2007, 10-26 Permit App: 07004306 Basement/AtticProject Number: 07004306 Inv: I Application Date: 10/26/2007 Page 1 of 2
THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Project Information:
Permit Use: REPAIR BASEMENT
Contact: RESCUE RESTORATION INC.
Address: 727 N HOGAN ST
C - S - Z: SPOKANE, WA. 99202
Setbacks: Front Left: Right: Rear:
Phone: (509) 536-7779
Group Name:
Site Information:
Project Name:
Plat Key: 001393 Name: KOKOMO TOWNSITE
(FEES) District: Sout
Parcel Number: 45283.4520 Block:
Lot:
SiteAddress: 10812 E 29TH AVE
Owner: Name: THOMAS, DALLAS A
Address: 10812 E 29TH AVE
Location:: CSV
SPOKANE VALLEY, WA 99206
Zoning: UR -3.5 Urban Residential 3.5
Water District: 007 MODEL
Hold: ❑
Area: 13,000 Sq Ft Width: 0
Depth: 0 Right Of Way (ft): 70
Nbr of Bldgs: 1 Nbr of Dwellings: 1
Review Information:
r.._.
�..
Review
Building Plan Review
Released By
Originally Released: 10/26/2007 By: tmelbourn
Permits: ,,,u n ,-,. —�Ar
Building Permit
Contractor: RESCUE RESTORATION Firm: RESCUE RESTORATION INC
Address: 727 N HOGAN ST Phone: (509) 536-7779
SPOKANE, WA 99204
This Application:
Description Grp Type Notes Sci Ft Valuation
BASEMENT F R-3 VB BASEMENT 0 $24,000.00
REPAIR
Totals: 0 $24,000.00
Item Description Units Unit Desc
RESIDENTIAL PERMIT FEE 1 SELECT
WSBC SURCHARGE 1 SELECT
SF PLNS RVW < 7999 SQ FT I SELECT
Permit Total Fees:
Total Project:
Scl Ft Valuation
0 $24,000.00
0 $24,000.00
Fee Amount
$377.25
$4.50
$150.90
$532.65
Operator: jmm Printed By: jmm Print Date: 10/26/2007
Project Number: 07004306 Inv: 1 Application Date: 10/26/2007 Page 2 of 2
THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Notes:
Payment Summa
Permit Type Fee Amount Invoice Amount Amount Paid Amount Owing
Building Permit $532.65 $532.65 $0.00 $532.65
$532.65 $532.65 $0.00 $532.65
Disclaimer:
Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information
contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be
complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of
the provisions of the code or of any other state or local laws or ordinances.
Signature:
Operator: jmm Printed By: jmm Print Date: 10/26/2007
44 Permit Center ,' 1
CM of000 1.1703 E Sprague Ave, Suite B-3 PERMIT NUMBER: _ �( t ;
Spokane Spokane Valley, WA 99206 PERMIT FEE:
jVa11eY (509)688-0036 FAX: (509)688-0037
www.spokanevalley.or
Community Development
Residential Construction ❑ New Construction ❑ Accessory Bldg
Permit Application ❑ Addition/Remodel ❑ Deck
❑ Other:
SITE ADDRESS: ) V �� — I ' (q a ,i
ASSESSORS PARCEL NO: LEGAL DESCRIPTION:
Building Owner:
_..__ _.-_-- --_
DIMENSIONS:
Name: j !
1
TOTAL HABITABLE SPACE:
Address:
2 NLFLOOR SQ. FTG:
City: )
State: Zip:
Phone: �� �
Fax:
Contact Person
Name:
Phone.
Describe the scope of work in detail:
Contractor:
Name: �, LA—LI,
Address: �404(vel
City: c' State. Zip: e."'
L
Phone: ����, s �1 +l C Fax:
Contractor Lic No: J Exp Date:
City Business Lic. No:
Cost of Project: $
'C4 0 /Y� rx \ r %.s >In 1 uJ 1011 ip-, I0 r nn G, , j (Ai /� f (Ai
Proposed Use:
**************ThP fnllnwinu MTTST he complete: (write N/A if not applicable)**********************
_-_____
HEIGHT TO PEAK:
_..__ _.-_-- --_
DIMENSIONS:
# OF STORIES:
TOTAL HABITABLE SPACE:
MAIN FLOOR TO SQ.
FTG:
2 NLFLOOR SQ. FTG:
UNFIN BASEMENT SQ. FTG:
' .
IMPERVIOUS SURFACE
AREA:
FINISHED BASEMENT
SQ. FTG:
GARAGE SQ. FTG:
DECK/COV. PATIO SQ. FTG:
30% SLOPES ON
PROPERTY:
# OF BEDROOMS:
CONSTRUCTION TYPE:
HEAT SOURCE:
SEWER OR SEPTIC?
The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling, the
dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The
signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done
in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of
Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or
local laws, codes or ordinances. 6) Plans or additional information may be required to be submitted, and subsequently approved before
this application canbe processe L
SIGNATURE: (����� ( vS�L ate" DATE: �`O " - I V J
I V
Method of Payment:
❑ Cash
Bankcard #:
Authorized Signature:
REVISED 2/15/07
❑ Check ❑ Mastercard ❑ VISA
Expires: VIN#:
11703 E Sprague Ave Suite B-3 ♦ Spokane Valley WA 99206
509.688.0036 ♦ Fax: 509.688.0037 ♦ cityhatt@spokanevalley.org
Residential Plan Submittal Minimums
❑ Completed Building & Mechanical application with: Accurate address, Parcel
Number and/or Legal Description, description of work, owner and contractor
information, signature, and date.
❑ Two sets of plans including Site Plan, elevations, floor plans, foundation plans
With details, roof plan, framing plans & details.
❑ Show the height of any proposed buildings or accessory structures.
❑ Floor plan for each floor: Dimension to scale (minimum 1/8") and label each
Room (including sq. footage of house and garage on plans) Show each
level of existing house and square footage of any additions.
All braced wall panel types: show locations and details of installation, including
engineered design.
Egress windows: Provide at least one window or exterior door approved for
Emergency escape or rescue from a basement and in every room for sleeping.
Smoke detector locations
22" X 30" attic access location
18" X 24" crawl space access:
One-hour separation detail: between house and garage
Floor framing details: Joist type, size, spacing and installation details
Roof framing plan and details
Furnace and hot water heater location.
All header locations: type, size, and connections
Foundation plan
Insulation information
cm OF7 ane
jValley*
Community Development
Permit Center
11703 E Sprague Ave, Suite B-3
Spokane Valley, WA 99206
(509)688-0036 FAX: (509)688-0037
www . sp okanevalley. ori
PERMIT NUMBER:! - =j
PERMIT FEE:
Residential Construction ❑ New Construction ❑ Accessory Bldg
Permit Application ❑ Addition/Remodel ❑ Deck
❑ Other:
SITE ADDRESS: 1 n 17 F� 9 r�VJ-
ASSESSORS PARCEL NO: LTh Z n6_f ., 4SZ-O LEGAL DESCRIPTION:
Building Owner:
Name:
Address`
City: State: Zip:
Phone: Fax:
Contact Person
Name:
Phone:
Contractor:
Name: civ n e r --
Address: ^'� L
City: State: Zip:
Phone: Fax:
Contractor Lic No: Exp Date:
City Business Lic. No:
,_Describe the scope of work in detail: Cost of Project: $ CALdt4_� Civ\
ZM < < 'v�Sl�-(wrt o-7 00 3d Co
Proposed Use:
**************The following MUST be complete: (write N/A if not applicable)**********************
HEIGHT TO PEAK:
DIMENSIONS:
# OF STORIES:
TOTAL HABITABLE SPACE:
MAIN FLOOR TO SQ.
FTG:
2 FLOOR SQ. FTG:
UNFIN BASEMENT SQ. FTG:
' �
IMPERVIOUS SURFACE
AREA:
FINISHED BASEMENT
SQ. FTG:
GARAGE SQ. FTG:
DECK/COV. PATIO SQ. FTG:
30% SLOPES ON
PROPERTY:
# OF BEDROOMS:
CONSTRUCTION TYPE:
HEAT SOURCE:
SEWER OR SEPTIC?
The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling, the
dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The
signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done
in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of
Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or
local laws, codes or ordinances. 6) Plans or additional information may be required to be submitted, and subsequently approved before
this application can be c sed.
SIGNATU_ �DATE-
RE:
Method of Paymen
❑ Cash ❑ Check ❑ Mastercard ❑ VISA
Bankcard #: Expires: VIN#:
Authorized Signature:
REVISED 2/15/07
RESIDENTIAL CHECK LIST DIRECTIONS:
Place a check mark in box next to each document required for complete submittal.
❑ SITE PLAN
❑ Property lines and dimensions ❑ Setbacks to property lines
❑ Direction arrow pointing North and orientation to streets ❑ Distance between buildings
❑ Proposed/existing buildings (footprint and dimensions) ❑ Right of way/easement location & sizes
❑ Utilities, septic tank/drain field locations and distances ❑ Driveway approach size and location
BUILDING PLANS (3 SETS) (minimum 1/8 inch scale or completely dimensioned)
❑ Elevations (Front/Rear/Sides) with roof peak and wall height including basement:
❑ Foundation Plan (crawlspace, basement or slab on grade):
❑ Footing sizes and locations ❑ Supporting wood cripple walls or beams
❑ Perimeter concrete foundation wall sizes ❑ Thickened concrete pads supporting
❑ Crawlspace ventilation beams or girder trusses
❑ Floor Plan of each level (finished or unfinished) with dimensions:
❑ Floor Joist direction, size and spacing ❑ Window and door location and sizes
❑ Header, beam or concrete lintel sizes ❑ Window well locations if applicable
❑ Brace wall panel locations ❑ Room usage labels
❑ Water heater and furnace locations ❑ Smoke detector locations
❑ Exhaust fan locations ❑ Attic and crawl space access locations
❑ Deck or concrete patio sizes and locations ❑ Fire Wall construction
❑ Roof Plan:
❑ Engineered truss direction and spacing
❑ Rafter and over frame direction, size and spacing
❑ Wall Section Detail including:
Roof
❑ Slope/ roofing material/ underlayment/ ice dam protection
❑ Sheathing size and type
Ceiling
❑ Joist size and spacing
Wall
❑ Height/ top plate/ stud size and spacing/ sole plate
❑ Exterior sheathing size and type
Floor
❑ Joist size and spacing
Foundation Wall
❑ Concrete or Masonry unit width
❑ Earth to wood separation distance
Footing
❑ Size
Radon
❑ Passive system with Emil vapor barrier
Miscellaneous Construction Details
❑ Deck:
❑ Floor plan/ side view/ dimensions
❑ Floor Joist/ decking direction, size and spacing
❑ Stairway tread rise & run and nosing
❑ Ridge, eave and valley lines
❑ Beam and girder size and location
❑ Truss or rafter size, spacing & connection
❑ Attic insulation/ air space baffle/ ventilation
❑ Size of ceiling gypsum wall board
❑ Siding/ exterior house wrap/ anchor bolts
❑ Insulation, vapor barrier, gypsum wall board
❑ Sheathing or concrete floor size/ insulation
❑ Footing bottom to finished ground level depth
❑ Horizontal & vertical reinforcement if any
❑ Reinforcement if any
❑ Active system with 6 mil vapor barrier
❑ Footings/ post/ and beam size and locations
0 Handrail / Guard height & spacing
t
SCITY po
jkane
Ualley (10
For City Use Only
PLUS Project Number 300
Project Address /U 12
11703 E Sprague Ave Suite B-3 ♦ Spokane Valley WA 99206
509.688.0036 ♦ Fax: 509.688.0037 ♦ permitcenter@spokanevalley.org
As part of our on-going commitment to customer service during the review process of your project
application, we are providing you with a TARGET DATE for the initial technical application review. If for
any reason we cannot meet this date, we will contact you with a revised target date.
Your application review TARGET DATE is l � � I
The TARGET DATE is the date we estimate your project application will have had its initial technical
review. It is not the date for approval or permit issuance.
Tips for a Smoother Proiect Application Review
➢ Submit complete, accurate plans and documents.
Extra time may be required for re -submittals as project application reviewers work on multiple applications and it
may be several days before they can look at your new or revised information.
➢ Designate a specific contact person to communicate with the City.
While the person designated as the applicant's contact person with the City can be changed, one individual with the
expertise for dealing with reviewer comments would be the best choice for the entire review process.
➢ Call staff regarding the status of your project only after the target date shown at the top of the page.
Although you should be contacted on or by the target date, please feel free to contact us if you haven't heard from us
by your target date. Staff may contact you before the target date if the initial review is complete. By following this
procedure, you will save time and allow the reviewers to complete the work more expeditiously.
Steps in the Permit Process
1. Counter Complete. Your application has been accepted as counter complete. This means all of the required
documents, as indicated on your Pre -Application Checklist have been submitted or have been approved for deferred
submittal. This does not prevent technical staff from requesting additional information as a result of their technical review.
2. Quality Check. The next step in the process is a quality check to make sure that the application is reviewable and free
from substantive flaws that would prevent technical staff from completing the technical review once it is started. When
this step is complete, your application will be routed to the appropriate staff and remain in their review queue until it
comes up for review.
3. Technical Compliance. Once an application is administratively complete, it is routed to technical staff for compliance
review. Depending on the type of project, technical staff may include multiple reviewers. You should be contacted by
phone, fax, email, or mail by your TARGET DATE once the initial technical compliance review is complete.
4. Permit Issuance. When the technical compliance review of the application is complete, including any subsequent re -
submittals, each reviewer will approve their section of the application and route it to the Permit Center. When all sections
of the application are received, a Permit Specialist will process the application and contact the person specified on your
application for permit pick-up. Information regarding fees and pre -construction meetings (if required) will be provided by
the Permit Specialist at that time.
WHITE -APPLICANT PINK - BUILDING FILE REV 9/07
Site Address: 10812 E 29TH AVE
Parcel Number: 45283.4520
Project
Transmittal
City of Spokane Valley
Community Development
Department
11703 E. Sprague Ave, Suite 133
Spokane Valley, WA 99206
Phone: 509.688.0036
New project
Previous pre -app meeting El
Plan revisions El
Transmittal Date:
Thursday, October25, 2007
Project Number: 07004306
Zoning: UR -3.5 Water District: MODEL
Fire District: FD 01
Applicant: RESCUE RESTORATION INC. Owner: THOMAS, DALLAS A
727 N HOGAN ST 10812 E 29TH AVE
SPOKANE, WA. 99202 SPOKANE VALLEY, WA 99206
(509) 536-7779
e-mail: e-mail:
Contact: RESCUE RESTORATION INC. Occupant:
727 N HOGAN ST
SPOKANE, WA. 99202 e-mail:
(509) 536-7779
e-mail:
Contractor: RESCUE RESTORATION Arch / Engineer:
727 N HOGAN ST
SPOKANE, WA 99204
(509) 536-7779
e-mail:
Project REPAIR BASEMENT
Description:
Please send all plan review and project comments via e-mail to the
highlighted individuals.
Z.
3.
4.
5.
6.
7.
8.
9.
10.
2006 IRC
Ten Things You Must KnoxY , w sr
R105.2 "Work Exempt From Permit" — Spokane County will maintain the 200
sq/ft threshold for one-story detached accessory structures used as tool and storage
sheds, or similar uses.
Table 8301.5 "Live Loads" — Attic storage is clarified in the footnotes of this table.
An example: If two or more adjacent trusses with the same web configuration
contain a rectangle 42 inches or greater in height by 24 inches or greater in width,
located within the plane of the truss, a 20 psf 'v In rl must be a�to the design
of the bottom chord components affected.
R319.L5 "Exposed Glued -laminated Timbers" —Those portions of glu-lam
timbers that form structural support of buildings/ structures and are exposed to the
weather, and not protected by a roof, eave, or similar covering shall be pressure
treated, or naturally durable wood.
WAC AMENDMENT 8327 "Protection Against Radon" — State adoption of
IRC Appendix F for mitigation measures applicable for buildings constructed in
"High Radon Potential Counties" (Spokane county). Appendix F, Section AF101.1
(WAC Amendment) no longer permits un -vented (conditioned) crawl spaces.
Appendix F further requires passive radon vents to be installed in vented crawl
spaces. WAC Amends R408.2, permitting 1:300 sq/ft ratios for ventilating crawl
spaces.
R406.1 "Foundation Damp -proofing" — Language change removes "habitable or
usable spaces", and replaces with "foundation walls that retain earth and enclose
interior spaces and floors below grade..." effectively requiting damp -proofing of
crawl space foundation walls. R406.2 similar for water -proofing.
R613.2 "Window Sills" — New section requires protection similar to guardrails K'
dia. sphere) for operable portions of windows less than 24 inches above the finished
floor, and greater than 72 inches above the adjacent exterior grade or surface below.
R702.4.2 Tile Backer Board — Requires cement, fiber -cement, or glass mat gypsum
backers for tile installation in tub and shower areas and wall panels in shower areas.
R703.2 and Table R703.4 "Water -resistive Barrier" — Felt, or other approved
barriers (house wrap) are now required over all exterior wall studs or sheathing, and
there is no longer an exception for not requiring such felt/barriers under panel
sidings with shiplap joints.
R703.8 "Flashing" — The provisions for self -flashing windows (use if the window's
mounting flange) has been eliminated. Approved corrosion -resistive flashings must
be applied shingle fashion at all door/window openings. R613.1 requires window
manufacturers to provide installation/ flashing instructions for each window.
Washington State Energy Code Section 505.3 "Outdoor Lighting" —
Luminaries providing outdoor lighting and permanently to residential buildings must
be high efficiency (compact fluorescent) bulbs with pin style base. Exception allows
incandescent fixtures controlled by motion sensors with integral photo sensors.
WSEC TABLE 6-2
PRESCRIPTIVE REQUIREMENTS0.1 FOR GROUP R OCCUPANCY
CLIMATE ZONE 2
* Reference Case
0. Nominal R -values are for wood frame assemblies only or assemblies built in accordance with
Section 601.1.
1. Minimum requirements for each option listed. For example, if a proposed design has a glazing ratio
to the conditioned floor area of 13%, it shall comply with all of the requirements of the 15% glazing
option (or higher). Proposed designs which cannot meet the specific requirements of a listed option
above may calculate compliance by Chapters 4 or 5 of this Code.
2. Requirement applies to all ceilings except single rafter or joist vaulted ceilings.
3. Requirement applicable only to single rafter or joist vaulted ceilings.
4. Below grade walls shall be insulated either on the exterior to a minimum level of R-10, or on the
interior to the same level as walls above grade. Exterior insulation installed on below grade walls
shall be a water resistant material, manufactured for its intended use, and installed according to the
manufacturer's specifications. See Section 602.2.
Floors over crawl spaces or exposed to ambient air conditions.
6. Required slab perimeter insulation shall be a water resistant material, manufactured for its intended
use, and installed according to manufacturer's specifications. See Section 602.4.
7. Int. denotes standard framing 16 inches on center with headers insulated with a minimum of R-5
insulation.
COOPERATIVE EXTENSION
WSEC Builder's Field Guide 5th Edition WASHINGTON STATE UNIVERSITY 1-7
ENERGY PROGRAM
Glazing
Glazing U -Factor
Door -9
Wall 72
Wall?
Wall?
Slala
Slab'
Option
Area 10:
U-
Ceiling2
Vaulted
Ceiling
above
int
Below
ext
Below
Floors
on
% of floor
Factor
Grade
Grade
Vertical
Overhead"
Grade
Grade
I.
10%
0.40
0.58
0.20
R-38
R-30
R-21
R-21
R-12
R-30
R-10
int?
II.
15%
0.40
0.58
0.20
R-38
R-30
R-19+
R-21
R-12
R-30
R-10
R -5s
III.
17%
0.37
0.58
0.20
R-38
R-30
R-19+
R-21
R-12
R-30
R-10
R -5s
IV.
25%
0.35
0.58
0.20
R-38 /
R-30 /
R-21
R-15
R-12
R-30 /
R-10 /
Group R-1
U=0.031
U=0.034
int' /
U=0.029
F=0.54
Occupancy
U=0.054
Only
V.
Unlimited
0.35
0.58
0.20
R-38
R-30
R-21
R-21
R-12
R-30
R-10
Group R-3
int'
Occupancy
Only
VI.
Unlimited
0.32
0.58
0.20
R-38 /
R-30 /
R-21
R-15
R-12
R-30 /
R-10 /
Group R-1
U=0.031
U=0.034
int' /
U=0.029
F=0.54
Occupancy
U=0.054
Only
* Reference Case
0. Nominal R -values are for wood frame assemblies only or assemblies built in accordance with
Section 601.1.
1. Minimum requirements for each option listed. For example, if a proposed design has a glazing ratio
to the conditioned floor area of 13%, it shall comply with all of the requirements of the 15% glazing
option (or higher). Proposed designs which cannot meet the specific requirements of a listed option
above may calculate compliance by Chapters 4 or 5 of this Code.
2. Requirement applies to all ceilings except single rafter or joist vaulted ceilings.
3. Requirement applicable only to single rafter or joist vaulted ceilings.
4. Below grade walls shall be insulated either on the exterior to a minimum level of R-10, or on the
interior to the same level as walls above grade. Exterior insulation installed on below grade walls
shall be a water resistant material, manufactured for its intended use, and installed according to the
manufacturer's specifications. See Section 602.2.
Floors over crawl spaces or exposed to ambient air conditions.
6. Required slab perimeter insulation shall be a water resistant material, manufactured for its intended
use, and installed according to manufacturer's specifications. See Section 602.4.
7. Int. denotes standard framing 16 inches on center with headers insulated with a minimum of R-5
insulation.
COOPERATIVE EXTENSION
WSEC Builder's Field Guide 5th Edition WASHINGTON STATE UNIVERSITY 1-7
ENERGY PROGRAM
Rescue .R;estation, Inc.,.:.
727 N. Hogan
Spokane, Washington 99202
October 22',',',2007 (509) 536-7779 • Fax 534-5659
City of Spokane Valley
Building Permit
re: property located at 10812 E 29th Ave, Spokane Valley
Scope of Repair Work
1. in basement: remove exisiting non-weight bearing wall
from bathroom area to vacate bathroom. This area will
then become an extension of the Rec Room.
2. in bastment: furr -out lower concrete walls to allow
for R- Winsulation (no insulation space currently exists).
The upper half of exisiting walls are 2 x 4 construction - in
the past we have been allowed to fill the available space -
we would appreciate the opportunity to do that again. �o MYd
F"P-k ou-r 2-91- w/z. X Z. -ro c A L" r,6 L X h c,ry t y F&A_ P,2_1 .vS u u4--rco.J
4. in basement: re -wire to bring it to existing code
requirements.
5. Upgrade the mechanical ventilation systems (ie: exhaust
fans in utility room and bathrooms) Mt-r_"Ao t c A L-- P Y -m l -r P,&t;L4'A`t0
6. Remainder of project is standard sheetrock installation,
paint and carpet installation.
Specializing In Cleaning & Repair -
RESCUE RESTORATION, INC
727 N Hogan
Spokane Washington 99202
(509)536-7779 fax(509)534-5659
TAX ID - 91-1674465
Lower Level
svolcurtG Va Heti 99Z.610
16' 5"
THOMAS -RECON 101507
49'11"
10/25/200 Page:
IT
Lower Le,,el
EMERGENCY 14MSS OR MREMENTS
FROM SLEEP" ROOMS
t ► NET CLEAR OPENMIG 5 7 SQUARE FEET
GRADE FLOOR GGE"G 0v►Y.44"i 5C SQUARE FEET
21 NET CLFAR OPENINGHEIGHT 24 INCHES
3) NET CLEAR OPENING WIOTH 20INCHES
4) MAX FINISHED SILL HEIGHT 44' ABOVE FLOOR
5) EMERGENCY ESCAPE & RMUE OPENING SHALL BE
OPERATIONAL FROM THE INSIDE OF THE ROOM WITHOUT
THE USE OF K YS OR TOOLS
WHEN INTERIOR ALTERATIONS, REPAIRS OR ADDITIONS
REQUIRING A PERMIT OCCUR, OR WHEN ONE OR MORE
SLEEPING ROJMS ARE ADDED OR CREATED IN EXISTING
DWELLINGS, THE DWELLING UNIT SHALL BE PROVIDED
WITH SMOKE ALARMS LOCATED AS REQUIRED FOR NEW
DWELLINGS.
SMOKE ALARMS SHALL BE INTERCON.
NECTED AND HARD WIRED IN SUCH A
MANNER THAT THE ACTIVATION OF ONE
ALARM WILL ACTIVATE ALL ALARMS.
(BEDROOMS, AREAS APPROACHING
BEDROOMS, VAULTED CEILING
WITH RISE OF 24` & ON EACH FLOOR)
-� EXHAUST° FANS
100tFM kitdhen
50 CFM bathroonw'
& laundry V;r
RESCUE RESTORATION, INC
727 N Hogan
Spokane Washington 99202
(509)536-7779 fax(509)534-5659
TAX ID - 91-1674465
c-
r%CD
- r
Upper Level `J
n, r".%
' 4
/og/z E 2r(
<51)K.cc rI e Va lley ?g Ze ce,
19' 9"
7' 9"
12' 5"
I-4' 8"
N
1
0)
10' 2"
DDRM
//----693"
21'11"
HALL
ENTRY
29' 10"
MSTRBDRM
15' 2"
7' 5"
3"�'�
MSTRBATU
io
Y
THOMAS-RECON101507
13' 4"
KITCHEN
18'
11"
LIVING
11'
49' 10"
10/25/20
Upper Lea el
CITY COPY
THIS BUILDING SUBJECT
TO FIELD INSPECTION CORRECTIONS
!��
REVIEWED FOR CODE COMPLIANCE
SPOKANE VALLEY BUILDING D VISION