2007, 07-25 Permit App: 07002880 RemodelProject Number: 07002880 Inv: 1
•
Application
THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Date: 7/25/2007 Page 1 of 2
Project Information:
Petmit Use: KITCHEN RMDL Contact: THOMAS, RONALD
Address: 11617 E 47TH AVE
C - S - Z: SPOKANE VALLEY, WA 99223
Setbacks: Front Left: Right: Rear: Phone: (000) 000-0000
Group Name:
Site Information: Project Name:
Plat Key: 001744 Name: MYRON EST # 7 District: Sout
Parcel Number: 44041.0507 Block: Lot:
SiteAddress: 11617 E 47TH AVE Owner: Name: THOMAS, RONALD
Address: 11617 E 47TH AVE
SPOKANE VALLEY, WA 99223
Location:: CSV
Zoning: 1112-3.5 Urban Residential 3.5
Water District:
Area: .00 Acres Width: 0 Depth: 0 Right Of Way (ft): 0
Nbr of Bldgs: 1 Nbr of Dwellings: 1
Review Information:
Hold: 0
Review
Building Plan Review
Permits:
Building Permit
Firm OWNER
Phone: (000) 000-0000
This Application: Total Project:
Description Grp Type Notes Sq Ft Valuation So Ft Valuation
1&2 FAMILY R-3 VB KIT RMDL a f✓ 0 $7,000.00 0 $7,000.00
Contractor: OWNER
Item Description
RESIDENTIAL PERMIT FEE
WSBC SURCHARGE
SF PLNS RVW <7999 SQ FT
Totals: 0 $7,000.00 0 $7,000.00
Units Unit Desc Fee Amount
I SELECT $139.25
1 SELECT $4.50
1 SELECT $55.70
Permit Total Fees: $199.45
Operator: JD Printed By: JD Print Date: 7/25/2007
Project Number: 07002880 Inv: I
Notes:
Application
THIS IS NOT A PERMIT
Penalties will be assessed for commencing work without a permit
Date: 7/25/2007 Page 2 of 2
Payment Summary: IIIIIINSINSIOWIIWai
Permit Tyne Fee Amount Invoice Amount Amount Paid Amount Owine
Building Permit $199.45 $199.45 $0.00 $199.45
$199.45 $199.45 $0.00 $199.45
Disclaimer:
Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information
contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be
complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of
the provisions of the code or of any other state or local laws or ordinances.
Signature:
Operator: JD Printed By: ID Print Date: 7/25/2007
Permit Center
Scm of 11703 E Sprague Ave, Suite B-3
po11ane . Spokane Valley, WA 99206
�Y�Valle rt�°9?g�°° (j9)ti$8R0037
-��ww:spdk'a�bva e r
Community Development it n
Residential Construc%n7 5 2007
Permit Application
PERMIT NUMBER: 2(./Y0
PERMIT FEE:
n New Construction n Accessory Bldg
Addition/Remodel n Deck
n Other:
SITE ADDRESS: / / (D 17 E. 47 T/t AVE
ASSESSORS PARCEL NO: 440.'110507 LEGAL DESCRIPTION: MY I?0N ESTR TES ND '71:1B1
Building Owner:
Name: RON 77-04/11 15
Address: //a) /7 E 47771 AVE
City: SPPKH'NE V LLEYstate: wR• Zip:9924�
Phone: 65,3_/33 7 Fax: .1
Contact Person
Name: RON 7/0MA5
Phone: 8 g3 - /377
Describe the scope of work in detail:
Contractor:
DIMENSIONS:
Name: OWNER - ,L3U/LOCi2
TOTAL HABITABLE SPACE:
Address:
2Nu FLOOR SQ. FTG:
City: State:
Zip:
Phone: Fax:
GARAGE SQ. FTG:
Contractor Lic No: Exp Date:
30% SLOPES ON
PROPERTY:
City Business Lic. No:
CONSTRUCTION TYPE:
Cost of Project: $ PRDX.--7,000
TC HEN REMODEL,, 2EL O& TC SINK PL fig 1/116 ADD 4 #1416ED D6OR
ENLIM E W//1/D0W NEW GP/3lNET0 FDD PLUMB/NG FDR WR5O t
Proposed Use:,
**************The following MUST be complete: (write N/A if not applicable)**********************
HEIGHT TO PEAK:
DIMENSIONS:
# OF STORIES:
TOTAL HABITABLE SPACE:
MAIN FLOOR TO SQ.
FTG:
2Nu FLOOR SQ. FTG:
UNFIN BASEMENT SQ. FTG:
IMPERVIOUS SURFACE
AREA:
FINISHED BASEMENT
SQ. FTG:
GARAGE SQ. FTG:
ECK/COV. PATIO SQ. FTG:
30% SLOPES ON
PROPERTY:
# OF BEDROOMS:
CONSTRUCTION TYPE:
HEAT SOURCE:
SEWER OR SEPTIC?
The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling, the
dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The
signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done
in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of
Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or
local laws, codes or ordinances. 6) Plans or addit_io_ nnformation may be required to be submitted, and subsequently approved before
this application can be`prcees+ged. ~'
SIGNATURE:
Method of Payment:
0 Cash
Bankcard #:
Authorized Signature:
REVISED 2/15/07
0 Check
❑ Mastercard
Expires:
DATE: tJU 7 -2°2
❑ VISA
VIN#:
Sj%1s e
FValleye
11703 E Sprague Ave Suite B-3 • Spokane Valley WA 99206
509.688.0036 ♦ Fax: 509.688.0037 ♦ cityhall@spokanevalley.org
1
Residential Plan Submittal•Minimums
❑ Completed Building & Mechanical application with: Accurate address, Parcel
Number and/or Legal Description, description of work, owner and contractor
information, signature, and date.
❑ Two sets of plans including Site Plan, elevations, floor plans, foundation plans
With details, roof plan, framing plans & details.
❑ Show the height of any proposed buildings or accessory structures.
❑ Floor plan for each floor: Dimension to scale (minimum 1/8") and label each
Room (including sq. footage of house and garage on plans) Show each
level of existing house and square footage of any additions.
❑ All braced wall panel types: show locations and details of installation, including
engineered design.
❑ Egress windows; Provide at least one window or exterior door approved for
Emergency escape of resclielfrom a basement'and in every room for sleeping.
❑ Smoke detector locations,
❑ 22" X 30" attic access location
❑ 18" X 24" crawl space access:
❑ One-hour separation detail: between house and garage
❑ Floor framing details: Joist type, size, spacing and installation details
❑ Roof framing plan and details
❑ Furnace and hot water heater location.
❑ All header locations: type, size, and connections
❑ Foundation plan
❑ Insulation information
go'
5
PE5IDEhICr.:
r
K/TCNEW
RENIODE4
11 RC
...1.••••••••.,I.,•••••••••••
•
42
47Th RVE
77/641/9_5
//6 / 7 E 4 7 fit/.."
17/9/e EL 44452* .......
dt4011tOti0 ,3PORAPYIA gurilTo 143tfil
390M O 1 .0 i43i4W Rt ,RUO TIAARici avviuoiR
03TA3P3 so 0300P. RA 2MO0f4 W11413
1 "ci JjAHZ TII4U poui-foia 3HT govu LIMO
,V4A2
200'
H31
I. 313 1:1AH2 eMPAJA
1 031z41W rifiAH Go),
rItTAVirA T
;JA 3TAvli.)A
;qqA -
G3 T A V e ‘c,
T
. r
go'
,— VTCHEAI
/
• REMODEL
fiREA
PE511.22--ThiCr:
• ••••*.I114*••••=••••••••••••••••••,......•
----x---- 47TH R V E
feat,/ 77,161445
//6 / 7 E. 47 fiV5
/-9/EL 4-(252 .
TERIOR
ALTERATIONS
NINREQUIRING A PERPAIRS OR ADDITIONS
SLEEPING ROOMS ARE ADDEO OR CREATER, OR MEN D IN IEN OR
DWELLINGS, THE DWELLING UNIT SHALL OE PROVIDED
WITH SMOKE ALARMS LOCATED AS REQUIRED FOR NEW
DWELLINGS.
SMOKE ALARMS SHALL OE INTERCON-
NECTED AND HARD WIRED IN SUCH A
MANNER THAT THE ACTIVATION OF ONE
ALARM WILL ACTIVATE ALL ALARMS.
(BEDROOMS, AREAS APPROACHING
BEDROOMS, VAULTED CEILING
WITH RISE OF 24. & ON EACH FLOOR)
EXHAUST FANS
100 CFM kitchen
50 CFM bathrooms
& laundry VcN <z6
-co c>c r ot-taN—
- 71/1
I V" I
NES/
61NK
/--- X 11 C T/A/ !VI_ /
2X4 WILL5
/Go Ci3A)/"6:RS-
r / SLID/W6 PI9TIO 1:00k.
ROD H/N01-7.0 ,019/1,k' IWD 3/PE
Witv /A/ 511MF Off.NIN
IfDP PiDINEPAit:
FOk WPM& -1 DRY ER
P9NTRY
MUD ROOM
26 5'
OOF ikoss
2' EVE OVE041114&
•
if
I- ADD Door
ENLA k761.- 4,7 W/AWOW TZ; 1,7
11/ 77-1 'VFW(7;PiE 94.44iki7.17 hERDEe.
Kr(//EN
TOP FL k"
TOYE
I'/
L / //A/16,
L
/
7 kV...CS
Ki TC'EN PE D
,eu/V THOMPS
7 If. 47 77/ /9 VE- I/11Z
PI1A70:--2 It 4 z.i6 410 1_3()7
BOISE" Single 3-1/8" x 7-1/2" BOISE GLULAMTM 24F-V4/DF Floor Beam1FB01
• BC CALCe 9.5 Design Report - US 1 span I No cantilevers 10/12 slope Friday July 06, 2007 15:41
Build 91
Job Name:
Address:
City, State, Zip: ,
Customer:
Code reports: ICBG 5745, LA • 01365
File Name: BC CALC Project
Description: FB01
Specifier:
Designer: Mike Hammer
Company: Lumbermens' Building Center
Misc:
If ', r r '"
BO, 3-1/2"
DL 972 lbs
SL 1680 lbs
07-00-00
Total Horizontal Product Length = 07-00-00
-1' C
V Y -r • .
81, 3-1/2'
DL 972 lbs
SL 16801bs
Load Summary
Tag Description
2
Controls Sum
Pos. Moment
End Shear
Total Load Dell.
Live Load Defl.
Max Defl.
Span / Depth
Load Type
Unf. Area (psf)
Vane_
53 ift-Ib4 1►.
957 lbs
L/497 (C .158")
L/785 (C.1")
0.158"
10.5
Bearing Supports Dim. (L x WJ
BO Post 3-1/2" x 3-1/8"
B1 Post 3-1/2" x 3-1/8"
% ?knowable
160.1%
41.1%
48.3%
45.8%
31.6%
n/a
Value
2652 lbs
2652 lbs
Ref. Start End
Left 00-00-00 07-00-00
Duration
115%
115%
% Allow
Support
n/a
n/a
Load
Case
3
3
3
3
3
0
% Allow
Member
37.3%
37.3%
Live Dead Snow Wind
100'/0 90% 115% 133%
17 30
Span Location
1 - Internal
1 - Left
1
1
Material
Unspecified
Unspecified
Cautions
Column at Bearing BO analyzed for bearing only, column analysis has not been performed.
Column at Bearing B1 analyzed for bearing only, column analysis has not been performed.
Notes
Design meets Code minimum (L/240) Total load deflection criteria.
Design meets Code minimum (L/360) Live load deflection criteria.
Design meets arbitrary (0.5") Maximum load deflection criteria.
h'EI2D ,r...P 2. Pf S
Page 1 of 1
Roof Live
125'/. Trlb.
16-00-0C
Disclosure
Completeness and accuracy of input must
be verified by anyone who would rely on
output as evidence of suitability for
particular application. Output here based
on building code -accepted design
properties and analysis methods
Installation of BOISE engineered wood
products must be in accordance with
current Installation Guide and applicable
building codes. To obtain Installation Guide
or ask questions, please call
(888)234-0056 before installation.
BC CALC®, BC FRAMER®, AJST",
ALLJOIST®. BC RIM BOARD'", BCI® ,
BOISE GLULAMTM, SIMPLE FRAMING
SYSTEM® , VERSA -LAM®, VERSA -RIM
PLUS®, VERSA -RIM®,
VERSA -STRAND®. VERSA -STUD® are
trademarks of Boise Wood Products,
L.L.C.
PROVIDE DIAGRAMS AND
ENGINEERING LAYOUTS FOR
ROOF TRUSSES, BEAMS AND
FLOOR SYSTEMS PRIOR TO FRAMING
INSPECTIONS
CITY COPY
THIS BUILDING SUBJECT
TO FIELD INSPECTION CORRECTIONS
REVIEWED FOR CODE COMPLIANCE
SPOKANE VALLEY BUIL ING DI SION
s__ Z(o C7%-