Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
1995, 05-04 WA State Energy Code Compliance
WATTSU�^! 5 .4 1991 WA STAT' ENERGY CODE COMPLIANCE REPORT 01 {}1/89 FILE : C : \\JEN13216 .WS HOUSE ID: 4 Piex. ( Mark Jensen ) Site : 132.16 E .31st Court Analyst : TAS Spokane , WA Jurisdiction: Spokane County ( ) - Utility : WWP Homeowner : House Type : Multi--family Floor Area : 3082 ft2 Builder : Jensen Construction Weather Data : Spokane , WA Mark Jensen Climate Zone: 2 ( 509 )455-0332 ------------------------------------ The PROPOSED design *COMPLIES* with 1991 WA State Energy Code . I REFERENCE PROPOSED COMPONENT PERFORMANCE 432 404 8tt'-i/hr-F ENERGY BUDGET 4 . 17 4 .47 kWh/ft2-yr 1 REFERENCE DESIGN Reference Component Value X Area UA On Grade Slab F--0 .540 160ft 86 .4 Glazing ©15% U-0 .400 462 .3 184 .9 Doors U-0 .200 84 .0 16 .8 AG Wall U--0 .044 2174 95 .6 Ceiling , Attic U-0 .031 1541 47 .8 Infiltration ACH--0 .350 26198ft3( 158 .6 ) Reference UA 432 PROPOSED DESIGN COMPONENTS Component Description Value X Area., - UA On Grade Slab R10 4 ' vertical F-0 .480 160ft 76 .8 Glazing @8% **2 glaze vinyl 3/4 " l_1-0 .510 240 .0 122 .4 Doors **:Metal 1-3/4 "urethane raised panel U--0 . 170 84 .0 14 .3 AG Wall R19 INT Lap Wood U--0 .058 2396 139 .0 Ceiling R38 blown Attic STD baffled U-0 .031 1157 35 .9 R38 blown Scissor 4 : 12 STD baffled U--0 .040 384 15 .4 Infiltration Standard Air Sealing ACH--0 .350 26198ft3 '( 158 .6 ) Proposed UA 404 Items in^parentheses-not-included in COMPONENT PERFORMANCE totals . ** Denotes non-standard values -- check calculation of thermal value . WATTSUN 5 .4 1991 WA STATE ENERGY CODE C:CUMPLIANCE REPORT 01. O1/E3 FILE : C :\\JEN13216 .WS HOUSE ID`' "4 Plex ( Mark Jensen ) StrUc Mass Light Frame , Sheetrock walls M- 3 .000 1541 4623 Slab w/carpet w/pad , Sheetrock wall M-- 5 .000 1541 7705 HEATING/COOLING/VENTILATING SYSTEMS PROPOS .D Heating System Type : Electric : Zoned System Efficiency : 100 Modified Efficiency : 100 Design ACH: 0 .60 Design Load( at 66F dt ) : 44590 Btu./hr Total Load: 44590 Btu/hr System Size : 19 .5 kW ( 150% ) Average Annual Heat : 17910 kWh Annual Cost : $ 985 Ventilation System: Integrated Spot & Whole House Cooling System : SEER: 0 .0 ( ) Cooling Load( at 12F dt ) : 2_4396 Btu/hr System Size( %Over ) : 2 .8 tons( 8125 0 ) Annual Cool Requirement : ** kWh/yr Solar Access : Partially Shaded GLAZING ORIENTATION PROPOSED PROPOSED South ft2. North ft2 Southeast : Northwest : 120 .0 East West Northeast : 60 .0 Southwest : 60 .0 Economic and energy consumption estimates are designed for comparative purposes only . Actual cost for heating will vary depending on weather conditions , occupant lifestyle and other factors .