1992, 06-25 Permit: 92004541 Residence SPOKANE COUNTY,,DEPARTMENT OF BUILDINGS
W. 1303 BROADWAY AVENUE
SPOKANE,WASHINGTON 99260
(509)456-3675
I certify that I have examined this permit/application,state that the information contained in it and submitted by me or my agent to compile said permit/application is true
and correct, and authorize Spokane County to proceed with processing. In addition, I have read and understand the INSPECTION REQUIREMENTS/NOTICE
provisions included herein and agree to co ply with same.All provisions of laws and ordinances governing this type of work will be complied with whether specified
herein or not.I understand that the issua --of this permit/application and any subsequent inspection approvals or Certificates of Occupancy shall not be construed to
give authority to violate or cancel th- : . sions of any state or local law regulating construction,or as a warranty of conformance with the provisions of any state or local
laws regulating construction.
SIGNATURE OF (.._ // APPLICATION / r' S / -2__- �f �OWNER OR AGEN _� - C DATE (((ppp
PROJECT NUMBER= 92004544 ISSUED PERMIT DATE= 06/25/92 PAGE= 01
**************************** PERMIT INFORMATION ****************************
SITE STREET= 42225 E 38TH AVE PARCEL;= 45331 .9004
ADDRESS= SPOKANE WA 99206
PERMIT USE= RESIDENCE -- NATURAL GAS
PLATO= 005026 PLAT NAME= MIDILOME 6TH ADD
BLOCK= 6 LOT= 8 ZONE= UR-•3.5 DISTO=
AREA= F/A= F WIDTH= 100 DEPTH= 121 R/W= 50
OF BLDGS= 4 DWELLINGS= i WATER DIST = MODEL
OWNER= GREMY INC PHONE= 509 924 9406
STREET= 12212 E SIOUX CIR
ADDRESS= SPOKANE WA 99206
CONTACT NAME= GREMY INC -• FRANK COBB PHONE NUMBER= 509 924 9406
BUILDING SETBACKS: FRONT= 30 LEFT= 8 RIGHT= 30 REAR= 47
******************************* BUILDING PERMIT ****************************
CONTRACTOR= GREMY INC PHONE= 509 924 9406
STREET= 12212 E SIOUX CIR
ADDRESS= SPOKANE WA 99206
NEW= X REMODEL= ADDITION= CHANGE OF USE=
DWELL UNITS= OCCUP. LD= BLDG HGT= 13 STORIES=
BLDG W X D = 52 X 52 SQ FT= 2711 SPRINKLER= N
REQ PARKING= OHANDICAP= CRITICAL MAT= N
DESCRIPTION GROUP TYPE SQ FT VALUATION
BASEMENT U R-3 VN 1350 14850.00
DECK R-3 VN 144 720.00
GARAGE M-i VN 470 3760.00
RESIDENCE R-3 VN 1 361 73494.00
ITEM DESCRIPTION QUANTITY FEE AMOUNT
RESIDENTIAL VALUATION Y 608.00
STATE SURCHARGE V 4.50
RESIDENTIAL SURCHARGE V 109.44
******************************* MECHANICAL PERMIT **************************
CONTRACTOR= R & R HEATING & AIR COND INC PHONE= 509 484 4405
STREET= 1723 E FRANCIS AVE
ADDRESS= SPOKANE WA 99207
ITEM DESCRIPTION QUANTITY FEE AMOUNT
GAS WATER HEATERi 10.00
GAS HTG EQUIP< i00,000?BTU i 12.00
GAS PIPING 3 3.00
GAS LOG i 10.00
***************************** PLUMBING PERMIT ******************************
CONTRACTOR= PIPER PLUMBING & HEATING PHONE= 509 534 6986
STREET= PO BOX 3992
ADDRESS= SPOKANE WA 99220
ITEM DESCRIPTION QUANTITY FEE AMOUNT
TOILETS 2 12.00
SINKS 2 12.00
SHOWERS i 6.00
BATH TUBS i 6.00
KITCHEN SINKS i 6.00
DISH WASHERS i 6.00
GARBAGE DISPOSAL I 6.00
CLOTHES WASHER 1 6.00
FLOOR DRAINS 1 6.00
SPOKANE COUNTY DEPARTMENT OF BUILDINGS
W. 1303 BROADWAY AVENUE
SPOKANE,WASHINGTON 99260
(509)456-3675
I certify that I have examined this permit/application,state that the information contained in it and submitted by me or my agent to compile said permit/application is true
and correct, and authorize Spokane County to proceed with processing. In addition, I have read and understand the INSPECTION REQUIREMENTS/NOTICE
provisions included herein and agree to comply with same.All provisions of laws and ordinances governing this type of work will be complied with whether specified
herein or not.I understand that the issuance of this permit/application and any subsequent inspection approvals or Certificates of Occupancy shall not be construed to
give authority to violate or cancel the provisions of any state or local law regulating construction,or as a warranty of conformance with the provisions of any state or local
laws regulating construction.
SIGNATURE OF APPLICATION
OWNER OR AGENT DATE
PROJECT NUMBER= 9200454i ISSUED PERMIT DATE= 06/25/92 PAGE= 02
******************************* PAYMENT SUMMARY ************************* **
PAYMENT DATE RECEIPT* PAYMENT AMOUNT
06/25/92 4889 822.94
TOTAL DUE= .00 TOTAL PAID= 822.94
PERMIT TYPE FEE AMOUNT AMOUNT PAID AMOUNT OWING
BUILDING PERMIT 72i .94 72i .94 .00
MECHANICAL PRMT 35.00 35.00 .00
PLUMBING PERMIT 66.00 66.00 .00
822.94 822.94 .00
PROCESSED BY : FORRY, JEFF
PRINTED BY : WENDEL, GLORIA
******************************** THANK YOU *********************************
'
• -
COMBINED COMBUSTION AND VENTILATION AIR
FOR RESIDENTIAL GAS FIRED FURNACES
(4R.C.:17716-4____CIPI:37— •
744
Address .r c)
i -
Project #
Furnace Model #
BTU Input
X 30 L �'rMIA 141---1 cwt
rrrr i 350
Formula for A.C.H.:
1,2otalsg,jukstuNt= x A.C.H. C.F.M.
60 min,
Formula for Combustion Air:
0.4 C.F.M. x Each 1,000 B.T.U. of Furnace Input = Combustion Air Required
C.F.M. for Combustion Air
.- 35 } Minimum C.F.M. at .35
Maximum C.F.M. at .50 IS I
C.F.M. Capacity of Round Metal Duct
5" - 65 $" - 230
6" - 100 9" - 300
7" - 160 10" - 400
Size of Duct Used — „
Size of Each Opening as Required for Confined Space
Submitted By R & R HEALING & A/C Approv. W
F . 1723 Francis
Date
Spokane, WA 99207