2006, 09-29 Permit App: 06003885 Pole BldgParcel Number: 45283.5629 Block: Lot: SiteAddress: 11313 E 32ND AVE Owner: Name: BATES, DARRYL Address: 11313 E 32ND AVE Location:: CSV SPOKANE VALLEY, WA 99206 Zoning: UR -3.5 Urban Residential 3.5 Water District: Hold: ❑ Area: .00 Acres Width: 1021 Depth: 130 Right Of Way (ft): 0 Nbr of Bldgs: 0 Nbr of Dwellings: 1 Review Information:. Review Flood Plain Release&By:_ Originally Released: 9/28/2006 By: amblake Building Plan Review Released By: Originally Released: 9/29/2006 By: TMELBOU Driveway/Approach Released;By: Landuse/Zoning/HE Conditions Released''By: Originally Released: 9/28/2006 By: cjjanssen Operator: AMB Printed By: AMB Print Date: 9/29/2006 Project Number: 06003885 Inv: l Application Date: 9/28/2006 Page 1 of 2 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Proiect Information: Location:: CSV Zoning: UR -3.5 Urban Residential 3.5 Water District: Area: .00 Acres Width: 1021 Nbr of Bldgs: 0 Nbr of Dwellings: 1 Address: 11313 E 32ND AVE SPOKANE VALLEY, WA 99206 Hold: ❑ Depth: 130 Right Of Way (ft): 0 Review Information: ..a. ., :i ->. - Review Flood Plain Landuse/Zoning/HE Conditions Sewer Review Operator: AMB Printed By: AMB Print Date: 9/28/2006 Page 2 of 3 Description Grp Type Notes POLE BDLG U-1 VB Item Description RESIDENTIAL PERMIT FEE ACCESSORY PLANS REVIEW WSBCSURCHARGE Total Project: Sg Ft Valuation 864 $16,416.00 864 $16,416.00 Fee Amount $279.25 $69.81 $4.50 $353.56 Operator: AMB Printed By: AMB Print Date: 9/29/2006 This Application: Sg Ft Valuation 864 $16,416.00 Totals: 864 $16,416.00 Units Unit Desc 1 SELECT 1 SELECT 1 SELECT Permit Total Fees: Total Project: Sg Ft Valuation 864 $16,416.00 864 $16,416.00 Fee Amount $279.25 $69.81 $4.50 $353.56 Operator: AMB Printed By: AMB Print Date: 9/29/2006 Project Number: 06003885 Inv: I Application Date: 9/29/2006 Page 3 of 3 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Notes: All driveway approaches to be constructed per Spokane County Standards as adopted by the City of Spokane Valley. Minimum of 7.5' from each property line, 5' from crosswalks or intersection curb and minimum of 15' of separation between any two approaches. Flat portion of a residential approach to be minimum of 16' wide, maximum of 30' wide and combined approach width not to exceed 50% of total frontage. (A)❑THE BULDING OFFICIAL IS AUTHORIZED TO REQUIRE THE PERMIT APPLICANT TO PROVIDE FEE REIMBURSEMENT TO THE CITY OF SPOKANE VALLEY FOR ANY PROFESSIONAL SERVICES REQUIRED OUTSIDE OF CITY STAFF REVIEW. (B)❑SOME EXAMPLES OF POTENTIAL OUTSIDE RESOURCES INCLUDE PLAN REVIEW, CONSTRUCTION INSPECTION AND SURVEYING. Payment Summary: x. Permit Type Fee Amount Invoice Amount Amount Paid Amount Owing Building Permit $353.56 $353.56 $0.00 $353.56 $353.56 $353.56 $0.00 $353.56 Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: AMB Printed By: AMB Print Date: 9/29/2006 Permit Center ` ;, , I S , 11707 E Sprague Ave, Suit lfl '' " l� -q PERMIT NUMBER: 61 aalne 8 Spokane Valley, WA 992061 Valley (509)688-0036 FAX: (509)688-0037 6 - PERMIT FEE: Community Development .���'.s okanevalle .or�.coi 9�} i v i� Residential Construction New Construction ❑ Accessory Bldg Permit Application ❑ Addition/Remodel ❑ Deck ❑ Other: SITE ADDRESS/,�j/ 3 f'• ��? " �� �e ASSESSORS PARCEL 3-7C,, SCQ ZcI LEGAL DESCRIPTION:. e Ko/-» v 9-#/C to// L *S / S-* 14e e/A-1 sco Exe Building owner Name: Do-j-.-L/- Address: / / / 3 / 3 F • a '0 C/ xi L 2 City: S v -a h e- zip: 89 Phone: U t-1 Fax: Contact Person'_ Name: �l /� Z z a r d Phone: "7"7-]' --�0`-2q U Contractor %rc��1z�-P 5 I1era Name: TOTAL HABITABLE SPACE: /lam / Address: C,)( G S - City: S t FOL" C' zip: 3 Phone: •'7-77 • "Ta170 Fax: 026 Lf S 7 Sit -7 0 Lic No: ST £ £t S4 pcly)3D Exp. Date: 02 c c City Business Lie No: h / � Describe the scope of work in detail: Cost of Project: $ v a(-/x.36�xI-;2 46(e bul ld irtg **************The following MUST be complete: (write N/A if nota licable)********************** HEIGHT TO PEAK: DIMENSIONS: # OF STORIES: TOTAL HABITABLE SPACE: /lam / . t/X' l / /1J /' -T MAIN FLOOR TO SQ. 2 FLOOR SQ. FTG: UNFIN BASEMENT SQ. FTG: IMPERVIOUS SURFACE FTG: a(� N h / � AREA: � /�� � C' 4 FINISHED BASEMENT GE SQ. FTG: DECK/CU V. PATIO SQ. FTG: 30% SLOPES ON SQ. FTG: lv p- N Ip TY: /`� f # OF BEDROOMS: CONsT UCTION TYPE: HEATS RCE: SEWER R SEPTIC? N l'Ol e Z1 " x1 DISCLAIMER The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling, the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or local laws, codes or ordinances. 6) Plans or additional information may be required to be submitted, and subsequently approved before this application calf be processed. Signature i Date Method of Payment. (Faxed permit applications will only be accepted with major bankcard) ❑ Cash ❑ Check ❑ Mastercard ❑ VISA ❑ Other Bankcard #: Expires: VIN#: Authorized Signature: REVISED 8/25/2005 0cin0kane Valley 11707 E Sprague Ave Suite 106 ♦ Spokane Valley WA 99206 509.921.1000 ♦ Fax: 509.921.1008 ♦ cityhaLt@spokanevaltey.org Residential Plan Submittal Minimums ❑ Completed Building & Mechanical application with: Accurate address, Parcel Number and/or Legal Description, description of work, owner and contractor information, signature, and date. ❑ Two sets of plans including Site Plan, elevations, floor plans, foundation plans With details, roof plan, framing plans & details. ❑ _ Show the height of any proposed buildings or accessory structures. ❑ Floor plan for each floor: Dimension to scale (minimum 1/8") and label each Room (including sq. footage of house and garage on plans) Show each level of existing house and square footage of any additions. ❑ All braced wall panel types: show locations and details of installation, including engineered design. ❑ Egress windows: Provide at least one window or exterior door approved for Emergency escape or rescue from a basement and in every room for sleeping. ❑ Smoke detector locations ❑ 22"X 30" attic access location ❑ 18" X 24" crawl space access: ❑ One-hour separation detail: between house and garage ❑ Floor framing details: Joist type, size, spacing and installation details ❑ Roof framing plan and details ❑ Furnace and hot water heater location. ❑ All header locations: type, size, and connections ❑ Foundation plan ❑ Insulation information STEEL STRUCTURES AMERICA, INC. 1-800-833-9997 Name Da212,Q / do f -e -S Mailing Address //.3/3 ��St 3 7•r OV-0— City SPoka,,..c Uall,&y StateLAj-&- Zip !a T2oa' Job Address City State County _ S Pekary -- Zip Sidewall 10-46— Gable Telephone Home Work Building Size x x 60' 70' 80' 90' i Appt. Time Date_ 0 10' 10' 20' 30' 40' 20' 30' 40' 50' /A�BaX loz��� 00. ay' / (e f 4 - V 0 L ��P. I ��)ao .� - ,�c-ry 1-0-T SQ0t2-e-L PLANNING DEPT. APPROVED BY -0--j \L -Q - ,y DATE: C 12S 10(c Scale: 3/4 =U' Customer Signature Sales Signature Job Name: Truswal I stems Plates are 20 a. unless shown by "18"(18 ga ), "ll ga.) or "MX"(TWMX 20 ga.), positioned per Joint Details Report. Circled plates and false frame ales ora sitione as shown above. Shin able stud latex to avoid overha with structural lases(or staple). Truss ID: ST24 Qty: 1 BRG X -LOC REACT SIZE REQ'D TC 2x6 HF 18 OF -1.6E Designed per ANSI/TPI 1-2002 This design lased on chard bracing applied 1 0- 2-12 3600 5.50" 4.71"- BC 2x6 IDoOf-3.6E This design does not account for long term per the following schedule: 2 23- 9- 4 3600 5.50" 4.71" OF WEB 2x4 DFL STIR) time dependent loading (creep). Building max O.C. from to BRG REQUIREMENTS shown are based ONLY Lumber shear allmnables re per NDS. THIS DESIGN IS THE COMPOSITE RESULT OF Des,must account for this. Refer to Joint OC Detail Sheet for TC 24.00" 0- 0- 0 z4- 0- 0 BC 108.00" 0- 0- 0 24- 0- 0 on the truss material at each bearing MULTIPLE LOAD CASES. Maximum Rotational Tolerance used UPLIFT REACTION(S) MAX DEFLECTION (span) : IF HANGERS ARE INDICATED ON THIS DRAWING, THEY ARE BASED ON S.S" HANGER NAILS FOR SRC/IBC truss plate values are based on testing and approval as required by IBC 1703 Support Cd,C Wind Non -Mind 1 -792 1b L/682 MEM 7-8 (LIVE) LC 1 1 -PLV AND 3" HANGER NAILS FO0. NUL7I-PLV nd ANSI/TPI and a e reported in available 2 -792 ib L- -0.41" D. -0.10" T= -0.52" CRITICAL MEMBER FORCES: 7C [OHP. WR. / TENS. DUR. [SI GIRDERS. IF 2.5" GUN NAILS ARE USED , THE HANGERS MUST BE RE-EVALUATED (BY 6%ERS). documents such as ICBO !1607. Loaded for 10 PSF non -concurrent RCLL. This truss is desi ped using the ASCE7-02 Wind Spec fication Ves, 1-2 -6258 1.15 / 1721 1.60 0.85 ASCEIT SNOW LOAD DESIGN CRITERIA: Pg 40 Ce 1.0, 1b. 1.0, Ct 1.10 Loaded far 200 16 non -concurrent moving BCLL Hldg Enclosed = Importance Factor = 0.87 Truss Location Not End Zone 2-3 -6972 1.15 / 1529 1.60 0.89 . psf, . Designed for a post -frame building THE PURLINS IF SPECIFIED ON THE . Hurricane/Ocean Line . No Exp Category = C 3-4 -6972 1.15 / 1528 1.60 0.89 4-5 -6256 1.15 / vz1 1.60 0.15 application. pV BOTTOM CHORD MAY NOT SUPPORT ANY Bldg Length = 24.00 ft Bldg Width = 24.00 ft MeM height 14.25 ft, 90 TRUSPLUS 6.0 VER: T6.5.30 CEILING LOAD. THEY ARE FOR LATERAL roof . mph = TPI Lm Hazard Dead Load . 3.6 psf C R. CSI 6-7 -15391.60/ 766015 6.92 CoMP. WR./ TENS.TI... DEFL RATIO: L/240 TC: L/18 BRACING ONLY. THESE PURLINS ARE ne Main Wind Force Resisting System Cnponents Cladding 7-8 -9381.60/ 514715 0.59 NOT REQUIRED IF A RIGID CEILING ansiyyned an and Tributary Area = 144 sgft 8-9 -381.60/ 734717 0.74 IS DIRECTLY ATTACHED. THE APPLIED 9-i6 _1953911.601/ 766015 o.9z CEILING LOAD MUST BE ATTACHED AT DIIR. CSI R. / TENS.il 2-7 -206015 / 4771.60 0.49 WB COMP.T1.1 34"O.C, MAX. 3-7 -40560 / 23621.15 D. 3-9 -40560 / 21621.1S 0.72 4-9 -206015 / 477.60 0.49 1 2 3 4 5 4.00 4.0 T 8-B 4-4 4-4 4-6-1 4-6 1 SH 8-12 8-12 l z z 0-6-1 6-6 S=6-8 0-6-1 B1 Fr6 82 W:508 VV:508 R:3600 R:3600 U:-792 U:-792 t 24-0-0 6 7 B 9 10 Truswal I stems Plates are 20 a. unless shown by "18"(18 ga ), "ll ga.) or "MX"(TWMX 20 ga.), positioned per Joint Details Report. Circled plates and false frame ales ora sitione as shown above. Shin able stud latex to avoid overha with structural lases(or staple). 616/2006 99! RNING Read ail notes on this sheet and give a copy of it to the Erecting Contractor. Cust: design I: fix an Individual building eomponenl not truss system. It has been based on specifications on vlded try the component manufacturer W0: Dri ve_C_st3_L000O S_300001 ® :is and done fn accordance with the cunent versionsof TPI and AFPA design standards. Nm reapmalbillry le assumed for dmensionaf eccurecy. Dimensions Dsgn r • RM #LC = 49 WT • 144 are to be verified by the component manufacturer andfor building designer prior to fabdcaffon. The building designer must ascertain that the load TC Live 40.00 psf LiveDur L=1.15 P=1.15 utlNzed on this design meet or exceed the toading Imposed by the local Wilding code and the partlwlar applicators The design assumes that the top chord TIMBERLINE mister'llybraced bythe roof orflow sheammgand the boommchord Islaterarynacedbyarigid sheathing material directly attached, unleaeomeriMse TC Snow 30.80 psf SnowDur L=1.15 P=1.15 noted. Bracing shown Is for lateral support of components members only to reduce Wciding length. This component shall not be placed in any TC Dead 5.00 psf Rep M6r Find /Comp /Tens ®TRUSS 8525 North Freya Street environmerdmatvANcause the moisture content ofthe wood toexceed 19%andforcause connector plate corrosion. Fabricate, hands,instaA and brace this trues In accordance wins the following standards: 'Joint and Cutting Detail Reportsavallable tie output from Truswal software, BC Live 0.00 psf 1.00 / 1.00 / 1.00 Spokane, WA 992117 'ANSI/TPI 1', WTCA 1'- Wood Truss Council of America Standard Design RespondhNitle0.'BULDINe COMPONENT SAFETY INFORMATION' - BC Dead 5.00 psf O.C.Spacing 6- 0- 0 (BCSI 1-03) and TICS) SUMMARY SHEETS' l5' WfCA and 7P1. The Trues Plate Inetltule (TPI) le located at 583 D'OnofdO Odve, Madeon, TRUSPLUS 6.0 VER: T6.5.30 Wriconsin53719. Th. AmedcanForest and PIP,, Association (AFPA)Islocated ofIIIII M Street, NW, Ste 800,WashinglogDC20036, Bldg Code: IBC -2003 DEFL RATIO: L/240 TC: L/18 0 A"lk---Jmmw-- CONTRACTOR TO VERIFY ACTUAL NORTH ON JOBSITE 12' 1 24' 12' 1 1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH THE 2003 INTERNATIONAL BUILDING CODE. 2. ALL FRAMING MATERIAL SHALL BE HEM FIR NO. 2 OR BETTER. DOUGLAS FIR NO. 2 MAY BE SUBSTITUTED AS AN ALTERNATIVE. WOOD IN CONTACT WITH EARTH AND/OR CONCRETE SHALL BE PRESSURE TREATED, 0.6 RETENTION. 3. CONCRETE DESIGN BASED ON A COMPRESSIVE STRENGTH OF 2500 PSI AND NO SPECIAL INSPECTION REQUIRED. RECOMMENDED CONCRETE STRENGTH IS 4000 PSI FOR DURABILITY ONLY. 4. ROOF SHEATHING SHALL BE PAINTED 29 GA. RIBBED STEEL. FASTEN SHEATHING TO PURLINS WITH 1 1/2" #9 SCREWS WITH NEOPRENE WASHERS AT 9" C/C. 5. SIDE SHEATHING SHALL BE PAINTED 29 GA. RIBBED STEEL. FASTEN SHEATHING TO GIRTS WITH 1 1/2" #9 SCREWS WITH NEOPRENE WASHERS AT 9" C/C 6. TRUSS MANUFACTURER SHALL VERIFY LOAD BEARING POINTS FOR ALL TRUSSES. 7. (4) 16d GALV. NAILS MAY BE SUBSTITUTED FOR (3) 20d. 8. DESIGN LOADS: LIVE LOAD: 20 PSF SNOW LOAD: 40 PSF WIND SPEED: 85 MPH EXP C SEISMIC ZONE: D1 SOIL BEARING: 1500 PSF NOTES C/C = CENTER TO CENTER DBL = DOUBLE GALV = GALVANIZED HD = HOT DIPPED MIN = MINIMUM PT = PRESSURE TREATED SCSJ = SAW CUT JOINT SW = SHEAR WALL TYP = TYPICAL EXTENTS OF CONCRETE SLAB LEGEND EXPIRES 08/18/ & FOUNDATION PLAN SCALE: 3/16"=1' DRAWN BY: FC APPROVED BY-CINS I ADDRESS WHERE WORK WILL BE ONE' PRWE01 SRr. w,uE sRT� 1 DATE 9/14/06 PROJ. NO.: 2832.0/ 3686 11 13 EAST 32nd AVDARREL BATES FOUNDATION PLAN NO.: T OKANF VA WA 2ex36'x12' POLE BUILDING AND NOTES SPOKANE COUNTY 36' 12' � 12' -12' / 3068 / - � 4x6 � \ J N t%1 O o NOTE: ALL POSTS ARE \ PT 6x6 #2 HEM FIR, - o UNLESS NOTED OTHERWISE SCSJ (IR _ \ EMBED ALL 4x IN 12"0, 2'-0" DEEP x t0 '- 4" CONCRETE SLAB ON GRADE. SMOOTH TROWEL FINISH DETAIL 1/S3 TYP 12' 1 24' 12' 1 1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH THE 2003 INTERNATIONAL BUILDING CODE. 2. ALL FRAMING MATERIAL SHALL BE HEM FIR NO. 2 OR BETTER. DOUGLAS FIR NO. 2 MAY BE SUBSTITUTED AS AN ALTERNATIVE. WOOD IN CONTACT WITH EARTH AND/OR CONCRETE SHALL BE PRESSURE TREATED, 0.6 RETENTION. 3. CONCRETE DESIGN BASED ON A COMPRESSIVE STRENGTH OF 2500 PSI AND NO SPECIAL INSPECTION REQUIRED. RECOMMENDED CONCRETE STRENGTH IS 4000 PSI FOR DURABILITY ONLY. 4. ROOF SHEATHING SHALL BE PAINTED 29 GA. RIBBED STEEL. FASTEN SHEATHING TO PURLINS WITH 1 1/2" #9 SCREWS WITH NEOPRENE WASHERS AT 9" C/C. 5. SIDE SHEATHING SHALL BE PAINTED 29 GA. RIBBED STEEL. FASTEN SHEATHING TO GIRTS WITH 1 1/2" #9 SCREWS WITH NEOPRENE WASHERS AT 9" C/C 6. TRUSS MANUFACTURER SHALL VERIFY LOAD BEARING POINTS FOR ALL TRUSSES. 7. (4) 16d GALV. NAILS MAY BE SUBSTITUTED FOR (3) 20d. 8. DESIGN LOADS: LIVE LOAD: 20 PSF SNOW LOAD: 40 PSF WIND SPEED: 85 MPH EXP C SEISMIC ZONE: D1 SOIL BEARING: 1500 PSF NOTES C/C = CENTER TO CENTER DBL = DOUBLE GALV = GALVANIZED HD = HOT DIPPED MIN = MINIMUM PT = PRESSURE TREATED SCSJ = SAW CUT JOINT SW = SHEAR WALL TYP = TYPICAL EXTENTS OF CONCRETE SLAB LEGEND EXPIRES 08/18/ & FOUNDATION PLAN SCALE: 3/16"=1' DRAWN BY: FC APPROVED BY-CINS I ADDRESS WHERE WORK WILL BE ONE' PRWE01 SRr. w,uE sRT� 1 DATE 9/14/06 PROJ. NO.: 2832.0/ 3686 11 13 EAST 32nd AVDARREL BATES FOUNDATION PLAN NO.: T OKANF VA WA 2ex36'x12' POLE BUILDING AND NOTES SPOKANE COUNTY ssnal 03a33NION3 38d I I I I I I I I I z I I I I I I I I I I I J I I I I I 00� i IL LLJ D 0 J LLJ I I i I I I I I I 1 1I I (032)33NIJN3 321d) j — SSii l8 l — — -- 21 I I I I I I I I I I I I I I I i I I I I I I I I SNIT end(0a gx" I I I I I I I I I I I I I I I I I I i I I I I I 03833114191143 1321d) SSf iu T a I I I I I I I I I I I I I i I I I I i I I I I i I [�-W I U = _ O � � J W Li I D W d i I I II i I I , , Ssns1 032 33NIJN3 3S1 , , NAIL TRUSS TO POST WITH (5) 20d HD GALV. TYP VAIL 2x6 BLOCK JNDER TRUSS WITH (1 1) 20d HD 3ALV. TYP NAIL 2x6 TO POST WITH (3) 20d HD GALV. TYP 0 z_ La. A Ac3 D z W IL D Z d Z g a z L6 0 0 2 9 N ?C 9 40 K ;a �A �- I f 12 (21) 20d HD GALV (3) SIDES, STAGGERED 12 1" EXPOSED 4 Q, CONCRETE PRE GINEERE T USS SLAB GRADE + _ + FASTEN TRUSS TO POST WITH 2x6 GIRTS 1-11 1=I I (1) 5/8" THRU BOLT AND C/C (24) 30d HD 16' (4) 20d HD GALV NAILS, AT 2 ++ I I IDES PRE—DRILL. NOTCH POST AND 11'± MIN DEPTH .II _ STAGGERED 12 FIT TRUSS FLUSH WITH POST. 3'-6" VIII + 1" EXPOSED CLEAR `O CO �I ILt CONCRETE Q0 Q0 + PT 2x10 ;I�1 + 11111 CONCRETE SLAB BASE GIRT I I=1I — _ 2'-0" 0 1— 24' SECTION A - MAIN BUILDING SECTION SCALE: 3/16"=1' DETAIL 1 - TYP FTG N.T.S. 2x8 20d AT 12" C/C 37708 SSI�NAL� EXPIRES 08/18/�^'� DETAIL 2 -HEADER N.T.S. DRAWN BY - FC APPROVED BY: CWB I ADDRESS WHERE WORK WILLB DONE: PRWECT DARRElL BATES SHT NWE MAIN BURRING SECTION SHT. NO, S3 DATE: 9/14/06 PROJ. NO.: 2832.0/ 3686 11313 AST 32nd AVE ax36'x1 Z' POLE BUILDING AND DETAILS REV NO � 0 SCALE NOTED P KAN VA Y A SPOKANE UNTY 16'x10' 0/H DOOR SOUTH ELEVATION SCALE: 3/16"=1' EAST ELEVATION SCALE: 3/16"=1' 3068 � C � O .0 37708 �D,t. ��'GISTER�CSS�' �SsjoNaL EXPIRES 08/18 � NORTH ELEVATION SCALE: 3/16"=1' WEST ELEVATION SCALE: 3/16"=1' DRAWN BY: FC APPROVED Y: CWB I ADDRESS WHERE WORK WILL E N PROJECT L BATES sur. u E BUILDING ELEVATIONS L�m AT : 9 14 06 PROJ. NO.: .0 3686 11313AST32nd AV REV. NO.: SCALE: N KAN VA Y A 24'x36'x12' POLE BUILDING SPOKANE COUNTY PROVIDE DIAGRAMS AND ENGINEERING LAYOUTS FOR POOF TRUSSES, BEAMS AND FLOOR SYSTEMS PRIOR TO FRAMING INSPECTIONS CITY COPY THIS BUILDING SUBJECT TO FIELD INSPECTION CORRECTIONS REVIEWED FOR QoDE COMPLIANCE SPOKANE VALL, BUI ING DMSION za oL