1993, 12-21 Permit: 93011996 ResidenceSPOKANE COUNTY DEPARTMENT OF BUILDINGS
WEST 1026 BROADWAY • SPOKANE, WA 99260-0050
(509) 456-3675
SITE INFORMATION PROJECT INFORMATION
- .�. _ - -
SITE ADDRESS: 11105 E 38TH AVE PROJECT NUMBER: 93011996 ISSUE DATE: 12/21/93
SPOKANE WA 99206 1
PERMIT USE: RESIDENCE W/GARAGE - GAS
PARCEL NUMBER: 45332.9130
APPLICANT: KERR-BUILT, INC
SUBDIVISION: SP -743-92 PHONE: 509 625 4924
LOT: A BLOCK: ZONE: UR -3.5 ADDRESS: 000000 PO BOX 14647
9 SPOKANE WA 99214
INSPECTOR: REED OCKEY
WATER DIST: MODEL
OWNER: KERR-BUILT, INC
PHONE: 509 625 4924
ADDRESS: PO BOX 14647
SPOKANE WA 99214
BUILDING PERMIT
CONTRACTOR
KERR-BUILT INC
LICENSE #: KERRBI*151PS
NEW BUILDING
DIM.= 35 X 53 2 STORIES
SQ FT = 2033
BASEMENT U R-3 VN 1003
DECK R-3 VN 32
GARAGE M-1 VN 567
RESIDENCE R-3 VN 1030
TOTAL VALUE: $72,379.00
RADON MONITOR 1
SALES TAX 1
RESIDENTIAL VALUATION 518.00
STATE SURCHARGE 4.50
RESIDENTIAL SURCHARGE 93.24
TOTAL PERMIT FEE $629.32
CONTRACTOR
UNKNOWN
LICENSE #: UNKNOWN
GAS APPLIANCE<=100,000B
GAS WATER HEATER
GAS PIPING
VENTILATING FANS
TOTAL PERMIT FEE
PAYMENT SUMMARY
PAYMENT DATE RECEIPT# PAYMENT AMOUNT
------------ -------- --------------
12/21/93 00014230 $797.32
TOTAL FEES AMOUNT PAID AMOUNT OWING
$797.32 $797.32 $.00
ISSUED PERMIT BY: JULIE SHATTO
CONTACT: RON MOTES
SETBACKS -> FRONT: 25
LENDER NAME:
PHONE:
ADDRESS:
PERMIT(S)
1
1
2
3
$54.00
CONTRACTOR
UNKNOWN
LICENSE #: UNKNOWN
TOILETS/BIDETS
TUBS
SHOWERS
SINKS
DISH WASHERS
CLOTHES WASHER
GARBAGE DISPOSAL
FLOOR DRAINS
SEWAGE EJECTOR
WATER USING DEVICES
TOTAL PERMIT FEE
PHONE: 509 625 4924
LEFT: 10 RIGHT: 25 REAR: 30+
2
1
1
3
1
1
1
1
1
2
$84.00
Nom
CONTRACTOR
OWNER
LICENSE #:
APPROACH INSPECTION 1
APPROACH PERMIT 1
TOTAL PERMIT FEE $30.00
t
NOTICE
It is the responsibility of the permittee, not Spokane County, to see to it that the use described on the front of this permit complies with applicable codes
and requirements and that required inspections are requested. Failure to request required inspections and obtain the necessary approvals prior to
progressing beyond the point where inspections are required may necessitate removal of certain parts of the construction at the owner's/permittee's
expense. At a minimum, the following inspections ARE REQUIRED by County Code:
FOOTING - when forms and reinforcement are in place and prior to placement of concrete.
NOTE: This inspection includes review of the structure's setbacks from property lines. Minimum setbacks are established by County zoning
regulations. Typically, side and rear yard setbacks are measured from property lines, while setbacks for yards abutting streets are measured from
the property line or the center line of the roadway right-of-way, whichever provides the greater setback from the center line of the roadway
right-of-way. Curb lines and fence lines are not necessarily indicative of property lines. In some residential areas, the County can own as much
as 20 feet of right-of-way between your property and the actual improved street/curb. The responsibility to comply with applicable setback
provisions lies solely with the permittee —neither Spokane County nor its authorized representatives assume any responsibility for the verification
or location of your property lines. Please verify their location prior to locating your structure. Failure to properly locate the structure may require
its relocation at the owner's/permittee's expense.
2. FOUNDATION - when forms and reinforcement are in place and prior to placement of concrete. (Blocking for a manufactured home is
required to be inspected prior to the installation of skirting.)
3. FRAMING - after all framing, bracing and blocking is in place, and prior to concealing.
4. INSULATION - prior to the installation of drywall.
5. PLUMBING - after rough -in, before covering, and final.
MECHANICAL - rough -in of piping, before covering, metal chimneys before concealment, and final.
FINAL - when complete and prior to occupancy and/or use. Please provide 24 hours notice.
NOTE: In addition to inspection of the structure, this inspection includes review of site improvements (typically depicted on the approved site
plan) required by ordinance or as a condition of approval of this permit. Items such as the installation of fire hydrants, fire department access,
on-site drainage ("208 swales"), road improvements, parking, and landscaping are common requirements of a permit/site plan which must
be completed prior to final approval of a building or issuance of a Certificate of Occupancy.
In addition to the above any plumbing or mechanical systems or materials which would be concealed by framing, drywall, concrete, etc., must be
inspected prior to cover. Check with the department for "special inspections" in conjunction with commercial projects.
CALL 456-3675 FOR INSPECTIONS.
TO INSURE PROMPT SERVICE, PLEASE GIVE 24 HOUR NOTICE.
YOUR INSPECTOR IS
UNDER CERTAIN CIRCUMSTANCES, PARTS OF YOUR PROJECT MAY REQUIRE INSPECTIONS FROM OTHER AGENCIES:
• Road cuts for utilities or drives, County Engineer's Office
456-3600
or State Department of Transportation
456-3000
• On-site waste disposal system, Spokane County Health District
324-1560
• Construction in a flood plain, County Engineer's Office
456-3600
Sewer connection, County Utilities Department
456-3604
or City Public Works Department
625-6300
• Electrical wiring, State Department of Labor and Industries
324-2640
EXPIRATION
Unless otherwise noted, this permit will be considered null and void by limitation of the work authorized by the permit if not commenced or is stopped
for a period of 180 days, unless a written request for an extension of the permit is received and approved by the Building Official prior to expiration.
At a minimum an inspection should be requested at least once every 180 days to assure the validity of the permit. A permit may be renewed within
one year of the date of expiration for one-half the original fee, subject to certain limitations—please call us if you have any questions.
MISTAKES?
If you think we've made an error in processing this permit or in conducting inspections pertaining to it, or find erroneous information in the permit,
please bring it to our attention immediately by filing a written request for correction within 10 working days of discovery. All such requests should be
directed to the Department of Buildings at the address found on the face of this permit.
I certify that I have examined this permit/ application, state that the information contained in it and submitted by me or my agent to compile said
permit/ application is true and correct, and authorize Spokane County to proceed with processing. In addition, I have read and understand the
INSPECTION REQUIREMENTS/NOTICE provisions included herein and agree to comply with same. All provisions of laws and ordinances
governing this type of work will be complied with whether specified herein or not. I understand that the issuance of this permit/ application and any
subsequent inspection approvals or Certificates of Occupancy shall not be construed to give authority to violate or cancel the provisions of any
state or local law regulating construction, or as a warranty of conformance with the provisions of any state or local laws regulating construction.
SIGNATURE OF-/�`��� APPLICATION l�/'n jt
OWNER OR AGENT' %-1'_�� � DATE
DDI Architecture & Planning for: Kerr Built, Inc.
N. 8605 Division Plan # 1030 SE
Spokane, Wash. 99208 August 13, 1993
(509) 467-6200
-------------------------------------------------------------------
2x6 Wall Construction (c) DDI Architecture &
Planning
R-19 Wall Insulation
66
0
Floors over unheated spaces.....
27
R-19 Wall Insulation -Basement R-19
Insulation -Floors
over
Framed Walls ...................
R-38 Ceiling Insulation unheated
0.062
spaces
7169.184
Glazing .........................
NW Alum Series 1050 Vinyl Wdws
0.6
66
10406.88
Entry Door ......................
-------------------------------------------------------------------
PROPOSED CONSTRUCTION
Sq.Ft.
U Value Delta
T BTU
Loss
-------------------------------------------------------------------
Ceiling - Flat ..................
974
0.026
66 1499.784
Concrete Floor ..................
Ceiling - Tapered ...............
156
0.04
66
411.84
Ceiling - Vaulted ...............
0
0.03
66
0
Floors over unheated spaces.....
27
0.05
66
89.1
Framed Walls Main Floor.........
1056
0.05
66
3484.8
Main Floor Windows ..............
90
0.46
66
2732.4
Sliding Glass Doors .............
40
0.52
66
1372.8
Entrance doors ..................
• 38
0.4
66
1003.2
Infiltration - Main Floor.......
8240
0.012
66
6526.08
Framed Walls - Basement.........
438.5
0.05
60
1315.5
Basement Windows ................
71.5
0.46
60
1973.4
Basement Entrance Doors.........
18
0.4
60
432
Basement Sliding Glass Doors....
0
0.52
60
0
Concrete Foundation Walls.......
528
0.05
10
264
Concrete Floor ..................
1003
0.26
10
2601.8
Basement Infiltration @ 60 deg..
4012
0.012
60
2988.64
Basement Infiltration @ 10 deg..
4012
0.01
10
401.2
0
TOTAL PROPOSED HEAT LOSS ------------------------------ > 27002.54
......................................
Wash State Energy Code - Maximum Allowable - Gas Heat
..................................................................
Ceilina ......................... 1030 0.031 66 2101.38
Ceiling - Vaulted ...............
0
0.034
66
0
Floors over unheated spaces.....
27
0.029
66
51.678
Framed Walls ...................
1752
0.062
66
7169.184
Glazing .........................
262.8
0.6
66
10406.88
Entry Door ......................
56
0.4
66
1479.4
Concrete Foundation Walls.......
528
0.05
10
264
Concrete Floor ..................
1003
0.42
10
4212.6
Infiltration - Main Floor.......
8240
0.012
66
6526.08
Basement Infiltration @ 60 deg..
4012
0.012
60
2888.64
Basement Infiltration @ 10 deg..
4012
0.01
10
401.2
0
TOTAL ALLOWABLE BTU LOSS ------------------------------ > 35506.04
DIFFERENCE ------------ > 8503.498
f. From. Table 5-1 W.S.E.C.
SP ECI El AT1O74S
TYFE CF SEWAGE S'f'.70-1: .
L'IrlE fkl_ Og Ur_ii.lE inn!
TP.EriCii "MR?: 341;ti__ _ .__ _ -5 :._
D'PTSI rR:.•I 34.7 i'ME cia_
ii Sf_161:1.- ''. El 9,•5-1T.A1
OF SEIV.Gli iSTEM:
OTHER: /
SIVA"
•
- • •
-a6 ta
'e40,4;
4‘t,‘39.
•
•
LS20,CIAL"
SEPTIC
• . •
•
- -
• 5 -0.0"
. .
. - -
••gr2:
• g e:
• Jr ..15113Ariq -
• OPAV
26-00=
.
• -..5PC1KA
".•