Loading...
1993, 12-10 Permit: 93011724 ResidenceSPOKANE COUNTY DEPARTMENT OF BUILDINGS WEST 1026 BROADWAY • SPOKANE, WA 99260-0050 (509) 456-3675 SITE INFORMATION PROJECT INFORMATION SITE ADDRESS: 14204 E 30TH CT VERADALE WA 99037 PARCEL NUMBER: 45263.1032 SUBDIVISION: EVERGREEN POINT 7TH ADD LOT: 11 BLOCK: 20 ZONE: UR -3.5 INSPECTOR: REED OCKEY WATER DIST: VERA OWNER: W R S & ASSOCIATES INC PHONE: 509 922 782 ADDRESS: P 0 BOX 14084 SPOKANE WA 99214 PROJECT NUMBER: 93011724 ISSUE DATE: 12/10/93 PERMIT USE: RESIDENCE/ATTACHED GARAGE - NATURAL GAS APPLICANT: PHONE: ADDRESS: W R S & ASSOCIATES I 509 922 782 000000 P 0 BOX 14084 SPOKANE WA 99214 CONTACT: CAL SMITH PHONE: 509 922 0782 SETBACKS -> FRONT: 30 LEFT: 7 RIGHT: 30 REAR: 57 LENDER NAME: PHONE: ADDRESS: PERMIT(S) BUILDING PERMIT CONTRACTOR W R S & ASSOCIATES LICENSE #: WRSAS**245MG NEW BUILDING DIM.= 53 X 48 2 STORIES SO FT = 2544 BASEMENT U R-3 DECK R-3 GARAGE M-1 RESIDENCE R-3 2ND FLOOR R-3 TOTAL VALUE: RADON MONITOR SALES TAX VN 1200 VN 280 VN 803 VN 1220 VN 1100 $118,924.00 RESIDENTIAL VALUATION STATE SURCHARGE RESIDENTIAL SURCHARGE TOTAL PERMIT FEE 706.00 4.50 127.08 $851.16 MECHANICAL PERMIT CONTRACTOR ALLIED HEATING INC LICENSE #: ALLIEI*200D4 GAS APPLIANCE<=100,000B GAS LOG OR GAS INSERT GAS WATER HEATER GAS PIPING DUCT SYSTEMS VENTILATING FANS HEAT PUMP OR A/C 0-5 TO 3 1 5 1 TOTAL PERMIT FEE $107.00 PLUMBING PERMIT CONTRACTOR ACTION CONSTRUCTION CO LICENSE #: ACTIOCC094D5 TOILETS/BIDETS TUBS SHOWERS SINKS DISH WASHERS CLOTHES WASHER GARBAGE DISPOSAL FLOOR DRAINS WATER USING DEVICES 3 2 7 TOTAL PERMIT FEE $108.00 PAYMENT SUMMARY PAYMENT DATE 12/10/93 TOTAL FEES $1,066.16 ISSUED PERMIT RECEIPT# 00013918 AMOUNT PAID $1,066.16 PAYMENT AMOUNT $1,066.16 AMOUNT OWING BY: BURRIS, ROBIN $.00 NoTEs 1711 ri'mr L_:3 1 -"L O It is the responsibility of the permittee, not Spokane County, to see toitthat the use described on the front of this permit complies with applicable codes and requirements and that required inspedlons are requested. Failure to request required Inspections and obtain the necessary approvals prior to progressing beyond the paint where inspections are required may necessitate removal of certain pans of the construction at the owner's/permittee's expense. At a minimum, the following inspections ARE REQUIRED by County Code. 1. FOOTING - when forms and reinforcement are In place and prior to placement of concrete. NOTE: This Inspection Includes review of the structure's setbacks from property lines. Minimum setbacks are established by County zoning regulations. Typically, side and rear yard setbacks are measured from property lines, while setbacks for yards abutting streets are measured from the property line or the center line of the roadway right-of-way, whichever provides the greater setback from the center line of the roadway right-of-way. Curb lines and fence lines are not necessarily Indicative of property lines. In some residential areas, the County can own as much as 20 feet of right-of-way between your property and the actual improved street/curb. The responsibility to comply with applicable setback provisions lies solely with the permittee—neither Spokane County not Its authorized representatives assume any responsibility for the verification or location of your properly lines. Please verify their location prior to locating your structure. Failure to properly locate the structure may require its relocation at the owner's/permittee's expense. 2. FOUNDATION - when forms and reinforcement are in place and prior to placement of concrete. (Blocking for a manufactured home is required to be inspected prior to the installation of skirting.) 3. FRAMING - after all framing, bracing and blocking Is In place, and prior to concealing. 4. INSULATION - prior to the Installation of drywall. 5. PLUMBING - after rough -in, before covering, and final. 6. MECHANICAL - rough -in of piping, before covering, metal chimneys before concealment, and final. 7. FINAL - when complete and prior to occupancy and/or use. Please provide 24 hours notice. NOTE: In addition to inspection of the structure, this inspection includes review of site improvements (typically depicted on the approved site plan) required by ordinance or as a condition of approval of this permit. Items such as the installation of fire hydrants, fire department access, on-site drainage ("208 swales"), road Improvements, parking, and landscaping are common requirements of a permit/site plan which must be completed prior to final approval of a building or issuance of a Certificate of Occupancy. In addition to the above any plumbing or mechanical systems or materials which would be concealed by framing, drywall, concrete, etc., must be Inspected prior to cover. Check with the department for "special Inspections" in conjunction with commercial projects. CALL 456-3675 FOR INSPECTIONS. TO INSURE PROMPT SERVICE, PLEASE GIVE 24 HOUR NOTICE. YOUR INSPECTOR IS UNDER CERTAIN CIRCUMSTANCES, PARTS OF YOUR PROJECT MAY REQUIRE INSPECTIONS FROM OTHER AGENCIES: • Road cuts for utilities or drives, County Engineers Office 456-3600 or State Department of Transportation 456.3000 • On-site waste disposal system, Spokane County Health District 324-1560 • Construction in a flood plain, County Engineer's Office 456-3600 • Sewer connection, County Utilities Department 456-3604 or City Public Works Department 625-6300 • Electrical wiring, State Department of Labor and Industries 324-2640 EXPIRATION Unless otherwise noted, this permit will be considered null and void by limitation of the work authorized by the permit If not commenced or is stopped for a period of 180 days, unless a written request for an extension of the permit is received and approved by the Building Official prior to expiration. At a minimum an inspection should be requested at least once every 180 days to assure the validity of the permit. A permit may be renewed within one year of the date of expiration for one-half the original fee, subject to certain limitations—please call us if you have any questions. MISTAKES? If you think we've made an error in processing this permit or in conducting Inspections pertaining to It, or find erroneous information In the permit, please bring It to our attention Immediately by filing a written request for correction within 10 working days of discovery. All such requests should be directed to the Department of Buildings at the address found on the face of this permit. i..\ I certify that I have examined this permit/application, state that the Information contained in it and submitted by me or my agent to compile said permit/application is true and correct, and tthorize Spokane County to proceed with processing. In addition, I have read and understand the INSPECTION REQUIREMENTS/NOTICE provisions included herein and agree to comply with same. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. I understand that the Issuance of this permit/application and any subsequent inspection approvals o enificates of e • upanc shall no be construed to give authority to violate or cancel the provisions of any state or local law regulating ••. fru• on, • arran�nf•,ry'fnce with the provisions of any state or local laws regulating construction. SIGNATURE I ,// `'/—// AT APPLICATION / AG� 2 OWNER OR AGENT • i5_ i / C/ J l SUNNYBROOK ROAD Oth COURT CURB DROP STA. 0+45 1d O 3 BOUNDARY OF LEVEL FLAT BOTTOM AREA 19.00_ 5.50' TYP. 33_50_ - 3437 IN. (TYP.) Q Lel N' 0 Z n D m POND C BOTTOM ^EL. = 2023.02 I ir;in �-SPOKAN I� I^ TYPE 5 TYPE 3w --L\ STA O+.b GRATE E , DRAIN GRATE D21v.a 30' B d. _y GARAGE_ li ,i ADDREQS• C.1420U 304' C ZONE: LI e. t ,5 ROAD WIDTHSO FRONT 30 FLANKING:afl COMMENTS: REVIEWED DY % •- 90.00' 0 rti CooRT SCALE: 1'=20' ic EYnine G i LOT 1 , BLOCK 20 EVERGREEN POINT SEVENTH ADDITION• INLAND PACIFIC EN.GINEERiwG_:.. South 25 A1lmnnntSDokune, oihIIn9tort (5Q9) SR-1410tr' . SPOKANE COUNTY DEPARTMENT OF BUILDINGS E ADDRESS 220 o PERMIT 0 o p o APPROVED FOR COVER BY 0 4V'e/F I4ad 9 3--ti7z q o RESIDENTIAL ENERGY CODE INSPECTION CHECKLIST PERIMETER INSULATION R- /0 SUB=SLAB kGRAVEL BASE o PLASTIC MEMBRANE 0 o p 0 0 • 0 0 0 0 0 pW DATE INSULATION &;CAULK WINDOWS & DOORS PER PLANS, WINDOWS & DOORS CAULKED ADVANCED FRAMING: WALLS ✓ CEILINGS_ WALL INSULATION: R- = VAULTED CEIUNG: R-70 • BATT INSTALLATION ▪ TECHNIQUES RSOLEPLATE CAULKED PLUMBING//ELECTRICAL PENETRATIONS CAULKED }SEALED DUCTWORK EXHAUST FANS/DUCTS INSTALLED RECESSED LIGHTS ,VAPOR RETARDERS: WALL ✓ CEIUNG fsr ATTIC VENT BAFFLES dr COMBUSTION AIR DUCTS INSTALLED qJ PORAWLSPACE VENTILATION FINRADON FAN CIRCUIT APPROVED FOR COVER BY I 0 op • DATE ENERGY CODE FINAL MECHANICAL SYSTEMS BATH EXHAUST KITCHEN EXHAUST AUTOMATIC WHOLE HOUSE EXHAUST AKE-UF' AIR INTAKES DUCTWORK ac EQUIPMENT INSTRUCTIONS 01 HEATING FUEL & SYSTEM TYPE: A -- RADON MONITOR ¢SERIAL NUMBER 9N791 AWEATHERSTRIPPING PLUMBING p DOORS & WINDOWS "WATER HEATER PAD pr -ATTIC & CRAWL ACCESSES sa_SHOWER FLOW gSWITCH & OUTLET COVERFIREPLACE/WOODSTOVE PLATES _, n'b. FIREPLACE DOORS 0 V�'� - FLUE DAMPER COMBUSTION AIR CRAWLSPACE GROUND COVER CRAWLSPACE VENTILATION oik BELOW -GRADE WALLS R- %7 RADON VENT & LABEL X BATT INSTALLATION INSULATION FLOOR R -3G ATTIC R _3C TECHNIQUES o FINAL APPROVAL BY R.. -N`(38" / DATE 7—,2 0 INSPCHKZDTP