2010, 05-04 Permit App: 10000559 Garage, Project Number: 10000559 Inv: I Application Date: 5/4/2010 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Proiect Information: Permit Use: 20 X 24 GARAGE Contact: BLY, JOHN PAUL & DEE A Address: 11107 E 28TH AVE C - S - Z: SPOKANE, WA 99206-7110 Setbacks: Front Left: Right: Rear: Phone: (509) 922-4858 Group Name: Site Information Project Name Plat Key: 001393 Name: KOKOMO TOWNSITE (FEES) District: Sout Parcel Number: 45283.3911 Block: SiteAddress: 11107 E 28TH AVE Location:: CSV Zoning: R-3 SF Res District Water District: 007 MODEL Area: 14,300 Sq Ft Width: 110 Nbr of Bldgs: 0 Nbr of Dwellings: 1 Lot: Owner: Name: BLY, JOHN PAUL & DEE A Address: 11107 E 28TH AVE SPOKANE, WA 99206-7110 Hold: ❑ Depth: 130 Right Of Way (ft): 70 Review Information: Review Building Plan Review Originally Released: Driveway/Approach Released By: 3/4/2010 By: tmelbourn A*taUA�6� Released By: %V 170 r, REQUIRED Originally Released: 5/4/2010 By: TMELBOU Landuse/Zoning/HE Conditions Released By: As per SVMC 19.40.020B All residential driveways shall be paved... with an approved hard surface material. Originally Released: 3/3/2010 By: tschmidt Permits: Operator: JD Printed By: jmm Print Date: 5/4/2010 Page 1 of 2 Project Number: 10000559 Inv: I Date: 5/4/2010 Page 2 of 2 � Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Building Permit Contractor: OWNER Firm: OWNER Phone: (000) 000-0000 Permit Type Fee Amount This Application: Total Project: Description Grp Type Notes Sg Ft Valuation SQ Ft Valuation GAR WOOD U-1 VB $182.25 480 $9,120.00 480 $9,120.00 $231.06 Totals: 480 $9,120.00 480 $9,120.00 Item Description Units Unit Desc Fee Amount RESIDENTIAL PERMIT FEE 1 SELECT $181.25 ACCESSORY PLANS REVIEW 1 SELECT $45.31 WSBCC SURCHARGE 1 SELECT $4.50 Permit Total Fees: $231.06 Notes.,.,....x��.>. _ .,�._ ._..._... APPROACH PERMIT REQUIRED As per SVMC 19.40.020B All residential driveways shall be paved... with an approved hard surface material. Payment Summary: Permit Type Fee Amount Invoice Amount Amount Paid Amount Owing Building Permit $231.06 $231.06 $48.81 $182.25 T • 1 $231.06 $231.06 $48.81 $182.25 Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature• Operator: JD Printed By: jmm Print Date: 5/4/2010 Permit Center ` OF 11703 E Sprague Ave, Suite B-3 PERMIT NUMBER: ' J Spcmokane Tq Spokane Valley, WA 99206 PERMIT FEE: � Valle (509)688-0036 FAX: (509)688-0037 Y, www.Mokanevalley.org Community Development Residential Construction ❑ New Construction Accessory Bldg Permit Application ❑ Addition/Remodel /❑ Deck ❑ Other: __ - ---- _.- ----� SITE ADDRESS: ASSESSORS PARCEL NO: LEGAL DESCRIPTION: Building Owner: Name - --a,,4 Address`. Ci State: ZEll Phone: x: Contact Person Nam Phone: t,:�>-'I cj Describe the scope of work in detail: Proposed Use: RE(A Contractor: t Name: C—h— ubmittat Address: TOTAL HABITABLE SPACE: City: State: Zip: Phone: Fax: Contractor Lic No: Exp Date: City Business Lic. No: IMPERVIOUS SURFACE Cost of Project: $ r S vti t-) 1 **************Tha fnllnwina 1ViT1CT he rmmplete: (write N/A if not aDDlicable)********************** HEIGHT TO PEAK: DIMENSIONS: # OF STORIES: TOTAL HABITABLE SPACE: -")-o 'S- MAIN FLOOR TO SQ. 2 FLOOR SQ. FTG: UNFIN BASEMENT SQ. FTG: IMPERVIOUS SURFACE FTG: AREA: FINISHED BASEMENT GARAiPE SQ. FTG: DECK/COV. PATIO SQ. FTG: 30% SLOPES ON SQ. FTG: a t� ERTY: # OF BEDROOMS: DNSTRUCT ON TYPE: HEAT SOURCE: SEWE OR SEPTIC? The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling, the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or local laws, codes or ordinances. 6) Plans or additional information may be required to be submitted, and subsequently approved before this application can be proc sed. \ DATE: SIGNATU 1't, 0 Method of Payment: ❑ Cash Check ❑ Mastercard ❑ VISA Bankcard #: Expires: VIN#: Authorized Signature: REVISED 2/15/07 m RESIDENTIAL CHECK LIST DIRECTIONS: Place a check mark in box next to each document required for complete submittal. ❑ SITE PLAN ❑ Property lines and dimensions ❑ Setbacks to property lines ❑ Direction arrow pointing North and orientation to streets ❑ Distance between buildings ❑ Proposed/existing buildings (footprint and dimensions) ❑ Right of way/easement location & sizes ❑ Utilities, septic tank/drain field locations and distances ❑ Driveway approach size and location BUILDING PLANS (3 SETS) (minimum 1/8 inch scale or completely dimensioned) ❑ Elevations (Front/Rear/Sides) with roof peak and wall height including basement: ❑ Foundation Plan (crawispace, basement or slab on grade): ❑ Footing sizes and locations ❑ Supporting wood cripple walls or beams ❑ Perimeter concrete foundation wall sizes ❑ Thickened concrete pads supporting ❑ Crawlspace ventilation beams or girder trusses ❑ Floor Plan of each level (finished or unfinished) with dimensions: ❑ Floor Joist direction, size and spacing ❑ Window and door location and sizes ❑ Header, beam or concrete lintel sizes ❑ Window well locations if applicable ❑ Brace wall panel locations ❑ Room usage labels ❑ Water heater and furnace locations ❑ Smoke detector locations ❑ Exhaust fan locations ❑ Attic and crawl space access locations ❑ Deck or concrete patio sizes and locations ❑ Fire Wall construction ❑ Roof Plan: ❑ Engineered truss direction and spacing ❑ Rafter and over frame direction, size and spacing ❑ Wall Section Detail including: Roof ❑ Slope/ roofing material/ underlayment/ ice dam protection ❑ Sheathing size and type Ceiling ❑ Joist size and spacing Wall ❑ Height/ top plate/ stud size and spacing/ sole plate ❑ Exterior sheathing size and type Floor ❑ Joist size and spacing Foundation Wall ❑ Concrete or Masonry unit width ❑ Earth to wood separation distance Footing ❑ Size Radon ❑ Passive system with Emil vapor barrier Miscellaneous Construction Details ❑ Deck: ❑ Floor plan/ side view/ dimensions ❑ Floor Joist/ decking direction, size and spacing 0 Stairway tread rise & run and nosing ❑ Ridge, eave and valley lines ❑ Beam and girder size and location ❑ Truss or rafter size, spacing & connection ❑ Attic insulation/ air space baffle/ ventilation ❑ Size of ceiling gypsum wall board ❑ Siding/ exterior house wrap/ anchor bolts ❑ Insulation, vapor barrier, gypsum wall board ❑ Sheathing or concrete floor size/ insulation ❑ Footing bottom to finished ground level depth ❑ Horizontal & vertical reinforcement if any ❑ Reinforcement if any ❑ Active system with 6 mil vapor barrier ❑ Footings/ post/ and beam size and locations 0 Handrail / Guard height & spacing 00010� Sp®kane jValleyx Community Development Building Division 11703 E Sprague Ave Suite B3 Spokane valley WA 99206 Inspection Request Line: 509-688-0054 All inspections are scheduled through this line THIS CARD MUST BE POSTED ON THE JOB SITE AT THE TIME OF INSPECTION ***Inspection requests must be scheduled before 7:00 am the morning of the desired date of inspection*** To call in an inspection request: 1. Call the Inspection Request line: 509-688-0054 2. When prompted, indicate your inspection area as checked below: EAST AREA Press 1" ® SOUTH AREA Press "2" NORTH AREA Press "T' 3. Leave the following information: Project number: 0-- Project Address: l// b i c, Z 8 -JJ— Type of Inspection Your phone number Your preference for AM or PM inspection time *** Special arrangements for access *** The inspector will make every effort to accommodate your preference. Depending on workload, the inspector cannot guarantee AM or PM inspection. 4. To speak directly with the inspector, please call their direct line between 7:00 am -7:30 am. Spokane ..jValleyk Community Development Building Division 11703 E Sprague Ave Suite B3 Spokane Valley WA 99206 PROJECT INSPECTION RECORD Inspection Request Line: 509-688-0054 All inspections are scheduled through this line THIS CARD MUST BE POSTED ON THE JOB SITE AT THE TIME OF INSPECTION PROJECT NO: 10- vsS'� PROJECT ADDRESS: /// 0 -7 L Z Y4 - Inspection Date Notes Corrections Left? Approved Inspector SETBACKS FOOTINGS REINFORCEMENT UNDERGROUND RADON DRAIN/WASTE/VENT WATER PIPING DUCT WORK GAS PIPING HOOD DUCT HOLDDOWNS SHEAR/BRACE WALL SHEATHING FRAMING INSULATION CEILING GRID FIREWALL/GWB FIRE PROTECTION HOOD/DUCT APPROACH/ROW OTHER REQ: FINAL: FIRE FINAL: PLANNING FINAL: ENGINEERING FINAL: BUILDING a�aiat"��I yi4 t; SCITY p6lfane ,,;oOValle ° Y For City Use Only PLUS Project Number 1 - Project Address 11703 E Sprague Ave Suite B-3 ♦ Spokane Valley WA 99206 509.688.0036 ♦ Fax: 509.688.0037 ♦ permitcenter@spokanevalley.org As part of our on-going commitment to customer service during the review process of your project application, we are providing you with a TARGET DATE for the initial technical application review. If for any reason we cannot meet this date, we will contact you with a revised target date. Your application review TARGET DATE is The TARGET DATE is the date we estimate your project application will have had its initial technical review. It is not the date for approval or permit issuance. Tips for a Smoother Project Application Review ➢ Submit complete, accurate plans and documents. Extra time may be required for re -submittals as project application reviewers work on multiple applications and it may be several days before they can look at your new or revised information. ➢ Designate a specific contact person to communicate with the City. While the person designated as the applicant's contact person with the City can be changed, one individual with the expertise for dealing with reviewer comments would be the best choice for the entire review process. ➢ Call staff regarding the status of your project only after the target date shown at the top of the page. Although you should be contacted on or by the target date, please feel free to contact us if you haven't heardfrom us by your target date. Staff may contact you before the target date if the initial review is complete. By following this procedure, you will save time and allow the reviewers to complete the work more expeditiously. Steps in the Permit Process 1. Counter Complete. Your application has been accepted as counter complete. This means all of the required documents, as indicated on your Pre -Application Checklist have been submitted or have been approved for deferred submittal. This does not prevent technical staff from requesting additional information as a result of their technical review. 2. Quality Check. The next step in the process is a quality check to make sure that the application is reviewable and free from substantive flaws that would prevent technical staff from completing the technical review once it started. When this step is complete, your application will be routed to the appropriate staff and remain in their review queue until it comes up for review. 3. Technical Compliance. Once an application is administratively complete, it is routed to technical staff for compliance review. Depending on the type of project, technical staff may include multiple reviewers. You should be contacted by phone, fax, email, or mail by your TARGET DATE once the initial technical compliance review is complete. 4. Permit Issuance. When the technical compliance review of the application is complete, including any subsequent re - submittals, each reviewer will approve their section of the application and route it to the Permit Center. When all sections of the application are received, a Permit Specialist will process the application and contact the person specified on your application for permit pick-up. Information regarding fees and pre -construction meetings (if required) will be provided by the Permit Specialist at that time. WHITE—APPLICANT PINK — BUILDING FILE REV 9/07 WASHINGTON STATE ENERGY CODE TABLE 6-2 PRESCRIPTIVE REQUIREMENT So" FOR GROUP R OCCUPANCY CLIMATE ZONE 2 * Reference Case 0. Nominal R -values are for wood frame assemblies only or assemblies built in accordance with Section 601.1. 1. Minimum requirements for each option listed. For example, if a proposed design has a glazing ratio to the conditioned floor area of 13%, it shall comply with all of the requirements of the 15% glazing option (or higher). Proposed designs which cannot meet the specific requirements of a listed option above may calculate compliance by Chapters 4 or 5 of this Code. 2. Requirement applies to all ceilings except single rafter or joist vaulted ceilings complying with note 3. 'Adv' denotes Advanced Framed Ceiling. 3. Requirement applicable only to single rafter or joist vaulted ceilings where both (a) the distance between the top of the ceiling and the underside of the roof sheathing is less than 12 inches and (b) there is a minimum 1 -inch vented airspace above the insulation. Other single rafter or joist vaulted ceilings shall comply with the "ceiling" requirements. This option is limited to 500 square feet of ceiling area for any one dwelling unit. 4. Below grade walls shall be insulated either on the exterior to a minimum level of R-12, or on the interior to the same level as walls above grade. Exterior insulation installed on below grade walls shall be a water resistant material, manufactured for its intended use, and installed according to the manufacturer's specifications. See Section 602.2. 5. Floors over crawl spaces or exposed to ambient air conditions. 6. Required slab perimeter insulation shall be a water resistant material, manufactured for its intended use, and installed according to manufacturer's specifications. See Section 602.4. 7. Int. denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation. 8. This wall insulation requirement denotes R-19 wall cavity insulation plus R-5 foam sheathing. 9. Doors, including all fire doors, shall be assigned default U -factors from Table 10-6C. 10. Where a maximum glazing area is listed, the total glazing area (combined vertical plus overhead) as a percent of gross conditioned floor area shall be less than or equal to that value. Overhead glazing with U -factor of U=0.40 or less is not included in glazing area limitations. 11. Overhead glazing shall have U -factors determined in accordance with NFRC 100 or as specified in Section 502.1.5. 12. Log and solid timber walls with a minimum average thickness of 3.5" are exempt from this insulation requirement. 34 Effective July 1, 2007 Glazing Glazin U -Factor Wall12 Walls Wall. Slab Option Area' . Doors Ceiling2 Vaulted Above into ext4 Floors on % of Floor Vertical Overhead"U-Factor Ceiling Grade Below Below Grade Grade Grade I. 12% 0.35 0.58 0.20 R-38 R-30 R-21 R-21 R-12 R-30 R-10 int? II.* 15% 0.35 0.58 0.20 R-38 R-30 R-19+ R-21 R-12 R-30 R-10 R-5$ III. 17% 0.32 0.58 0.20 R-38 R-30 R-19 + R-21 R-12 R-30 R-10 R -5s IV. 25% 0.35 0.58 0.20 R-38 / R-30 / R-21 R-15 R-12 R-30 / R-10 / Group R-1 U=0.031 U=0.034 int' / U=0.029 F=0.54 and R-2 U=0.054 Occupancies Only V. Unlimited 0.35 0.58 0.20 R-38 R-30 R-19+ R-21 R-12 R-30 R-10 Group R-3 R -5s and R-4 Occupancies Only VI. Unlimited 0.30 0.58 0.20 R-49 or R-38 R-21 R-21 R-12 R-30 R-10 Group R-3 R-38 Adv int? and R-4 Occupancies Only VII. Unlimited 0.32 0.58 0.20 R-38 ! R-30 / R-21 R-15 R-12 R-30 / R-10 / Group R-1 U=0.031 U=0.034 int? / U=0.029 F=0.54 and R-2 U-0.054 Occupancies Only * Reference Case 0. Nominal R -values are for wood frame assemblies only or assemblies built in accordance with Section 601.1. 1. Minimum requirements for each option listed. For example, if a proposed design has a glazing ratio to the conditioned floor area of 13%, it shall comply with all of the requirements of the 15% glazing option (or higher). Proposed designs which cannot meet the specific requirements of a listed option above may calculate compliance by Chapters 4 or 5 of this Code. 2. Requirement applies to all ceilings except single rafter or joist vaulted ceilings complying with note 3. 'Adv' denotes Advanced Framed Ceiling. 3. Requirement applicable only to single rafter or joist vaulted ceilings where both (a) the distance between the top of the ceiling and the underside of the roof sheathing is less than 12 inches and (b) there is a minimum 1 -inch vented airspace above the insulation. Other single rafter or joist vaulted ceilings shall comply with the "ceiling" requirements. This option is limited to 500 square feet of ceiling area for any one dwelling unit. 4. Below grade walls shall be insulated either on the exterior to a minimum level of R-12, or on the interior to the same level as walls above grade. Exterior insulation installed on below grade walls shall be a water resistant material, manufactured for its intended use, and installed according to the manufacturer's specifications. See Section 602.2. 5. Floors over crawl spaces or exposed to ambient air conditions. 6. Required slab perimeter insulation shall be a water resistant material, manufactured for its intended use, and installed according to manufacturer's specifications. See Section 602.4. 7. Int. denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation. 8. This wall insulation requirement denotes R-19 wall cavity insulation plus R-5 foam sheathing. 9. Doors, including all fire doors, shall be assigned default U -factors from Table 10-6C. 10. Where a maximum glazing area is listed, the total glazing area (combined vertical plus overhead) as a percent of gross conditioned floor area shall be less than or equal to that value. Overhead glazing with U -factor of U=0.40 or less is not included in glazing area limitations. 11. Overhead glazing shall have U -factors determined in accordance with NFRC 100 or as specified in Section 502.1.5. 12. Log and solid timber walls with a minimum average thickness of 3.5" are exempt from this insulation requirement. 34 Effective July 1, 2007 2006 IRC Sib C=rr+-� Ten Things You Must Knozvl.� �� 5� �. c�• ;+`��p � D l 1. 8105.2 "Work Exempt From Permit"— Spokane County will maintain the 200 sq/ft threshold for one-story detached accessory structures used as tool and storage sheds, or similar uses. 2. Table R301.5 "Live Loads" — Attic storage is clarified in the footnotes of this table. An example: If two or more adjacent trusses with the same web configuration contain a rectangle 42 inches or greater in height by 24 inches or greater in width, located within the plane of the truss, a 20 gslliveload must be atiphed to the desien of the bottom chord components affected. 3. R319.L5 "Exposed Glued -laminated Timbers" — Those portions of glu-lam timbers that form structural support -of buildings /structures and are exposed to the weather, and not protected by a roof, eave, or similar covering shall be pressure treated, or naturally durable wood. 4. WAC AMENDMENT 8327 "Protection Against Radon" — State adoption of IRC Appendix F for mitigation measures applicable for buildings constructed in "High Radon Potential Counties" (Spokane county). Appendix F, Section AM 01.1 (WAC Amendment) no longer permits un -vented (conditioned) crawl spaces. Appendix F further requires passive radon vents to be installed in vented crawl spaces. WAC Amends R408.2, permitting 1:300 sq/ft ratios for ventilating crawl spaces. 5. R406.1 "Foundation Damp -proofing" — Language change removes "habitable or usable spaces", and replaces with "foundation walls that retain earth and enclose interior spaces and floors below grade..." effectively requiring damp -proofing of crawl space foundation walls. R406.2 similar for water -proofing. 6. R613.2 "Window Sills" — New section requires protection similar to guardrails (4" dia. sphere) for operable portions of windows less than 24 inches above the finished floor, and greater than 72 inches above the adjacent exterior grade or surface below. 7. R702.4.2 Tile Backer Board — Requires cement, fiber -cement, or glass mat gypsum backers for tile installation in tub and shower areas and wall panels in shower areas. 8. R703.2 and Table R703.4 "Water -resistive Barrier" — Felt, or other approved barriers (house wrap) are now required over all exterior wall studs or sheathing, and there is no longer an exception for not requiring such felt/barriers under panel sidings with shiplap joints. 9. R703.8 "Flashing" — The provisions for self -flashing windows (use if the window's mounting flange) has been eliminated. Approved corrosion -resistive flashings must be applied shingle fashion at all door/window openings. R613.1 requires window manufacturers to provide installation/flashing instructions for each window. 10. Washington State Energy Code Section 505.3 "Outdoor Lighting" — Luminaries providing outdoor lighting and permanently to residential buildings must be high efficiency (compact fluorescent) bulbs with pin style base. Exception allows incandescent fixtures controlled by motion sensors with integral photo sensors. TABLE R602.10.5 LENGTH REQUIREMENTS FOR BRACED WALL PANELS IN A CONTINUOUSLY SHEATHED WALLa, b•` For SI: I inch = 25.4 mm, I foot = 305 mm, I pound per square foot = 0.0479kPa. a. Linear interpolation shall be permitted. b. Full -height sheathed wall segments to either side of garage openings that support light frame roofs only, with roof covering dead loads of 3 psf or less shall be per- mitted to have a 4:1 aspect ratio. c. Walls on either or both sides of openings in garages attached to fully sheathed dwellings shall be permitted to be built in accordance with Section R602.10.6.2 and Figure R602.10.6.2 except that a single bottom plate shall be permitted and two anchor bolts shall be placed at 113 points. In addition, tie -down devices shall not be required and the vertical wall segment shall have a maximum 6:1 height -to -width ratio (with height being measured from top of header to the bottom of the sill plate). This option shall be permitted for the first story of two-story applications in Seismic Design Categories A through C. R602.10.5 Continuous wood structural panel sheathing. When continuous wood structural panel sheathing is provided in accordance with Method 3 of Section R602.10.3 on all sheathable areas of all exterior walls including areas above and below openings, braced wall panel lengths are not required to be in accordance with Section R602.10.4 provided they are in accordance with Table R602.10.5. Wood structural panel 138 sheathing shall be installed at comers in accordance with Figure R602.10.5. The bracing percentages in Table R602.10.1 for Method 3 shall be permitted to be multiplied by a factor of 0.9 for exterior walls with a maximum opening height that does not exceed 85 percent of the wall height or a factor of 0.8 for exterior walls with a maximum opening height that does not exceed 67 percent of the wall height. ORIENTATION OF STUD MAY VARY, SEE FIGURE R602.30 1 16d NAIL A712IN. O.C. GYPSUM WALL INSTALLED A 11 / / ACCORDANCE WITHRCHAPTER 7 IN 8d NAIL AT6IN. O.C. 8d NAIL AT 12 IN.O.C.ON ALL WOOD STRUCTURAL PANEL (ALL PANEL EDGES) FRAMING MEMBERS NOT AT INSTALLED IN ACCORDANCE PANEL EDGES WITH TABLE R602.30) 16d NAIL AT 12 IN, O.C. For SI: 1 inch = 25.4 mm. Gypsum board nails deleted for clarity. (a) OUTSIDE CORNER DETAIL ORIENTATION OF STUD MAY VARY, SEE FIGURE R6023(2) GYPSUM WALL BOARD INSTALLED IN ACCORDANCE WITH CHAPTER 7 (INTERIOR) WOOD STRUCTURAL PANEL INSTALLED IN ACCORDANCE WITH TABLE R602.3(l ) 8d NAR. AT 6 IN, O.C. ALL FRAMING MEMBERS AT PANEL EDGES AND 12 IN_ O,C.ON ALL FRAMING MEMBERS NOT AT PANEL EDGES (b) INSIDE CORNER DETAIL MINIMUM LENGTH OF BRACED WALL PANEL (inches) MAXIMUM OPENING HEIGHT NEXT TO THE BRACED WALL PANEL (% of wall height) 8 -foot wall 9400t wall 10 -foot wall 48 54 60 100 32 36 40 85 24 27 30 65 For SI: I inch = 25.4 mm, I foot = 305 mm, I pound per square foot = 0.0479kPa. a. Linear interpolation shall be permitted. b. Full -height sheathed wall segments to either side of garage openings that support light frame roofs only, with roof covering dead loads of 3 psf or less shall be per- mitted to have a 4:1 aspect ratio. c. Walls on either or both sides of openings in garages attached to fully sheathed dwellings shall be permitted to be built in accordance with Section R602.10.6.2 and Figure R602.10.6.2 except that a single bottom plate shall be permitted and two anchor bolts shall be placed at 113 points. In addition, tie -down devices shall not be required and the vertical wall segment shall have a maximum 6:1 height -to -width ratio (with height being measured from top of header to the bottom of the sill plate). This option shall be permitted for the first story of two-story applications in Seismic Design Categories A through C. R602.10.5 Continuous wood structural panel sheathing. When continuous wood structural panel sheathing is provided in accordance with Method 3 of Section R602.10.3 on all sheathable areas of all exterior walls including areas above and below openings, braced wall panel lengths are not required to be in accordance with Section R602.10.4 provided they are in accordance with Table R602.10.5. Wood structural panel 138 sheathing shall be installed at comers in accordance with Figure R602.10.5. The bracing percentages in Table R602.10.1 for Method 3 shall be permitted to be multiplied by a factor of 0.9 for exterior walls with a maximum opening height that does not exceed 85 percent of the wall height or a factor of 0.8 for exterior walls with a maximum opening height that does not exceed 67 percent of the wall height. ORIENTATION OF STUD MAY VARY, SEE FIGURE R602.30 1 16d NAIL A712IN. O.C. GYPSUM WALL INSTALLED A 11 / / ACCORDANCE WITHRCHAPTER 7 IN 8d NAIL AT6IN. O.C. 8d NAIL AT 12 IN.O.C.ON ALL WOOD STRUCTURAL PANEL (ALL PANEL EDGES) FRAMING MEMBERS NOT AT INSTALLED IN ACCORDANCE PANEL EDGES WITH TABLE R602.30) 16d NAIL AT 12 IN, O.C. For SI: 1 inch = 25.4 mm. Gypsum board nails deleted for clarity. (a) OUTSIDE CORNER DETAIL ORIENTATION OF STUD MAY VARY, SEE FIGURE R6023(2) GYPSUM WALL BOARD INSTALLED IN ACCORDANCE WITH CHAPTER 7 (INTERIOR) WOOD STRUCTURAL PANEL INSTALLED IN ACCORDANCE WITH TABLE R602.3(l ) 8d NAR. AT 6 IN, O.C. ALL FRAMING MEMBERS AT PANEL EDGES AND 12 IN_ O,C.ON ALL FRAMING MEMBERS NOT AT PANEL EDGES (b) INSIDE CORNER DETAIL Attic Ventilation 1 Sq Ft per every 300 Sq Ft of space ventilated with at least 50% in the upper portion of roof area. Attic Accessible ROOFING MATERIAL c.O&'4 P SKtnl &,L&S bV 22'x 30" MFR'G TRUSSES o�zlf"oG IS* fZ00 fri A1 CY mpep- BAFFLE HIARRICAW j4 L -N-1 t+ 1.4 6r OS6 R3 $ INsuLArloN _40# felt for ice dam protection —� Ta 2.4rtASt acs: �- )C rta(UR UJAU- Ya r .W.B. T FASCIA 6 . FINISHED $[DING 5HEATHIN5 41 US8 �Cs.WB. /21ti STUD WALL 2 x& TION t 21 1 J_ - FLOOR 51'STEM vsjCom %L- vtiPaa �a4tiRtt=0- INJJL4TIGN TREATED 2-Xf=- WD. PLATE NSLA L-*krooAtd c� , J Anchor Bolts- Min. '/z"x 9" with 7" concrete embedment at 6' o.c. and 12" from ends of sill plates. W J a W J a Q Ir CO) J a 2 FRONT 1/4"= 1'-0" A" COKf•ER co M T -.4 (M 5fONE WNNSCOf for OF ma _ 10" FACIA 6" TpM TOP PLATE ISO f ROOF PLAN - -- -- -8'-178„� �U UJU 00 T 'o 00 - MAIN LEVEL PLAN 0'-0” T.O. Foundalion ::04---T - 2t - 671 -GARAGE J IL0. FOUND, 6. T.O. FOOTING LEFT -2' - 6" � FOUNDATION _' PLAN a W a O ROOF P_ _LAN B' - 11 1 /8" 1 RIGHT 1/4" = 1'-0" ROOF PLAN MAIN LEVEL PLAN T.O. Foundation GARAGE - - - - _1' _ 0., T.O. FOOTING n _g_6" V FOUNDATION PLAN 3'-0" - ROOF PLAN /1 T.O. Foundation 0'-0" MAIN LEVEL PLAN 0'-0" GARAGE _ TO. FOOTING -V n -- - - -2'_6 FOUNDATION PLAN REAR 3' - 0" t 1/4"= 1'-0" AGE 'o _PAR b 2t - 671 0. FOOTING J IL0. FOUND, 6. LEFT PLAN m L a W a O RIGHT 1/4" = 1'-0" ROOF PLAN MAIN LEVEL PLAN T.O. Foundation GARAGE - - - - _1' _ 0., T.O. FOOTING n _g_6" V FOUNDATION PLAN 3'-0" - ROOF PLAN /1 T.O. Foundation 0'-0" MAIN LEVEL PLAN 0'-0" GARAGE _ TO. FOOTING -V n -- - - -2'_6 FOUNDATION PLAN REAR 3' - 0" t 1/4"= 1'-0" PROJECT NAME: BLY GARAGE REV DATE 1 2Ii D10 FINAL PLANS PERMIT DATE: Issue Date SCALE: 114"- V-0" DRAWN BY: JAG SHEET NAME: ELEVATIONS SHEET NUMBER A-1 'o b Z LU m L utl1, W a O tm F � 0 C LU F Oa a Z a j PROJECT NAME: BLY GARAGE REV DATE 1 2Ii D10 FINAL PLANS PERMIT DATE: Issue Date SCALE: 114"- V-0" DRAWN BY: JAG SHEET NAME: ELEVATIONS SHEET NUMBER A-1 coJ CO Lu a.J N 20'-0" 48" BW 48" BW 5.OFE; CONatre FLOOR 4" FROM BALK TO FRONT R602.10.4 Brace Wall R602.10.5 Continuous R602.10.6.1 Alternate R602.10.6.2 Alternate IBC 2305 Engineered Panel min. 48 in.— 96 in. Wood Structural Panel Sheathing Brace Wall Panel min.28in.-42in. Brace Wall Panel min.16in.-24in. Shear Wall Bracing OMAIN LEVEL PLAN 1/2" = 1'-0" OFOUNDATION PLAN 1/2" = 1'-0" PHONE:(509) 315-5093 LU W CL 0 0J os z 0 8 a. a 0 z 0 (SQUARE FOOTAGE 1 MNn Floor. OSF Upper Floor. 0SF 8000. Nome: 0SF Baamrmrt FMbhao: 0SF Bawnrrt UnenlNnd: 0 9 Total FbrINMd: 0 B Gamma: ISO SF BYerwnl Plat. NL N/A Mole Fir. P10 4 Hr. a t-tir Upper Flr. Pb to Nt. N/A 1 PROJECT NAME: BLY GARAGE REV DATE 2/17/10 FINAL PLANS A A PERMIT DATE: Issue Date SCALE: 12" = 1'-0" DRAWN BY: JAG SHEET NAME: FLOOR PLAN SHEET NUMBER A-2 ' \ it. \ b N r 3'-2" MOW IN FOUNDATION WALL FOR MMI DOOR Minimum depth for frost protection in the City of Spokane Valley is 24 inches measured from the bottom of the footing to finish grade. Grade slope away from building a minimum 6 inches in first 10 feet. CONCRETE TO COMPLYTO IRC TABLE 404.1.11) 6" FOI2Jt1A1ION WNL FOUNDATION WALLS - 3000 # PSI ON 6" x12" FOOTINGS SLABS, GARAGES, CARPORTS & PORCHES -$500 # PSI ALL FOOTINGS MUST BE CONTINUOUS Pressure treated or naturally durable wood is required for sills Pressure and sleepers on a concrete or masonry slab that is in direct contact with the ground unless separated from such slab by an impervious moisture barrier. CONTINUOUS FOOTING UNDiR GARAI2 DOOR Cir) 9'-2" BULKOUIIN l J• - 1 "' i I -- .-- FOIMMION WALL FOR GARAGE DOOR 16-2" �1'-11"� J /1'-11"/ 20'-0" OFOUNDATION PLAN 1/2" = 1'-0" PHONE:(509) 315-5093 LU W CL 0 0J os z 0 8 a. a 0 z 0 (SQUARE FOOTAGE 1 MNn Floor. OSF Upper Floor. 0SF 8000. Nome: 0SF Baamrmrt FMbhao: 0SF Bawnrrt UnenlNnd: 0 9 Total FbrINMd: 0 B Gamma: ISO SF BYerwnl Plat. NL N/A Mole Fir. P10 4 Hr. a t-tir Upper Flr. Pb to Nt. N/A 1 PROJECT NAME: BLY GARAGE REV DATE 2/17/10 FINAL PLANS A A PERMIT DATE: Issue Date SCALE: 12" = 1'-0" DRAWN BY: JAG SHEET NAME: FLOOR PLAN SHEET NUMBER A-2 thivewaions After framing ap- proach and prior to concrete pour or asphalt placement, a right of way inspection is required to ensure proper installation. Inspection request line 869-5673. Driveway Approach Deviations,relocations or alter- ations to existing or designated driveway approaches in subdivisions will require a right of way permit address- ing storm water engineered configuration and sizing. CV DE DIAGRAMS AND EN'C 'LERING LAYOUTS FOR Rc 1 RUSSES, BEAMS i-',' '\i'C'1FLIS t---) -)r--11" TING THESE PLANS MUST BE KEPT ON THE JOB SITE THIS BUILDING SUBJECT TO FIELD IRSPEOTION CORRECTIONS i REVIEWPD P :' ' -:-:,- •-',ONIPLANa: SPnK.,..F'Lr; : k-' w ,'' NI, l!ViSiON 00 __ W -j CL N W J a i U) W J a V/ W J CL vI W J a General Notes AND Design Criteria This plan was designed and drafted by JAG Design Works LLC. to meet average conditions and codes in the State of Washington at the time It was designed. Because codes and requirements can change and may vary from jurisdiction to jurisdiction, JAG Design Works LLC. cannot warrant compliance With any specific code or regulation. Consult your local building official to determine the suitability of these plans for your specific site and application. This plan can be adapted to your local building codes and requirements, but is the responsibility of the purchaser and/or builder of this plan to see that the structure is built in strict compliance with all governing municipal codes. The purchaser and/or builder of this plan releases JAG Design Works LLC. and all shareholders, directors, officers, and employees from any claims or lawsuits that may arise during and after construction of this residential structure. 'Unless noted, all framing lumber to be Hem Fir #2 or better. 'Contractors to confirm size, spacing, and species of all framing and structural members to meet your local code requirements. 'Any structural or framing members not Indicated on the plans are to be sized by contractor. 'PJI exterior walls are dimensioned from outside wall Ones. 'All interi walls are dimensioned from stud to stud or wallboard to stud oroallboard to wallboard. 'Calculated dimensions take precedence over scaled dimensions. 'Any walls use 92 5/8" wall studs with single bottom plate, and double top plate. 'All angled walls are 45d unless stated otherwise. `ATI trusses to be engineered by truss manufacturer according to the loading Indicated on this plan or in accordance to local codes and/or jurisdictions. MISCELLANEOUS NOTES: 'Prefabricated fireplaces and flues are to be U.L. approved and installed per manufacturers' specifications. '1/2" water resistant drywall around showers, tubs, and whirlpools. '12" drywall on interior walls and ceilings. 5/8" Type "X" fire code drywall on garage walls and ceilings. 'Confirm window opening sizes for local egress requirements, light and ventilation requirements. PITCH: Per Plan ROOFING MATERIAL: W Van L.am.3— & 51 Man ��ATTIC INSULATION: RSB Bbwn Whom poatlbla ROOFING PAPER: 15 Pound FM CEILING JOIST: 7-0" O.C. ROOF DECKING: ]MB' OSB Nom. W 10 CEILING FINISH. Irr ShDM=k F 6' OSS Nom. over 40h9now RAFTER ERR & S SYSTEM: Enpiwemd Tmr ICE & WATER SHIELD: Pm Cede DOUBLE 216' TOP PLATE DRIP EDGE: Molal GUTTERS: Por Spee I/r GYPSUM SDARD SUB FASCIq:2'k4' Han 7/13' O38 PANEL LP FASCIA: 512" OVERHANG V/Per Han 51Q' R-21 UNFACED BATT INSULATION LP SOFFiT:12-LP/Per Plan DOUBLE 213' TOP PLATE 2BOTTOM PLATE 18' 4" GRAVEL BASE FINISHED FLOOR PER PLAN W SIDING (DEPENDENT ON (:F REQ -0) HOMEOWNERIBUILDER SELECTION 3/4'T& O EDGE GOLD OR AL(GLUE&N PER BATT INSULATION MFGR. MFOR. SPECIFICATIONS I `—FLOOR JOIST PER ENGINEERED 4"CONCRETE SPECIFICATIONS 7/13' O38 PANEL R-21 KRAFT FACED ° BATT INSULATION ! RIMBOARD DOUBLE 213' TOP PLATE 21C PRECUT STUDS ®1B' O.0 4" GRAVEL BASE FOUNDA71ON WALL W/ 10 GYPSUM BOARD (:F REQ -0) 5 I R-21 UNFACED BATT INSULATION RIMBOARD 7W' BOTTOM PLATE 24" R-10 RIGID FLOOR CASING PER SPEC. INTERMEDIATE SUPPORTS FINISHED FLOOR PER PLAN 213' P.T. SILL PLATE WI 1!r 314-T & G EDGE GOLD OR ANCHOR BOLTS @ ed O.C. CSB EOUAL ( GLUE & MAIL PER AND NO MORE THAN 17 FROM MPGR. SPECIFICATIONS) CORNERS ON SILL -SE ININSULATIONAL ENGINEERED FLOOR SYSTEM UNDISTURBED SOIL RSD SAM AS REOUIRED — — R-21 KRAFT FACED I I_ I BATT INSULATION 0 RIMSDARO WATERPROOFFTOGTOGRADE (BASEMENT ) S'THK. POURED CONIC. WAW VERTICAL REBAR PER 16' WIDE x W DEEP POURED LOCAL CODE CONC. FOOTING W/2-04 CTHK CONIC. SLAB REINFORCING BANS ( CONT.) (BASEMENT OPTION ONLY) 4' PERFORATED FOOTING ' DRAIN IN CRUSHED STONE--_— — BED WITHSILT COVER:RUN _III— — PTHK. MIN. TODAYUGHT.ONLY If REWIRED _ WE TO DRAINAGE GRAVEL BASE TYPICAL 2 -STORY WALL SECTION & 2 GENERAL NOTES n TYPICAL BRACED WALL PANEL 112"= 1'-0" E: SHEET EDGES MUST TACKED BY STUDS 4"CONCRETE GRADE MIN. BD COMMON FLOOR ° _. 7X4" GARAGE WALL S" POURED CONCRETE K4 OR 2 6 BACKING 4" GRAVEL BASE FOUNDA71ON WALL W/ (:F REQ -0) VERT,C AL. REINFORCEMENT (IF ° REQ -D) 24" R-10 RIGID INTERMEDIATE SUPPORTS FOAM INSULATION ° WITHIN 7' OF TOP OF WALL 6'X17CONTINUOUS So COMMONS UNDISTURBED SOIL CONCRETE FOOTING W/ S ® 9- OC. AT REBAR PER PLAN EL EDGES & 17 114 POINTS AT SHEET '.RMEDIATE TYPICAL SLAB ON GRADE DETAIL G�" NOTE: SUPPORTS - 1,-D„ E: SHEET EDGES MUST TACKED BY STUDS TYPICAL ALTERNATE BRACED WALL n PANEL OUTSIDE B'SIB" GARAGE DISOR WRAP TREATED 2X4 2X4 �'-"z SIZE PER MIN. BD COMMON PLANS Z' XV ° _. 7X4" GARAGE WALL NAILS ® 6.O.C. AT PANEL EDGES & 17 ° D.C. AT SHEET INTERMEDIATE SUPPORTS ° STRAP$HPAH022 (2) ANCHOR BOLTS AT 114 POINTS NOTE: b#A ALL SHEET EDGES MUST .I BE BACKED BY STUDS TYPICAL ALTERNATE BRACED WALL n PANEL OUTSIDE B'SIB" GARAGE DISOR WRAP TREATED 2X4 2X4 �'-"z SIZE PER EMBEDDED IN CONCRETE—\ PLANS Z' XV SILL PLATE � _. 7X4" GARAGE WALL TREATED 714- A -A *A EMBEDDED IN CONCRETE 2"W' ' e 2"x6" W FOUNDATKIN WALL W/ GARAGE DOOR BUCKOUT SECTION A -A ( S- WIDER THAN GARAGE DOOR SIZE) INSIDE n TYPICAL GARAGE DOOR BUCKOUT 3/4" _ ,, 0" 'GARAGE WRAP r —— � I I I I I I I I I I I I I I I I I I I I I I i I � I E 1 6:12 rl ROOF PLAN 12" = 1'4r 6:12 p� R ATM UNMAN -------------------------i I I I 6:12 I I I I I I I I I I I I I I I I I I I I I i I I I I 6:12 I I I I I I I I I I I I I I I I I I I I I I I 6:12 I I I I I I---- -- — — — — — — — — — — — — — — — — — — — — — — — — J S p.o A 5e= �fll asci -a 8 W 12 ti A2M111 J ggs�S�g� J 8 Cas C a �on�o Pill k am 0 E 2'& H 1L m O q` N vl M m C o y 0 O a 0 X m vtl1 0-0 a� tV -jW m $ W oo � W Z a u F O tzQ Z Q J Q SQUARE FOOTAGE Main Fk— OSF Upper Floor. OSF Bonin Room: 0 SF EM -4 Flalm": OSF BLR.Mr ALKMinlahad: 0SF TOMI F'YNahad: OSF Gar 490 SF BnamaM Pima HL. WA Main FN. Hala HL 81-1/B' Uppr Flr. PkM XL WA PROJECT NAME: BLY GARAGE REV DATE 1 2/17/10 FINAL PLANS PERMIT DATE: ISSUE, Date SCALE: As indicated DRAWN BY: JAG SHEET NAME: ROOF PLAN SHEET NUMBER A-3 wwcc w 0 PPOPO5PCI PP1WWAY 20'-0" 110.00' PL. PPOPO5e12 GAfZAGI 24' - 0" 34' - 0" NOPM eXI511NG 5111.1CM 110,00' PL PLANNING DEPT. APPROVED 5Y: [SATE: 3/3/v 12'-0" 28 th STREET OSITE PLAN 1" _ 10,_or. 4 1". loi""* D 3 0 PHON E: (509 III LAI a0 O m 0-1 LOCATION: (SQUARE FOOTAGE Main Floor. OSF Upper Floor: 0SF Sows Room: OSF B0wnNH Finished: 0 SF Seteaml UnfnI.MO: OSF Tagl RYUairo: O SF SBO SF B...rMrt Plat. Ht WA Main Fir. Plain W. Upper Flr. Rai. Ht N/A ! PROJECT NAME: BLY GARAGE REV DATE 2/17/10 FINAL PLANS A A PERMIT DATE: Issue Date SCALE: 1" - 10'-0" DRAWN BY: JAG SHEET NAME: SITE PLAN SHEET NUMBER S-1