2005, 09-15 Permit App: 05003413 PoolProject Number: 05003413 Inv: I Application Date: 09/15/2005 Page 1 of 2
THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Proiect Information:
Permit Use: 16 X 32 IN GROUND SWIMMING POOL Contact: POOL WORLD INC.
Address: 13524 E SPRAGUE AVE
C - S - Z: SPOKANE, WA. 99216
Setbacks: Front 110 Left: 44 Right: 11 Rear: 5 Phone: (509) 928-6585
Group Name:
Site Information: Project Name:
Plat Key: 006071 Name: MIDILOME EAST 02ND ADD District: F
Parcel Number: 45342.1111 Block: 3 Lot: 11
SiteAddress: 12803 E 36TH AVE Owner: Name: FROEHLE, CRAIG & JODY
Address: 12803 E 36TH
Location:: CSV SPOKANE VALLEY, WA 99206
Zoning: UR -3.5 Urban Residential 3.5
Water District: Hold: ❑
Area: :,289.00 Acres Width: 99 Depth: 125 Right Of Way (ft): 50
Nbr of Bldgs: 1 Nbr of Dwellings: 1
Review Information:
Review
Site Plan Review
Released By:
Plan Review
Originally Released:
09/15/2005 By: Mharnois
Released By:
Sewer Review
Originally Released:
09/15/2005 By: NBENTLEY
ReleasedBy:
#02-0505
Originally Released:
09/15/2005 By: CJJANSSE
Permits:
Operator: CJJ Printed By: CJJ Print Date: 09/15/2005
Project Number: 05003413 Inv: I Application Date: 09/15/2005 Page 2 of 2
THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Contractor: POOL WORLD INC
Address: PO BOX 14927
SPOKANE, WA 99214
Item Description
GAS APPLIANCE >100,000BTU
Contractor: POOL WORLD INC
Address: PO BOX 14927
SPOKANE, WA 99214
Item Description
PRIVATE POOL
STATESURCHARGE
Mechanical Permit
Firm: POOL WORLD INC
Phone: (509) 928-6585
Units Unit Desc Fee Amount
1 NUMBER OF $15.00
Permit Total Fees: $15.00
Swimming Pool -
Firm: POOL WORLD INC
Phone: (509) 928-6585
Units Unit Desc Fee Amount
1 SELECT $50.00
1 SELECT $4.50
Permit Total Fees: $54.50
Notes: .... v.. _ = ..
Payment Summary:
Permit Type
Fee Amount
Invoice Amount
Amount Paid
Amount Owing
Mechanical Permit
$15.00
$15.00
$0.00
$15.00
Swimming Pool
$54.50
$54.50
$0.00
$54.50
$69.50
$69.50
$0.00
$69.50
Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information
contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be
complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of
the provisions of the code or of any other state or local laws or ordinances.
Signature:
Operator: CJJ Printed By: CJJ Print Date: 09/15/2005
Permit Center
owner
S"ORine11707 B Sprague Ave, Suite 106
Name:
�r
C . Phone:,' -
7al ley Spokane Valley, WA 99206
Address:
's
City
S ;vim
'f (509)688-0036 FAX: (509)688-00371°`��^``;
Contractor ' '
E
Community Development www.spokanevalley.ora.com
`
�-
RUS.�� . 1 ..
Fax:
Mechanical Permit Application ❑ Commercial
❑ Residential
City�,
}.
SITE ADDRESS Za7 go �� ,� ,= r
�� -9
License No: W ` C cj
Cf y
usiness License No:
Building
owner
Name:
u / .-
C . Phone:,' -
at r ? _ . 3v Fax
Address:
's
City
S ;vim
State Zi
Contractor ' '
Name:
`
Phon
Fax:
Address:
City�,
State Zi
License No: W ` C cj
Cf y
usiness License No:
Contact
Name:
Phone: ?'✓
DESCRIPTION OF WORK
# OF UNITS X
COST = TOTAL AMOUNT
1
FUEL BURNING APPLIANCE
Equal to or less than 100,000
X
$12.00 =
2
FUEL BURNING APPLIANCE
More than 100,000
D C v X
$15.00 =
3
UNLISTED APPLIANCE Additional Fee
Equal to or less than 400,000
X
$50.00 =
4
UNLISTED APPLIANCE Additional Fee
More than 400,000
X
$100.00 =
5
USED APPLIANCE SEC min. AFUE ratio
Equal to or less than 400,000
X
$50.00 =
6
USED APPLIANCE SEC min. AFUE ratio
More than 400,000
X
$100.00 =
7
BOILER/REFRIGERATION
1 - 100M BTU
X
$12.00 =
8
BOILER/REFRIGERATION
101 - 500M BTU
X
$20.00 =
9
BOILER/REFRIGERATION
501 - 1,000M BTU
X
$25.00 =
10
BOILER/REFRIGERATION
1,001 -1,750M BTU
X
$35.00 =
11
BOILER/REFRIGERATION
More than 1,750M BTU
X
$60.00 =
12
GAS LOG, GAS INSERT, GAS FIREPLACE
X
$10.00 =
13
RANGE
X
$10.00 =
14
DRYER
X
$10.00 =
15
FUEL BURNING WATER HEATER
X
$10.00 =
16
MISC. FUEL BURNING APPLIANCE
X
$10.00 =
17
GAS PIPING each outlet
X
$1.00 =
18
DUCT SYSTEMS
X
$10.00 =
19
VENTILATING FANS
X
$10.00 =
20
AIR HANDLER DOES NOT include ducting)
Equal to or less than 10,000 CFM
X
$12.00 =
21
AIR HANDLER DOES NOT include ducting)
Greater than 10,000 CFM
X
$15.00 =
22
EVAPORATIVE COOLERS
X
$10.00 =
23
TYPE I HOOD
X
$50.00 =
24
TYPE II HOOD
X
$10.00 =
25
HEAT PUMP/AIR CONDITIONER
0-3 TON
X
$12.00 =
26
AIR CONDITIONER
3-15 TON
X
1 $20.00 =
27
AIR CONDITIONER
15-30 TON
X
$25.00 =
28
AIR CONDITIONER
30-50 TON
X
$35.00 =
29
AIR CONDITIONER
More than 50 TON
X
$60.00 =
30
LPG STORAGE TANK
X
$10.00 =
31
WOOD OR PELLET STOVE/INSERT
X
$10.00 =
32
WOOD STOVE - FREE STANDING
X
$25.00 =
33
REPAIR & ADDITIONS
X
$15.00 =
34
VENTILATION SYSTEMS
X
$12.00 =
35
VENTILATION MECHANICAL EXHAUST
X
$12.00 =
36
INCINERATOR -RESIDENCE
X
$19.00 =
37
INCINERATOR- COMMERCIAL
X
$22.00 =
METHOD OF PAYMENT:
[]CASH ❑ CHECK ❑ VISA ❑ MC
r.ARn u
DATE:
EXPIRES:
SUBTOTAL
PROCESSING FEE $35.00
TOTAL PERMIT FEE DUE:
AUTHORIZED SIGNATURE: REVISED 8n26/05
im004397 (1600xl200x24b jpeg)
4. Zones where specific humidity levels are required to
satisfy process needs, such as computer rooms, museums,
surgical suites, and buildings with refrigerating systems, such
as supermarkets, refrigerated warehoused and ice arenas.
1436 Heat Recovery: Fan systems which have both a
capacity of 5,000 cfm or greater and which have a
minimum outside air supply of 70% or greater of the total
air circulation shall have a heat recovery system with at
least 50% recovery effectiveness. Fifty percent heat
recovery effectiveness shall mean an increase in the outside
air supply temperature at design heating conditions of one
half the difference between the outdoor design air
temperature and 65°F. Provisions shall be made to bypass
or control the heat recovery system to permit air
economizer operation as required by Section 1433. Heat
recovery energy may be provided from any site -recovered
or site -solar source.
EXCEPTIONS: 1. Laboratory systems equipped with
both variable au volume supply and variable air volume or
two -speed exhaust fume hoods.
2. Systems serving spaces heated to less than 60°F.
3. Systems which can be shown to use as much energy
with the addition of heat recovery equipment as without it.
4. Systems exhausting toxic, flammable, paint exhaust or
corrosive fumes making the installation of heat recovery
equipment impractical.
5. Type I commercial kitchen hoods.
1437 Electric Motor Efficiency: Design A & 9 squirrel -
cage. T -frame induction permanently wired polyphase
motors of 1 hp or more having synchronous speeds of
3,600,1,800 and 1,200 rpm shall have a nominal full -load
motor efficiency no less than the corresponding values for
energy efficient motors provided in Table 144.
EXCEPTIONS: 1. Motors used in systems designed to
use more than one speed of a multi -speed motor.
2. Motors used as a component of the equipment meeting
the minimum equipment efficiency requirements of Section
1411 and Tables 14-1A through 14-1G provided that the
motor input is included when determining the equipment
efficiency.
3. Motors that are an integral part of specialized process
equipment.
4. Where the motor is integral to a listed piece of
equipment for which no complying motor has been approved.
1438 Variable Flow Systems: For fans and pumps greater
than 10 hp, where the application involves variable flow,
there shall be variable speed drives or variable flow devices
installed. Acceptable variable flow devices include variable
inlet vanes, variable blade pitch and variable fan geometry.
Throttling valves (dampers), scroll dampers or bypass
circuits shall not be allowed.
1439 Exhaust Hoods
1439.1 Kitchen Hoods. Individual kitchen exhaust hoods
larger than 5000 cfm shall be provided with make-up air
sized so that at least 5001a of exhaust air volume be (a)
unheated or heated to no more than 60°F and (b) uncooled
or cooled without the use of mechanical cooling.
EXCEPTIONS: 1. Where hoods are used to exhaust
ventilation air which would otherwise exfiltrate or be
exhausted by other fan systems.
Effective July 1, 2005
2004 Edition
2. Certified grease extractor hoods that require a face
velocity no greater than 60 fpm.
1439.2 Fume Hoods: Each fume hood in buildings with
fume hood systems having a total exhaust rate greater than
15,000 cf n shall include at least one of the following
features:
a. Variable air volume hood exhaust and room supply
systems capable of reducing exhaust and make-up air
volume to 50% or less of design values.
b. Direct make-up (auxiliary) air supply equal to at least
75% of the exhaust rate, heated no warmer than 2°F below
room set point, cooled to no cooler than. 30F above room set
point, no humidification added, and no simultaneous
heating and cooling used for dehumidification control.
c. Heat recovery systems to precondition make-up air in
accordance with Section 1436, without using any exception.
d. Constant volume fume hood designed and installed to
operate at less than 50 fpm face velocity.
SECTION 1440 — SERVICE WATER HEATING
1441 Water Heater Installation: Electric water heaters in
unconditioned spaces or on concrete floors shall be placed
on an incompressible, insulated surface with a minimum
thermal resistance of R-10.
1442 Shut-off Controls: Systems designed to maintain
usage temperatures in hot water pipes, such as circulating
hot water systems or heat traced pipes shall be equipped
with automatic time switches or other controls to torn off
the system during periods of non-use.
1443 Pipe Insulation: Piping shall be thermally insulated
in accordance with Section 1415.1.
SECTION 1450 — HEATED POOLS
1451 General: The requirements in this section apply to
"general and limited use pools" as defined in the
Washington Water Recreation Facilities Regulations
(WAC 246-260).
1452 Pool Water Heaters: Heat pump pool heaters shall
have a minimum COP of 4.0 determined in accordance with
ASHRAE Standard 146, Method of Testing for Rating Pool
Heaters. Other pool heating equipment shall comply with
the applicable efficiencies in Tables 141A through 144G.
1453 Controls: All pool heaters shall be equipped with a
readily accessible ON/OFF switch to allow shutting off the
operation of the heater without adjusting the thermostat
setting. Controls shall be provided to allow the water
temperature to be regulated from the maximum design
temperature down to 65°F.
1454 Pool Covers: Heated pools shall be equipped with a
vapor retardant pool cover on or at the water surface. Pools
heated to more than 90°F shall have a pool cover with a
minimum insulation value of R-12.
85
I I I
I I I
I I I
I I I
I i
DETAIL A
WALL BRACE ASSEMBLY DETAIL
1 1/2" x 43' x 11 GA.
GALVANIZED ANGLE
14 GA. GALVANIZED
STEEL WALL PANEL
42"
WALL BRACE ASSEMBLY
2' BOTTOM MATERIAL
i-`�
.I \\ rvv,cR-7LK/,vI.,_UNOISTURBED EARTH
7 1/2 x 4 1/2 x 12"
BEARING PLATE
REBAR
1 1/2' x 24' x 14 GA.
GALVANIZED ANGLE
NOTE: BACKFILL TO BE SAND, GRAVEL,
OR OTHER NON EXPANSIVE MATERIAL
B J DETAIL A A
`\ -T-
1 K
-------------- / G ------------
c DF
* NO DIVING BOARD ALLOWED
0
uD
POOL
SIZE I
A
I B
I C
I D
E
F I
G
H
J
K
L
12 x
24* 1
12
24
8
76
6
26
6
26
7'
Y67
2610
14 x
26*
14
26
10
76
6
26
6
26
9
3
296 3
8
16 x
32
16
32
8
14
6
4
8
4
8
3
35 9 1
4
16 x
36
1 6
36
12
14
6
4
8
4
8
3
39'4 3/4"
18 x
36 Tl8
36
12
14
6
4
8
4
10
3 Q
40 3
20 x
40
20
40
14
14'F8'
4
8
4
12
6
448 5/8"
F-�� r�
-NOTE-
THESE DIG DIMENSIONS COMPLY WITH THE NATIONAL SPA AND POOL INSTff FfE SUGGESTED MINIMUM
STANDARDS FOR RESIDENflAL POOLS. WARNING — DO NOT ONE IN THE 2E � OW END- IF DIVING BOARDS
OR SLIDES ARE TO BE USED WITH THESE POOLS PLEASE CONSULT THE MANUFACTURE S INSTRUCTIONS
AND THE NATIONAL. SPA AND POOL INSTITUTE'S MINIMUM STANDARDS PRIOR TO INSTALLING DIVING
BOARDS OR SLIDES ON THESE POOLS. FOR INFORMATION CONSERNING NSrn ;MINIMUM STANDARDS, WRITE:
NATIONAL SPA AND POOL INSTITUTE. 2111 EISENHOWER AVENUE. ALE(ANDRLA /VA 22314 (703) 838-0083
1 I IDRNAW: KK I'LE I''^"I- RECT6RC
CARDINAL SYSTEMS
269 & RT. 61 (717 385-4733
SCHUYLKU HAVEN, PA. f (717) 385 1318 FAX
DATE4-8-91
Tm-L*, CORNERS
1 I IDRNAW: KK I'LE I''^"I- RECT6RC
mummomm
16X32 POOL
AUTO COVER
8' FLYTE DECK
I
DECK LEVEL;
TT
1
2'-6"
8'-0"
WATER LEVEL
MAXIMUM
IMPORTANT 2'-6" 7'-6"
BOLT SET -BACK 7'-6" MINIMUM
A B C
1 4'-0" 1 6-0" 1 14'-0"
32'-0"
SWIMMING POOL. LAYOUT
0
8'-0"
•
E
ANSI / NSPI-5 DIMENSIONS
POOL BOTTOM DIMENSIONS
Scale: 1/4" = 1' on 11" x 17" Paper
1
m
u
V m
z N c
O m -
_j
M i
0��
u
°o u
J a
0 Nv
0 s I
IL
E
3
N
N_
=a
003�-
O N �
�oav
U a y
Q
Q m N L
av c u
sheetnur
SP -1
SCALE POOL DRAWING FOR:
Name
SPECIFICATIONS:
Make - Model
It is understood anc
that this drawing ar