Loading...
HomeMy WebLinkAbout2006, 08-31 Permit App 06003465 Pole BldgProject Number: 06003465 Inv: I Application Date: 8/31/2006 Page 1 of 2 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Proiect Information: Permit Use: 40 X 30 POLE BUILDING Contact: BAXTER, BRAD Address: 2523 N COLEMAN RD C - S - Z: SPOKANE, WA 99212-1411 Setbacks: Front Left: Right: Rear: Phone: (509) 991-7626 Group Name: Site Information: Project Name: Plat Key: 000000 Name: Range District: H Parcel Number: 35121.9014 Block: SiteAddress: 2523 N COLEMAN RD Location:: CSV Zoning: UNKN Unknown WaterDistnct:999 UNKNOWN Area: 30 Acres Width: 0 Nbr of Bldgs: 0 Nbr of Dwellings: 0 Review Information: Review Building Plan Review Originally Released: Driveway/Approach Originally Released: Septic Sys Review PER LANCE @ SRHD Originally Released: Landuse/Zoning/HE Conditions Lot: Owner: Name: BAXTER, BRAD Address: 2523 N COLEMAN RD SPOKANE, WA 99212-1411 Hold: ❑ Depth: 0 Right Of Way (ft): 0 8/30/2006 By: TMELBOU Released By: 8/31/2006 By: amblake Released By: 8/30/2006 By: a_blake Released By: - Originally Released: 8/30/2006 By: Cdesimas Operator: AMB Printed By: AMB Print Date: 8/31/2006 Project Number: 06003465 Inv: I Application Date: 8/31/2006 Page 2 of 2 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Permits: Contractor: OWNER Description Gro Type Notes POLE BDLG U-1 VB OWNER 40X30 Building Permit Firm: OWNER Phone: (000)000-0000 This Application: Total Project: So Ft Valuation So Ft Valuation 0 $12,000.00 0 $12,000.00 Permit Total Fees: $266.06 Notes: (A)OTHE BULDING OFFICIAL IS AUTHORIZED TO REQUIRE THE PERMIT APPLICANT TO PROVIDE FEE REIMBURSEMENT TO THE CITY OF SPOKANE VALLEY FOR ANY PROFESSIONAL SERVICES REQUIRED OUTSIDE OF CITY STAFF REVIEW. (B)OSOME EXAMPLES OF POTENTIAL OUTSIDE RESOURCES INCLUDE PLAN REVIEW, CONSTRUCTION INSPECTION AND SURVEYING. All driveway approaches to be constructed per Spokane County Standards as adopted by the City of Spokane Valley. Minimum of 7.5' from each property line, 5' from crosswalks or intersection curb and minimum of 15' of separation between any two approaches. Flat portion of a residential approach to be minimum of 16' wide, maximum of 30' wide and combined approach width not to exceed 50% of total frontage. Payment Summary: Permit Type Fee Amount Invoice Amount Amount Paid Amount Owine Building Permit $266.06 $266.06 $0.00 $266.06 $266.06 $266.06 $0.00 $266.06 Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: AMB Printed By: AMB Print Date: 8/31/2006 Totals: 0 $12,000.00 0 $12,000.00 Item Description Units Unit Desc Fee Amount RESIDENTIAL PERMIT FEE I SELECT $209.25 ACCESSORY PLANS REVIEW 1 SELECT $52.31 WSBC SURCHARGE 1 SELECT $4.50 Permit Total Fees: $266.06 Notes: (A)OTHE BULDING OFFICIAL IS AUTHORIZED TO REQUIRE THE PERMIT APPLICANT TO PROVIDE FEE REIMBURSEMENT TO THE CITY OF SPOKANE VALLEY FOR ANY PROFESSIONAL SERVICES REQUIRED OUTSIDE OF CITY STAFF REVIEW. (B)OSOME EXAMPLES OF POTENTIAL OUTSIDE RESOURCES INCLUDE PLAN REVIEW, CONSTRUCTION INSPECTION AND SURVEYING. All driveway approaches to be constructed per Spokane County Standards as adopted by the City of Spokane Valley. Minimum of 7.5' from each property line, 5' from crosswalks or intersection curb and minimum of 15' of separation between any two approaches. Flat portion of a residential approach to be minimum of 16' wide, maximum of 30' wide and combined approach width not to exceed 50% of total frontage. Payment Summary: Permit Type Fee Amount Invoice Amount Amount Paid Amount Owine Building Permit $266.06 $266.06 $0.00 $266.06 $266.06 $266.06 $0.00 $266.06 Disclaimer: Submittal of this application certifies the owner (or person(s) authorized by the owner) has both examined and finds the information contained within to be true and correct, and agrees that all provisions of laws and/or regulations governing this type of work will be complied with. Subsequent issuance of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the code or of any other state or local laws or ordinances. Signature: Operator: AMB Printed By: AMB Print Date: 8/31/2006 Project Number: 06003465 Inv: I Application Date: 8/30/2006 Page 1 of 2 THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Project Information: Permit Use: 40 X 30 POLE BUILDING Setbacks: Front Left: Right: Rear: Site Information: Plat Key: 000000 Name: Range Parcel Number: 35121.9014 Block: SiteAddress: 2523 N COLEMAN RD Location:: CSV Zoning: UNKN Unknown Water District: 999 UNKNOWN Area: 30 Acres Width: 0 Nbr of Bldgs: 0 Nbr of Dwellings: 0 Review Information: Review Building Plan Review Contact: BAXTER, BRAD Address: 2523 N COLEMAN RD C - S - Z: SPOKANE, WA 99212-1411 Phone: (509) 991-7626 Group Name: Project Name: District: H Lot: Owner: Name: BAXTER, BRAD Address: 2523 N COLEMAN RD SPOKANE, WA 99212-1411 Hold: ❑ Depth: 0 Right Of Way (ft): 0 Released By Driveway/Approach Released By: Septic Sys Review Released B PuA Landuse/Zoning/HE Conditions Permits: Contractor: OWNER Released '7�ihC �/3-o/a Ce Building Permit Firm: OWNER Phone: (000)000-0000 Operator: AMB Printed By: AMB Print Date: 8/30/2006 Spokane Valley Community Development rCTM1L �mci 11707 E Sprague Ave, Suite 106 ' Spokane Valley, WA 99206 (509)688-0036 FAX: (509)688-0037 www. okanev o rt 0 �nnp PERMIT NUMBER: PERMIT FEE: Residential Construction ❑ New Construction Permit Application ❑ Addition/Remodel ❑ Other: ❑X Accessory Bldg ❑ Deck SITE ADDRESS --d-5a3 ," �le �'✓title,/I V\- (>f, 99ata ASSESSORS PARCEL NO: -320 1.170 1 y LEGAL DESCRIPTION: B`mlding Owner r ` Coniraetor TOTAL HABITABLE SPACE: "' ;-�; � 3d t, V41 { MAIN FLOOR TO SQ. 2 FLOOR SQ. FTG: Name: IMPERVIOUS SURFACE Name: v Address: a FINISHED BASEMENT Address: DECK/COV. PATIO SQ. FTG: 30% SLOPES ON City: State:Zip: 9L 1.1 City: State: Zip: Phone: Fax:Phone: SEnR R EP C? Fax: Contractor Lie No: Exp Date: ContacterSou..a> "'City Business Lie. No: Name: - Phone:gi 91IT Describe the scope of work in detail: Cost of Project: $�CCi fn1111. vAna MITCT ha rmmnlPfr- fwri&N/A if not vv HEIGHT TO PEAK DIMENSIONS: # OF STORIES: TOTAL HABITABLE SPACE: ig 3d t, V41 MAIN FLOOR TO SQ. 2 FLOOR SQ. FTG: UNFIN BASEMENT SQ. FTG: IMPERVIOUS SURFACE FTG: AREA: FINISHED BASEMENT GARAGE SQ. FTG: DECK/COV. PATIO SQ. FTG: 30% SLOPES ON SQ. FTG: PROPERTY: # OF BEDROOMS: CONSTRUCTION TYPE: HEAT SOURCE: SEnR R EP C? The permitee verifies, acknowledges and agrees by their signature that: 1) If this permit is for construction of or on a dwelling, the dwelling is/will be served by potable water. 2) Ownership of this City of Spokane Valley Permit inure to the property owner. 3) The signatory is the property owner or has permission to represent the property owner in this transaction. 4) All construction is to be done in full compliance with the City of Spokane Valley Development Code. Referenced codes are available for review at the City of Spokane Valley Permit Center. 5) This City of Spokane Valley Permit is not a permit or approval for any violation of federal, state or local laws, codes or ordinances. 6) Plans or additional information may be required to be submitted, and subsequently approved before this application process n Signature �/,//� -/ Date Method of Payment: ❑ Cash 10Check ❑ Mastercard El VISA Bankcard #: Expires: VIN#: Authorized Signature: REVISED 8252005 SPOI-YOUSne ey 11707 E Sprague Ave Suite IDG ♦ Spokane Valley WA 99206 509.921.1DDD ♦ Fa)c 509.921.1DD8 ♦ dtyhaLL@spokanevalley.org Residential Plan Submittal Minimums ❑ Completed Building & Mechanical application with: Accurate address, Parcel Number andfor Legal Description, description of work, owner and contractor information, signature, and date. ❑ Two sets of plans including Site Plan, elevations, floor plans, foundation plans With details, roof plan, framing plans & details. ❑ Show the height of any proposed buildings or accessory structures. ❑ Floor plan for each floor. Dimension to scale (minimum 1/87. and label each Room (including sq. footage of house and garage on plans) Show each level of eAsting house and square footage of any additions. ❑ All braced wall panel types: show locations and details of installation, including engineered design. . ❑ Egress windows: Provide at least one window or wderior door approved for Emergency escape or rescue from a basement and in every room for sleeping. ❑ Smoke detector locations ❑ 22" X 30" attic access location ❑ 18' X 24" crawl space access: ❑ One-hour separation detail: between house and garage ❑ Floor framing details: Joist type, see, spacing and installation details ❑ Roof framing plan and details ❑ Furnace and hot water heater location. ❑ All header locations: type, size, and connections ❑ Foundation plan 0 Insulation information 09/30/2006 10:53 5093241567 SRHD EHS resat nsi Ui FOX 30 2006 12:05 FR I TO 3241567 P.01/03 ProjectNinrb:r•. 06003465 Inv: I Application Date; 8130/2006 Page IofZ THIS IS NOT A PERMIT Penalties will be assessed for commencing work without a permit Pro i glro rm on: Pamir Vie: 40 X 30 POLE BUILDING Contact: BAXTER BRAD Addrasa: 2523 N COLEMAN RD C - S - Z: SPOKANE, WA 99212-1411 Setbacks: Front Left Right: Rear: Phone: (509) 991-7626 Group Nate: Project Name: Plat Kry: 000000 Natne: Range District: H Pa:ctlNotnber: 35121.9014.... Block: Lot: l teAddress: 25233 N COLEMAN RD Owner: Name: BAXTER, BRAD O Address: 2623 N COLEMAN RD Location:: CSV SPOKANE, WA 99212 Zoning: UNKN Unknown WaterDistriet 999 UNKNOWN Hold: (] Area: 30 Acres Width: 0 Depth: 0 Right Of Way (ft): 0 Nbr of Bldgs: 0 Nhr of Dwcllings: 0 Rsview�o,' Rgv_ e w Build ng Plan Review y Dei, a Nay/Approach - Sept it Sys Review L:tnIue/Zoning= Conditions i Re1ea}n'1 Sy � y . Permi - Cornat3or. OWNER Firm OWNER Phone: (000) 0004000 Operatcr: AMB Printed By: AMB Print Date: 8/30/2006 AUG 32 2006 12:14 5093241567 PAGE.01 ti r -r„ r- rA0,1 (r_n PURLIN CONNECTION METHODSI S S E INTERIOR FRAME WO❑D P❑ST E - S1 NOTES FOR CONNECTI❑N DETAIL SCHEDULE THIS SHEET A). PURLINS MAY BE HUNG TREATED POST OFF THE TRUSS TDP CHORD Sl TRUSS TOP CHORDS GABLE - 16d GALV, NAILS EACH GIRT FACES W/ STANDARD TRUSS DESIGN BY TRUSS MANUFACTURER SIMPSON JOIST HANGERS POSTS - 4" X 6' TYPICAL PuRAIN S2 PURLIN SUPPORT STRUT �2' X '4' X FULL FOOTING DIMENSIONS; .B + 1' 81j D 3' 0"1 OR EQUAL, Mer�oD DEPTH OF TOP CHORD PLUS PURLIN, MAXIMUM B), PURLINS MAY BE NNecTjo A N NAIL PURLINS W/0) 16d NAILS BUTTED AND NAILED S4 , S3 NAIL STRUT TO TOP CHORD W/(3) 16d JOIST W/(2) 16d NAILS S7 NAILS EACH SIDE. N 2' X 6' GIRT (FLAT) INTO EACH PURLIN, w SPANS 12' TO 60' C). PURLINS MAY BE S4 MANUFACTURED TRUSS, NOTCH POSTS LAPPED AND NAILED 1-1/2' EACH SIDE TO PROVIDE TRUSS SEAT. W/C3) 16d NAILS 10 S5 WOOD POST, SEE POST/FOOTING SCHEDULE, $S ON CONNECTION METHODSpU S8 IN S6 4 - 40d GALV, NAILS 'IN PRE - � DRIt_LED HOLES "B" AND "C", TOENAILMEryQ � iytcTjo OR 3/4'0 MACHINE BOLT BACK SIDE OF PURLIN TYPICAL GIRT CONNECTION W/(1) 16d NAIL INTo� MIN' " S7 SOLID BLOCKING AT CONNECTION POINTS, EACH TOP CHORD MEMBER S8 TYP. PURLIN, SEE FLOOR: PLAN FOR SIZE ° aliRCI S9 2' X 6' OR 2" X 8" TOP GIRT NOTES FOR FLOOR PLAN S2 ° MerHo�aAm- C - I4N 4Si 4 - 16d NAILS OR 3/4'0 M. BOLT w S9 e 0 1 M NOTES FOR DETAIL 2- KNEEBRACE S1 TRUSS TOP CHORD, DESIGN BY OTHERS S2 TRUSS BOTTOM CHORD, DESIGN BY OTHERS S3 2' X 6' DF -L #2 EACH SIDE 0 WOOD POST, SEE POST -FOOTING SCHEDULE S5 4 - 16d GALV. NAILS, EACH SIDE 1). KNEE: BRACE REQUIRED WHERE SHOWN ON POST/FOOTING SCHEDULE, BRACE NOT REQUIRED AT GABLE END TRUSSES 2). ALTERNATE KNEE BRACE/POST AND TRUSS/POST CONNECTION = USE 3/4'0 THRU BOLTS, EACH LOCATI❑N, S 5 "'3" DETAIL 2 - KNEE BRACE N.T.S. BUILDING SPECIFICATIONS: GENERAL - ALL BUILDING CONSTRUCTION SHALL CONFORM TO THE 2003 EDITION OF THE INTERNATIONAL BUILDING CODE IBC 2003), AND ALL STATE & LOCAL BUILDING CODES. THESE SPECIFICATIONS AND PLANS ARE INTENDED FOR USE IN 30 OR 40 PSF LIVE LOAD, 85 MPH WIND SPEED, EXPOSURE B AND SEISMIC DESIGN CATEGORY C. DESIGN LOADS - ROOF LL = 30 OR 40 PSF ROOF DEAD LOAD = 5 PSF* CEILING LL = 0 PSF CEILING DL = 1 PSF * ROOF DL ALLOWS FOR A MAXIMUM OF 3" THICKNESS OF FIBERGLASS INSULATION. * MAXIMUM SOIL BEARING PRESSURE = 2,000 PSF MAXIMUM SOIL_ BEARING PRESSURE IS BASED ON SAND, SILTY SAND, CLAYEY SAND, SILTY GRAVEL AND CLAYEY GRAVEL SOILS OR BETTER. LESSER SOIL CONDITIONS WILL REQUIRE REVIEW AND FOOTING SIZE ADJUSTMENT BY THE ENGINEER. CONCRETE - MINIMUM 28 DAY COMPRESSIVE STRENGTH F'c = 2,000 psi, 4 SACK MIX FOR FOOTINGS. CAST IN PLACE CONCRETE CONSTRUCTION SHALL CONFORM TO ACI 318-99. WOOD - STRUCTURAL LUMBER SHALL CONFORM TO DF -L #2 OR BETTER BY WWPA GRADING RULES. MAXIMUM MOISTURE CONTENT SHALL BE 19% BY WEIGHT. NAILING SHALL CONFORM TO TABLE 2304.9.1 FASTENING SCHEDULE & OTHER APPROPRIATE SECTIONS OF CHAPTER 23 OF THE IPC. ALL NAILS INTO PRESERVATIVELY TREATED WOOD SHALL BE HOT -DIPPED ZINC COATED GALVANIZED STEEL, SILICONE BRONZE, COPPER OR STAINLESS STEEL. CCA TREATED 'HOOD SHALL CONFORM TO THE REQUIREMENTS OF AWPA STANDARDS C-16, C-22, C-23, C-24 & C-28. POSTS FOR BUILDINGS SHALL BE AS NOTED ON THE PLANS. ALL POST MATERIALS SHALL BE HEM -FIR #2 OR BETTER,FULL DIMENSION AND GRADED BY WWPA GRADING RULES. HARDWARE SHALL BE SIMPSON OR APPROVED EQUAL. ALL BOLTS SHALL CONFORM TO ASTM A307. METAL PANELS MAY BE DELTA RIB STYLE, GALVANIZED OR PAINTED, 29 GAUGE THICKNESS, ASTM A653 STRUCTURAL QUALITY (SQ), Fy = 80.0 ksI. ROOF PANELS SHALL BE FASTENED TO PURLINS WITH PLATED, GASKETED 1. 1/2" LONG METAL TO WOOD FASTENERS. WALL PANELS SHALL BE FASTENED TO GIRTS WITH PLATED, GASKETED 1" OR LONGER METAL TO WOOD FASTENERS. PANELS SHALL BE INSTALLED AND FASTENED ACCORDING TO THE MANUFACTURER'S RECOMMENDATIONS. SOIL COMPACTION - ALL BACKFILLED SOIL BENEATH FOOTINGS SHALL BE COMPACTED WITH A VIBRATORY COMPACTOR TO 95% OF THE PROCTOR DENSITY AS DETERMINED BY ASTM A1557, METHOD D. TRUSSES SHALL BE DESIGNED BY AND BEAR THE SEAL OF AN ENGINEER REGISTERED TO PRACTICE IN THE STATE IN WHICH THE BUILDING WILL BE CONSTRUCTED. TRUSS LOADING: TOP CHORD LIVE LOAD = 30 OR 40 PSF TOP CHORD DEAD LOAD = 5 PSF BOTTOM CHORD DEAD LOAD = 1 PSF TRUSS WEB BRACING INTERIOR OR, GABLE END TRUSSES NOTES FOR TRUSS WEB BRACINGI TRUSS DIAGRAMS WILL OFTEN REQUIRE WEB MEMBER BRACING, WHICH IS SHOWN ON TRUSS DRAWINGS' pS THE METHOD OF TRUSS WEB BRACING SHOWN ABOVE REPLACES V X 4' OR 2' X 4' WEB MEMBER BRACING FOLLOW THESE INSTRUCTIONS FOR ALL WEB MEMBER BRACING TO REPLACE 'RAT -RUN' WEB 10d NAILS @ 6' DC. Od NAILS @ 6' O.C. ' X 6" 0 2' X 8' # X 4' L -BRACE L -BRACE TRUSS WEB MEMBER TRUSS WEB MEMBER THE FOLLOWING MINIMUM ROOF DIAPHRAGM REQUIREMENTS ARE NEEDEDi • ROOF STEEL, 29 GAUGE GRAND -RIB III, 36' WIDTH OR EQUIVALENT * FIELD SCREW& #10 x 1 1/2' AT 9' O,C, (NEXT TO HIGH RIB) r EAVE AND RIDGE PURLIN SCREWS] #14 xi 1/2' AT BOTH SIDES OF EACH MAJOR RIB THE FOLLOWING MINIMUM ENDWALL DIAPHRAGM REQUIRMENTS ARE NEEDED. ENDWALL STEELi 29 GAUGE GRAND -RIB III, 36' WIDTH OR EQUIVALENT. r FIELD SCREWS #10 x 1 1/2' @ 9' CI.C, (NEXT TO HIGH RIB) BASE GIRT, EIID TRUSS, AND DOOR HEADER SCREWSt #14 x 1 1/2' @ BOTH SIDES i?F EACH MAJOR R17, S E C T I O N B- B SECTION B- B DIAPHRAGM SCREWS AT INTERIOR TRUSSES AT GABLE END TRUSS END ALLG DOOR SCREWS &WGABL BASE GIRL TRUSS TOP CHORD, EA & RIDGE PURLINS ON ROOF S2 0 S4 S5 TYPICAL RUS S BOTTOM CHORD BRACING NOTES FOR TRUSS BOTTOM CHORD BRACING N.T.S. Sl GABLE END TRUSS S2 DOUBLE INTERI❑R TRUSSES S3 2' X 4' X -BRACING @ 10' 0' D.C. S4 2' X 4' BOTTOM CHORD BRACING @ 10'-0' D.C. OR, AS SPECIFIED BY TRUSS MANUFACTURER SS TOENAIL BRACES TO TRUSSES WITH 3 - 10d NAILS TYPICAL SIDE ELEVATION NOTES FOR SIDE ELEVATION N.T.S. S1 2" X 8' HEADER S2 2" X 10' HEADER FOR 10' & 12' SLIDING DOORS 7r V n" i irnnrn rnn n, n c.uw. . .-., ... ,„r... - DIAPHRAGM I ED ABOVE REWSI TYPICAL SCREW PATTERN, EXCEPT' AS STEEL SHEETiNG SCREW PATTERNS EXPiREC 1 i 90 ii% N.T.S INTERIOR FRAME WO❑D P❑ST E POST SCHEDULE THIS SHEET S3 GABLE WALL POSTS - 6' X 6' 'TYPICAL ° DOOR POSTS - 4" X 6' TYPICAL ° S7 12 FOOTING DIMENSIONS; .B + 1' 81j D 3' 0"1 4 MAXIMUM POST SPACING 12' 0' S1 PURLINS @ 24' O.C., BEARING OR S4 , o SIS JOIST HANGERS (TYPICAL) w SPANS 12' TO 60' $S OH ZWq CL w ` cu >- J ¢ ¢ DOUBLE TRUSSES Z z I - - - 0" -+¢ ¢ --I o 1- J ,_, 0 -J C3 -1 �J aW iYJ C:) , > • o ,- J R • n" (A Li q 1,D xJ � � xLL- N( -ru p o X � . DOUBLE OVERHEAD DOOR OPTION L- N n- N O ' d w ��� liJ t/) o d N V vi _ DOUBLE _ 1- TRUSS COLUMN OPTIONAL FRONT ELEVATION ELEVATION -m - TRUSSESDETAIL - - - - - - - 0�r CONNECTION, PURLIN SUPPORT N.T.S. (nom JF "o- z¢ A 1 1 N.T.S. _�- a 1�� 12 Sl 41 " 6" o� a Q C) i0 U d . o . 1 00 3 2 X 12" W/2" X 6" C) X.. N o)Nd N N .-� U NO NO 1.03 N LcICN v w I SINGLE TRUSS' 2 - 16d NAILS PLAN VIEW N,T.S. SEETT- DETAIL CL III �.: Sl �' i I 1 6rrr 8" OR ._ , __ 10" POST SEE 4 SINGLE SLIDING DOOR OPTION DETAIL - t s2 ,-I I I I TIO OPTIONAL N AL FRONT ELEVATION 5 S5 I 1 1 N.T.S. :D N❑TES FOR SECTI❑N A -A ^ . J O TYPICAL PURLIN SEE FLOOR , ; , 12 Si � W S2 PLAiv``FOR SIZE HERS Q TRUSS DESIGN BY ❑T 4 z A S3 2' X 6' @ 24' ❑.C., 10' BAYS vv = p W v 2'. X 6' @ 24' ❑.C., 12' BAYS DF -L #2 GIRTS FLAT @ 24' ❑. C. SCHEDULE SEE 3In NAILING PATTERN F O R .. o SCONCRETE FOOTING, SEE DETAIL ,y (4_ W S5 EXTEND POST T❑ TOP ❑F PURLIN 2 WITH n ,., P 0 T LAMINATIONS S3 W FASTENED T❑ PURLINS ROOF FASTE N - 1 1/2' LONG W❑❑DFAST TEKS. NOTE: 2 X 6" LAMINATE MUST BE A TREATED MEMBER -WALLS FASTENED TO GIRTS WITH 1 LONG � ''' AND MUST EXTEND TO THE BOTTOM OF THE FOOTING. s, c• >' W❑❑DFAST TEKS. j; LAMINATE MAY BE SPLICED ABOVE MID HEIGHT OF COLUMN S4 .' SEE FOOTING DETAIL NOTES FOR FOOTING DETAIL - Boj Sl TREATED POSTS AS SIZED PER SCHEDULE BUILDING S E CT SECTION A -' A 2 VIBRATE ❑R' ROD CONCRETE T❑ OBTAIN 3068 MAND❑❑R OPTION :° ❑PEKING FULL BEARING N.T.S. S3 UNDISTURBED S❑IL �. i S1 Sl OPTIONAL FRONT ELEVATION 12 4 j ,.V. . N.T.S. y r. 2 12 - - ~ 41 20' 0' MAXIMUM sEE DETAIL . "B" 0 FOOTING � DETAIL N.T.S. w/1� GABLE END TRUSS RU SINGLE OVERHEAD DOOR `-❑PTI❑N 8 - 16d NAILS ° SPLIT SLIDER DOOR OPTION FRONT ELEVATION ° ° OPTIONAL FRONT ELEVATION 8 - 16 NAILS N.T.F. 2" X 6" X 18" N.T.S. NOTES FOR FRONT ELEVATION BOLTING "BLOCK CORNER POS NOTES FOR OPTIONAL FRONT ELEVATIONS Si HALF TRUSS DESIGN BY OTHERS ° ° Sl HALF TRUSS DESIGN BY OTHERS SUPPORT PURLINS @ END TRUSS W/2' X 6" OR 2' X 8' STD JOIST HANGERS, S2 2' X 10' HEADER UP TO 12' 0' DOORS LOWER TRUSS FOR END OVERHANG, IF REQ'D a o 2' X 12' HEADER UP TO 20' 0' DOORS S2• ,A2" X 10' HEADER ° jj'' 2" X 12' BACKED WITH 2" X 6' UP TO 24' 0' S3 °' 2' X 6' GIRTS @ 24" O.C., 10' BAYS, DF -L #2 2' X 6' X 18" 8 1 - N NAILS S3 2' X 6" HEADER O 2" X 6' GIRTS @ 24' ❑.C., 12' BAYS, DF #2 B❑LYING 'BL❑CK S4 4' X 6' DOOR POST - 8' THRU 14' S4 2' X 8" FACIA BOARDS DETAIL 3 WALL HEIGHT W/ 2' X 6" FACER, 6' X 6" DOOR POST - 16' & 18' C� TREATED WOOD POSTS, SIZED PER SCHEDULE WALL HEIGHT W/ 2' X 8' FACER. 9,TREATED 2' X 6' BOTTOM GIRT TYP. GABLE END TRUSS C❑NNECTI❑N SS DOUBLE 2' X 6' KINGPOST OR TREATED 2' X 10' BOTTOM GIRT USE BOLTING BLOCKS gjOW ALL CORNER COLUMN G,rS _ g tt.. ........... lool-1 - .,. 0 1 M NOTES FOR DETAIL 2- KNEEBRACE S1 TRUSS TOP CHORD, DESIGN BY OTHERS S2 TRUSS BOTTOM CHORD, DESIGN BY OTHERS S3 2' X 6' DF -L #2 EACH SIDE 0 WOOD POST, SEE POST -FOOTING SCHEDULE S5 4 - 16d GALV. NAILS, EACH SIDE 1). KNEE: BRACE REQUIRED WHERE SHOWN ON POST/FOOTING SCHEDULE, BRACE NOT REQUIRED AT GABLE END TRUSSES 2). ALTERNATE KNEE BRACE/POST AND TRUSS/POST CONNECTION = USE 3/4'0 THRU BOLTS, EACH LOCATI❑N, S 5 "'3" DETAIL 2 - KNEE BRACE N.T.S. BUILDING SPECIFICATIONS: GENERAL - ALL BUILDING CONSTRUCTION SHALL CONFORM TO THE 2003 EDITION OF THE INTERNATIONAL BUILDING CODE IBC 2003), AND ALL STATE & LOCAL BUILDING CODES. THESE SPECIFICATIONS AND PLANS ARE INTENDED FOR USE IN 30 OR 40 PSF LIVE LOAD, 85 MPH WIND SPEED, EXPOSURE B AND SEISMIC DESIGN CATEGORY C. DESIGN LOADS - ROOF LL = 30 OR 40 PSF ROOF DEAD LOAD = 5 PSF* CEILING LL = 0 PSF CEILING DL = 1 PSF * ROOF DL ALLOWS FOR A MAXIMUM OF 3" THICKNESS OF FIBERGLASS INSULATION. * MAXIMUM SOIL BEARING PRESSURE = 2,000 PSF MAXIMUM SOIL_ BEARING PRESSURE IS BASED ON SAND, SILTY SAND, CLAYEY SAND, SILTY GRAVEL AND CLAYEY GRAVEL SOILS OR BETTER. LESSER SOIL CONDITIONS WILL REQUIRE REVIEW AND FOOTING SIZE ADJUSTMENT BY THE ENGINEER. CONCRETE - MINIMUM 28 DAY COMPRESSIVE STRENGTH F'c = 2,000 psi, 4 SACK MIX FOR FOOTINGS. CAST IN PLACE CONCRETE CONSTRUCTION SHALL CONFORM TO ACI 318-99. WOOD - STRUCTURAL LUMBER SHALL CONFORM TO DF -L #2 OR BETTER BY WWPA GRADING RULES. MAXIMUM MOISTURE CONTENT SHALL BE 19% BY WEIGHT. NAILING SHALL CONFORM TO TABLE 2304.9.1 FASTENING SCHEDULE & OTHER APPROPRIATE SECTIONS OF CHAPTER 23 OF THE IPC. ALL NAILS INTO PRESERVATIVELY TREATED WOOD SHALL BE HOT -DIPPED ZINC COATED GALVANIZED STEEL, SILICONE BRONZE, COPPER OR STAINLESS STEEL. CCA TREATED 'HOOD SHALL CONFORM TO THE REQUIREMENTS OF AWPA STANDARDS C-16, C-22, C-23, C-24 & C-28. POSTS FOR BUILDINGS SHALL BE AS NOTED ON THE PLANS. ALL POST MATERIALS SHALL BE HEM -FIR #2 OR BETTER,FULL DIMENSION AND GRADED BY WWPA GRADING RULES. HARDWARE SHALL BE SIMPSON OR APPROVED EQUAL. ALL BOLTS SHALL CONFORM TO ASTM A307. METAL PANELS MAY BE DELTA RIB STYLE, GALVANIZED OR PAINTED, 29 GAUGE THICKNESS, ASTM A653 STRUCTURAL QUALITY (SQ), Fy = 80.0 ksI. ROOF PANELS SHALL BE FASTENED TO PURLINS WITH PLATED, GASKETED 1. 1/2" LONG METAL TO WOOD FASTENERS. WALL PANELS SHALL BE FASTENED TO GIRTS WITH PLATED, GASKETED 1" OR LONGER METAL TO WOOD FASTENERS. PANELS SHALL BE INSTALLED AND FASTENED ACCORDING TO THE MANUFACTURER'S RECOMMENDATIONS. SOIL COMPACTION - ALL BACKFILLED SOIL BENEATH FOOTINGS SHALL BE COMPACTED WITH A VIBRATORY COMPACTOR TO 95% OF THE PROCTOR DENSITY AS DETERMINED BY ASTM A1557, METHOD D. TRUSSES SHALL BE DESIGNED BY AND BEAR THE SEAL OF AN ENGINEER REGISTERED TO PRACTICE IN THE STATE IN WHICH THE BUILDING WILL BE CONSTRUCTED. TRUSS LOADING: TOP CHORD LIVE LOAD = 30 OR 40 PSF TOP CHORD DEAD LOAD = 5 PSF BOTTOM CHORD DEAD LOAD = 1 PSF TRUSS WEB BRACING INTERIOR OR, GABLE END TRUSSES NOTES FOR TRUSS WEB BRACINGI TRUSS DIAGRAMS WILL OFTEN REQUIRE WEB MEMBER BRACING, WHICH IS SHOWN ON TRUSS DRAWINGS' pS THE METHOD OF TRUSS WEB BRACING SHOWN ABOVE REPLACES V X 4' OR 2' X 4' WEB MEMBER BRACING FOLLOW THESE INSTRUCTIONS FOR ALL WEB MEMBER BRACING TO REPLACE 'RAT -RUN' WEB 10d NAILS @ 6' DC. Od NAILS @ 6' O.C. ' X 6" 0 2' X 8' # X 4' L -BRACE L -BRACE TRUSS WEB MEMBER TRUSS WEB MEMBER THE FOLLOWING MINIMUM ROOF DIAPHRAGM REQUIREMENTS ARE NEEDEDi • ROOF STEEL, 29 GAUGE GRAND -RIB III, 36' WIDTH OR EQUIVALENT * FIELD SCREW& #10 x 1 1/2' AT 9' O,C, (NEXT TO HIGH RIB) r EAVE AND RIDGE PURLIN SCREWS] #14 xi 1/2' AT BOTH SIDES OF EACH MAJOR RIB THE FOLLOWING MINIMUM ENDWALL DIAPHRAGM REQUIRMENTS ARE NEEDED. ENDWALL STEELi 29 GAUGE GRAND -RIB III, 36' WIDTH OR EQUIVALENT. r FIELD SCREWS #10 x 1 1/2' @ 9' CI.C, (NEXT TO HIGH RIB) BASE GIRT, EIID TRUSS, AND DOOR HEADER SCREWSt #14 x 1 1/2' @ BOTH SIDES i?F EACH MAJOR R17, S E C T I O N B- B SECTION B- B DIAPHRAGM SCREWS AT INTERIOR TRUSSES AT GABLE END TRUSS END ALLG DOOR SCREWS &WGABL BASE GIRL TRUSS TOP CHORD, EA & RIDGE PURLINS ON ROOF S2 0 S4 S5 TYPICAL RUS S BOTTOM CHORD BRACING NOTES FOR TRUSS BOTTOM CHORD BRACING N.T.S. Sl GABLE END TRUSS S2 DOUBLE INTERI❑R TRUSSES S3 2' X 4' X -BRACING @ 10' 0' D.C. S4 2' X 4' BOTTOM CHORD BRACING @ 10'-0' D.C. OR, AS SPECIFIED BY TRUSS MANUFACTURER SS TOENAIL BRACES TO TRUSSES WITH 3 - 10d NAILS TYPICAL SIDE ELEVATION NOTES FOR SIDE ELEVATION N.T.S. S1 2" X 8' HEADER S2 2" X 10' HEADER FOR 10' & 12' SLIDING DOORS 7r V n" i irnnrn rnn n, n c.uw. . .-., ... ,„r... - DIAPHRAGM I ED ABOVE REWSI TYPICAL SCREW PATTERN, EXCEPT' AS STEEL SHEETiNG SCREW PATTERNS EXPiREC 1 i 90 ii% N.T.S NOTE: Y� ? I. THE NEXT LARGER SIZE POST MAY BE SUBSTITUTED FOR POSTS WITH 2 X 6 LAMINATIONS. 2. ENDWALL POSTS SHALL BE 6- X 6" ROUGH CUT HEM -FIR #2 TREATED POSTS UP TO 16'-0" WALL HEIGHT. ABOVE 16' WALL HEIGHT, ' ENDWALL POSTS SHALL BE 6" X 8" ROUGH CUT HEM -FIR gj POSTS. 3. FOOTINGS FOR ENDWALL POSTS SHALL BE A MINIMUM OF 26">� 'X 3'-0" DEEP FOR WALL'HEIGHTS TO 16'-0". 'ABOVE `16' WALL HEIGHT, FOOTINGS SHALL BE 24"0 X 3'-4" DEEP. 4. ABOVE FOOTING DESIGNS ARE FOR POST FRAME BUILDINGS WITH CONCRETE FLOORS (CONTRAINED POSTS). IF BUILDINGS WILL NOT HAVE CONCRETE `FLOORS. INCREASE EnnTlun n1AURTI70 V 9" & rnnT"•in POSWIFOOTINO SCHtbULr= 92' - 24{ PANS, 30 � I�SF ME 0 POST COLUMN FOOTING KNEE BRACE CONCRETE SPACING "H" W X D "B" DIA "T' REQUIRED VOLUME, 10'-0" 8'.0'1 6" X 6" 18113.,0" NO _0.20_ 10.-0„ _.10,-0.. 6:. X 6,. 18,. 3.m NO --- 10'-0"18" 3'-0" NO 0.20 0.20 - - - - -- - --- - - ------------ -- --- -- --- 10'-0" NO 0.24- 10'-0" -18'-0" 6" X 10" . 20" 3'-0" NO 0.24 10'-0" 20'-0" 6" X 10" ; 21" 3'-0" NO 0.27 12-0" 8'-0" 6" X 6" 26" T-0" NO _0.41_ NO 0.41 NO_ _0.41 0.41- 12-0" NO 0.41_ X. NO 0.41_ -ZD'-0" 6" X 10" W/2" X 6" -26" 3' 211 NO 0.44 POST/FOOTING SCHEDULE 30' SPANS, 30 & 40 PSF LIVE LOAD POST COLUMN FOOTING KNEE BRACE CONCRETE SPACING "H" W X D "B" DIA 'T' REQUIRED VOLUME, 10'-0" 8'-0" 6" X 6" 26" 3'-0" NO _0.41 _ 10'-0" 10'-0" 6"X 6" 26" 3'-0" NO 0.41_ 10'-0" 14'-0" 6" X 6" W/2" X 6".; 26" $•-0- NO 0.41 -26;- 3;-0„--N"-0- 0.41 _10'-0" 18'4" 6" X 8" W/2" X_6" NO _ 0.41 W/2" X 6" 26" 3'-2" NO 0.44 10'-0" 24'-0" 6'-X 12" 26�� 33•� NO-- 0.45 12-0" 8'-0" 6" X 6" 28" T -O" NO 0.47 N6 6" X 6" -W/21#X 6" 28" X-0" NO 0.47 _ - - - - - - --- --N6- 12-0" - -- - - - - 12-0" _14';,0,• 6,• X 8' _28" _3,,•0'• NO 0.47 12-0" 16'-0" 6" X 8" W/2" X 6" 28" 3'-0" Kid -_0.47 --- -- -44-- ------------- ---- ---- 12-0" 6" X 10"-0" NO 0.47 '12-0.. 20'-0" 6" X_12" -28." T-.0" � 0.47 12-0" -22'-0" 6" X 12" W/2" X 6" 28" 3'2" NO 0.5 12-0" 24•,•0" 6" X 12" 28" 3'$" NO 0.66 POST/FOOTING SCHEDULE 36' SPANS, 30 & 40 PSF LIVE LOAD POST COLUMN FOOTING KNEE BRACE CONCRETE SPACING "H" W X D "B" DIA 'T' REQUIRED VOLUME, 6" X 6" 28" 3'-0" NO 0.47 10'-0" 10i3On 6" X 0�. 28,• -0.47 10'_-0" -12'_-0" 6" X 6" W/2" X 6" 26" 3'_-0" X 6" 28" T-0" NO 0.47_ _28" 3'-0" NO 0.47 10'-0" 13'-0" 6" X 8'911//2" X 6" _28" T .0" t,�; -` _ 0.47 28" ( X-0-0"_ NO _0.47 VW2" X_6" 28" 3'-0" NO 0.47 -- - 10'-0" 24 6" X 10 Wit" X 6" 28„- -3'-2"- --YES 0.60 12-0"_ 8'4" 6".X 6" 32" 3'-0" NO _0.62 611 " ,. -32��- -3, .� NO _0.62 1-0 12'-0 6 X 6 Wit X 6 32 3-0 NO 0.62 _12_-0'• 14'-0" 6" X 8-' 32" 3'-0" NO _0.62 6" X 8" W121' X 6" 32" _3'-0" NO 0.62 - --- 12-0" I V'w' 09i 10" 32" 12-0" 20'-0" 6" X 10" W/2" X 6" 32" 3'-0" NO 0.62_ 0.66_ 12-0" 24'-0" 6" X 12" W/2" X 6" 32" 3'3" NO 0.68 POSTIFOOTING SCHEDULE 40' SPANS, 30 & 40 PSF LIVE LOAD POST COLUMN FOOTING KNEE BRACE CONCRETE SPACING "H" W X D "B" DIA. 'T' REQUIRED VOLUME, 10'-0" 8'-0" 6" X 6" 30" 3'-0" NO 0.66_ 10'4" 10'-0" 6" X 6" 30" 3'-0" 1110 0.55 10'-0" 12'-0" 6" X 6" W/2" X_6" 30" X-0" NO 0.66 0.G5 10'-0" 16'-0" 6" X 8" 30" 3'-0" YES 0.66 0.66 NO -0.66_ _ NO 01-6 6" X 10" W/2" X 6"-'i0"-- -3061- 30" - 30;; 3,-2„- YES 0.68 12-0.. W-01 1 6" X 6" 3311 3.,01, NO O.AG 33" ��? -0" NO _ _ -0.66_ 3 -0" NO 0.56 12-0.. 1,4.-0.. 6,. X 8.. 33" 3.-0.: NO _ .0._66_ 6"-k 6'-"N12 X 6" 0 6S 12-0., 18.;0.. 6... X 10" 33'v 3.;011 --NO -- -0.66 _ __ NO 0.6B 12-0.. 22'-0.. arc X 12" ---- -3;; 3'-2"-- - -- 12-0" 24'-0" 6" X 12" �1f/2" X 6" 33" 3' 2" NO 6.72 POST/FOOT!NG SCHEDULE 48' TO 6c' SPANS, 30 & 40 PSF LIVE LOAD -)OST COLUMN FOOTING- KNEE B?t:CE CONCRET SPACING "H" W X D "B" 71A 'T' REQUIRED VOLUME, 10'-0" _ 8'-0'• 6'• X 6'• 34" 3',01• NO 0.70 U1 -3',0." NO 0.7_0_ 10'-0" - Z'-0" 6" X 6" W/2" X 6•• 34'1 -3'.0" NO 0.70_ 10'0" 14':d 0' X 6' -'-VV 2" X 6" -3,.0„ YES 0.70_ 10'-0" 16'-0" 6" X 8" W12" X 6" 34" T -O" NO 0.70__ - - - - _ - _ 10�-018'-0�6o� X 8" W12" X 6" _34" 3'-0" - -NO _0_.70_ _- . _.- _ _...._._ _ . ____-__ 10'-0" 22'-0" 6" X 10" W/2" -X611,-3-4!i- 3' t"' tVn - 0.70 _^_- 10'-0" G" X 12" V012" X 6" 34" 3'.0 YES 0.70 12-0" 8'-0" 6.'-'.X 6" 36"_ 3'-0"_ NO 0.79 12.0" 10'-0" 6" X 6" W/2" X 6" 36" 3 -0" Nb - p,79 12-0" 12'-0" 6,. X 6" W/2'_'_X 6" 36" _ 3'.0l' --NO - 0._79 12-0" 14'-0" 6" X 8" - _36" 3'-0" NO 0.79 12-0" 16'-0" 6"X 8" W/2" X 6" 36" 3'-0" ( NO-- - 0.79_ 12-0;. 18.;0" 6.. X 101, ------- 36"- 3'.0" - YES 0.79- 12-0" NO 0,79 _3' --- ---- -- -- --- - 12-0 24 -01611-X 12 ?".;� X 6" 36" 3'-2" NO 0.83 POST/FOOTING SCHEDULE 64' TO 60' SPANS, 30 & 40 PSF LIVE LOAD POST COLUMN FOOTING KNEE BRACE CONCRETE SPACING "H" W X D "B" DIA. 'T' REQUIRED VOLUME, 10'4" 8%0" 6" X 6" 36" T-0" NO 0.79 10'•0" 6" X 6" _36"_ 3'-0" tb - 6.79V 6" X 6" W/2" X 6"-_ 0.79 __ 81-1 36" NO 0.79_ 18.;0. Got X 10"0.79_ -- 10'-0" W/2" X 6" _36" 3'-0" YES 0.79_ 36" 3'-0" NO 0.79_ 10'4" 24'-0"- 6"X 92" - --- 36" 3, 2"- YES 0.83 - 12-011 81-011 6.1 X 6... , 0" 31-0.1 NO 0.97 .40Vn 12-0.. 12' U•� 6.. X 8.� - - --- 40„ 3;-0.._N6-_0.97 12.0" 14'-0" 6'1 X 8" Wt2_" X_6" _40•"_ 31.011 NO _0.97 3'- NO 0.87 _ --. -6.-97-- 12.0" _ - 12-0.. 18.,Or. 6r. Y_10'� -- -----4or.-- 3,,0;; -YES_ 0.9T 12-0" 20'-0" 6" X 10" W/2" X 6" 40" 3'-0" NO -0.87_ 6" k'11 W12" X 6" -40'" 3'-0" - Np- -0.87 12-0" 24'-0 " 6" X 12" W/2" X 6" 40" 3' 2" NO 1.03 NOTE: Y� ? I. THE NEXT LARGER SIZE POST MAY BE SUBSTITUTED FOR POSTS WITH 2 X 6 LAMINATIONS. 2. ENDWALL POSTS SHALL BE 6- X 6" ROUGH CUT HEM -FIR #2 TREATED POSTS UP TO 16'-0" WALL HEIGHT. ABOVE 16' WALL HEIGHT, ' ENDWALL POSTS SHALL BE 6" X 8" ROUGH CUT HEM -FIR gj POSTS. 3. FOOTINGS FOR ENDWALL POSTS SHALL BE A MINIMUM OF 26">� 'X 3'-0" DEEP FOR WALL'HEIGHTS TO 16'-0". 'ABOVE `16' WALL HEIGHT, FOOTINGS SHALL BE 24"0 X 3'-4" DEEP. 4. ABOVE FOOTING DESIGNS ARE FOR POST FRAME BUILDINGS WITH CONCRETE FLOORS (CONTRAINED POSTS). IF BUILDINGS WILL NOT HAVE CONCRETE `FLOORS. INCREASE EnnTlun n1AURTI70 V 9" & rnnT"•in POSWIFOOTINO SCHtbULr= 92' - 24{ PANS, 30 � I�SF ME 0 POST COLUMN FOOTING KNEE BRACE CONCRETE SPACING "H" W X D "B" DIA "T' REQUIRED VOLUME, 10'-0" 8'.0'1 6" X 6" 18113.,0" NO _0.20_ 10.-0„ _.10,-0.. 6:. X 6,. 18,. 3.m NO --- 10'-0"18" 3'-0" NO 0.20 0.20 - - - - -- - --- - - ------------ -- --- -- --- 10'-0" NO 0.24- 10'-0" -18'-0" 6" X 10" . 20" 3'-0" NO 0.24 10'-0" 20'-0" 6" X 10" ; 21" 3'-0" NO 0.27 12-0" 8'-0" 6" X 6" 26" T-0" NO _0.41_ NO 0.41 NO_ _0.41 0.41- 12-0" NO 0.41_ X. NO 0.41_ -ZD'-0" 6" X 10" W/2" X 6" -26" 3' 211 NO 0.44 POST/FOOTING SCHEDULE 30' SPANS, 30 & 40 PSF LIVE LOAD POST COLUMN FOOTING KNEE BRACE CONCRETE SPACING "H" W X D "B" DIA 'T' REQUIRED VOLUME, 10'-0" 8'-0" 6" X 6" 26" 3'-0" NO _0.41 _ 10'-0" 10'-0" 6"X 6" 26" 3'-0" NO 0.41_ 10'-0" 14'-0" 6" X 6" W/2" X 6".; 26" $•-0- NO 0.41 -26;- 3;-0„--N"-0- 0.41 _10'-0" 18'4" 6" X 8" W/2" X_6" NO _ 0.41 W/2" X 6" 26" 3'-2" NO 0.44 10'-0" 24'-0" 6'-X 12" 26�� 33•� NO-- 0.45 12-0" 8'-0" 6" X 6" 28" T -O" NO 0.47 N6 6" X 6" -W/21#X 6" 28" X-0" NO 0.47 _ - - - - - - --- --N6- 12-0" - -- - - - - 12-0" _14';,0,• 6,• X 8' _28" _3,,•0'• NO 0.47 12-0" 16'-0" 6" X 8" W/2" X 6" 28" 3'-0" Kid -_0.47 --- -- -44-- ------------- ---- ---- 12-0" 6" X 10"-0" NO 0.47 '12-0.. 20'-0" 6" X_12" -28." T-.0" � 0.47 12-0" -22'-0" 6" X 12" W/2" X 6" 28" 3'2" NO 0.5 12-0" 24•,•0" 6" X 12" 28" 3'$" NO 0.66 POST/FOOTING SCHEDULE 36' SPANS, 30 & 40 PSF LIVE LOAD POST COLUMN FOOTING KNEE BRACE CONCRETE SPACING "H" W X D "B" DIA 'T' REQUIRED VOLUME, 6" X 6" 28" 3'-0" NO 0.47 10'-0" 10i3On 6" X 0�. 28,• -0.47 10'_-0" -12'_-0" 6" X 6" W/2" X 6" 26" 3'_-0" X 6" 28" T-0" NO 0.47_ _28" 3'-0" NO 0.47 10'-0" 13'-0" 6" X 8'911//2" X 6" _28" T .0" t,�; -` _ 0.47 28" ( X-0-0"_ NO _0.47 VW2" X_6" 28" 3'-0" NO 0.47 -- - 10'-0" 24 6" X 10 Wit" X 6" 28„- -3'-2"- --YES 0.60 12-0"_ 8'4" 6".X 6" 32" 3'-0" NO _0.62 611 " ,. -32��- -3, .� NO _0.62 1-0 12'-0 6 X 6 Wit X 6 32 3-0 NO 0.62 _12_-0'• 14'-0" 6" X 8-' 32" 3'-0" NO _0.62 6" X 8" W121' X 6" 32" _3'-0" NO 0.62 - --- 12-0" I V'w' 09i 10" 32" 12-0" 20'-0" 6" X 10" W/2" X 6" 32" 3'-0" NO 0.62_ 0.66_ 12-0" 24'-0" 6" X 12" W/2" X 6" 32" 3'3" NO 0.68 POSTIFOOTING SCHEDULE 40' SPANS, 30 & 40 PSF LIVE LOAD POST COLUMN FOOTING KNEE BRACE CONCRETE SPACING "H" W X D "B" DIA. 'T' REQUIRED VOLUME, 10'-0" 8'-0" 6" X 6" 30" 3'-0" NO 0.66_ 10'4" 10'-0" 6" X 6" 30" 3'-0" 1110 0.55 10'-0" 12'-0" 6" X 6" W/2" X_6" 30" X-0" NO 0.66 0.G5 10'-0" 16'-0" 6" X 8" 30" 3'-0" YES 0.66 0.66 NO -0.66_ _ NO 01-6 6" X 10" W/2" X 6"-'i0"-- -3061- 30" - 30;; 3,-2„- YES 0.68 12-0.. W-01 1 6" X 6" 3311 3.,01, NO O.AG 33" ��? -0" NO _ _ -0.66_ 3 -0" NO 0.56 12-0.. 1,4.-0.. 6,. X 8.. 33" 3.-0.: NO _ .0._66_ 6"-k 6'-"N12 X 6" 0 6S 12-0., 18.;0.. 6... X 10" 33'v 3.;011 --NO -- -0.66 _ __ NO 0.6B 12-0.. 22'-0.. arc X 12" ---- -3;; 3'-2"-- - -- 12-0" 24'-0" 6" X 12" �1f/2" X 6" 33" 3' 2" NO 6.72 POST/FOOT!NG SCHEDULE 48' TO 6c' SPANS, 30 & 40 PSF LIVE LOAD -)OST COLUMN FOOTING- KNEE B?t:CE CONCRET SPACING "H" W X D "B" 71A 'T' REQUIRED VOLUME, 10'-0" _ 8'-0'• 6'• X 6'• 34" 3',01• NO 0.70 U1 -3',0." NO 0.7_0_ 10'-0" - Z'-0" 6" X 6" W/2" X 6•• 34'1 -3'.0" NO 0.70_ 10'0" 14':d 0' X 6' -'-VV 2" X 6" -3,.0„ YES 0.70_ 10'-0" 16'-0" 6" X 8" W12" X 6" 34" T -O" NO 0.70__ - - - - _ - _ 10�-018'-0�6o� X 8" W12" X 6" _34" 3'-0" - -NO _0_.70_ _- . _.- _ _...._._ _ . ____-__ 10'-0" 22'-0" 6" X 10" W/2" -X611,-3-4!i- 3' t"' tVn - 0.70 _^_- 10'-0" G" X 12" V012" X 6" 34" 3'.0 YES 0.70 12-0" 8'-0" 6.'-'.X 6" 36"_ 3'-0"_ NO 0.79 12.0" 10'-0" 6" X 6" W/2" X 6" 36" 3 -0" Nb - p,79 12-0" 12'-0" 6,. X 6" W/2'_'_X 6" 36" _ 3'.0l' --NO - 0._79 12-0" 14'-0" 6" X 8" - _36" 3'-0" NO 0.79 12-0" 16'-0" 6"X 8" W/2" X 6" 36" 3'-0" ( NO-- - 0.79_ 12-0;. 18.;0" 6.. X 101, ------- 36"- 3'.0" - YES 0.79- 12-0" NO 0,79 _3' --- ---- -- -- --- - 12-0 24 -01611-X 12 ?".;� X 6" 36" 3'-2" NO 0.83 POST/FOOTING SCHEDULE 64' TO 60' SPANS, 30 & 40 PSF LIVE LOAD POST COLUMN FOOTING KNEE BRACE CONCRETE SPACING "H" W X D "B" DIA. 'T' REQUIRED VOLUME, 10'4" 8%0" 6" X 6" 36" T-0" NO 0.79 10'•0" 6" X 6" _36"_ 3'-0" tb - 6.79V 6" X 6" W/2" X 6"-_ 0.79 __ 81-1 36" NO 0.79_ 18.;0. Got X 10"0.79_ -- 10'-0" W/2" X 6" _36" 3'-0" YES 0.79_ 36" 3'-0" NO 0.79_ 10'4" 24'-0"- 6"X 92" - --- 36" 3, 2"- YES 0.83 - 12-011 81-011 6.1 X 6... , 0" 31-0.1 NO 0.97 .40Vn 12-0.. 12' U•� 6.. X 8.� - - --- 40„ 3;-0.._N6-_0.97 12.0" 14'-0" 6'1 X 8" Wt2_" X_6" _40•"_ 31.011 NO _0.97 3'- NO 0.87 _ --. -6.-97-- 12.0" _ - 12-0.. 18.,Or. 6r. Y_10'� -- -----4or.-- 3,,0;; -YES_ 0.9T 12-0" 20'-0" 6" X 10" W/2" X 6" 40" 3'-0" NO -0.87_ 6" k'11 W12" X 6" -40'" 3'-0" - Np- -0.87 12-0" 24'-0 PROVIDE DIAGRAMS AND ENGINEERING LAYOUTS FOR ROOF TRUSSES, BEAMS AND FLOOR SYSTEMS PRIOR TO FRAMING INSPECTIONS CITY COPY THIS BUILDING SUBJECT TO -FIELD INSPECTION CORRECTIONS IigVIEWq FOR COD SPCK ANE VALLEY 3UDING g1VISION COMPLIANCE