Loading...
HomeMy WebLinkAbout1995, 02-16 WA State Energy Code Compliance = WATTSUN'5 .41991 WA STATE ENERGY 'CODE COMPLIANCE REPORT 02/16/95 FILE: C:\\WATTDATA\\JEN13208 .WS HOUSE ID : 4 PLEX ( MARK JENSEN ) Site: 13208 E . 31ST COURT Analyst : TAS SPOKANE , WA Jurisdiction: SPOKANE COUNTY ( ) - Utility: WWP Homeowner : MARK JENSEN House Type: Multi-family Floor Area : 3082 ft2 ( 509 )927-5934 Builder : Weather Data : Spokane , WA . Climate Zone : 2 ( ) _ The PROPOSED design *COMPLIES* with 1991 WA State Energy Code . REFERENCE PROPOSED COMPONENT PERFORMANCE 432 405 Btu/hr-F ENERGY BUDGET 4 . 17 4 .32 kWh/ft2-yr REFERENCE DESIGN Reference Component Value X Area = UA On Grade Slab F-0 .540 160ft 86 .4 Glazing 015% U--O .400 462 .3 184 .9 Doors U-0 .200 84 .0 16 .8 AG Wall U-0 .044 2174 95 .6 Ceiling , Attic U-0 .031 1541 47 .8 Infiltration ACH--0 .350 26189ft3( 158 .6 ) Reference UA 432 PROPOSED DESIGN COMPONENTS Component Description Value X Area = UA , BG Wall R11 Batt 7 ' depth U-0 .051 0 0 .0 BG Slab F-0 .541 Oft 0 .0 On Grade Slab R10 4 ' vertical F-0 .480 160ft 76 .8 Glazing 08% **2 glaze vinyl 3/4" U-0 .500 240 .0 120 .0 Doors **Metal Insul , w/ Raised Panel U-0 .220 84 .0 18 .5 AG Wall R19 INT Lap Wood U-0 .058 2396 139 .0 Ceiling R38 blown Attic STD baffled U-0 .031 1157 35 .9 Items in parentheses not included in COMPONENT PERFORMANCE totals . ** Denotes non-standard values - check calculation of thermal value . Page 1 • WATTSUN5 .41991 WA STATE ENERGYCODECOMPLIANCE REPORT 02/16/95 FILE: C:\\WATTDATA\\JEN13208 .WS HOUSE ID: 4 PLEX ( MARK JENSEN ) R38 blown Scissor 4: 12 STD baffled U-0 .040 384 15 .4 Infiltration Standard Air Sealing ACM-0 .350 26189ft3 ( 158 .6 ) Proposed UA 405 Struc Mass Light Frame , Sheetrock walls M- 3 .000 1541 4623 Slab w/carpet w/pad , Sheetrock wall M- 5 .000 1541 774.5 HEATING/COOLING/VENTILATING SYSTEMS PROPOSED Heating System Type : Electric: Zoned System Efficiency: 100 Modified Efficiency : 100 Design ACH: 0 .60 Design Load( at 66F dt ): 44703 Btu/hr Total Load: 44703 Btu/hr System Size : 19 .5 kW ( 150% ) Average Annual Heat: 17309 kWh Annual Cost : $ 952 Ventilation System: Integrated Spot & Whole House Cooling System: SEER: 0 .0 ( ) Cooling Load( at 12F dt ): 18206 Btu/hr System Size( %Over ): 2 . 1 tons( @125% ) Annual Cool Requirement : *** kWh/yr Solar Access: Partially Shaded GLAZING ORIENTATION PROPOSED PROPOSED South 60 .Oft2 North 60 .Oft2 Southeast : Northwest : East 120 .0 West •• Northeast : Southwest : Economic and energy consumption estimates are designed for comparative purposes only . Actual cost for heating will vary depending on weather conditions , occupant lifestyle and other factors . Page 2