Loading...
2006, 09-15 Permit App 06003682 Structural Details(U TREATED POST - 16d GALV. NAILS EACH GIRT (--- 2" X 6' GIRT (FLAT) TYPICAL GIRT CONNECTION NOTES FOR FLOOR PLAN D INTERIOR FRAME WOOD POSTS, SEE POST SCHEDULE THIS SHEET GABLE WALL POSTS - 6' X 6' TYPICAL DOOR POSTS - 4' X 6' TYPICAL FOOTING DIMENSIONS, B + 1' 8"j D = 3' 0' MAXIMUM POST SPACING 12' 0' �3 PURLINS @ 24' O.C., BEARING OR JOIST HANGERS (TYPICAL) 0 Z"Q JD CeJ •O 0-W .> - �J XW • 010 0_ De) 2 A W W 0 0 (U f SPANS 12' TO 60' PURLIN CONNECTION METHODS: A), PURLINS MAY BE HUNG` OFF THE TRUSS TOP CHORD FACES W/ STANDARD ` SIMPSON JOIST HANGERS OR EQUAL. B). PURLINS MAY BE BUTTED AND NAILED W/(2) 16d NAILS INTO EACH PURLIN C). PURLINS MAY BE LAPPED AND NAILED W/(3) 16dNAILS. ON CONNECTION METHODS 'B' AND "C", TOENAIL BACK SIDE OF PURLIN W/(1) 16d NAIL INTO EACH TOP CHORD MEMBER f DOUBLE TRUSSES DOUBLE TRUSSES SINGLE TRUSS ni PLAN VIEW NOTES FOR SECTION A -A si TYPICAL PURLIN, SEE FLOOR PLAN FOR SIZE S2 TRUSS DESIGN BY OTHERS 0 2' X 6' @ 24' O.C., 10' BAYS 2' X 6' @ 24' O.C., 12' BAYS DF-L #2 GIRTS FLAT @ 24' O.C. CONCRETE FOOTING, SEE SCHEDULE EXTEND POST TO TOP OF PURLIN ROOF FASTENED TO PURLINS WITH 1 1/2' LONG WOODFAST TEKS. WALLS FASTENED TO GIRTS WITH 1' LONG WOODFAST TEKS. 0 S5 N.T.S. rg 5 SEE FOOTING DETAIL igigt BUILDING SECTION A -A N.T.S. 12 ° I -1 20' 0' MAXIMUM i i i 11111111.111111. SINGLE OVERHEAD DOOR OPTION FRONT ELEVATION N.T.S. 43 NOTES FOR FRONT ELEVATION S1 HALF TRUSS DESIGN BY OTHERS SUPPORT PURLINS @ END TRUSS W/2' X 6' OR 2' X 8' STD JOIST HANGERS, LOWER TRUSS FOR END OVERHANG, IF REQ'D 2' X 10' HEADER 2' X 6' GIRTS @ 24' O.C., 10' BAYS, DF-L #2 2' X 6' GIRTS @ 24' O.C., 12' BAYS, DF-L #2 2' X 8' FACIA BOARDS TREATED WDDD POSTS, SIZED PER SCHEDULE TREATED 2' X 6' BOTTOM .GIRT OR TREATED 2' X 10" BOTTOM GIRT DETAIL 1 TRUSS COLUMN CONNECTION, PURLIN SUPPORT N.T.S. // • 16c1 NAILS 6", 8" DR 10" POST NAILING .PATTERN FOR POST LAMINATIONS NOTE: 2" 'X 6" LAMINATE MUST BE A TREATED MEMBER AND MUST EXTEND TO THE BOTTOM OF THE FOOTING. LAMINATE MAY BE SPLICED ABOVE MID HEIGHT OF COLUMN NOTES FOR FOOTING DETAIL 1S;. TREATED POSTS AS SIZED PER SCHEDULE 2 VIBRATE OR ROD CONCRETE TO OBTAIN FULL BEARING UNDISTURBED S❑IL FOOTING DETAIL GABLE END TRUSS 16d NAILS 2 " X 6" X 18" BOLTING BLOCK 2" X 6" X 18' BOLTING BLOCK DETAIL 3 TYP. GABLE END TRUSS CONNECTION USE BOLTING BLOCKS BELOW ALL CORNER COLUMN GIRTS N.T.S. 8 16d NAILS CORNER POST - 16d "NAILS PURLIN • ON t HOD 'A' 12 NOTES FOR CONNECTI❑N DETAIL 0 TRUSS TOP CHORDS TRUSS DESIGN BY TRUSS MANUFACTURER 0 PURLIN SUPPORT STRUT 2' X '4' X FULL DEPTH OF TOP CHORD PLUS PURLIN. NAIL PURLINS W/(3) 16d NAILS 0 NAIL STRUT TO TOP CHORD W/(3) 16d NAILS EACH SIDE. S4 MANUFACTURED TRUSS. NOTCH POSTS 1-1/2' EACH SIDE TO PROVIDE TRUSS SEAT. 0 WOOD POST, SEE POST/FOOTING SCHEDULE. 06 4 40d GALV. NAILS IN PRE -DRILLED HOLES OR 3/4'0 MACHINE BOLT 0 SOLID BLOCKING AT CONNECTION PINTS. S8 TYP. PURLIN, SEE FLOOR PLAN FOR SIZE 0 2" X 6' OR 2' X 8' TOP GIRT S1 4 - 16d NAILS OR 3/4'0 M, BOLT DOUBLE OVERHEAD DOOR OPTION OPTIONAL FRONT ELEVATION 12 41 N.T.S. SINGLE SLIDING DOOR OPTION OPTIONAL FRONT ELEVATION N.T.S. S3) 3068 MAND❑DR OPTION s4 OPENING OPTIONAL FRONT ELEVATION N.T.S. 12 41- SPLIT SLIDER DOOR OPTION OPTIONAL FRONT ELEVATION N.T.S. NOTES FOR OPTIONAL FRONT ELEVATIONS Si HALF TRUSS DESIGN BY OTHERS S2 2' X 10' HEADER UP TO 12' 0' DOORS 2' X 12' HEADER UP TO 20' 0' DOORS 2' X 12' BACKED WITH 2' X 6' UP TO 24' 0' 0.;3 2' X 6' HEADER S4 4' X 6' DOOR POST - 8' THRU 14' WALL HEIGHT W/ 2' X 6' FACER. 6' X 6' DOOR POST - 16' & 18' WALL HEIGHT W/ 2' X 8' FACER, S5 DOUBLE 2' X 6' KINGPOST DETAIL 2 NOTES FOR DETAIL 2- KNEEBRACE S1 TRUSS TOP CHORD, DESIGN BY OTHERS S2 TRUSS BOTTOM CHORD, DESIGN BY OTHERS S3 2' X 6' DF-L #2 EACH SIDE S4 WOOD POST, SEE POST/FOOTING SCHEDULE S5 4 - 16d GALV. NAILS, EACH SIDE 1). KNEE BRACE REQUIRED WHERE SHOWN ON POST/FOOTING SCHEDULE. BRACE NOT REQUIRED AT GABLE END TRUSSES. 2). ALTERNATE KNEE BRACE/POST AND TRUSS/POST CONNECTION = USE 3/4'0 THRU BOLTS, EACH LOCATION. KNEE BRACE N.T.S. BUILDING SPECIFICATIONS: GENERAL - ALL BUILDING CONSTRUCTION SHALL CONFORM TO THE 2003 EDITION OF THE INTERNATIONAL BUILDING CODE (IBC 2003), AND ALL STATE Sc LOCAL BUILDING CODES. THESE SPECIFICATIONS AND PLANS ARE INTENDED FOR USE IN 30 OR 40 PSF LIVE LOAD, 85 MPH WIND SPEED, EXPOSURE B AND SEISMIC DESIGN CATEGORY C. DESIGN LOADS - ROOF LL = 30 OR 40 PSF ROOF DEAD LOAD = 5 PSF* CEILING LL = 0 PSF CEILING DL = 1 PSF * ROOF DL ALLOWS FOR A MAXIMUM OF 3" THICKNESS OF FIBERGLASS INSULATION. * MAXIMUM SOIL BEARING PRESSURE = 2,000 PSF MAXIMUM SOIL BEARING PRESSURE IS BASED ON SAND, SILTY SAND, CLAYEY SAND, SILTY GRAVEL AND CLAYEY GRAVEL SOILS OR BETTER ACCORDING TO IBC TABLE 1804.2. LESSER SOIL CONDITIONS WILL REQUIRE REVIEW AND FOOTING SIZE ADJUSTMENT BY THE ENGINEER. CONCRETE - MINIMUM 28 DAY COMPRESSIVE STRENGTH F'c = 2,000 psi, 4 SACK M!X FOR FOOTINGS. CAST IN PLACE CONCRETE CONSTRUCTION SHALL CONFORM TO ACI 318-99. WOOD - STRUCTURAL LUMBER SHALL CONFORM TO DF-L #2 OR BETTER BY WWPA GRADING RULES. MAXIMUM MOISTURE CONTENT SHALL BE 19% BY WEIGHT. NAILING SHALL CONFORM TO TABLE 2304.9.1 FASTENING SCHEDULE & OTHER APPROPRIATE SECTIONS OF CHAPTER 23 OF IBC 2003. ALL NAILS INTO TREATED WOOD SHALL BE HOT -DIPPED ZINC COATED GALVANIZED STEEL, SILICONE BRONZE COPPER OR STAINLESS STEEL. CCA TREATED WOOD SHALL CONFORM TO THE REQUIREMENTS OF AWPA STANDARDS C-16, C-22, C-23, C-24 & C-28. POSTS FOR BUILDINGS SHALL BE AS NOTED ON THE PLANS. ALL POST MATERIALS SHALL BE HEM -FIR #2 OR BETTER, FULL DIMENSION AND GRADED BY WWPA GRADING RULES. HARDWARE SHALL BE SIMPSON OR APPROVED EQUAL. ALL BOLTS SHALL CONFORM TO ASTM A307. METAL PANELS MAY BE DELTA RIB STYLE, GALVANIZED OR PAINTED, 29 GAUGE THICKNESS, ASTM A653 STRUCTURAL QUALITY (SQ), Fy = 80.0 ksi. ROOF PANELS SHALL BE FASTENED TO PURLINS WITH PLATED, GASKETED 1 1/2" LONG METAL TO WOOD FASTENERS. WALL PANELS SHALL BE FASTENED TO GIRTS WITH PLATED, GASKETED 1" OR LONGER METAL TO WOOD FASTENERS. PANELS SHALL BE INSTALLED AND FASTENED ACCORDING TO THE MANUFACTURER'S RECOMMENDATIONS. SOIL COMPACTION - ALL BACKFILLED SOIL BENEATH FOOTINGS SHALL BE COMPACTED WITH A VIBRATORY COMPACTOR TO 95% OF THE PROCTOR DENSITY AS DETERMINED BY ASTM A1557, METHOD D. TRUSSES SHALL BE DESIGNED BY AND BEAR THE SEAL OF AN ENGINEER REGISTERED TO PRACTICE IN THE STATE OF WASHINGTON. TRUSS LOADING: TOP CHORD LIVE LOAD = 30 OR 40 PSF TOP CHORD DEAD LOAD = 5 PSF BOTTOM CHORD DEAD LOAD = 1 PSF NOTES F TRUSS DIAGF THE METHOD FOLLOW THE TRUSS WEB BRACING INTERIOR OR GABLE END TRUSSES DR TRUSS WEB BRACING: AMS WILL OFTEN REQUIRE WEB MEMBER BRACING; WHICH IS SHOWN ON TRUSS DRAWINGS.• pS , OF TRUSS WEB BRACING SHOWN ABOVE REPLACES 1" X °4" OR 2" X 4" WEB MEMBER BRACING SE INSTRUCTIONS FOR ALL WEB MEMBER BRACING TO REPLACE "RAT -RUN" WEB SHEATHING REQUIRMENTS THE FOLLOWING MINIMUM ROOF DIAPHRAGM REQUIREMENTS ARE NEEDED * ROOF STEEL+ 29 GAUGE GRAND -RIB III, 36' WIDTH OR EQUIVALENT * FIELD SCREW& #10 x 1 1/2' AT 9' D.C. (NEXT TO HIGH RIB) EAVE AND RIDGE PURLIN SCREWS' R14 xl 1/2' AT BOT-I SIDES OF EACH MAJOR RIB THE FOLLOWING MINIMUM ENDWALL DIAPHRAGM REQUIRMENTS ARE NEEDED ENDWALL STEEL' 29 GAUGE GRAND -RIB III, 36' WIDTH OR EQUIVALENT * FIELD SCREWS' 1110 x 1 1/2' @ 9' O.C. (NEXT TO HIGH RIB) * BASE GIRT, END TRUSS, AND DOOR HEADER SCREWS+ R14 x 1 1/2' @ BOTH SIDES OF EACH MAJOR RIB. DIAPHRAGM SCREWS DIAPHRAGM SCREWS @ ENDWALL BASE GIRT ACROSS ENDWALL DOOR HEADERS & GABLE END TRUSS TOP CHORD, EAVE & RIDGE PURLINS ON ROOF DOTED ABOSCREWS) TYPICAL SCREW PATTERN, XCEPT AS STEEL SHEETING SCREW PATTERNS N.T.S OVERHEAD DOOR ❑PENING 10d NAILS @ 6" O.C. " X 6" OR 2' X 8" L-BRACE 0d NAILS @ 6' O.C. " X 4" L-BRACE TRUSS WEB MEMBER TRUSS WEB MEMBER SECTION B-B SECTION B-B AT INTERIOR TRUSSES AT GABLE END TRUSS 1Z® TYPICAL TRUSS BOTTOM CHORD B'tACING NOTES FOR TRUSS BOTTOM CIDRD BRACING Si GABLE END TRUSS 0 DOUBLE INTERIOR TRUSS 0 2" X 4" X-BRACING @ 10' 0" O.C. 0 2" X 4" BOTTOM CHORD BRACING @ 10'-0' O.C. OR, AS SPECIFIED BY TRUSS MANUFACTURER 0 TOENAIL BRACES TO TRUSSES WITH 3 - 10d NAILS SLIDING DOOR ❑PENING TYPICAL SIDE ELEVATION NOTES FOR SIDE ELEVATION S1 2' X 8' HEADER S2 2' X 10' HEADER FOR 10' 2' X 8' HEADER FOR 8' & N.T.S. 12' SLIDING DOORS SMALLER SLIDING DOORS N.T.S. POST/FOOTING SCHEDULE 12' - 24' SPANS, 30 & 40 PSF LIVE LOAD POST COLUMN FOOTING KNEE BRACE CONCRETE SPACING "H" W X D "B" DIA. "T' REQUIRED VOLUME, YD3 10'-0" 8'-0" 6" X 6" 18" 3'-0" NO 0.20 10'-0" 10'4" 6" X 6" 18" 3'-0" NO • 0.20 10'-0" 12'-0" 6" X 6" 18" 3'-0" NO 0.20 10'-0' 14'-0 6" X 6" W/2" X 6" 18" 3'-0" NO 0.20 10'4' 16'4' 6" X 8" 20" 3'-0" NO 0.24 10'-0" 18'-0" 6" X 10" 20" 3'-0" NO 0.24 10'-0' 20'-0" 6" X 10" 21" 3'-0" NO 0.27 12-0" 8'-0' 6" X 6" 26" 3 -0" NO 0.41 12.0 10'.0 6" X6" 2 6" 3 '.0 NO 0 41 12-0 12.0 _ 6" X 6" W/2" X 6" 26" 3.0"" NO 0.41 12-0" 14'-0" 6" X 6" W/2" X 6" 26" 3'4" NO 0.41 12-0" 16'-0" 6" X 8" W/2" X 6" 26" 3 -O" NO 0.41 12-0" 18'4" 6" X 8" W/2" X 6" 26" 3'-0" NO 0.41 12'-0" 20'-0" 6" X 10" W/2" X 6" 26" 3'-2" NO 0.44 POST/FOOTING SCHEDULE 30' SPANS, 30 & 40 PSF LIVE LOAD POST COLUMN FOOTING KNEE BRACE CONCRETE SPACING "H" W X•D "B" DIA. "T' REQUIRED VOLUME, YD3 10'-0" 8'-0" 6" X 6" 26" 3'-0" NO 0.41 10'-0" 10'-0" 6" X 6" 26" 3'-0" NO 0.41 10'4" 12'4" 6" X 6" W/2" X 6" 26" 3'-0" NO 0.41 10'-0" 14'-0" 6" X 6" W/2" X 6" 26" 3'-0" NO 0.41 10'-0" 16'4" 6" X 8" 26" 3'-O" NO 0.41 10'-0" 18'-0" 6" X 8" W/2" X 6" 26" 3'4" NO 0.41 10'-0" 20'-0" 6" X 8" W2" X 6" 26" 3'-0" NO 0.41 10'-0" 22'4" 6" X 10" W/7' X 6" 26" 3'-2" NO 0.44 10'-0" 24'-0" -6"X 12" 26 3'-3" NO 0.45 12-0" 8'-O" 6" X 6" 28" 3'-0" NO 0.47 12-0"_ 10 -0' 6" X 6" 28" 3'-O" NO 0.47 12-0" 12 -0" 6" X 6" W/2" X 6" 28" • 3'-0" NO 0.47 12-0" .44 6" X 8" 28" 3'-0" NO 0.47 12-C 16 -0' 6" X 8" W/2" X 6" 28" 3'-0" NO 0.47 12-0" • 18'-0" 6" X 10" 28" 3'-0" NO_ 0.47 12-0" ' 20',.O" 6" X 12" 28" 3'-0" -- NO 0.47 12-0" 22'-0" 6" X 12" W/2" X 6" 28" 3'-2" NO 0.6 12-0" 24'-0" 6" X 12" 28" 3'-6" NO 0.66 POST/FOOTING SCHEDULE 36' SPANS, 30 & 40 PSF LIVE LOAD POST COLUMN FOOTING KNEE BRACE CONCRETE SPACING "H" W X D "B" DIA. "T' REQUIRED VOLUME, YD3 10'-0" 8'-0" 6" X 6" 28" 3'-0" NO 0.47 10'-0" ---- ----- 10'4" 6" X 6" 28" 3'4" NO 0.47 6" X 6" W/2" X 6" 28" 3'-0" NO 10'-O" 12'-0" 0.47 10'-0" 14'-0" 6" X 6" W/2" X 6" 28" 3'-0" NO 0.47 10'4" 16'-0" 6" X 8" 28" 3'-0" NO 0.47 10'-0" 18'-0" 6" X 8' W/2" X 6" 28" 3'-0" NO 0.47 10'4" 20'-0" 6" X 10" 28" 3'-O" NO 0.47 10'-O" 22'-0" 6" X 10" W/2" X 6" 28" 3'4" NO 0.47 10'-0" 24'-0" 6" X 10" W/7' X 6" 28" 3'-2" YES 0.60 12-0" 8'-0 6" X 6" 32" 3'-0" NO 0.62 124 10 -0 6" X 6 32" 3 -0' NO 0.62 12-0 12 -O 6" X 6" W/2" X 6" 32" 3 -0 NO 0.62 12-0" 14-0 6" • X 8' 32" 3'-O" NO •0.62 12-0" 16 -0 6"X 8"W/2"-X- 6" 32" 3 -0 ' NO 0.62 12-0" 18 -0' 6" X 10" 32" 3'-0' NO_ 0.62 12-0" 20 -0 6" X 10" WIZ' X 6" 32" 3 -0" NO 0.62 2" 1-0 22'-0" 6" X 12" 32" 3'-2" - - NO 0.66 12-0" 24 -0" 6" X 12" W/2" X 6" 32" 3'-3" NO 0.68 POST/FOOTING SCHEDULE 40' SPANS, 30 & 40 PSF LIVE LOAD POST COLUMN FOOTING KNEE BRACE CONCRETE SPACING "H" W X D "B" DIA. "T' REQUIRED VOLUME, YD3 10'-0" 8'-0" 6" X 6" 30" 3'-0" NO 0.66 10'-0' 10'-0" 6" X 6" 30"3'-0" NO 0.66 10'4" 12'-0" 6" X 6" W/2" X 6" 30" 3'-0" -_ NO 0.55 10'-0 14-0' 6"X6 W/2"X6" 30" 3-0' NO 0.66 10'-0 16 -0 6" X 8" 30" 3 -0" YES 0.65 10'-0 16 -0 6" X 8" W/2 X 6" 30" -0 3 ' _ NO 0.55 10'-0" 18'-0" 6" X 8" W/2" X 6" 30" 3'-0" NO 0.66 10'-0" 20'-0" 6" X 10" 30" 3'-0" NO 0.55 10'-0" 22'-0" 6" X 10" W/2" X 6" 30" 3'-0" NO 0.66 10'-0" 24'-0" 6" X 12" 30" 3'-2" YES 0.68 12-0" 8'-0" 6" X 6" 33" 3'-0" NO 0.66 12-0"10 -0 6"X 6"33"-O 3 _ NO 0.66 12-0" 12 -0 6" X 6" W/2 X 6" 33" 3 -0" NO 0.66 12-0" 14'-0" 6" X 8" 33" 3'4" NO • 0.66 12-0" 16'-0" 6" X 8" W/2" X 6" 33" 3'-0" NO 0.66 12-0" 18'-O" 6" X 10" 33" 3'-O" NO 0.66 12.O" 20'-i ' 6 ' X 10 W/2". X 6 ' 33" .i -v' NO 0.66 12-0 __ 22 -0 6" X 12" 33"- 3 2" -N-.O 0.70 12-0" 24'-0" 6" X 12" W/2" X 6" 33" 3'-2" NO. 0.72 POST/FOOTING SCHEDULE 48' TO 52' SPANS, 30 & 40 PSF LIVE LOAD POST COLUMN FOOTING KNEE BRACE CONCRETE SPACING "H" W X D "B" DIA. "T' REQUIRED VOLUME, YD3 10'-0' 8'-0" 6" X 6" 34" 3'-0" NO 0.70 10 -0 10 -0 •-_ NO 0.70 6"X 6"34"3'-•O" 10'-0 12'-O" 6" X 6" W/2" X 6" 34" 3 -0 NO 0.70 10'4" 144' •16 6" X 6" W/2" X 6" 34 3'-0' NO 0.70 10 -0 -0 Si'X 8 34 3'-0' YES 0.70 10'-0 16'-0" 6" X 8" W/2" X 6" 34" 3 -0" NO 0.70 10'-0" 18 0" 6" X 8 W/2' X 6" 34" 3 -0" NO 0.70 104 204' 6'X10 34 3-0' YES 0.70 10'-0 22 -0 6' X 10 W/2 X 6" • 34 3 -0"• NO 0.70 10'-0" 24'-0" 6" X 12" W/7' X 6" 34" 3'-0" YES 0.70 12-0" 8'-0" 6" X 6" • 36" 3 -0" NO 0.79 12-0" 10'-0" 6" X 6" W/2" X 6" 36" 3'-0" NO 0.79 12-0" 12'-0" 6" X 6" W/2" X 6" 36" 3'-0" NO 0.79 12-0" 14'-0" 6" X 8" 36" 3'-0" NO - - 0.79 12-0" 16'-0" 6" X 8" W/2" X 6" 36" 3'-0" NO 0.79 12-0" 18'-0" 6" X 10" 36" 3'-0" YES 0.79 12-0 20 -0' 6" X 10" W/2 X 6" 36" 3'-0" NO 0.79 12-0"22 -0 6"X 12"W/2' X 6"36"3 2 NO 0.83 12-0" 24'-0" 6" X 12" W/2" X 6" 36" 3'-2" NO 0.83 POST/FOOT1 NG SCHEDULE 54' TO 60' SPANS, 30 & 40 PSF LIVE LOAD POST COLUMN FOOTING KNEE BRACE CONCRETE SPACING "H" W X D "B' DIA. "T' REQUIRED VOLUME, YD3 10'-0" 8'-0" 6" X 6" 36" 3'-0" NO 0.79 10'-0 10 -0" 6" X 6" 36" 3'-0" NO 0.79 10'-0 12'-O 6" X 6" W/2" X 6" 36" 3'-0" NO 0.79 10'-O 14 -0 6" X 8" 36" 3'-0" NO 0.79 10'-0" 16'4" 6" X 8" W/2" X 6" 36" 3'-0" NO 0.79 -10'-0" 18'4" 6" X 10" 36" 3'-0" NO_ 0.79 10'-O" 20'-0" 6" X 10" W/2" X6" 3'-0" YES 0.79 10'-0" __ 22'-0" _ 6" X 10" W/2" X 6" _36" 36" 3'-0" NO 0.79 10'-0" 24'4" 6" X 12" 36" 3'-2" YES 0.83 12-0" 8'-0" 6" X 6" 40" 3'-0" NO 0.97 12-0" 10'-0" 6" X 6" W/2" X 6" 40" 3'-0" NO 0.97 12-0" 12'-0" 6" X 8" 40" 3'-0" NO 0.97 12-0" 14'-0" 6" X 8" W/2" X 6" 40" 3'-0" NO 0.97 12-0" 16'-0" 6" X 8" W/2" X 6" 40" 3'-0" NO 0.97 12-0" 18'-0" 6" X 10" 40" 3'-O" YES 0.97 12-0" 20'-0" 6" X 10" W/2" X 6" 40" 3'-0" NO 0.97 -1--0';-22 -0 6 X 12 W/2' X 6" 40 3 -0" NO 0.97 12-0" 24'-0" 6" X 12" W/2" X 6" 40" 3.-2" NO 1.03 :NOTE: 1. THE NEXT LARGER SIZE POST MAY BE SUBSTITUTED FOR POSTS WITH 2" X 6" LAMINATIONS. 2. ENDWALL POSTS SHALL BE 6" X 6" ROUGH CUT HEM -FIR #2 TREATED POSTS UP TO 16'-0" WALL HEIGHT. ABOVE 16' WALL HEIGHT, ENDWALL POSTS SHALL BE 6" X 8" ROUGH CUT -HEM -FIR #2 POSTS. 3. FOOTINGS FOR ENDWALL POSTS SHALL BE A MINIMUM OF 20"0 X 3'-0" DEEP FOR WALL HEIGHTS TO 16'-0". ABOVE 16' WALL HEIGHT, FOOTINGS SHALL BE 24"0 X 3'-4" DEEP: 4. ABOVE ° FOOTING DESIGNS ARE FOR POST FRAME BUILDINGS WITH CONCRETE FLOORS (CONTRAINED POSTS). IF BUILDINGS WILL NOT CONCRETE FLOORS, INCREASE FOOTING DIAMETER X 2" & FOOTING DEPTH X 4". EXPIRES 12 /29/07 e. 7 3177.1Et*_h Da'n!0l EKE ENGINEERING 2913 E. 61st Court arhbeke,`"P. `' E Spokane, WA 99223 Telephone+ 509-443-6186 Fax+ 509-448-6582 e-mail dwanbeke@rnsn.corr LAYOUT, STRUCTURAL DETAILS AND SPECIFICATIONS POST FRAME BUILDINGS 30 & 40 PSF LIVE LOAD, IBC 2003 Z. ; R. ENTERPRISES P. 0. BOX 591 NINE MILE FALLS, WASHINGTON 99026 BY DRAWN WAMBEKE REV BY DATE CHECKED DATE 4-08-06 DRAWING NO.' Z.R..IBC.2003-06 DESCRIPTION OF CHANGE PROJECT NO. 2006 SCALE' N.T.S. SHEET! 1 OF 1 REV. PROVIDE DIAGRAMS AND ENGINEERING LAYOUTS FOR ROOF TRUSSES, BEAMS AND FLOOR SYSTEMS PRIOR TO FRAMING INSPECTIONS CITY. COPY THIS BUILDING SUBJECT TO FIELD INSPECTION CORRECTIONS wtola REVIEWED FOR CODE OMPL . NCE SPOKANE VALLEY BUILD NG DI SION