and
dilution of flue gases for gas utilization equipment installed in
buildings shall be provided by application of one of the meth-
ods prescribed in Sections G2407.5 through G2407.9. Where
the requirements of Section G2407.5 are not met, outdoor air
shall be introduced in accordance with one of the methods pre-
scribed in Sections G2407.6 through G2407.9. Direct -vent ap-
pliances, gas appliances of other than natural draft design and
vented gas appliances other than Category I shall be provided
with combustion, ventilation and dilution air in accordance
with the equipment manufacturer's instructions.
Exception: Type 1 clothes dryers that are provided with
makeup air in accordance with Section G2439.4.
G2407.2 (304.2) Appliance/equipment location. Equipment
shall be located so as not to interfere with proper circulation of
combustion, ventilation and dilution air.
G2407.3 (304.3) Draft hood/regulator location. Where used,
a draft hood or a barometric draft regulator shall be installed in
the same room or enclosure as the equipment served so as to
prevent any difference in pressure between the hood or regula-
tor and the combustion air supply.
2003 INTERNATIONAL RESIDENTIAL CODE® 339
8-C?rv;S
F<. ZNR cF Wsh-
bEiiwr
WHEN INTERIOR ALTERATIONS, REPAIRS OR ADDITIONS
REQUIRING A PERMIT OCCUR, OR WHEN ONE OR MORE
SLEEPING ROOMS ARE ADDED OR CREATED IN EXISTING
DWELLINGS, THE DWELLING UNIT SHALL BE PROVIDED
WITH SMOKE ALARMS LOCATED AS REQUIRED FOR NEW
DWELLINGS.
dialv l I l\dCS11 ON 'DR
gt7t7C-6 (9)
9L L8 -Z6 (9) :xo
L
7,
r/
ainii.•11•11m.
U C 508.2 — Water heaters require anchoring or
strapping at upper and lower one third points to prevent
horizontal displacement during earthquakes. Strapping
shall be a minimum of 4 inches above controls.
w
r444 -.S.
VIR.1111.k
tAAA,
tok-r-
Fu RAJA
PROVIDE DIAGRAMS AND
ENGINEERING LAYOUTS FOR
ROOF TRUSSES, BEAMS AND
FLOOR SYS;EMS PRIOR TO FRAMING
IN:;P'L CTIONS
CITY COPY
THIS BUILDING SUBJECT
TO FIELD INSPECTION CORRECTIONS
. - Sia€',.: • -
REVIEWED, FOR ;GDE COMPLIANCE
irSPOKA!'E ,, ; ...'601.D G DIVISION