1993, 12-10 Permit: 93011724 ResidenceSPOKANE COUNTY DEPARTMENT OF BUILDINGS
WEST 1026 BROADWAY • SPOKANE, WA 99260-0050
(509) 456-3675
SITE INFORMATION
PROJECT INFORMATION
SITE ADDRESS: 14204 E 30TH CT
VERADALE WA 99037
PARCEL NUMBER: 45263.1032
SUBDIVISION: EVERGREEN POINT 7TH ADD
LOT: 11 BLOCK: 20 ZONE: UR -3.5
INSPECTOR: REED OCKEY
WATER DIST: VERA
OWNER: W R S & ASSOCIATES INC
PHONE: 509 922 782
ADDRESS: P 0 BOX 14084
SPOKANE WA 99214
PROJECT NUMBER: 93011724
ISSUE DATE: 12/10/93
PERMIT USE: RESIDENCE/ATTACHED GARAGE - NATURAL GAS
APPLICANT:
PHONE:
ADDRESS:
W R S & ASSOCIATES I
509 922 782
000000 P 0 BOX 14084
SPOKANE WA 99214
CONTACT: CAL SMITH
PHONE: 509 922 0782
SETBACKS -> FRONT: 30 LEFT: 7 RIGHT: 30 REAR: 57
LENDER NAME:
PHONE:
ADDRESS:
PERMIT(S)
BUILDING PERMIT
CONTRACTOR
W R S & ASSOCIATES
LICENSE #: WRSAS**245MG
NEW BUILDING
DIM.= 53 X 48 2 STORIES
SO FT = 2544
BASEMENT U R-3
DECK R-3
GARAGE M-1
RESIDENCE R-3
2ND FLOOR R-3
TOTAL VALUE:
RADON MONITOR
SALES TAX
VN 1200
VN 280
VN 803
VN 1220
VN 1100
$118,924.00
RESIDENTIAL VALUATION
STATE SURCHARGE
RESIDENTIAL SURCHARGE
TOTAL PERMIT FEE
706.00
4.50
127.08
$851.16
MECHANICAL PERMIT
CONTRACTOR
ALLIED HEATING INC
LICENSE #: ALLIEI*200D4
GAS APPLIANCE<=100,000B
GAS LOG OR GAS INSERT
GAS WATER HEATER
GAS PIPING
DUCT SYSTEMS
VENTILATING FANS
HEAT PUMP OR A/C 0-5 TO
3
1
5
1
TOTAL PERMIT FEE $107.00
PLUMBING PERMIT
CONTRACTOR
ACTION CONSTRUCTION CO
LICENSE #: ACTIOCC094D5
TOILETS/BIDETS
TUBS
SHOWERS
SINKS
DISH WASHERS
CLOTHES WASHER
GARBAGE DISPOSAL
FLOOR DRAINS
WATER USING DEVICES
3
2
7
TOTAL PERMIT FEE $108.00
PAYMENT SUMMARY
PAYMENT DATE
12/10/93
TOTAL FEES
$1,066.16
ISSUED PERMIT
RECEIPT#
00013918
AMOUNT PAID
$1,066.16
PAYMENT AMOUNT
$1,066.16
AMOUNT OWING
BY: BURRIS, ROBIN
$.00
NoTEs
1711 ri'mr
L_:3
1
-"L
O
It is the responsibility of the permittee, not Spokane County, to see toitthat the use described on the front of this permit complies with applicable codes
and requirements and that required inspedlons are requested. Failure to request required Inspections and obtain the necessary approvals prior to
progressing beyond the paint where inspections are required may necessitate removal of certain pans of the construction at the owner's/permittee's
expense. At a minimum, the following inspections ARE REQUIRED by County Code.
1. FOOTING - when forms and reinforcement are In place and prior to placement of concrete.
NOTE: This Inspection Includes review of the structure's setbacks from property lines. Minimum setbacks are established by County zoning
regulations. Typically, side and rear yard setbacks are measured from property lines, while setbacks for yards abutting streets are measured from
the property line or the center line of the roadway right-of-way, whichever provides the greater setback from the center line of the roadway
right-of-way. Curb lines and fence lines are not necessarily Indicative of property lines. In some residential areas, the County can own as much
as 20 feet of right-of-way between your property and the actual improved street/curb. The responsibility to comply with applicable setback
provisions lies solely with the permittee—neither Spokane County not Its authorized representatives assume any responsibility for the verification
or location of your properly lines. Please verify their location prior to locating your structure. Failure to properly locate the structure may require
its relocation at the owner's/permittee's expense.
2. FOUNDATION - when forms and reinforcement are in place and prior to placement of concrete. (Blocking for a manufactured home is
required to be inspected prior to the installation of skirting.)
3. FRAMING - after all framing, bracing and blocking Is In place, and prior to concealing.
4. INSULATION - prior to the Installation of drywall.
5. PLUMBING - after rough -in, before covering, and final.
6. MECHANICAL - rough -in of
piping, before covering, metal chimneys before concealment, and final.
7. FINAL - when complete and prior to occupancy and/or use. Please provide 24 hours notice.
NOTE: In addition to inspection of the structure, this inspection includes review of site improvements (typically depicted on the approved site
plan) required by ordinance or as a condition of approval of this permit. Items such as the installation of fire hydrants, fire department access,
on-site drainage ("208 swales"), road Improvements, parking, and landscaping are common requirements of a permit/site plan which must
be completed prior to final approval of a building or issuance of a Certificate of Occupancy.
In addition to the above any plumbing or mechanical systems or materials which would be concealed by framing, drywall, concrete, etc., must be
Inspected prior to cover. Check with the department for "special Inspections" in conjunction with commercial projects.
CALL 456-3675 FOR INSPECTIONS.
TO INSURE PROMPT SERVICE, PLEASE GIVE 24 HOUR NOTICE.
YOUR INSPECTOR IS
UNDER CERTAIN CIRCUMSTANCES, PARTS OF YOUR PROJECT MAY REQUIRE INSPECTIONS FROM OTHER AGENCIES:
• Road cuts for utilities or drives, County Engineers Office
456-3600
or State Department of Transportation
456.3000
• On-site waste disposal system, Spokane County Health District
324-1560
• Construction in a flood plain, County Engineer's Office
456-3600
• Sewer connection, County Utilities Department
456-3604
or City Public Works Department
625-6300
• Electrical wiring, State Department of Labor and Industries
324-2640
EXPIRATION
Unless otherwise noted, this permit will be considered null and void by limitation of the work authorized by the permit If not commenced or is stopped
for a period of 180 days, unless a written request for an extension of the permit is received and approved by the Building Official prior to expiration.
At a minimum an inspection should be requested at least once every 180 days to assure the validity of the permit. A permit may be renewed within
one year of the date of expiration for one-half the original fee, subject to certain limitations—please call us if you have any questions.
MISTAKES?
If you think we've made an error in processing this permit or in conducting Inspections pertaining to It, or find erroneous information In the permit,
please bring It to our attention Immediately by filing a written request for correction within 10 working days of discovery. All such requests should be
directed to the Department of Buildings at the address found on the face of this permit.
i..\
I certify that I have examined this permit/application, state that the Information contained in it and submitted by me or my agent to compile said
permit/application is true and correct, and tthorize Spokane County to proceed with processing. In addition, I have read and understand the
INSPECTION REQUIREMENTS/NOTICE provisions included herein and agree to comply with same. All provisions of laws and ordinances
governing this type of work will be complied with whether specified herein or not. I understand that the Issuance of this permit/application and any
subsequent inspection approvals o enificates of e • upanc shall no be construed to give authority to violate or cancel the provisions of any
state or local law regulating ••. fru• on, • arran�nf•,ry'fnce with the provisions of any state or local
laws regulating construction.
SIGNATURE I ,// `'/—// AT
APPLICATION /
AG� 2
OWNER OR AGENT •
i5_ i / C/ J
l
SUNNYBROOK ROAD
Oth COURT
CURB DROP
STA. 0+45
1d
O
3
BOUNDARY OF LEVEL
FLAT BOTTOM AREA
19.00_
5.50' TYP.
33_50_
- 3437
IN. (TYP.)
Q
Lel N'
0
Z
n
D
m
POND C
BOTTOM ^EL. = 2023.02
I
ir;in �-SPOKAN I�
I^ TYPE 5
TYPE 3w
--L\ STA O+.b
GRATE E ,
DRAIN
GRATE
D21v.a
30' B
d. _y
GARAGE_ li
,i
ADDREQS• C.1420U 304' C
ZONE: LI e. t ,5
ROAD WIDTHSO
FRONT 30 FLANKING:afl
COMMENTS:
REVIEWED DY %
•- 90.00'
0
rti CooRT
SCALE: 1'=20'
ic
EYnine G
i
LOT 1 , BLOCK 20
EVERGREEN POINT SEVENTH ADDITION•
INLAND PACIFIC
EN.GINEERiwG_:..
South 25 A1lmnnntSDokune, oihIIn9tort
(5Q9) SR-1410tr' .
SPOKANE COUNTY DEPARTMENT OF BUILDINGS
E
ADDRESS 220
o PERMIT
0
o p
o APPROVED FOR COVER BY
0
4V'e/F I4ad
9 3--ti7z q
o RESIDENTIAL ENERGY CODE INSPECTION CHECKLIST
PERIMETER INSULATION R- /0
SUB=SLAB
kGRAVEL BASE o PLASTIC MEMBRANE
0
o p
0
0
•
0
0
0
0
0
pW
DATE
INSULATION &;CAULK
WINDOWS & DOORS PER PLANS, WINDOWS & DOORS CAULKED
ADVANCED FRAMING:
WALLS ✓
CEILINGS_
WALL INSULATION: R-
= VAULTED CEIUNG: R-70
• BATT INSTALLATION
▪ TECHNIQUES
RSOLEPLATE CAULKED
PLUMBING//ELECTRICAL
PENETRATIONS CAULKED
}SEALED DUCTWORK
EXHAUST FANS/DUCTS
INSTALLED
RECESSED LIGHTS
,VAPOR RETARDERS:
WALL ✓
CEIUNG
fsr ATTIC VENT BAFFLES
dr COMBUSTION AIR DUCTS
INSTALLED
qJ PORAWLSPACE VENTILATION
FINRADON FAN CIRCUIT
APPROVED FOR COVER BY I
0
op
•
DATE
ENERGY CODE FINAL
MECHANICAL SYSTEMS
BATH EXHAUST
KITCHEN EXHAUST
AUTOMATIC WHOLE HOUSE
EXHAUST
AKE-UF' AIR INTAKES
DUCTWORK
ac EQUIPMENT INSTRUCTIONS
01 HEATING FUEL & SYSTEM TYPE:
A --
RADON MONITOR
¢SERIAL NUMBER 9N791
AWEATHERSTRIPPING PLUMBING
p DOORS & WINDOWS "WATER HEATER PAD
pr -ATTIC & CRAWL ACCESSES sa_SHOWER FLOW
gSWITCH & OUTLET COVERFIREPLACE/WOODSTOVE
PLATES _, n'b. FIREPLACE DOORS
0 V�'� - FLUE DAMPER
COMBUSTION AIR
CRAWLSPACE GROUND COVER
CRAWLSPACE VENTILATION
oik BELOW -GRADE WALLS R- %7 RADON VENT & LABEL
X BATT INSTALLATION
INSULATION
FLOOR R -3G
ATTIC R _3C
TECHNIQUES
o FINAL APPROVAL BY R.. -N`(38" /
DATE 7—,2
0 INSPCHKZDTP