2006, 06-29 Permit App: 06002501 RemodelProject Number: 06002501 Inv: 1
Application
THIS IS NOT A PERMIT
'Penalties will be assessed for commencing work without a permit
Date: 6/29/2006 Page 1 of 2
Project Information:
Permit Use: REMODEL Contact: FRANK SCOTT CONSTRUCTION
Address: PO BOX 541
C - S - Z: LIBERTY LAKE WA 99019
Setbacks: Front Left: Right: Rear: Phone: (509) 869-3086
Group Name:
Project Name:
Site Information:
Plat Key:
Name: MYRON EST # 1
District: F
Parcel Number: 44042.1407 Block: 3 Lot: 7
SiteAddress: 11406 E 47TH AVE Owner: Name: GROSSMAN, S & M
Address: 11406 E 47TH CRT
Location:: CSV SPOKANE VALLEY, WA 99206-94
Zoning: UR -3.5 Urban Residential 3.5
Water District: Hold: ❑
Area: .00 Acres Width: 0 Depth: 0 Right Of Way (ft): 0
Nbr of Bldgs: 0 Nbr of Dwellings: 0
Review Information:
Review
Building Plan Review
Originally Released:
Landuse/Zoning/HE Conditions
6/29/2006 By: TMELBOU
Sewer Review
Permits:
Originally Released:
6/27/2006 By: Mharnois
IN FILE
Originally Released: 6/29/2006 By: amblake
Operator: AMB Printed By: AMB Print Date: 6/29/2006
Project Number: 06002501 Inv: 1
Application
THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Date: 6/29/2006
Contractor: FRANK SCOTT CONSTRUCTION
Address: 1409 N ORMAND
LIBERTY LAKE, WA 99019
Description
1&2 FAMILY
Gro Type
R-3 VB
Building Permit
Firm:
Phone
Page 2 of 2
FRANK SCOTT CONSTRUCTION
(509) 893-0776
This Application: Total Project:
Notes Sq Ft Valuation Sq Ft Valuation
BID 0 $60,000.00 0 $60,000.00
Totals: 0 $60,000.00 0 $60,000.00
Item Description Units
SF PLNS RVW < 7999 SQ FT 1
RESIDENTIAL PERMIT FEE
WSBC SURCHARGE
Notes:
Unit Desc Fee Amount
SELECT $285.50
1 SELECT $713.75
1 SELECT $4.50
Permit Total Fees: $1,003.75
Payment Summary:
Permit Tvoe Fee Amount Invoice Amount Amount Paid Amount Owing
Building Permit $1,003.75 $1,003.75 $0.00 $1,003.75
$1,003.75 $1,003.75 $0.00 $1,003.75
Disclaimer:
Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information
contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be
complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of
the provisions of the code or of any other state or local laws or ordinances.
Signature:
Operator: AMB Printed By: AMB
Print Date: 6/29/2006
Project Number: 06002501 Inv: 1
Application
THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Date: 626/2006 Page 1 of 2
Project Information:
Permit Use: REMODEL Contact: FRANK SCOTT CONSTRUCTION
Address: PO BOX 541
C - S - Z: LIBERTY LAKE WA 99019
Setbacks: Front Left: Right: Rear: Phone: (509) 869-3086
Group Name:
Project Name:
Site Information:
Plat Key:
Name: MYRON EST # 1
District: F
Parcel Number: 44042.1407
SiteAddress: 11406 E 47TH AVE
Location:: CSV
Zoning: UR -3.5
Water District:
Block: 3 Lot: 7
Owner: Name: GROSSMAN, S & M
Address: 11406 E 47TH CRT
SPOKANE VALLEY WA 99206-94
Urban Residential 3.5
Hold: E
Area: .00 Acres Width: 0 Depth: 0 Right Of Way (ft): 0
Nbr of Bldgs: 0 Nbr of Dwellings: 0
Review Information:
Review
Building Plan Review
Landuse/Zoning/HE Conditions
Sewer Review
Permits:
COMMUNITY DEVELOPMENT
Building Permit
Contractor: FRANK SCOTT CONSTRUCTION Firm: FRANK SCOTT CONSTRUCTION
Address: 1409 N ORMAND Phone: (509) 893-0776
LIBERTY LAKE, WA 99019
Operator: AMB Printed By: AMB Print Date: 6/26/2006
*Wane
ne
.00001vValley
Community Development
Permit Center
11707 E Sprague Ave, Suite
Spokane Valley, WA 99206
(509)688-0036 FAX: (509)::8-e
www. spokanevalley. ore. com
Residential Construction
Permit Application
0
ECERWE
37 JU
ERMIT NUMBER: „?.`,
PERMIT FEE:
;Eliji
❑ ew Construction
-1,Addition/Remodel
❑ Other:
o Accessory Bldg
o Deck
SITE ADDRESS 1 i -i o L E
? C.T S?: at... vA Z\i INA , `-tg20Lo
ASSESSORS PARCEL NO: LEGAL DESCRIPTION: 7v rO' C 5.+. 1'�o S j .o T 7 B (' 3
Building owner
Name: S CZT e 'i&I 144.1 17i7-ossv'►ya4.l
Address: 1 j L oco C - Li)' C_ r
City:SUr 0,444,41 Zip: C(Cl 10 L
q `oC( Fax:
Phone: 39 - j L{ - N —
Contact Person:.
Name: A A. S`v r -r
Phone: Ct39 _7q' / Z
:Contractor . .
Name: rnAv.11V- S71-- GAA-7"R-tA.3-7
Address: \L( 9 N O-Ron,tyx./40
City: £I ( 72j1-1 &.41/-->✓ Zip: `7�1�,
Phone: 43913 -c-n Lp Fax:
Lic No:1f1-2041,f C- i 3Q 0 Exp. Date: p aLa /2a= e6
City Business Lic No:
Describe the scope of work in detail: Cost of Project:
t2ht
t' -,'?A.�►�E nx�I tT TLr o�Z t� 3 P
t�'1N�Sr4 Y ^\
Z/!Q, /..�}J C1.c An
:n/C/.! ItfaV
**************The following MUST be complete: (write N/A if not applicable)**********************
HEIGHT TO PEAK:
N
DIMENSIONS:
# OF STORIES:
TOTAL HABITABLE SPACE:
MAIN FLOOR TO SQ.
FTG:
2"" FLOOR SQ. FTG:
UNFIN BASEMENT SQ. FTG:
IMPERVIOUS SURFACE
AREA: -
FINISHED BASEM NT
SQ. FTG: ___
GARAGE SQ. FTG:
- -
DECK/COV. PATIO SQ. FTG:
30% SLOPES ON
_
_-- ------
-•-P-ROPERIX:-
# OF BEDROOMS:
CONSTRUCTION TYPE' .
HEAT - SOURCE:
SEWER OR SEPTIC?
DISCLAIMER
The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling, the
dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The
signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done
in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of
Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or
local laws, codes or ordinances. 6) Plans or additional information may be required to be submitted, and subsequently approved before
this application can be processed.
Signature
Date
Method of Payment: (Faxed permit applications will only be accepted with major bankcard)
❑ Cash 0 Check 0 Mastercard 0 VISA
Bankcard #: Expires: VIN#:
C@(Lceo <p
❑ Other
Authorized Signature:
REVISED 8/25/2005
Spiikane
4.0.0Valley
11707 E Sprague Ave Suite 106 ♦ Spokane Valley WA 99206
509.921.1000 ♦ Fax: 509.921.1008 ♦ cityhall@spokanevalley.org
Residential Pian Submittal Minimums
❑ Completed Building & Mechanical application with: Accurate address, Parcel
Number and/or Legal Description, description of work, owner and contractor
information, signature, and date.
❑ Two sets of plans including Site Plan, elevations, floor plans, foundation plans
With details, roof plan, framing plans & details.
❑ Show the height of any proposed buildings or accessory structures.
❑ Floor plan for each floor. Dimension to scale (minimum 1/8") and label each
Room (including sq. footage of house and garage on plans) Show each
level of existing house and square footage of any additions.
❑ All braced wall panel types: show locations and details of installation, including
engineered design.
❑ Egress windows: Provide at least one window or exterior door approved for
Emergency escape or rescue from a basement and in every room for sleeping.
❑ Smoke detector locations
❑ 22° X 30" attic access location
❑ 18° X 24" crawl space access:
❑ One-hour separation detail: between house and garage
❑ Floor framing details: Joist type, size, spacing and installation details
❑ Roof framing plan and details
❑ Fumace and hot water heater location.
❑ All header locations: type, size, and connections
❑ Foundation plan
❑ Insulation information
WSEC TABLE 6-2
PRESCRIPTIVE REQUIREMENTS" FOR GROUP R OCCUPANCY
CLIMATE ZONE 2
Option
Glazing
Area10:
% of floor
Glazing U -Factor
Door9
U-
Factor
Ceiling
Vaulted
Ceiling
Wall
Above
Grade
Wall?
int
Below
Grade
Wall?
ext`
Below
Grade
Floors
Slabs
on
Grade
Vertical
Overhead „
I.
10%
0.40
0.58
0.20
R-38
R-30
R-21
int'
R-21
R-12
R-30
R-10
11.
15%
0.40
0.58
0.20
R-38
R-30
R-19+
R-21
R-12
R-30
R-10
R-56
III.
17%
0.37
0.58
0.20
R-38
R-30
R-19+
R-21
R-12
R-30
R-10
R-58
IV.
25%
0.35
0.58
0.20
R-381
R-30 /
R-21
R-15
R-12
R-30 /
R-10 /
Group R-1
U=0.031
U=0.034
int' /
U=0.029
F=0.54
Occupancy
U=0.054
Only
V.
Unlimited
Group R-3
0.35
0.58
0.20
R-38
R-30
R-21
int'
R-21
R-12
R-30
R-10
Occupancy
Only
VI.
Unlimited
0.32
0.58
0.20
R-38 /
R-30 /
R-21
R-15
R-12
R-301
R-10 /
Group R-1
U=0.031
U=0.034
int' /
U=0.029
F=0.54
Occupancy
U=0.054
Only
* Reference Case
0. Nominal R -values are for wood frame assemblies only or assemblies built in accordance with
Section 601.1.
1. Minimum requirements for each option listed. For example, if a proposed design has a glazing ratio
to the conditioned floor area of 13%, it shall comply with all of the requirements of the 15% glazing
option (or higher). Proposed designs which cannot meet the specific requirements of a listed option
above may calculate compliance by Chapters 4 or 5 of this Code.
2. Requirement applies to all ceilings except single rafter or joist vaulted ceilings.
3. Requirement applicable only to single rafter or joist vaulted ceilings.
4. Below grade walls shall be insulated either on the exterior to a minimum level of R-10, or on the
interior to the same level as walls above grade. Exterior insulation installed on below grade walls
shall be a water resistant material, manufactured for its intended use, and installed according to the
manufacturer's specifications. See Section 602.2.
5. Floors over crawl spaces or exposed to ambient air conditions.
6. Required slab perimeter insulation shall be a water resistant material, manufactured for its intended
use, and installed according to manufacturer's specifications. See Section 602.4.
7. Int. denotes standard framing 16 inches on center with headers insulated with a minimum of R-5
insulation.
WSEC Builder's Field Guide 5th Edition
COOPERATIVE EXTENSION
WASHINGTON STATE UNIVERSITY
ENERGY PROGRAM
1-7
\ \
ox 8
COMPUTER ROOM
CEILING AT III"
30 BI -FOLD
LAUNDRY )
DRYER HASHER
AN',,e'lx,1„.NAYAVA•1
ILI
CLOTH5 I
RACK
C=
NE WINDOW VERIFY
IZE IN/ OWNER
7 &AK seArl -o)C
q.
PAM! LY ROOM
CEILING AT VERIFY"
DECORATIVE PILASTER
MINIMUM 8x8 VERIFY
SIZE WITH STRUCTURE
'2 -
II 51..0 II
0
DN 2 R
P4kV
NEIN DE�M1OR P iket
C -
0f' DECKING"
---60x
A.% ..Q) 24ct
NEIN FOOTING BELOW
IN CRAWL SPACE IF NEIN
BEAM REQUIRED VERIFY
IN FIELD
61-11"
31..011
•
•
/121".4rAtrArAirdr/r AreArArrAilr
6ARAGE
OVEN
1
_L L
SKYLT ABV.
\ /
AR-FOIR, oRT/÷4 "
— — —
1
1
1— — —1
I
I I
"E4
‘411'
40' RANSE
I •
I' •
li ..N•
0 0 0- 0
0000
&\61.(--
2x4 STUD WALL
TO +41" 'TYPICAL
1—
JUJ
<0
LIVIN
ENTRY
s.„kXI NG
Mlc)---‘c3‘
\IQ 6:Pv
MORN
PROJECT
_MAINFLOOR FLAN
SCALE: 1/4" =
ViALL LEN:
•-•
• ......
ststs4s4s-1
2x6 STUD HALL 16" O.G.
2x4 STUD WALL 16" O.G.
SOFFIT ABOVE
2x4 STUD HALL ett 16" O.C. IN/ 2" AIR GAP
CONCRETE FOUNDATION
EXISTING
REMOVED
EMERGENCY EGRESS REQUIREMENTS
FROM SLEEPING ROOMS
1) NET CLEAR OPENING: 5.7 SQUARE FEET
GRADE FLOOR OPENING (MAX 44") 5.0 SQUARE FEET
2) NET CLEAR OPENING HEIGHT 24 INCHES
3) NET CLEAR OPENING WIDTH 20 INCHES
4) MAX FINISHED SILL HE161T 44" ABOVE FLOOR
5) EMERGENCY ESCAPE & RESCUE OPENING SHALL BE
OPERATIONAL FROM THE INSIDE OF THE ROOM WITHOUT
THE USE OF KEYS OR TOOLS
GYPSUM BOARD USED FOR
INTERIOR BRACED
CONSTRUCTIbN SHALL BE
FASTENED NO FURTHER
THAN 7" O.C.
WHEN INTERIOR ALTERATIONS. IMPAIRS OR ADDITMNS
REQUIRING A PERMIT NM OR MEN ME CM ME
SLEEPING ROOMS ARE ADDED�R GAMOW EESTOS
DWELLINGS, THE RIEMAN NIT SHALL at PAWNED
WITH SMOKE ALARMS LOCATED AS RIMMED FOR PEW
DWELLINGS.
SMOKE ALARMS: SHALL. BE INTERCON-
NECTED AND HARD WIRED IN SUCH A
MANNER THAT THE ACTIVATION OF ONE
ALARM WILL ACTIVATE ALL ALARMS.
(BEDROOMS, AREAS APPROACHING
BEDROOMS, VAULTED CEILING
WITH RISE OF 24" & ON EACH FLOOR)
EXHAUST FANS
IOOCFM kitchen
50 CFM bathrooms
&laundry 17EWEIED
To -AT ER..0:
UJ
tfl
ID
9
uJ
DA
,LL
0
w
7
EY.
0z
--1—j
11-
20S-255-533'1
PROVIDE DIAGRAMS AND
ENGINEERING LAYOUTS FOR
H00" _IRUSScS, BEAMS AND
FL, 1C -f SYS 1 EMS PRIOR TO FRAMING
INSPECTIONS
THIS BUILDING SUBJECT
SrPOKAn 'AC.LG , iU'F YaJH� @P3N