Loading...
1995, 02-16 WA State Energy Code Compliance aTTStIN 5 .4 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 02/16/95 ILE: C: \\WATTDATA\\JEN13202 .WS HOUSE ID: 4 PLEX ( MARK JENSEN ) . Site: 13202 E . 31ST COURT Analyst: TAS SPOKANE , WA Jurisdiction: SPOKANE COUNTY ( ) - Utility: WWP neowner : MARK JENSEN House Type : Multi-family Floor Area: 3082 ft2 ( 509 )927-5934 Builder : Weather Data: Spokane , WA Climate Zone: 2 ( ) - The PROPOSED design *COMPLIES* with 1991 WA State Energy Code . REFERENCE PROPOSED H �OMPONENT PERFORMANCE 432 405 Btu/hr-F ENERGY BUDGET 4 .17 4 .32 kWh/ft2-yr EFERENCE DESIGN Reference 1:omponent Value X Area = UA )n Grade Slab F-0 .540 160ft 86 .4 31a.zing 0215% U-0 .400 462 .3 184 .9 )oors U-0 .200 84 .0 16 .8 aG Wall U-0 .044 2174 ' 95 .6 :ening , Attic U-0 .031 1541 47 .8 Enfiltration ACH-0 .350 26189ft3( 158 .6 ) Reference UA 432 2OPOSED DESIGN COMPONENTS :omponent Description Value X Area = UA 3G Wall R11 Batt 7 ' depth U-0 .051 0 0 .0 BG Slab F-0 .541 Oft 0 .0 )n Grade Slab R10 4 ' vertical F-0 .480 160ft 76 .8 lazing @8% **2 glaze vinyl 3/4" U-0 .500 240 .0 120 .0 )oars **Metal Insul , w/ Raised Panel U-0 .220 84 .0 18 .5 Wall R19 INT Lap Wood U-0 .058 2396 139.0 :eiling R38 blown Attic STD baffled U-0 .031 1157 35 .9 :ems in parentheses not included in COMPONENT PERFORMANCE totals . Denotes non-standard values - check calculation of thermal value . Page 1 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 02/16/95 /r - TDATA\\JEN13202 .WS HOUSE ID: 4 PLEX ( MARK JENSEN ) ------------- ---R38 blown Scissor 4: 12 STD baffled U-0 .040 384 15 .4 Standard Air Sealing ACH-0 .350 26189ft3 ( 158 .6 ) Proposed UA 405 truc Mass Light Frame , Sheetrock walls M- 3 .000 1541 4623 Slab w/carpet w/pad , Sheetrock wall M- 5 .000 1541 7705 ATING/COOLING/VENTILATING SYSTEMS PROPOSED Heating System Type : Electric : Zoned System Efficiency: 100 % Modified Efficiency: 100 % Design ACH: 0 .60 esign Load( at 66F dt ): 44703 Btu/hr Total Load: 44703 Btu/hr System Size: 19 .5 kW ( 150% ) Average Annual Heat: 17309 kWh Annual Cost : $ 952 Ventilation System: Integrated Spot & Whole House Cooling System: SEER: 0 .0 ( ) oling Load( at 12F dt ): 18206 Btu/hr System Size( %Over ): 2 . 1 tons( @125% ) nual Cool Requirement : *** kWh/yr Solar Access: Partially Shaded AZING ORIENTATION PROPOSED PROPOSED South 60 .0ft2 ' North 60 .Oft2 Southeast : Northwest : East 120 .0 West Northeast : Southwest : onomic and energy consumption estimates are designed for comparative rposes only . Actual cost for heating will vary depending on weather nditions . occupant lifestyle and other factors . Page 2