Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
2005, 10-11 Permit App: 05003647 Addition
Project Number: 05003647 Inv: I Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 10/11/2005 Page 1 of 2 Project Information: Permit Use: ADDITION TO SFD- Contact: S & S CONSTRUCTION BEDROOM/KITCHEN/GARAGE Address: 9606 E ARCHERY C - S - Z: SPOKANE, WA 99206 Setbacks: Front 120 Left: 80 Right: 30 Rear: Phone: (509) 922-6390 Group Name: Site Information: Project Name: Plat Key: Name: PONDEROSA 02ND ADD District: Sout Parcel Number: 44051.0602 Block: Lot: SiteAddress: 10420 E 44TH AVE Owner: Name: COLLINS, ANTHONY J Address: 12906 E 22ND AVE SPOKANE VALLEY, WA 99216 Location:: CSV Zoning: UR -1 Urban Residential -1 Water District: Hold: ❑ Area: 70,400 Sq Ft Width: 0 Depth: 0 Right Of Way (ft): 0 Nbr of Bldgs: 0 Nbr of Dwellings: 0 Review Information: Review Site Plan Review Originally Released: 10/11/2005 By: CJJANSSE Plan Review Septic System Review Permits: Originally Released: 10/11/2005 By: TMELBOU Released Rpt (3) BEDROOMS APPROVED FOR SEPTIC - L.HALSEY -11/11/05 Originally Released: 10/11/2005 By: m_turbak Operator: CJJ Printed By: MT Print Date: 10/11/2005 Project Number: 05003647 Inv: 7 Application • THIS IS NOT A PERMIT Penalties will be assessed for commencing work without, a permit Building Permit Contractor: S & S CONSTRUCTION Firm: RAY SCHROEDER / S & S CONST Address: 9606 E ARCHERY Phone: (509) 922-6390 SPOKANE, WA 99206 Date: 10/11/2005 Page 2 of 2 This Application: Total Project: Description t T e Notes Sa Ft Valuation Sq Ft Valuation RESIDENCE R-3 VB REMODEL 0 $55,000.00 0 $55,000.00 Item Desert tion RESIDENTIAL PERMIT FEE STATE SURCHARGE RESIDENTIAL PLAN REVIEW Totals: 0 $55,000.00 0 $55,000.00 Units Unit Desc Fee Amount 1 SELECT $678.75 1 SELECT $4.50 1 SELECT $271.50 Permit Total Fees: Plumbing Permit $954.75 Contractor: ALPHA PLUMBING & HEATING Firm: ALPHA PLUMBING Address: 13615 E TRENT AVE Phone: (509) 535-0727 SPOKANE, WA 99216 Item Description Units Unit Desc Fee Amount TOILETS/BIDETS 3 NUMBER OF $18.00 SINKS 3 NUMBER OF $18.00 SHOWERS 2 NUMBER OF $12.00 TUBS 2 NUMBER OF $12.00 DISH WASHERS 1 NUMBER OF $6.00 CLOTHES WASHER 1 NUMBER OF $6.00 Permit Total Fees: $72.00 Notes: Payment Summary: Pemti[ Tvoe Fee Amount Invoice Amount Amount Paid Amount Owing Building Permit $954.75 $954.75 $0.00 $954.75 Plumbing Permit $72.00 $72.00 $0.00 $72.00 $1,026.75 $1,026.75 $0.00 $1,026.75 Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: CJJ Printed By: MT Print Date: 10/11/2005 Project Number: 05003647 Inv: 1 Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 10/05/2005 Page 1 of 2 Project Information: Permit Use: ADDITION TO SFD- BEDROOM/KITCHEN/GARAGE Setbacks: Front 120 Left: 80 Right: 30 Rear: Site Information: Plat Key: Contact: S & S CONSTRUCTION Address: 9606 E ARCHERY C - S - Z: SPOKANE, WA 99206 Phone: (509) 922-6390 Group Name: Project Name: Name: PONDEROSA 02ND ADD District: Sout Parcel Number: 44051.0602 Block: SiteAddress: 10420 E 44TH AVE Location:: CSV Zoning: UR -1 Urban Residential -1 Water District: Area: 70,400 Sq Ft Width: 0 Nbr of Bldgs: 0 Nbr of D'- s: 0 Review Information: Review <6") \\' Site Plan Review -t _ Plan Review Septic System Review hep g_e_aovsis Lot: Owner: Name: COLLINS, ANTHONY J Address: 12906 E 22ND AVE SPOKANE VALLEY, WA 99216 Hold: ❑ Depth: 0 Right Of Way (ft): 0 ( Released By: Released By: Released By ___�_.__ (�54 /0 fi1 ll 0�i Permits: Building Permit Contractor: S & S CONSTRUCTION Address: 9606 E ARCHERY Phone: (509) 922-6390 SPOKANE, WA 99206 Firm: RAY SCHROEDER / S & S CONST Operator: CJJ Printed By: CJJ Print Date: 10/05/2005 Project Number: 05003647 Inv: I Application THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Date: 10/05/2005 Page 2 of 2 Notes: Payment Summary: Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: CJJ Printed By: CJJ Print Date: 10/05/2005 10/11/2005 11:00 5093241567 SRHD EHS Project Number: 05003647 Inv: I Application 1 FIIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Leiter Information ... Permit Use: ADDITION TO SFD- Contact: S & 6 CONSTRUCTION BEDROOM/KITCHEN/GARAGE Address: 9606E ARCHERY C - S - Z: SPOKANE, WA 99206 Phone: (509) 922-6390 Group Name: fjjg information; Projecs Name: b,:; Plat Key: Name: PONDEROSA 02ND ADD District: Sout"'ty Parcel Number: 44051.0602 Brock Lot; SiteAddress: 10420 E 44TH AVE Owner: Neese: COLLINS, ANTHONY.f'i'U;c,//y, Address: 12906 E 22ND AVE pCii s!1 /4z Loudon:: CSV SPOKANE VALLEY, WA 9921ai it%,V NS4LTy Zoning: UR -1 - Urban Residential -1 Weser District: Hold 0 Aram 70,400 Sq Ft Width: 0 Depth: 0 Right Of Way (ft): 0 Nbr of Bldgs: 0 Nbr of Dwellings: 0 Bev(1ew In (enaction: s.memuort.wmao ., Date: 10/03/2005 PAGE 01/01 Page 1 of 2 Setbacks:Front 120 Left: 80 Rigbt 30 Rear: Review Site Plan Review MEM 14lEldai81H)0.Y�,.ld,//�d�^..n_f4::: •r yn., te:��%�..i�iV•"�9,��1�,.< Plan Review R��F1S'hOO klU; Septic System Review Perm DArar•ItaCtel(3) ,®6•21 Contractor: S & 5 CONSIRUCTION Address: 9606 E ARCHERY SPOKANE, WA 99206 Funding Permit // Firm: RAY SCHROEDER / S & S CONST s4" g� Pbone: (509) 922-6390 estend V 4rN %y Operetar: CJJ Printed By: CJI Print Date: 10/05/2003 £0,T0'd L9STOZ£ 01 OCT 11 2005 12:12 8d OZ:90 S00Z TT 1ZO 509324156? PRGE.01 Permit Center Spokane 11707 E Sprague Ave, Suite 196 .0,0 Valley Spokane Valley, WA 99206 .7 (509)688-0036 FAX: (' ° 8 Community Development wN; .spokanevallev.or Residential Construction Permit Application CS\ ❑ Ne7\C At> tion o Accessory Bldg i \clic' >< ><on/Remodel o Deck o I ther: SITE ADDRESS G 1 c c( -2._a L� ASSESSORS PARCEL NO: LEGAL DESCRIPTION: Building ov Name: 0 \." c � (N S Address: (0 !C W Lk( t City:. U . Zip: Phone: Fax: ContaS,t�Pells Name: Phone: - — / s Contractor..:. Name: 5 Address: cJ (o d (p E A- fc L -+r Zip: (D Phone 2 _ li` O F©axe C� Lic N �(c*Je( 1 ✓ `exp.7Date: t /i4/zt97 City: 5 _ 0 City Business Lic No: Describe the scope of work in detail: Cost of Project• •(write N/A if not applicable)********************** --- ---11./11U........" -- ------- 1 UV 111V HEIGHT TO PEAK: ��1u� LV = ,v.. ..v...j......�.• DIMENSIONS: !6x26 23'cZ2 izxZit- # OF STORIES: TOTAL HABITABLE SPACE: MAIN FLOOR TO SQ4\4 FTG: 2"" FLOOR SQ. FTG: UNFIN BASEMENT SQ. FTG: IMPERVIOUS SURFACE AREA: FINISHED BASEMENT SQ. FTG: GARAGE SQ. FTG: A 1 --2-SS-c- �s DECK/COV. PATIO SQ. FTG: 30% SLOPES ON PROPERTY: # OF BED OMS: CONSTRUCT 0 N TYPE: HEATSQURCE:WO 74? SEWE OR ? CPQ DISCLAIMER The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling, the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit C: nter. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or local laws, co• goordin �• ces. ) Plans or additional information may be required to be submitted, and subsequently approved before i this applicatio • - pr Signature Date Method of Payment: (Faxed permit applications will only be accepted with major bankcard) 0 Cash 0 Check ❑ Mastercard 0 VISA Bankcard #: Expires: VIN#: Authorized Signature: REVISED 8/25/2005 0 Other Community Development Permit Center 11707 E Sprague Ave, Suite 106 Spokane Valley, WA 99206 (509)668-0036 FAX: (509)688-0037 www.sookanevallev.ore.com Residential Plan Submittal Minimums ❑ Completed Building, Plumbing & Mechanical application with: Accurate address, Parcel Number and/or Legal Description, description of work, owner and contractor information, signature, and date. ❑ Two sets of plans including Site Plan, elevations, floor plans, foundation plans With details, roof plan, framing plans & details. ❑ Show the height of any proposed buildings or accessory structures. ❑ Floor plan for each floor: Dimension to scale (minimum 1/8°) and label each Room (including sq. footage of house and garage on plans) Show each level of existing house and square footage of any additions. ❑ All braced wall panel types: show locations and details of installation, including engineered design. ❑ Egress windows: Provide at least one window or exterior door approved for Emergency escape or rescue from a basement and in every room for sleeping. o Smoke detector locations o 22' X 30° attic access location ❑ 18" X 24° crawl space access: ❑ One-hour separation detail: between house and garage o Floor framing details: Joist type size, spacing and installation details ❑ Roof framing plan and details ❑ Furnace and hot water heater location. ❑ All header locations: type, size, and connections ❑ Foundation plan ❑ Insulation information st i Community Development Permit Center 11707 E Sprague Ave, Suite 106 Spokane Valley, WA 99206 (509)688-0036 FAX: (509)688-0037 www okanevallev.ore oont Plumbing Permit Application ❑ Commercial PERMIT NUMBER: PERMIT FEE: o Residential SITE ADDRESS Building owner DESCRIPTION OF WORK # OF UNITS X Name: Phone: TOTAL AMOUNT Fax TOILETS Address: City State Zip Contractor 2 URINALS Name: Phone: Fax: 3 Address: City State Zip License No: City Business License No: SHOWERS (PER TRAP) BATH, STALL, ON-SITE BUILT Contact, .. .. $5.00 = Name: Phone: LAVS/BASINS, BAR, FLOOR KITCHEN, LAUNDRY, UTILITY, JANITOR. PHOTO. X-RAY, FOOD. PREP/CULINARY MEAT X AUTHORIZED SIGNATURE: REVISED V26/05 DESCRIPTION OF WORK # OF UNITS X COST % TOTAL AMOUNT 1 TOILETS WATER CLOSET. BIDETS X $8.00 2 URINALS X $6.00 3 TUBS 9- X $6.00 = 4 SHOWERS (PER TRAP) BATH, STALL, ON-SITE BUILT 2' X $5.00 = 5 SINKS LAVS/BASINS, BAR, FLOOR KITCHEN, LAUNDRY, UTILITY, JANITOR. PHOTO. X-RAY, FOOD. PREP/CULINARY MEAT X $6.00 6 DISHWASHER 1 X $6.00 7 CLOTHES WASHER $ X $5.00 = 8 GARBAGE DISPOSAL X $8.0O 9 WATER SOFTENER X $6.00 = 10 ELECTRIC HOT WATER TANK NOTE: IF GAS, SEE MECHANICAL X $B.00 = 11 FLOOR DRAINS AREA CASE, COIL, TRENCH. CONDENSATE X $B.00 = 12 ROOF DRAINS/OVERFLOW DRAINS X $6.00 = 13 FOUNTAINS, DRINKING X $6.00 14 WATER PIPING/DRAIN-IN WASTE. VENT, PLUMBING, REVERSAL NSTALLATION, ALTERATION, REPAIR. REVERSALS X $6.00 15 SEWAGE EJECTOR GRINDER, SUMP PUMP X $5.00 = 16 WATER USING DEVICE ICEAN/OR COFFEE MAKER, HOSE BIB, STEAMER PROOFER, CARBONATOR, SWAMP COOLER X $6.00 = 17 CROSS CONNECTION DEVICE VACUUM BREAKER. CHECK VALVE, AND R.P.BP.D. FOR VATS, TANKS, BOILERS X MOO = 16 INTERCEPTORS GREASE TRAP, SAND TRAP, CHEMICAL HOLDING TANK X $6.00 = 19 - MEDICAL GAS (per outlet) NITROUS. OXYGEN X $6.00 = 20 MISCELLANEOUS PLUMBING FIXTURE X $6.00 21 PRIVATE SEWAGE DISPOSAUSYS X $20.00 = 22 INDUSTRIAL WASTE INTERCEPTOR X $15.00 = METHOD OF PAYMENT: 0 CASH ❑CHECK Carte SUBTOTAL CI VISA 0 MASTERCARD PROCESSING FEE EXPIRES: TOTAL PERMIT FEE DUE: AUTHORIZED SIGNATURE: REVISED V26/05 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2 Topic Index iBtiat UiLNG DIVISION Safety Claims It knurance vrdtkpr!! WO& iiltearW g 1 Spokane all.,, WA 99206 1 Find a Law or Rule 1 1 Get a Form or Publication t Look Up a Contractor, Electrician or Plumber printer Friendly Version General/Specialty Contractor A business registered as a construction contractor with Lai to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. License Information License ALPHAPH962KM Licensee Name ALPHA PLUMBING 8: HEATING Licensee Type CONSTRUCTION CONTRACTOR UBI 602395038 Verify Wotefs_Comp Premium Status Ind. Ins. Account Id Business Type PARTNERSHIP Address 1 13615 E TRENT AVE Address 2 City SPOKANE County SPOKANE State WA Zip 99216 Phone 5095350727 Status ACTIVE Specialty 1 PLUMBING Specialty 2 UNUSED Effective Date 5/14/2004 Expiration Date 5/14/2006 Suspend Date Separation Date Parent Company Previous License Next License ALPHAPH958841 Associated License haps://fortress.wa.goy/lni/bbip/Detail.aspx?License=ALPHAPH962KVI 10/11/2005 NOTICE The ownership of a Spokane Valley Development Permit will inure to the property owner. The permit applicant, by definition, is the property owner or an authorized agent of the property owner. It is the responsibility of the applicant/permittee that the use described on the front of this permit complies with applicable codes and that required inspections are requested. Failure to request inspections as listed below and obtain the necessary approvals before progressing beyond the point where inspections are required may necessitate removal of certain parts of the construction at the applicant'stpermittee's or property owner's expense. At a minimum, the following inspections ARE REQUIRED by City Code: FOOTING - when fors and reinforcement are In place and prior to placement of concrete -all structures, including manufactured homes. NOTE: This Inspection includes review of the structure's setback from property lines. Minimum setbacks are established by City of Spokane Valley Ordinance. Curb lines and fence lines are not necessarily indicative of properly lines. The responsibility to comply with applicable setback provisions lies solely with the permittee -neither the City of Spokane Valley nor its authorized representatives assume any responsibility for the verification or location of your property lines. Please verify their location prior to locating your structure. Failure to properly locate the structure may require Its relocation at the owners/perittee's expense. FOUNDATION - when forms and reinforcement are In place and prior to placement of concrete. PLUMBING - after rough -in, before covering, and final. MECHANICAL - rough -in of piping, before covering, metal chimneys before concealment, and final. FRAMING - after all framing, bracing and blocking is in place, rough electrical, plumbing and mechanical systems are complete, and prior to concealing. FINAL - when complete and prior to occupancy and/or use. All perils require final inspection. NOTE: In addition to Inspection of the structure, this inspection Includes review of site improvements (typically depicted on the approved site plan) required by ordinance or as a condition of approval of this permit. Items such as the Installation of fire hydrants, fire department access, on-site drainage (208' swales), road Improvements, parking and landscaping are common requirements of a permit/site plan which must be completed prior to final approval of a building or issuance of a Certificate of Occupancy. MANUFACTURED HOMES - Final inspection required when complete, stairs, handrails, skirting, etc. Installed, and prior to occupancy, completed inspection record card must be available on site. PLUMBING REVERSALS FOR SEWER CONNECTIONS - prior to cover. RIGHT-OF-WAY/APPROACH - prior to placement of concrete/asphalt ar, If gravel approach, after completion. In addition to the above, any plumbing or mechanical systems or material which would be concealed by framing, drywall, concrete, etc. must be inspected prior to cover. Check with the Building department for "special inspections' in conjunction with commercial projects. FOR INSPECTIONS Please give one working day/24 hour notice. Different parts of your project may require permits and Inspections from more than one agency. Building, plumbing (includes inferior reversals for sewer) and mechanical, City of Spokane Valley Building Division 688-0054 Road cuts for utilities or driveways, City of Spokane Valley Public Works 688-0195 or State Dept of Transportation 324-6000 Remits and inspections for electrical MMA State Department M LBW Pernds and lnspxllon, for Sewer Connecllon, Spokane County Utilifes MNNm Md Industries 324.2640 41/4604 Pe nib and Inspection for onyte septic systems, Spokane Regional Fire sprinkler and alarm systems and private access road Inspections, Spokane Valley Health OislMl 324.1560 Flre Department 692-4122 Stale law RCW 19.122 requires dial odor to any excavation Me'CALL BEFORE YOU DIG' center must be notified. Call before you dig al least 2 wo Idn9 days In advance, 4569000. PERMIT EXPIRATION AND REFUNDS All permits shall expire by limitation and be declared void if a) work is not started within 180 days of obtaining a permit, or b) work is abandoned for 180 days or more after beginning work, or c) after two years from the date of permit Issuance, regardless of whether the work is finished. If a permit Is expired for time, a new permit may be obtained for half the permit fee based on the value of the remainder of the work to finish the original permit. All refund requests must be made In writing by the original permittee to the Building Official no later than 180 days after the date of fee payment. 100% refunds will be granted for any fee erroneously paid or collected. Refunds of not more than 80% of a permit fee may be authorized when no work has been done under the permit issued. Refunds of not more than 80% of a plan review fee paid may be authorized when an application is withdrawn or cancelled prior to the plan review being completed. Owner / Agent Date Staff Approval Date Look Up a Contractor, Electrician or Plumber License Detail Page 2 of 2 1 *wane Bond Bond Company Name Bond Account Number Effective Date Expiration Date , SANW Impaired Date R 05/14/2004 #1 THOMAS, MICHAEL PARTNER 05/14/2004 Until Cancelled FORNESS, LORI PARTNER 05/14/2004 05/14/2004 BUILDING DIVISION 11707 E. Sprague Avenue, Suite 106 Spokane Valley, WA 99206 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #1 TRAVELERS CAS & SURETY CO 103562376 05/13/2004 Until Cancelled KING $6,000.00 05/14/2004 Savings Information No Matching Information Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date #2 CONTINENTAL WESTERN INS CO CNP0020240 30 05/23/2003 05/23/2006 KING $1,000,000.00 06/30/2005 1 CONTINENTAL WESTERN INS CO CNP002024020 05/23/2004 05/23/2005 $250,000.00 05/14/2004 Summons / Complaints Information Summons / Complaint Cause Number Tax Warrant Id Plaintiff County Dismissal Date Complaint Date Complaint Amount Judgement Date Judgement Amount Pa' 1 #1 052226315 KELLER SUPPLY CO KING 07/15/2005 $22,935.75 $0.00 Start a New Search Punter Friendly Version Cosx+H•4F WO, AND rxpy,Tmr6 About L&I 1 Find a job at L&I 1 Information en espanol 1 Site Feedback 1 1-800-547-8367 o Washington State Dept. of Labor and Industries. Use of this site is subject to the laws of the state of Washington. Access Agreement I Privacy and security statement I Intended use/external content policy I Visit access.wa.gov Staff only link fitteS.....1 i16 https://fortress.wa.gov/lni/bbip/Detail.aspx?License=ALPHAPH962KM 10/11/2005 p:,01 ff(eice qo f <'s • is' .?\ck-IJ Address/Legal Description: Subdivision/Block/Lot: FINAL AS -BUILT INSTALLATION gyp µ4 rH Atli- Application Vi Application fk. q 9 - coo 3,9 Note: The location of the on-site sewage system represented by the drawing is not to be construed as an exact location of the system. Remarks: Signature: Date: �`- final 2 S Septic Tank Size: Drainfield: Leachbed: pg Density is based on soil type: 3 Double .Plumbing=E,Gest , I r=x(.77,,7 gals. ft. sq: ft. 12, d N c5( s 2x t o 0 24 OC. 22 C,r.Qwi It 111 1 1 1 1 to 3 G'xc s-4-; a1 Nods e. .F(9t)14 26 t�, Min. 4 ft Brace Wall Panel per R602.10.3 & R602.10.4 Min. 2 ft 8 in. Alternate Brace Wall Panel per R602.10.6 Min. 16, 18 or 20 in. APA Portal Frame Bracing Engineered Shear Wall Bracing • zz N DW E'CCTFTU ARD PRJ ATE RAGE y AVE: 1) MATERIALS APPROVED FOR ONE HOUR FIRE RESI COI S1 ROCTION ON THE GARAGE SIDE: -1_5/8" TYPE "X" GYP BOARD (HABITABLE SPACE ABOVE) 2) OPENIN EOUIPPFD STEEL D00 DOORS. 1.14 Q`. 6) TWEEN GARAGE AND RESIDENCE SHALL ITN SOLID W000 DOOR. SOLID OR HONEYCO S NOT LESS THAN 1 3/8". OR 20 MINUTE FIRE S. DCK.ING UNDER ALL COLUMNS BEAD 'c, WALLS AND SHEAR WALLS. �BLEJOINTS EMERGENCY EGRES RE IREMENTS (AIN) FROM SLEEPING ROOMS 'ARA_ TO SPAN U.N.O. 1) NET CLEAR OPENING: 5.7 SQUARE FEET 3ROVIDE DOUBLE STUDS (NOFaSI!>DIITIDN GRADE FLOOR OPENING ,MAX 44") 5.04INCHSQUAREES FEET .N'. ER ALL HIP AND GIRDER U.NA. 2) NET CLEAR OPENING HEIGHT 2 3) NET CLEAR OPENING WIDTH 20 INCHES R. . DE SHEAR CONNECTION FROM WTERIOR 4) MAX FINISHED SILL HEIGHT 44• ABOVE FLOOR M�.�:. ;wA�LS TO TRUSSESORJOISTSA80VE 5) EMERGENCY ESCAPE & RESCUE OPENING SHALL BE OPERATIONAL FROM THE INSIDE OF THE ROOM WITHOUT THE USE OF KEYS OR TOOLS ) 0 12-- "P t WHEN INTERIOR ALTERATIONS. REPAIRS OR ADDITIONS REQUIRING A PERMIT OCCUR, OR NMI ONE OR MORE SLEEPING ROOMS ARE ADDED OR CREATED* EXISTING DWELLINGS. THE DWELLING INNT SHALL eF PROVIDED WITH SMOKE ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGSSMOKE ALARMS SHALL SE INTERCON- NECTED AND HARD WIRED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL ALARMS. BEDROOMS,AREAS VAULTEDRNG CEIILIING WITH RISE OF 24" & ON EACH FLOOR) 1r` r 4k, I,PIAFETY GLASS ( 3-o y3 -e) etot kt‘, 4X "`Ox eye) 2 2 - Egress Egress windows openable 5.7 sq. ft. - 44" sill r4',.(LTca,J 40# felt for ice dam protection 0 2it(rfel ! iz.Wrdk�. R - c ti a► 1 1 "Z p144 1 est l� 1/8" GAP �/ . BETWEEN SHEATHING Ci ly VNSCTru55e Attic Accessible fe-,, ckRACcieN r - 2.k 4 T'vekttl let a C, eR r " SP.SPtt,t fs' S- Under Floor Ventilation 1 Sq Ft per every 150 Sq Ft of under floor space area. 1 ventilating opening shall be within 3 feet of each corner. Openings shall be covered with approved material. Under floor accessible by 18" x 24" Attic Ventilation 1 Sq Ft per every 300 Sq Ft of space ventilated with at least 50% in the upper portion of roof area. C,7-40 S Sia+t Minimum depth for frost protection in the City of Spokane Valley is 24 inches measured from the bottom of the footing to finish grade. Grade slope away from building a minimum 6 inches in first 10 feet. Radon Mitigation System Required If Vents Subject to Closure 6 mil Vapor Barrier Required Z2 %tdev 1t/`A Thilsisses }-t`t p Set 1 ctc,ft 141 41111114. rYtanu A • Cvus5Q-s 2.10. ib Figure 4. Recommended construction details for APA portal frame bracing design with hold-downs (For use details see Table 2 DOUBLE PORTAL FRAME?:.. :• siNct.-.po!3TAL FRAME . •• • X,11.25"MINMEADER-.. (BUILT SOLID. SAWKG.' . . • FASTEN TOPPLATETOHEADER WITH..TWO ROWS OF ,•:. i;IFIADER•RiWPRPOSIT'SHEATHING AS. SHGWN (SEE SECTION.4)TXP,•:....'":;.: ;1" ASTEN SHEATHINGT0HEAjER WITH 8D COMMON • NAILS IN‘rGRID PATT.EI3N A :SHOWN ANOil" FoktRamEs OVER 61;P.ANE .4iipcg..(IF NEEDED) SI -14. OCCUR WITHIN 24 MID -H IGHT al_ocKiNG IS • s IISEO THEN IT MUSTRE;--.. • sTiT.coN/AzawfrkupNg R.WQF16o SLNKERSAt3. 16" or 24OOUBLE 2x POST 420018 HOLD IQWN.STRAP SHEATHING IHSTALiEDJN MANUFACTURERS'INSTRUC 5/8" DIA; ANCHOR BOLT WIT EM8PMg1.1S1...?7,:r:.).t 306. APPLIED OVER . . CNCR.5Tgiegrti. 7aMIN.: • FRONT ELEVATION Form TT -073 • . •• ...• 4A TYPICAL PORTAL FRAME ,CONSTUCTIOR Zit FRAMING woe LB HOLD ()OWN ATM! NOT Tli) SCALE I 4A .SHEATHING FILLER IF NEEDED - • 16D SINKERS: ROWS tit ". 1 3/8MIN. THICKNESS STRUCTURAL PANEL 420018 HOLD DOWN STRAP : APPLIED OVER SHEATHING Page 9 of 10 1000 LB HEADER STRAP SECTION A -A SIDE ELEVATION Wall? ext4 Below Grade SIa58 on Grade Option Il. WSEC TABLE 6-2 PRESCRIPTIVE REQUIREMENTS°.1 FOR GROUP R OCCUPANCY CLIMATE ZONE 2 Glazing Areat°: % of floor 1 0% 15% V. 17% 25% aupan Only Unlimited Group R-3 Glazing U -Factor Vertical Overhead" 0.40 0.58 Door' U - Factor 0.20 Ceiling2 R-33 Vaulted Ceiling' Wall12 Above Grade R-30 R-21 int' Wall? int4 Below Grade R-21 R-12 Floors R-30 R-10 0.40 0.58 0.20 R-38 R -3D R-19+ R-58 R-21 R-12 R-30 R-10 0.37 0.58 0.58 0.20 0.20 R-38 R-38 / U=0.031 R-30 R-19+ R-58 R-30 / R-21 U=0.034 int' / U=0.054 R-21 R-15 R-12 R-12 R-30 R-30 / U=0.029 R-10 R-10 / F=0.54 Occupancy Only Unlimited Group R-1 Occupancy Only 0.35 0.32 * Reference Case 0.58 0.58 0.2D 0.20 R-38 R-38 / U=0.031 R-30 R-21 int' R-21 R-12 R-30 R-10 R-30 / R-21 U=0.034 int' / U=0.054 R-15 R-12 R-301 U=0.029 R-10 / F=0.54 0. Nominal R -values are for wood frame assemblies only or assemblies built in accordance with Section 601.1. 1. Minimum requirements for each option listed. For example, if a proposed design has a glazing ratio to the conditioned floor area of 13%, it shall comply with all of the requirements of the 15% glazing option (or higher). Proposed designs which cannot meet the specific requirements of a listed option above may calculate compliance by Chapters 4 or 5 of this Code. 2. Requirement applies to all ceilings except single rafter or joist vaulted ceilings. 3. Requirement applicable only to single rafter or joist vaulted ceilings. 4. Below grade walls shall be insulated either on the exterior to a minimum level of R-10, or on the interior to the same level as walls above grade. Exterior insulation installed on below grade walls shall be a water resistant material, manufactured for its intended use, and installed according to the manufacturer's specifications. See Section 602.2. 5. Floors over crawl spaces or exposed to ambient air conditions. 6. Required slab perimeter insulation shall be a water resistant material, manufactured for its intended use, and installed according to manufacturer's specifications. See Section 602.4. 7. Int. denotes standard framing 16 inches on center with headers insulated with a minimum of R-5 insulation- WSEC Builder's Field Guide 5th Edition COOPERATIVE EXTENSION WASHINGTON STATE UNIVERSITY ENERGY PROGRAM 1-7 Desc: REMODELGroup: R-3 Contractor: Revised: 10/11/2005 PROVIDE DIAGRAMS AND ENGINEERING LAYOUTS FOR ROOF TRUSSES, BEAMS AND FLOOR SYSTEMS PRIOR TO FRAMING INSPECTIONS CITY COPY THIS BUILDING SUBJECT TO FIELD INSPECTION CORRECTIONS REVIEWED FOR CODE COMPLIANCE SPOKANE VALLEY BUIL NG [}IVISION bj